• Title/Summary/Keyword: cold aging

Search Result 109, Processing Time 0.027 seconds

Effects of Cr content and Thermomechanical Treatment on Tensile Strength and Electrical Conductivity of Cu-Cr Alloys (Cu-Cr 합금의 인장강도와 전기전도도에 미치는 Cr 첨가량 및 가공열처리의 영향)

  • Kim, Ki-Tae;Jung, Woon-Jae;Shin, Han-Chul;Choi, Chong-Sool
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.1
    • /
    • pp.17-21
    • /
    • 2001
  • The effects of Cr content above its solubility limit and thermomechanical treatment on tensile strength and electrical conductivity of Cu-Cr alloys were studied to obtain optimum Cr content exhibiting a high tensile strength without degradation of electrical conductivity. The increase in Cr content above the solubility limit increased tensile strength of Cu-Cr alloys without deterioration of the electrical conductivity. The electrical conductivity was not affected by cold rolling. The electrical conductivity of a Cu-3.5%Cr alloy subjected to cold rolling ${\rightarrow}$ aging treatment ($450^{\circ}C{\times}1hr$) ${\rightarrow}$ cold rolling was equal to that of the alloy subjected to cold rolling ${\rightarrow}$ aging treatment. However, the tensile strength of the alloy subjected to the former thermomechanical treatment was superior to that of the alloy subjected to the latter thermomechanical treatment at all the deformation degrees.

  • PDF

Effect of Cold Stress on Myocardium of Aging Rat (Cold Stress가 노화(老化) 흰쥐 심근(心筋)에 미치는 영향(影響))

  • Kim, Jeong-Ki;Chung, Hyeung-Jae;Lee, Yong-Deok;Park, Won-Hark
    • Applied Microscopy
    • /
    • v.28 no.1
    • /
    • pp.21-38
    • /
    • 1998
  • The present study was performed to determine the effect of cold stress on myocardium of aging rat. Control groups, which aged 6, 12 and 24 months, were compared with age-matched experimental groups that were exposed to moderate cold stress for a hours daily in a week at laboratory cold room $(4{\pm}1^{\circ}C)$. The histological, histochemical and ultrastructural changes of myocardium were observed. The results were summarized as follow: 1. Age-dependent histological change of control groups was observed the formation of contraction band in 24months aged group. The experimental groups submitted to cold stress showed a similar change pattern as seen in control groups. However, the degree of change in the experimental groups was significantly larger than that of control groups. In the 34 months aged group the formation of hypercontraction band was observed. 2. Regarding age-dependent histochemical changes of control groups, we observed the increase activities of PAS and Masson's trichrome. In experimental groups the activities of PAS and Masson's trichrome were also increased with age. Compare with control group, the activities of PAS was increased but the activities of Masson's trichrome was decreased. 3. Age-dependent ultrastructural changes on vacuolization, lysosome were observed. In control groups the structural changes occur at 12 months. The accumulation of lipofuscin, contraction band, hypercontraction band and a component of connective tissue were observed in 24 months. However, the degree of change in the experimental groups was significantly larger than that of control groups. In contract, the myelin body in intercalated discs was observed in 24 months of experimental groups.

  • PDF

The Influence of Dynamic Strain Aging on Tensile and LCF Properties of Prior Cold Worked 316L Stainless Steel (냉간가공된 316L 스테인리스 강의 인장 및 저주기 피로 물성치에 미치는 동적변형시효의 영향)

  • Hong, Seong-Gu;Lee, Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.8
    • /
    • pp.1398-1408
    • /
    • 2003
  • Tensile and LCF(low cycle fatigue) tests were carried out in air at wide temperature range 20$^{\circ}C$-750$^{\circ}C$ and strain rates of 1${\times}$10$\^$-4//s-1${\times}$10$\^$-2/ to ascertain the influence of strain rate on tensile and LCF properties of prior cold worked 316L stainless steel, especially focused on the DSA(dynamic strain aging) regime. Dynamic strain aging induced the change of tensile properties such as strength and ductility in the temperature region 250$^{\circ}C$-600$^{\circ}C$ and this temperature region well coincided with the negative strain rate sensitivity regime. Cyclic stress response at all test conditions was characterized by the initial hardening during a few cycles, followed by gradual softening until final failure. Temperature and strain rate dependence on cyclic softening behavior appears to result from the change of the cyclic plastic deformation mechanism and DSA effect. The DSA regimes between tensile and LCF loading conditions in terms of the negative strain rate sensitivity were well consistent with each other. The drastic reduction in fatigue resistance at elevated temperature was observed, and it was attributed to the effects of oxidation, creep and dynamic strain aging or interactions among them. Especially, in the DSA regime, dynamic strain aging accelerated the reduction of fatigue resistance by enhancing crack initiation and propagation.

