• Title/Summary/Keyword: cold Weather

Search Result 521, Processing Time 0.025 seconds

Arduino Sensor based on Traffic Safety System using Intelligence

  • Choi, Myeong-Bok;Hong, You-Sik
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.1
    • /
    • pp.18-23
    • /
    • 2017
  • In 2015, 100-car pileup was happened because the safe distance from the car in front did not be kept due to much fog at YoungJong Bridge in South Korea. This is why the road would be benumbed with cold weather in winter. For this weather condition, if the driver of the car in front changed the lane suddenly or suddenly slammed on the brake in fog or freezing area, the braking distance of the real car has to be 2 or 3 times longer than usual. In this paper, we have simulated the function that warns and notice about the fog area or the freezing one in the road using Arduino sensors and Beacon. Also we propose the intelligent traffic system to protect the accidents in winter.

An Estimation of Cooling Load for Control of Ice Storage System (빙축열 시스템의 제어를 위한 냉방부하 예측)

  • Yoo, Seong-Yeon;Han, Seung-Ho;No, Kwan-Jong;Lee, Je-Myo;Kang, Tae-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.205-210
    • /
    • 2005
  • Ice storage system stores cold energy using ice, which is used for cooling on next day. Ice storage system is the effective cooling system that uses cheep electric energy during a night, and also suppresses the peak load of electricity. In this study, the normalized temperature, relative humidity and specific humidity are analyzed using the weather data for past five years in order to estimate the cooling load for the control of ice storage system. The calculated cooling loads show fairly good agreement with the measured data of model hospital, especially at the outdoor design temperature of $25^{\circ}C$.

  • PDF

A Study on the Small Wastewater Collection System for Rural Area (농촌지역 소규모 오수차집시스템에 관한 연구)

  • Yoon, Chun-Gyeong;Yoo, Chan
    • Journal of Korean Society of Rural Planning
    • /
    • v.4 no.2
    • /
    • pp.20-28
    • /
    • 1998
  • A small wastewater collection system for rural area was reviewed and the small diameter gravity (SDG) was thought to be the most appropriate. The pilot-scale field experiment was performed for 15 months and the result is presented. The wastewater used for experiment was the effluent of septic tank in Kon-Kuk University, and components are similar to normal domestic wastewater. The SDG experimental system included 2" PVC pipe and reverse-sloped lower section is included. No clogging problem by solids was experienced at the points where flow direction changed. The pipe-breaking by freezing was experienced during the cold weather, thus proper protection may be required where severe weather is expected.

  • PDF

Characteristics on Big Data of the Meteorology and Climate Reported in the Media in Korea

  • Choi, Jae-Won;Kim, Hae-Dong
    • Quantitative Bio-Science
    • /
    • v.37 no.2
    • /
    • pp.91-101
    • /
    • 2018
  • This study has analyzed applicable characteristics on big data of the meteorology and climate depending on press releases in the media. As a result, more than half of them were conducted by governmental departments and institutions (26.9%) and meteorological administration (25.0%). Most articles were written by journalists, especially the highest portion stems from straight articles focusing on delivering simple information. For each field, the number of cases had listed in order of rank to be exposed to the media; information service, business management, farming, livestock, and fishing industries, and disaster management, but others did rank far behind; insurance, construction, hydrology and energy. Application of big data about meteorology and climate differed depending on the seasonal change, it was directly related to temperature information during spring, to weather phenomenon such as monsoon and heat wave during summer, to meteorology and climate information during fall, and to weather phenomenon such as cold wave and heavy snow during winter.

