• Title/Summary/Keyword: codes-of-practice

Search Result 185, Processing Time 0.027 seconds

A Classification and Coding System for the Design Information Management in Make-to-Order Manufacturing (수주생산에서의 설계정보 관리를 위한 부품분류와 코딩)

  • 이규용;김재균;문치웅
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.50
    • /
    • pp.195-207
    • /
    • 1999
  • Classification and Coding(C&C) systems as a core of design information management have been accomplished by many studies in terms of design and manufacturing attribute based on Group Technology. Those are very difficult to apply in make-to-order(MTO) manufacturing because the environment of MTO has various characteristics of product, many licensors, engineering change, insufficiency of integrated management system for codes and so on. This paper presents a suitable C&C system to MTO manufacturing which consider management level and drawing. The steps of developing the C&C system are as follows: 1) analysis of existing coding system and drawing type; 2) design of C&C system; 3) practice of designed coding system to a field.

  • PDF

Evaluation of the Applicability of FRP Grouted Reinforcing Method for Rock Slopes (암반사면에서 FRP 보강 그라우팅 공법의 적용성 평가)

  • Kim, Seong-Chan;Lee, Dal-Won
    • Korean Journal of Agricultural Science
    • /
    • v.35 no.2
    • /
    • pp.213-223
    • /
    • 2008
  • The instability of rock slopes caused by heavy rainfall and soil mass sliding needs the preventable and reinforcing method. The most important factor for the stability is the shear strength available in the planar part of the failure surface, which shows that a progressive failure takes place and a reinforcing of rock slope using FRP grout is effectively available. In this study, a grouting bolting interval predictions by limit equilibrium analysis and Matlab mathematical computer codes in several cases is presented for FRP reinforced rock slope. The proposed mathematical computer code can be easily applied for seeking properly FRP grout intervals prior to design and execute a reinforcement of a rock slope in practice.

  • PDF

Seismic behavior of non-seismically designed reinforced concrete frame structure

  • Nguyen, Xuan-Huy;Nguyen, Huy Cuong
    • Earthquakes and Structures
    • /
    • v.11 no.2
    • /
    • pp.281-295
    • /
    • 2016
  • This paper presents a study on a non-seismically designed reinforced concrete (RC) frame structure. The structure was a existing three-story office building constructed according to the 1990s practice in Vietnam. The 1/3 scaled down versions of structure was tested on a shake table to investigate the seismic performance of this type of construction. It was found that the inter-story drift and the overall behavior of structure meet the requirements of the actual seismic design codes. Then, nonlinear time history analyses are carried out using the fiber beam- column elements. The comparison between the experimental and simulation results shows the performance of the time history analysis models.

Characteristics of Live Load Effects on Bridges (하중효과를 고려한 차량하중 특성분석)

  • 김상효;박홍석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1992.04a
    • /
    • pp.126-133
    • /
    • 1992
  • The structural soundness of bridges is mainly damaged by overloaded heavy vehicles. The increasing volumes of overloaded heavy vehicles has been indicated as serious state. As results several countries have revised their bridge load codes. However, because of variety of truck types and their weights it is difficult to develop rational standard truck loads. In addition the common practice that only one design configuration of standard truck is adopted to design variety of bridges causes further difficulties. The objective of the study is to investigate the statistical characteristics of vehicle loadings based on survey data col looted, in which some major factors, such as vehicle configurations, vehicle freights, traffic modes, etc. are incorporated.

  • PDF

Seismic Analysis Models for Typical Roadway Bridges considering failure Mechanisms (파괴메카니즘을 고려한 일반도로교의 지진해석모델)

  • 국승규;김판배
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.295-301
    • /
    • 2001
  • For the seismic analysis of typical roadway bridges provisions are given in most codes for analysis models, which describes however only fundamental modelling methods according to the basic theories of structural dynamics. In practice even conventional non-seismic analysis models, separate super- and substructure models, are applied, which are not adequate because of neglecting connection elements. In this study three typical roadway bridges, a Steel box bridge, a PC beam bridge and a PC box bridge are selected and simple models integrating super- and substructure as well as connection elements are given. The simple models are composed with frame elements with lumped masses representing stiffness and mass characteristics of the selected bridges. To check the properness of the simple models, analysis results with the simple models are compared with those obtained with detailed models in view of bridge failure mechanisms. It is proved that the simple models can be used in the preliminary design phase fur the determination of failure mechanisms of typical roadway bridges.

