• Title/Summary/Keyword: coefficient of $CO_2$

Search Result 1,218, Processing Time 0.034 seconds

Field Appliciability Evaluation of Eco-friendly Mixed Soil (친환경 혼합토의 현장적용성 평가)

  • Park, Kyungsik;Oh, Sewook;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.17-25
    • /
    • 2014
  • In the present study, it were performed an unconfined compression test and a field applicability test according to a mixed ratio of SS, soil type and curing period to analyze strength and deformation characteristic in order to evaluate engineering characteristics of soil mixed pavements using the eco-friendly soil stabilizer (SS). The test results revealed that SS mixed soil shows fast strength development at the initial curing time while 28-day strength amounted for 97% of the final strength. Furthermore, coarse-grained dredged sand (DS) and weathered granitic soil (WGS) have a larger ratio of deformation coefficient with respect to unconfined compressive strength than fine-grained dredged clay (DC) and organic soil (OS). Moreover, a comparison test between natural and forced drying conditions was conducted and test result showed 54% to 67% of strength degradation while having 55% to 63% of strength degradation in the freezing and thawing test result. Finally, a repeated loading test result showed that DS experiences up to 35% of strength reduction compared to initial strength under 10,000 times loading in maximum. Thus, it was validated that an appropriate amount of fine-grained sand is necessary to secure resistance capability to repeated loading.

Experimental Study on Fretting Wear of Inconel 690 Under High Temperatures and Pressures (고온 고압 환경에서 인코넬 690 재료의 프레팅 마모 특성에 관한 실험적 연구)

  • Lee, Coon-Yeol;Lee, Ju-Suck;Bae, Joon-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.6
    • /
    • pp.637-644
    • /
    • 2012
  • In a nuclear power plant, fretting wear due to impact motion between U-tubes and support structures located in steam generators can cause serious problems. In order to guarantee the reliability of the steam generator, the damage due to fretting wear should be thoroughly investigated. The purpose of this study is to elucidate the fretting wear mechanism qualitatively and quantitatively. Hence, fretting wear simulation is performed for the environments to which the actual steam generators in nuclear power plants are exposed. Initial experimental results are obtained for various experimental parameters, and the effect of the work rate and temperature on fretting wear is evaluated. In water, the wear coefficients for $90^{\circ}C$, $200^{\circ}C$, and $340^{\circ}C$ are found to be $9.051{\times}10^{-16}\;Pa^{-1}$, $3.009{\times}10^{-15}\;Pa^{-1}$, and $2.235{\times}10^{-15}\;Pa^{-1}$, respectively. It is also found that the wear coefficient at room temperature is larger than that at low temperature in water because of the dynamic viscosity of water.

A Study on the Manoeuvrability as Function of Stern Hull Form in Shallow Water (선미형상을 고려한 천수역에서의 조종성능에 관한 연구)

  • Lee, Sungwook
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.5
    • /
    • pp.552-557
    • /
    • 2015
  • A numerical simulation studies were performed to investigate a manoeuvring characteristics as function of stern hull form with the mathematical model. In order to consider the effect of the stern hull form and obtain the manoeuvring characteristics, a parameter($C_{wa}$) which is aft. water plane area coefficient is modified. Because modifying $C_{wa}$(${\pm}2%$) means that the stern hull form is modified to V-type or U-type, the numerical simulation was performed with this modified $C_{wa}$. A changing trend for the manoeuvring characteristics not only in deep water but also in shallow water such as directional stability, turning and zig-zag was investigated and presented as the results. Present study showed that the manoeuvrability in shallow water largely changed when the draught and water depth ratio(=d/H) become 0.5, and the stern hull form can affect to the manoeuvrability of a vessel navigating in restricted water depth. In addition, it showed that approaching the stern hull to U-type makes the advance and tactical diameter of turning motion large and the overshoot angle of zig-zag motions small. Otherwise, it showed approaching the stern hull form to V-type makes the advance and tactical diameter of turning motion small and the overshoot angle of zig-zag motions large in the present study.