Strong wind climatic zones in South Africa

  • Kruger, A.C.;Goliger, A.M.;Retief, J.V.;Sekele, S.
    • Wind and Structures
    • /
    • v.13 no.1
    • /
    • pp.37-55
    • /
    • 2010
  • In this paper South Africa is divided into strong wind climate zones, which indicate the main sources of annual maximum wind gusts. By the analysis of wind gust data of 94 weather stations, which had continuous climate time series of 10 years or longer, six sources, or strong-wind producing mechanisms, could be identified and zoned accordingly. The two primary causes of strong wind gusts are thunderstorm activity and extratropical low pressure systems, which are associated with the passage of cold fronts over the southern African subcontinent. Over the eastern and central interior of South Africa annual maximum wind gusts are usually caused by thunderstorm gust fronts during summer, while in the western and southern interior extratropical cyclones play the most dominant role. Along the coast and adjacent interior annual extreme gusts are usually caused by extratropical cyclones. Four secondary sources of strong winds are the ridging of the quasi-stationary Atlantic and Indian Ocean high pressure systems over the subcontinent, surface troughs to the west in the interior with strong ridging from the east, convergence from the interior towards isolated low pressure systems or deep coastal low pressure systems, and deep surface troughs on the West Coast.

Microclimate and Rice Production (수도작의 미기상과 생산성)

  • Uchijima, Zenbei
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.4
    • /
    • pp.314-339
    • /
    • 1982
  • Fluctuating climate is still most important environmental constrain, although improved modem agricultural technology has succeeded to increase crop production in the world. To stabilize the food production under fluctuating weather conditions, it is very needed to obain the quantitative information of interactions between crops and climate. The main purpose of this paper is three hold. Using the JIBP-data, the dry matter accumulation of rice crops is studied in relation to weather indexes (\SigmaTa and \SigmaSt). Temperature dependence of the yield index of rice is analyzed as to air temperature and water temperature. \SigmaT$_{10}$ -fluctuations are studied using meteorological data at various stations. The possible shift of \SigmaT$_{10}$ -isopleths due to climate fluctuation is evaluated. The second interest is in the plant climate of rice crops. Using results of canopy photosynthesis, it is pointed that the canopy structure has most important implication in plant climate. Leaf-air, stomatal, and mesophyll resistances of rice crops are described in relation to weather conditions. The change in light condition and aerodynamical property of rice crops with the growth is illustrated. The energy partition is also studied at different growing stages. Third point is to show in more detail effective countermeasures against cold irrigation water and cool summer. Heat balance of warming pond and polyethylene tube as a heat exchanger is studied to make nomo-grams for evaluating the necessary area and necessary length. Effects of windbreak net on rice crops are illustrated by using experimental and simulation results.lts.

  • PDF

The Characteristics of Air Temperature according to the Location of Automatic Weather System (AWS 설치장소에 따른 기온 특성)

  • Joo, Hyong-Don;Lee, Mi-Ja;Ham, In-Wha
    • Atmosphere
    • /
    • v.15 no.3
    • /
    • pp.179-186
    • /
    • 2005
  • Due to several difficulties, a number of Automatic Weather Systems (AWS) operated by Korea Meteorological Administration (KMA) are located on the rooftop so that the forming of standard observation environment to obtain the accuracy is needed. Therefore, the air temperature of AWSs on the synthetic lawn and the concrete of the rooftop is compared with the standard observation temperature. The hourly mean temperature is obtained by monthly and hourly mean value and the difference of temperature is calculated according to the location, the weather phenomenon, and cloud amount. The maximum and the minimum temperatures are compared by the conditions, such as cloud amount, the existence of precipitation or not. Consequently, the temperature on the synthetic lawn is higher than it on the concrete so that it is difficult to obtain same effect from ASOS, on the contrary the installation of AWS on the synthetic lawn seem to be inadequate due to heat or cold source of the building.

Effects of Network Density on Gridded Horizontal Distribution of Meteorological Variables in the Seoul Metropolitan Area (관측망 밀도가 기상 자료의 격자형 수평 분포에 미치는 영향)

