• Title/Summary/Keyword: coefficient result

Search Result 4,876, Processing Time 0.037 seconds

Evaluation of Lead levels in Airborne by a portable X-Ray Fluorescence Instrument (휴대용 X-Ray 형광기기(XRF)를 이용한 공기중 납농도 평가)

  • Ahn, Kyu Dong;Lee, Jong Chun;Cho, Kwang Sung;Kim, Nam Su;Kim, Jin Ho;Lee, Sung Soo;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.235-240
    • /
    • 2001
  • This study was performed to compare the lead levels of 20 quality control standard samples(KOSHA:18-2000) and 72 field samples in lead-acid battery manufacturing plant between ICP and portable-XRF methods. 1. While the proficiencies of 20 quality control standard samples by ICP were 100%, those of analytic result values by XRF were 75%. 2. The correlation coefficient(r) between the reference values for quality control (REF) and the analytic result values by ICP (ICP) was 1.0(p<0.05), and simple linear regression equation and the coefficient(R2) were REF = -0.0009 + 1.016 ICP and 0.9997, respectively. 3. The correlation coefficient(r) between the analytic result values of quality control standard samples by ICP (ICP) and by XRF (XRF) was 0.975(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -0.0003 + 1.002 XRF and 0.950, respectively. 4. The correlation coefficient(r) between the analytic result values for lead samples of a lead-acid battery manufacturing plant by ICP (ICP) and by XRF (XRF) was 0.993(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -2.058 + 0.996 XRF and 0.987, respectively. 5. While the frequency distributions of XRF /ICP(Ratio) for each ICP concentration levels in a lead-acid battery manufacturing plant revealed high proportion in ratio range of 0.876-1.125 than in ration range of 1.126-1.375. Also, ICP concentration level in ration range of 0.786-1.125 was increased with increase of frequency distribution of XRF/ICP. 6. The limit of detection of XRF on lead was determined to be $6.11{\mu}g$/filter The data presented in this study indicated that relationship for lead level of quality control samples and field samples in a lead -acid battery manufacturing plant by ICP and portable-XRF methods was proved. The practicing industrial hygienist can use portable-XRF to produce a rapid on-site determination of lead exposure that can immediately becommunicated to workers and help identify appropriate levels of personal protection.

  • PDF

Study of Sasang Constitution Classification Method Based on Elasticity Coefficient of Hand Doral Skin of Elderly People (고령자의 손등피부 탄성 특성을 활용한 체질분류 방법 연구)

  • Kang, Nam-Sik;Lee, Jae-Chul;Ku, Bon-Cho;Kim, Jong-Yeol;Kim, Young-Min
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.6
    • /
    • pp.1050-1055
    • /
    • 2011
  • This paper presents a novel diagnostic method to determine Sasang Consitution (SC) by elasticity coefficient of hand dorsal skin of elderly people. For this purpose, we carried out a clinical test, in which Our SC diagnostic tool and one Oriental medical doctor with SC medicine expertise participated to categorize 458 healthy subjects into four constitutions. After excluding heavy-noise, we extracted 295 subjects' elasticity coefficient feature data and statistically analyzed their SC relevance with ANOVA test. It resulted in that, Taeum-in has high elasticity coefficient compared to Soeum-in in a significance level of 0.05. There are no differences of elasticity coefficient in genders. This result is supported by the theory of Longevity and Life Preservation in Eastern Medicine(Donguisusebowon, 동의수세보원) which suggested that Taeum-in's flesh is solid and Soeum-in's one is tender. This is the first work which reports the relatedness of skin elasticity coefficient and SC by an objective clinical test.

A Study on the Shock Absorption Performance of the Safety Helmet using Coefficient of Restitution (반발계수를 이용한 안전모의 충격 흡수 성능에 관한 연구)