The Heat Pump Application to the Food Concentration (열 펌프의 식품 농축에의 이용 연구)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Kang, Tong-Sam;Shin, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.486-491
    • /
    • 1987
  • The performance and applicability to food concentration of heat pump were investigated. During heating the water of spa from $43^{\circ}C$ to $51^{\circ}C$, COP's of heat pump (R-12, 150 HP) were 4.03 at heating part and 3.5 at cooling part. And, the efficiency of compressor (${\alpha}$) was 0.477 While the city water was heated to $39^{\circ}C$ by heat pump (R-22, 10 HP), its COP's were 3.0 at heating part and 1.87 at cooling part. During concentrations sucrose solution by centrifugal evaporator (ALFA-LAVAL CO, CTIB) with heat pump, heat capacity for condensating water vapor was required greater 15% than the latent heat for concentrating and then the overall heat transfer coefficient was $1196\;Kcal/m^{2}.\;h.\;^{\circ}C$. When low temperature concentration ($30-35^{\circ}C$, 28-40 Torr) of garlic extract was carried out by the water of $60^{\circ}C$ and $15^{\circ}C$ adjusted by heat pump, the ratio of heat capacity for concentrating vs. that for condensating of water vapor was 0.961.

  • PDF

An Analysis of Nursing Behavior and Unit of Treatment Cost of Non- Insurance Patients (종합병원의 비보험환자 처치행위 양상과 수가분석에 관한 연구)

  • 오세영
    • Journal of Korean Academy of Nursing
    • /
    • v.10 no.1
    • /
    • pp.41-55
    • /
    • 1980
  • The medical care insurance system, being put into practice nearly for three years, seem to have brought about some considerable problems as serious for the government as to consider a revision of that system. As one of the most serious problems of present system, the treatment cost of insurance patients is so remarkably low in comparison with than of non-insurance cases that normal operation of hospitals is threatened and care services of low quality are induced. The researcher carried out this survey to analyze and bring to light several aspects of treatment cost of non-insurance patients as a material for a re-assessment of the cost of insurance cases which shows a a considerable difference in amount at the standpoint of hospitals with than of non-insurance cases and further, hoping the significant blind spot of present insurance system(that is, the absence of regulations' for cost assessment by patterns or types of health care treatment) will be mended in near future. The survey was carried out with the treatment invoice sheets of total 902 in-hospital Patients of a general hospital in Seoul during the period of the 2 nd quarter of the year(1979). Among total 902 patients, 694 cases were used for analysis, because those disease or syndromes shared by less than 10% of the patients were put aside before procession. The data were analyzed by kinds or types of diseases, demographic characteristics of patients, hospitalization patterns, types of nursing treatment, etc. The result of analysis was as follows 1. Among all the non-insurance cases, those who received one or more kinds of nursing treatment mounted up to 96. 7 %. The invoice issue frequency per person was 7.2 times, while that frequency per day for a person was 0.8, : the treatment cosr per person was ₩22,650 while its daily average was ₩2,430, due to the average 9.3 in-hospital days per person. 2. As to the nursing treatment types by the demographic characteristics of patients and hospitalization patterns. a. The unit cost female patients was generally more expensive them that of males, and independent nursing service was more given than other types of treatment. As to age, higher age groups received independent nursing service most, while the youngest group received instrumental and integrated nursing services. b. As to room grade, the unit cost of I.C.U. cases was the highest : and the cast of private room patients was higher than that of public room patients. By in-hospital days, the curve of function showed L. type : that is, the longer stay, the lower function. 3. State of treatment types by kinds of disease were ; a. Dependent nursing service showed comparatively high availability in surgical and neurologic disease and independent nursing service was most received by medical, obstetrical and urological patients, while instrumental and integrated services were most available for respiratory disease and obstetrical and neurologic diseases next. b. The invoice issue frequency per day for a patient was highest in obstetrical disease 3.8 times, and the unit cost(per one invoice sheet) was also highest in obstertrical disease(₩10,880) and next in neurologic cases(₩ 4,690 ). 4. As to the pertained departments. a. Cost amount per person was highest in department of Psychiatries daily cost was highest in obstetrical cases : while the invoice issue frequency was highest in obstetrics and next in pediatrics. b. In departments in need of surgical operation, dependent nursing care was highly availabl : while in internal medicine and obstetrics, independent service was higher. Psychiatrics showed the highest the of integrate nursing while pediatrics and obstetrics higher of instrumental services. The variation co-efficien of treatment cost came out to be relatively in high in special surgery, opthalmology and internal medicine. 5. State of treatment cost by types of nursing behavior was. a. The average frequency of invoice issue was 3.5 (times). Among the type four types of treatment, instrumetal service (4.3) and independent nursing behavior(3.9) showed higher frequency than average respectively. But as to unit cost (per invoice). dependent (₩5,200) and integrated (₩5,340) nursing care services were higher than average and considerably higher than the other two types. b. In repect patient distribution. independent nursing behavior(80.3% ) was the highest and depend ent nursing (31.7% ) the lowest. The variation co-efficient of treatment cost appeared highest in dependent nursing be havior as a whole, and among that, doctor's diagnosis showed the highest coefficient value (100.7). In conclusion, the variaty of treatment cost(treatment itself ) by various characteristics and treatment types pro- that treatment various sort of patients and treatment cost of various types of nursing behavior cannot be uniform. Therefore, to attain the equalization of health care service and its cost both for insurant and non-insurant patients, a more specific provision for assessment of cost should be added to the present medical care insurance system and, in addition, the cost of nursing treatment is desired to be inserted into the treatment invoice.