  • Kang, Minsoo;Park, Moon-Soo;Chae, Jung-Hoon;Min, Jae-Sik;Chung, Boo Yeon;Han, Seong Eui
    • Atmosphere
    • /
    • v.29 no.2
    • /
    • pp.183-196
    • /
    • 2019
  • High-quality and high-resolution meteorological information is essential to reduce damages due to disastrous weather phenomena such as flash flood, strong wind, and heat/cold waves. There are many meteorological observation stations operated by Korea Meteorological Administration (KMA) in Seoul Metropolitan Area (SMA). Nonetheless, they are still not enough to represent small-scale weather phenomena like convective storm cells due to its poor resolution, especially over urban areas with high-rise buildings and complex land use. In this study, feasibilities to use additional pre-existing networks (e.g., operated by local government and private company) are tested by investigating the effects of network density on the gridded horizontal distribution of two meteorological variables (temperature and precipitation). Two heat wave event days and two precipitation events are chosen, respectively. And the automatic weather station (AWS) networks operated by KMA, local-government, and SKTechX in Incheon area are used. It is found that as network density increases, correlation coefficients between the interpolated values with a horizontal resolution of 350 m and observed data also become large. The range of correlation coefficients with respect to the network density shows large in nighttime rather than in daytime for temperature. While, the range does not depend on the time of day, but on the precipitation type and horizontal distribution of convection cells. This study suggests that temperature and precipitation sensors should be added at points with large horizontal inhomogeneity of land use or topography to represent the horizontal features with a resolution higher than 350 m.

A Case Study of Snowfall Event over Yeongdong Region on March 1-2, 2021 (2021년 3월 1-2일 영동지역 강설 사례 연구)

  • Bo-Yeong Ahn;Byunghwan Lim
    • Journal of the Korean earth science society
    • /
    • v.44 no.2
    • /
    • pp.119-134
    • /
    • 2023
  • The synoptic, thermodynamic, and dynamic characteristics of a snowfall event that occurred in the Yeongdong region on March 1-2, 2021, were investigated. Surface weather charts, ERA5 reanalysis data, rawinsonde data, GK-2A satellite data, and WISSDOM data were used for analysis. The snow depth, exceeding 10 cm, was observed at four weather stations during the analysis period. The maximum snow depth (37.4 cm) occurred at Bukgangneung. According to the analysis of the weather charts, old and dry air was trapped within relatively warm, humid air in the upper atmosphere over the East Sea and adjacent Yeongdong region. This caused unstable atmospheric conditions that led to developing convective clouds and snowfall over Bukgangneung. In particular, based on the thermodynamic and kinematic vertical analysis, we suggest that strong winds attributable to the vertical gradient of potential temperature in the low layer and the development of convective instability due to cold advection played a significant role in the occurrence of snowfall in the Yeongdong region. These results were confirmed from the vertical analysis of the rawinsonde data.

Effect of Sea Surface Temperature Gradient Induced by the Previous Typhoon's Cold Wake on the Track of the Following Typhoon: Bolaven (1215) and Tembin (1214) (선행 태풍의 해수 냉각에 의한 해수면 온도 경도가 후행 태풍의 진로에 미치는 영향: 볼라벤(1215)과 덴빈(1214))

  • Moon, Mincheol;Choi, Yumi;Ha, Kyung-Ja
    • Atmosphere
    • /
    • v.26 no.4
    • /
    • pp.635-647
    • /
    • 2016
  • The effects of sea surface temperature (SST) gradient induced by the previous typhoon on the following typhoon motion over East Asia have been investigated using Weather Research and Forecasting (WRF) model for the previous Typhoon Bolaven (1215) and following Typhoon Tembin (1214). It was observed that Typhoon Bolaven remarkably reduced SST by about $7^{\circ}C$ at Yellow Sea buoy (YSbuoy). Using the WRF experiments for the imposed cold wake over West of Tembin (WT) and over East of Tembin (ET), this study demonstrates that the effects of eastward SST gradient including cold wake over WT is much significant rather than that over ET in relation to unexpected Tembin's eastward deflection. This difference between two experiments is attributed to the fact that cold wake over WT increases the magnitude of SST gradient under the eastward SST gradient around East Asia and the resultant asymmetric flow deflects Typhoon Tembin eastward, which is mainly due to the different atmospheric response to the SST forcing between ET and WT. Therefore, it implies that the enhanced eastward SST gradient over East Asia results in larger typhoon deflection toward the region of warmer SST according to the location of the cold wake effect. This result can contribute to the improvement of track prediction for typhoons influencing the Korean Peninsula