  • Shin, Woon-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.30-34
    • /
    • 2012
  • A safety helmet is a personal protective equipment to protect the head from falling and flying objects. A safety helmet has the maximum delivered impact force as shock absorption performance, the lower delivered impact force the better performance, which was not a controlled variety during manufacturing safety helmet. Accordingly there were some difficulties in establishing the standard for improved performance as there was not a clear controllable impact force for improved performance. In this study the shock absorption performance was intended to be found as coefficient of restitution related to impulse. As a research method, a coefficient of restitution during the absorption of shock was calculated using the impulse transferred to pharynx utilizing the safety helmet shock absorption performance testing device based on the theory of momentum and impulse. The estimated impulsive force curve was derived assuming that shock was not absorbed using the measured data. The sample was selected as tested goods of ABS material for safety certification available mainly in the market. As a result of study, the maximum delivered impact force of safety helmet made by a domestic safety certified a company was 735 N, and its coefficient of restitution proved to be 0.64. The smaller coefficient of restitution is, the lower maximum delivered impact force and the higher shock absorption performance. The coefficient of restitution can be used as a performance index of safety helmet.

A prediction of indoor pollutant concentration using method mass transfer coefficient in multi-layered building materials (복합 건축자재의 물질전달계수를 이용한 실내 오염물질 농도 예측방법)

  • Kim, Chang Nam;Lee, Yun Gyu;Leigh, Seung Bok;Kim, Tae Yeon
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.53-58
    • /
    • 2007
  • In order to predict the indoor air pollutant, the VOCs emission rate is used through small chamber in the design process. However, the small chamber method has limitations as the convective mass transfer coefficient, the most important factor when predicting VOCs contamination of indoor air, is different between the small chamber result and the measured data in the actual building. Furthermore, the existing studies which analyzed mass transfer coefficient in the small chamber were directed on the small chambers developed at the time and FLEC(Field and Laboratory Emission Cell), thus, are different from the current small chamber which has been changed with improvements. The purpose of this study is to determine the emission rate of pollutant in multi-layered building materials, and predict the indoor pollutant concentration through the CFD(Computational of Fluid Dynamics) and CRIAQ2 based on the mass transfer coefficient on singled-layered building material by using the current small chamber widely used in Korea. Futhermore, this study used the new convective mass transfer coefficient(hm') which indicates the existing convective mass transfer coefficient(hm) including VOC partition coefficient(k). Also, formaldehyde was selected as target pollutant.

ASSESSMENT OF THE TiO2/WATER NANOFLUID EFFECTS ON HEAT TRANSFER CHARACTERISTICS IN VVER-1000 NUCLEAR REACTOR USING CFD MODELING

  • MOUSAVIZADEH, SEYED MOHAMMAD;ANSARIFAR, GHOLAM REZA;TALEBI, MANSOUR
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.814-826
    • /
    • 2015
  • The most important advantage of nanoparticles is the increased thermal conductivity coefficient and convection heat transfer coefficient so that, as a result of using a 1.5% volume concentration of nanoparticles, the thermal conductivity coefficient would increase by about twice. In this paper, the effects of a nanofluid ($TiO_2$/water) on heat transfer characteristics such as the thermal conductivity coefficient, heat transfer coefficient, fuel clad, and fuel center temperatures in a VVER-1000 nuclear reactor are investigated. To this end, the cell equivalent of a fuel rod and its surrounding coolant fluid were obtained in the hexagonal fuel assembly of a VVER-1000 reactor. Then, a fuel rod was simulated in the hot channel using Computational Fluid Dynamics (CFD) simulation codes and thermohydraulic calculations (maximum fuel temperature, fluid outlet, Minimum Departure from Nucleate Boiling Ratio (MDNBR), etc.) were performed and compared with a VVER-1000 reactor without nanoparticles. One of the most important results of the analysis was that heat transfer and the thermal conductivity coefficient increased, and usage of the nanofluid reduced MDNBR.

Development of Longitudinal Dispersion Coefficient Based on Theoretical Equation for Transverse Distribution of Stream-Wise Velocity in Open Channel : Part II. Longitudinal Dispersion Coefficient (개수로에서 흐름방향 유속의 횡분포 이론식에 기반한 종분산계수 개발 : II. 종분산계수)

  • Baek, Kyong Oh
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.4
    • /
    • pp.299-308
    • /
    • 2015
  • The aim of this study is that a theoretical formula for estimating the one-dimensional longitudinal dispersion coefficient is derived based on a transverse distribution equation for the depth averaged stream-wise velocity in open channel. In "Part I. Theoretical equation for stream-wise velocity" which is the former volume of this article, the velocity distribution equation is derived analytically based on the Shiono-Knight Method (SKM). And then incorporating the velocity distribution equation into a triple integral formula which was proposed by Fischer (1968), the one-dimensional longitudinal dispersion coefficient can be derived theoretically in "Part II. Longitudinal dispersion coefficient" which is the latter volume of this article. The proposed equations for the velocity distribution and the longitudinal dispersion coefficient are verified by using observed data set. As a result, the non-dimensional longitudinal dispersion coefficient is inversely proportional to square of the Manning's roughness coefficient and the non-dimensional transverse dispersion coefficient, and is directly proportional to square of the aspect ratio (channel width to depth).