  • PDF

Feasibility Study of the Radiophotoluminescent Glass Dosimeter for High-energy Electron Beams (유리선량계를 이용한 고에너지 전자선 측정 이용 가능성에 관한 연구)

  • Son, Ki-Hong;Jung, Hai-Jo;Shin, Sang-Hun;Lee, Hyun-Ho;Lee, Sung-Hyun;Kim, Mi-Sook;Ji, Young-Hoon;Kim, Kum-Bae
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.52-58
    • /
    • 2011
  • Our goal is to assess the suitability of a glass dosimeter on detection of high-energy electron beams for clinical use, especially for radiation therapy. We examined the dosimetric characteristics of glass dosimeters including dose linearity, reproducibility, angular dependence, dose rate dependence, and energy dependence of 5 different electron energy qualities. The GD was irradiated with high-energy electron beams from the medical linear accelerator andgamma rays from a cobalt-60 teletherapy unit. All irradiations were performed in a water phantom. The result of the dose linearity for high-energy electron beams showed well fitted regression line with the coefficient of determination; $R^2$ of 0.999 between 6 and 20 MeV. The reproducibility of GDs exposed to the nominal electron energies 6, 9, 12, 16, and 20 MeV was ${\pm}1.2%$. In terms of the angular dependence to electron beams,GD response differences to the electron beam were within 1.5% for angles ranging from $0^{\circ}$ to $90^{\circ}$ and GD's maximum response differencewas 14% lower at 180o. In the dose rate dependence, measured dose values were normalized to the value obtained from 500 MU/min. The uncertainties of dose rate were measured within ${\pm}1.5%$ except for the value from 100 MU/min. In the evaluation of the energy dependence of the GD at nominal electron energies between 6 and 20 MeV, we obtained lower responses between 1.1% and 4.5% based on cobalt-60 beam. Our results show that GDs have a considerable potentiality for measuring doses delivered by high-energy electron beams.