Low Temperature δ-Precipitation of Inconel 718 Alloy Wire during Cold Drawing (인코넬 718합금 선재의 냉간 인발시 δ 상 저온 석출 현상 연구)

  • Park, Jae Man;Kim, Yong Hwan;Jang, Heui Un;Chung, Won Sub
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.7
    • /
    • pp.511-516
    • /
    • 2012
  • Low temperature ${\delta}$-precipitation phenomenon below 2-step aging ($718^{\circ}C$, $8hr+621^{\circ}C$, 8 hr) temperature of cold drawn Inconel 718 alloy wire was investigated. The investigation was carried out on wires with a cold drawn ratio of 0, 20, 50 and 70% using OM, SEM, XRD, TEM, and DSC. In microstructures of 50 and 70% drawn wire, many precipitates were found along the grain boundaries and the twin boundaries in deformation band. From the results of the XRD and TEM analysis, the precipitates were identified as plate-like ${\delta}$-phase. From the results of the DSC analysis, it was also found that a temperature of ${\delta}$-precipitation decreases with an increase of the cold drawn ratio. We concluded that cold drawing of inconel 718 wire promotes the ${\delta}$-precipitation, and under the condition of a high drawing ratio, the ${\delta}$-phase could be precipitated at a temperature below the aging temperature ($718^{\circ}C$).

Effect of Exhaust Heat Exchanger on Catalytic Converter Temperature in an SI Engine (가솔린 엔진의 배기 열교환기가 촉매 온도에 미치는 영향에 관한 연구)

  • 이석환;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.9-16
    • /
    • 2004
  • Close-coupled catalyst (CCC) can reduce the engine cold-start emissions by utilizing the energy in the exhaust gas. However, in case the engine is operated at high engine speed and load condition, the catalytic converter may be damaged and eventually deactivated by thermal aging. Excess fuel is sometimes supplied intentionally to lower the exhaust gas temperature avoiding the thermal aging. This sacrifices the fuel economy and exhaust emissions. This paper describes the results of an exhaust heat exchanger to lower the exhaust gas temperature mainly under high load conditions. The heat exchanger was installed between the exhaust manifold and the inlet of close-coupled catalytic converter. The exhaust heat exchanger successfully decreased the exhaust gas temperature, which eliminated the requirement of fuel enrichment under high load conditions. However, the cooling of the exhaust gas through the heat exchanger may cause the deterioration of exhaust emissions at cold start due to the increment of catalyst light-off time.

냉음극 방전관의 기동특성 안정화에 관한 연구 1

  • 지철근
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.18-27
    • /
    • 1965
  • It is well known that the starting characteristics of the cold cathode type discharge tubes are irregular. We have two kinds of stabilization for starting characteristics of discharge tubes. Which are the aging test immediately after producing the tubes and the using characteristics. This paper was devoted primaliry to the empric study of relation between the aging and the manufacturing process. And then to stabilize the starting characteristics of discharge tubes by the irradiations of radio-isotope.