The Practical Method and Experimental Verification of Temperature Estimation in the Permanent Magnet of Electric Machine

  • Kang, Kyongho;Yu, Sukjin;Lee, Geunho;Lee, Byeong-Hwa
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.421-426
    • /
    • 2015
  • This paper presents a practical method for estimation of average temperature in the permanent magnet (PM) of electric machine by using finite element analysis (FEA) and dynamo load experiment. First of all, the temperature effect of PM to the torque has been employed by FEA in order to evaluate the Temperature-Torque characteristic curve. The 1st order polynomial equation which is torque attenuation coefficient is derived by the FEA result of the Temperature-Torque curve. Next, torque saturation test with constant current condition is performed by dynamo load experiment. Then, the temperature trend can be estimated by adding the initial starting temperature using the torque attenuation coefficient and torque saturation curve. Lastly, estimated temperature is validated by infrared thermometer which measures temperature of PM surface. The comparison between the estimated result and experimental result gives a good agreement within a deviation of maximum $8^{\circ}C$.

A Design of K-Band Low Phase noise Oscillator by Direct Coupling of K-band Dielectric Resonator (유전체 공진기의 직접결합에 의한 K-Band 저위상잡음 발진기 설계)

  • Lim, Eun-Jae;Han, Geon-Hee;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • In this paper, we analysed coupling coefficient between dielectric resonator of high dielectric constant and microstrip line to design for low phase noise dielectric resonator by direct coupling. Also we analysed phase noise of dielectric resonance oscillator with parallel feedback circuit to complement Q by high dielectric constant. We obtained a result from high-stability dielectric oscillator which is optimum designed through analysis of dielectric resonance oscillator phase noise and coupling coefficient. The result is that the phase noise was -83.3dBc/Hz@1KHz at 20.25GHz when we used about 3.6 coupling coefficient and ${\epsilon}_r$=30 dielectric resonator of 20.25GHz dielectric resonance oscillator. As a result, we suggested the direct-connect design method by frequency multiplication mode to prevent phase noise loss at K-Band.

Wave Field Analysis around Permeable Rubble-Mound Breakwaters (투과 사석방파제 주변의 파랑장 해석)

  • 곽문수;이기상;편종근
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.2
    • /
    • pp.116-126
    • /
    • 2003
  • In this study, a method that leads to make a simple decision on important parameters in analysis of wave field in permeable rubble-mound, block-mound breakwater, such as penetration velocity of incident waves and resistance coefficient, is introduced. A model that could analyze wave field of permeable breakwater in harbor, by applying these methods and arbitrary transmission coefficient boundary condition to a time-dependent mild-slope equation, was introduced. The verification of the model was done by carrying out 2-D physical model test on permeable breakwater, measuring the change in water surface elevation, comparing the computation result with time series, and comparing the result gained from the 3-D physical model test on permeable block-mound breakwater in an field harbor with the computation result in terms of regional wave height ratio in a harbor.

The Evaluation of Seismic Performance on the Concrete Dam of Analysis Method (해석방법에 따른 콘크리트댐의 내진성능평가)

  • 임정열;이종욱;오병현
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.1-9
    • /
    • 2003
  • The seismic design of the domestic concrete dams has done by seismic coefficient method considering inertia force, but this method has defect not reflect dynamic properties, as a conservative design method. Therefore, it is necessary for seismic design of dam to consider dynamic properties. Also, concrete dam evaluation of seismic performance has done by seismic coefficient method - in fact, it may done by dynamic analysis - that has many problems when applied to the domestic criteria. This study make a comparative analysis for result from seismic design and evaluation of seismic performance by seismic coefficient method, modified seismic coefficient method, and dynamic analysis method.