Changes in Quality of Lettuce During Storage by Immersion-Type Hydrocooling (침지식 냉수냉각에 의한 상치의 저장중 품질변화)

  • Jeong, Jin-Woong;Kim, Byeong-Sam;Kim, Oni-Woung;Nahmgung, Bae;Park, Kee-Jai
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.537-545
    • /
    • 1995
  • Quality changes of lettuce were studied during storage to investigate the efficiency, cooling properties and the washing and storage effects of immersion-type hydrocooling. As a result of plotting the nondimensionalized lettuce temperature versus cooling time, its cooling rate coefficient was shown to be $-0.365\;min^{-1}{\sim}-0.255\;min^{-1}\;(R^2=0.99{\sim}0.88)$. Rate of weight loss was not significantly (p>0.05) different between lettuces with various treatment conditions during storage at $5^{\circ}C$. However, during storage at $15^{\circ}C$, weight loss of hydrocooled lettuce was lower than that of non-treated lettuce after from 10 to 15 days. Especially, The lettuce packed with PE was more effective than that packed with try in terms of packing condition after hydrocooling. Lettuce pretreated with sterilizing agent, packed with PE vinyl film, removed residual water after hydrocooling had lower decaying rate than any other lettuces. Changes of L and b values in hydrocooled lettuce were slower than those of non-treated one. During changes of chlorophyll content, the initial value, $115.7{\sim}147.3\;mg%$ was decreased to $50{\sim}60%$ after 25 days of storage at $5^{\circ}C$ and within 15 days of storage at $15^{\circ}C$. It could be presumed that the addition of sterilizing agent reduced the initial level of overall total and coliform count and its growth rate during storage. The respiration rate of hydrocooled lettuce at $5^{\circ}C$ was $23.95\;mg{\cdot}CO_2/kg\;hr$, which is 10% of those of non-treated lettuce.

  • PDF

Prediction Model of Weed Population in Paddy Fields - I. Practical Approach to Development of Prediction Model (논 잡초발생(雜草發生) 예측(豫測)모델 개발(開發) 연구(硏究) - I. 예측(豫測)모델 개발(開發) 접근방법(接近方法))

  • Lee, H.K.;Lee, I.Y.;Ryu, G.H.;Lee, J.O.;Park, Y.S.
    • Korean Journal of Weed Science
    • /
    • v.13 no.2
    • /
    • pp.104-113
    • /
    • 1993
  • The experiment was conducted in 1992 to find out the approach to the development of prediction model of weed population in paddy fields. The weed seeds of 88% over were separated from the soil by using $K_2CO_3$ 50% solution with specific gravity 1.34. The weed seeds which were floated on the solution due to the difference of specific gravity between soil particles and the seeds were effectively withdrawn by using a vaccum pump attached with an aspirator. The seeds withdrawn together with solution were taken by filtering with a nylon net of $0.31{\times}0.16mm$ mesh. The pressing method was more efficient and practical for the viability test of weed seeds separated from the soil compared with the germination test and the TTC test. For the prediction of weed population by the number of weed seedlings emerged at the sampled soil, the sampling method of 0-10cm deep at 5-6 sites per field was applicable. At the prediction method by the number of seedlings emerged, the smaller the seed sizes, the lower the prediction coefficients of weed species. It was considered that the prediction method by the number of seedlings emerged was more practical than the prediction method by the number of seeds separated from sampled soil, in relation to similarities to weed population, time and expenses required for examining, technical difficulties and applicability of weed species.