  • PDF

Physico-chemical Properties for Utilization of Aging Index of Cold Storage Beef Tenderloin (냉장우육의 숙성도 지표로 활용하기 위한 물리화학적 특성)

  • 정인철;김미숙;신완철;문윤희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.4
    • /
    • pp.647-653
    • /
    • 1997
  • To establish the index of aging stage for cold storage beef tenderloin, shear force value(SFV), Mg-ATPase activity, myofibrillar fragmentation index(MFI), myofibrillar fragmentation ratio(MFR) and appearance of 30KD(30KD) were measured as the parameters for the indices of aging stage. Aging index of air-packed beef tenderloin stored for 14 days at 3$^{\circ}C$ were useful in the order of SFV(r=-0.893)>MFR (r=0.863) >30KD(r=0.853)>MFI(r=0.814)>Mg-ATPase activity(г=0.804). Vacuum-packed beef tenderloin stored for 28 days at 3$^{\circ}C$ were useful in the order of MFR(r=0.880)>30KD(r=0.836). In case of the correlation between aging indices of air-packed beef tenderloin, MFR had relation with SFV, Mg-ATPase activity, MFI and 30KD. In case of the correlation between aging indices of vacuum-packed beef ten- derloin, MFR had relations with 30KD.

  • PDF

Correlation analysis for 9 respiratory indices and the Cold and Heat score (호흡변이도 및 호흡지표와 한열의 상관관계에 대한 연구)

  • Bas, No-Soo;Oh, Hwan-Sup;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.96-106
    • /
    • 2008
  • Background and purpose : Health is characterized by variability and a loss variability is associated with aging and disease. Normal healthy respiratory patterns are characterized by breath to breath variability. Cold-Heat score are quantified indices in Korean Medicine. The aim of this study is to analyze relations between 9 respiratory indices (including breath to breath variability) and cold-heat score by questionnaire. Method : Respiratory data were measured during 15 minutes and transferred to text file. We calculated 9 respiratory parameters in use of MATLAB7.1. After then we did correlation analysis of 9 respiratory indices and cold-heat score Results and conclusion : EIratio is showed significant correlation with Cold score and weighted Heat score.

  • PDF

An Analysis on the Spatial Spillover Patterns of Aging Population in Rural Areas (공간자기상관을 활용한 농촌지역 인구 고령화의 공간적 확산 분석)

  • Yeo, Chang-Hwan;Seo, Yun-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.3
    • /
    • pp.39-53
    • /
    • 2014
  • The Korean population is aging rapidly and a disproportionate share of older people(aged 65 and older) lives in rural areas. The rural population is aging more rapidly than the population in urban area. However, the majority of studies on aging population focuses on an urban area rather than a rural area. Rural areas have been alienated from the priority of the national policy. For these reasons, this study is to show the level of population aging and to analyze the spatial spillover patterns of aging population in rural areas for the establishment of localized policy on population aging. The main findings of this study can be summarized as follows. First, the level of population aging varies in different localities such as socio-economic and locational characteristics. Secondly, there are distinct differences between hot spot region(clustering of high aging index) and cold spot region(clustering of low aging index) in spatio-temporal spillover patterns. This study intends to suggest an useful information to establish the area-specific policy on aging population through the results of analysis.

Parametric Study of Engine Operating Conditions Affecting on Catalytic Converter Temperature (엔진 문전 조건이 촉매 온도에 미치는 영향)

  • 이석환;배충식;이용표;한태식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.61-69
    • /
    • 2002
  • To meet stringent LEV and ULEV emission standards, a considerable amount of development work was necessary to ensure suitable efficiency and durability of catalyst systems. The main challenge is to cut off the engine cold-start emissions. It is known that up to 80% of the total hydrocarbons(THC) are exhausted within the first five minutes in case of US FTP 75 cycle. Close-Coupled Catalyst(CCC) provides fast light-off temperature by utilizing the energy in the exhaust gas. However, if some malfunction occurred at engine operation and the catalyst temperature exceeds 1050$\^{C}$, the catalytic converter is deactivated and shows the poor conversion efficiency. This paper presents effEcts of engine operating conditions on catalytic converter temperature in a SI engine, which are the indications of catalytic deactivation. Exhaust gas temperature and catalyst temperature were measured as a function of air/fuel ratio, ignition timing and misfire rates. Additionally, light-off time was measured to investigate the effect of operating conditions. It was found that ignition retard and misfire can result in the deactivation of the catalytic converter, which eventually leads the drastic thermal aging of the converter. Significant reduction in light-off time can be achieved with proper control of ignition retard and misfire, which can reduce cold-start HC emissions as well.