  • PDF

Evaluation of seismic performance factors for steel DIAGRID structural system design

  • Lee, Dongkyu;Shin, Soomi;Ju, Youngkyu
    • Earthquakes and Structures
    • /
    • v.10 no.4
    • /
    • pp.735-755
    • /
    • 2016
  • This article presents a proposed analytical methodology to determine seismic force-resisting system R-values for steel diagrid framed systems. As current model building codes do not explicitly address the seismic design performance factors for this new and emerging structural system, the purpose of this study is to provide a sound and reliable basis for defining such seismic design parameters. An approach and methodology for the reliable determination of seismic performance factors for use in the design of steel diagrid framed structural systems is proposed. The recommended methodology is based on current state-of-the-art and state-of-the practice methods including structural nonlinear dynamic analysis techniques, testing data requirements, building code design procedures and earthquake ground motion characterization. In determining appropriate seismic performance factors (R, ${\Omega}_O$, $C_d$) for new archetypical building structural systems, the methodology defines acceptably low values of probability against collapse under maximum considered earthquake ground shaking.

Fuzzy inference based cover thickness estimation of reinforced concrete structure quantitatively considering salty environment impact

  • Do, Jeong-Yun
    • Computers and Concrete
    • /
    • v.3 no.2_3
    • /
    • pp.145-161
    • /
    • 2006
  • This article involves architecting prototype-fuzzy expert system for designing the nominal cover thickness by means of fuzzy inference for quantitatively representing the environment affecting factor to reinforced concrete in chloride-induced corrosion environment. In this work, nominal cover thickness to reinforcement in concrete was determined by the sum of minimum cover thickness and tolerance to that defined from skill level, constructability and the significance of member. Several variables defining the quality of concrete and environment affecting factor (EAF) including relative humidity, temperature, cyclic wet and dry, and the distance from coast were treated as fuzzy variables. To qualify EAF the environment conditions of cycle degree of wet-dry, relative humidity, distance from coast and temperature were used as input variables. To determine the nominal cover thickness a qualified EAF, concrete grade, and watercement ratio were used. The membership functions of each fuzzy variable were generated from the engineering knowledge and intuition based on some references as well as some international codes of practice.

Generalization of wind-induced interference effects for two buildings

  • Khanduri, Atul C.;Stathopoulos, Theodore;Bedard, Claude
    • Wind and Structures
    • /
    • v.3 no.4
    • /
    • pp.255-266
    • /
    • 2000
  • Wind-induced interference effects on a building are the result of one or more adjacent buildings modifying the flow of wind around it, which may result in a significant increase or decrease in wind loads on the building. Wind loading standards and codes of practice offer little guidance to the designer for assessing the effects of interference. Experimental results on interference effects indicate that code recommendations may be significantly low (unsafe) or uneconomically conservative. The paper presents results of an extensive experimental program to study the wind flow mechanisms and to quantify the extent of wind load modifications on buildings due to interference effects. These results have been simplified and presented from the point-of-view of design and codification for the case of two buildings. Based on these results, general guidelines and limiting conditions defining wind interference are formulated and discussed.

Wind pressure provisions for gable roofs of intermediate roof slope

  • Stathopoulos, Theodore;Wang, Kai;Wu, Hanqing
    • Wind and Structures
    • /
    • v.4 no.2
    • /
    • pp.119-130
    • /
    • 2001
  • The paper addresses the suitability of wind pressure coefficients specified in contemporary design standards and codes of practice for gable roofs of intermediate slope (roof angle $10^{\circ}-30^{\circ}$). In a recent research study, a series of low building models with different roof slopes in this intermediate range were tested in a boundary layer wind tunnel under simulated open country terrain conditions. This was different from the original study in the 70's, which produced the current provisions on the basis of a model tested only for a single roof slope (4:12) in this range. The results of the study suggest that a modification to the American wind provisions would be warranted to make them more representative of the true local and area-averaged wind loads imposed on gable roofs of intermediate slope.

Vehicle Load Effects on Slab of Parking Garage Structure (주차장 구조물 슬래브의 차량하중영향에 관한 연구)

  • 곽효경;송종영
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.04a
    • /
    • pp.131-138
    • /
    • 1997
  • The equivalent vehicle load factors which can consider the concentrated wheel load effect in slab design of parking garage structure are proposed. Based on the standard vehicle with total weight of 2.4 ton which is designed through the investigation of small to medium vehicle produced in Korea and the review of numerous foreign design codes for parking garage structure, the effects of moving vehicle loads on slab are analyzed using the finite element method. Besides. the relationships between the equivalent load factors and the sectional dimensions are established by regression analysis. The calculation of design forces can be easily accomplished without taking sophisticated numerical analysis for the moving vehicle load as the results obtained to the distributed load are multiplied by the proposed load factors in practice.

  • PDF