  • PDF

Optimization of a Medium for the Production of Cellulase by Bacillus subtilis NC1 Using Response Surface Methodology (반응 표면 분석법을 사용한 Bacillus subtilis NC1 유래 cellulase 생산 배지 최적화)

  • Yang, Hee-Jong;Park, Chang-Su;Yang, Ho-Yeon;Jeong, Su-Ji;Jeong, Seong-Yeop;Jeong, Do-Youn;Kang, Dae-Ook;Moon, Ja-Young;Choi, Nack-Shick
    • Journal of Life Science
    • /
    • v.25 no.6
    • /
    • pp.680-685
    • /
    • 2015
  • Previously, cellulase and xylanase producing microorganism, Bacillus subtilis NC1, was isolated from soil. Based on the 16S rRNA gene sequence and API 50 CHL test the strain was identified as Bacillus subtilis, and named as B. subtilis NC1. We cloned and sequenced the genes for cellulase and xylanase. Plus, the deduced amino acid sequences from the genes of cellulase and xylanase were determined and were also identified as glycosyl hydrolases family (GH) 5 and 30, respectively. In this study to optimize the medium parameters for cellulase production by B. subtilis NC1 the RSM (response surface methodology) based on CCD (central composite design) model was performed. Three factors, tryptone, yeast extract, and NaCl, for N or C source were investigated. The cellulase activity was measured with a carboxylmethyl cellulose (CMC) plate and the 3,5-dinitrosalicylic acid (DNS) methods. The coefficient of determination (R2) for the model was 0.960, and the probability value (p=0.0001) of the regression model was highly significant. Based on the RSM, the optimum conditions for cellulase production by B. subtilis NC1 were predicted to be tryptone of 2.5%, yeast extract of 0.5%, and NaCl of 1.0%. Through the model verification, cellulase activity of Bacillus subtilis NC1 increased from 0.5 to 0.62 U/ml (24%) compared to the original medium.

Effects of Soil Organic Matter Contents, Paddy Types and Agricultural Climatic Zone on CH4 Emissions from Rice Paddy Field (벼 논에서 토양 유기물 함량, 논 유형 및 농업기후대가 CH4 배출에 미치는 영향)

  • Ko, Jee-Yeon;Lee, Jae-Saeng;Woo, Koan-Sik;Song, Seok-Bo;Kang, Jong-Rae;Seo, Myung-Chul;Kwak, Do-Yeon;Oh, Byeong-Gun;Nam, Min-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.887-894
    • /
    • 2011
  • To evaluate the effects of abiotic factors of paddy fields on greenhouse gases (GHGs) emissions from rice paddy fields, $CH_4$ emission amounts were investigated from rice paddy fields by different soil organic matter contents, paddy types, and agricultural climatic zone in Yeongnam area during 3 years. $CH_4$ emission amounts according to soil organic matter contents in paddy field were conducted at having different contents of 5 soil organic matters fields (23.6, 28.7, 31.0, 34.5, and $38.0g\;kg^{-1}$), The highest $CH_4$ emission amount was recorded in the highest soil organic matters plot of $38.0g\;kg^{-1}$. High correlation coefficient (r=$0.963^{**}$) was obtained between $CH_4$ emissions from paddy fields and their soil organic matter contents. According to paddy field types, $CH_4$ emission amounts were investigated at 4 different paddy fields as wet paddy, sandy paddy, immature paddy, and mature paddy. The highest $CH_4$ emissions was recorded in wet paddy (100%) and followed as immature paddy 64.0%, mature paddy 46.8%, and sandy paddy 23.8%, respectively. For the effects of temperature on $CH_4$ emissions from paddy fields, 4 agricultural climatic zones were investigated, which were Yeongnam inland zone (YIZ), eastern coast of central zone (ECZ), plain area of Yeongnam inland mountainous zone (PMZ), and mountainous area of Yeongnam inland mountainous zone (MMZ). The order of $CH_4$ emission amounts from paddy fields by agricultural climatic zone were YIZ (100%) > ECZ (94.6%) > PMZ (91.6%) > MMZ (78.9%). The regression equation between $CH_4$ emission amounts from paddy fields and average air temperature of Jul. to Sep. of agricultural climatic zone was y = 389.7x-4,287 (x means average temperature of Jul. to Sep. of agricultural climatic zone, $R^2=0.906^*$)