• Title/Summary/Keyword: coded excitation

Search Result 9, Processing Time 0.022 seconds

An Efficient Vocoder for Digital Cellular System (디지틀 셀룰라 시스템을 위한 효율적인 음성부호화 기술)

  • 강상원;이인성;한경호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.9
    • /
    • pp.1348-1357
    • /
    • 1993
  • In this paper, we present code-excited linear prediction coding using trellis coded vector excitation, termed trellis code-excited linear prediction coding (TCELP), for an efficient 8 kbps digital cellular vocoder. A training sequence-based algorithm is developed for designing an optimized codebook subject to the TCELP structure. Also, we discuss the encoding complexity of the TCELP system and trellis symbol release rules that avoid excessive encoding delay. finally, simulation results results for the TCELP coder are given at the bit rate of 8 kbps.

  • PDF

AN EFFICIENT TRELLIS EXCITATION SPEECH CODING AT 4.8 KBPS (효율적인 4.8 KBPS Trellis Exicitation 음성부호화방식)

  • 강상원
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06c
    • /
    • pp.210-213
    • /
    • 1994
  • In this paper, we present a combination of trellis coded vector quantization and code-excited linear prediction coding, termed trellis excitation coding, for an efficient 4.8 kbps speech coding system. A training sequence-based algorithm is developed for designing an otimized codebook subject to the TEC structure. Also, we discuss the trellis symbol release rules that avoid excessive encoding delay. Finally, simulation results for the TEC coder are given at bit rate of 4.8 kbps.

  • PDF

A 4800 BPS LPS Vocoder with Improved Exitation (개선된 여기신호의 4800BPS LPC 보코우터)

  • 은종관;성원용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.54-59
    • /
    • 1982
  • We present an improved 4800 bps LPC vocoder system that virtually eleminates the buzzy effect from synthetic speech. Excitation signal in the new system is formed by adding high-pass filtered pitch pulses or random noise to a baseband residual signal that has been coded by pitch predictive PCM. Since the baseband residual is used as a part of excitation, the system is also robust to V/UV and pitch errors. According to our informal listening tests, the synthetic speech of the new system does not have the buzzy effect. As a result the vocoder speech quality is more natural than that of a conventioinal LPC vocoder.

  • PDF

Vibration Analysis for IHTS Piping System of LMR Conveying Hot Liquid Sodium (고온소듐 내부유동을 갖는 액체금속로 중간열전달계통 배관에 대한 진동특성 해석)

  • Koo, Gyeong-Hoi;Lee, Hyeong-Yeon;Lee, Jae-Han
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.386-391
    • /
    • 2001
  • In this paper, the vibration characteristics of IHTS(Intermediate Heat Transfer System) piping system of LMR(Liquid Metal Reactor) conveying hot liquid sodium are investigated to eliminate the pipe supports for economic reasons. To do this, a 3-dimensional straight pipe element and a curved pipe element conveying fluid are formulated using the dynamic stiffness method of the wave approach and coded to be applied to any complex piping system. Using this method, the dynamic characteristics including the natural frequency, the frequency response functions, and the dynamic instability due to the pipe internal flow velocity are analyzed. As one of the design parameters, the vibration energy flow is also analyzed to investigate the disturbance transmission paths for the resonant excitation and the non-resonant excitations.

  • PDF

Adaptive TCX Windowing Technology for Unified Structure MPEG-D USAC

  • Lee, Tae-Jin;Beack, Seung-Kwon;Kang, Kyeong-Ok;Kim, Whan-Woo
    • ETRI Journal
    • /
    • v.34 no.3
    • /
    • pp.474-477
    • /
    • 2012
  • The MPEG-D unified speech and audio coding (USAC) standardization process was initiated by MPEG to develop an audio codec that is able to provide consistent quality for mixed speech and music contents. The current USAC reference model structure consists of frequency domain (FD) and linear prediction domain (LPD) core modules and is controlled using a signal classifier tool. In this letter, we propose an LPD single-mode USAC structure using an adaptive widowing-based transform-coded excitation module. We tested our system using official test items for all mono-evaluation modes. The results of the experiment show that the objective and subjective performances of the proposed single-mode USAC system are better than those of the FD/LPD dual-mode USAC system.

A Diagnostic Ultrasound Imaging System (초음파 영상진단장치)

  • Lee, Seong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.217-232
    • /
    • 1999
  • The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result. their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result. the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described.

  • PDF

Highband Coding Method Using Matching Pusuit Estimation and CELP Coding for Wideband Speech Coder (광대역 음성부호화기를 위한 매칭퍼슈잇 알고리즘과 CELP 방법을 이용한 고대역 부호화 방법)

  • Jeong Gyu-Hyeok;Ahn Yeong-Uk;Kim Jong-Hark;Shin Jae-Hyun;Seo Sang-Won;Hwang In-Kwan;Lee In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1
    • /
    • pp.21-29
    • /
    • 2006
  • In this Paper a split bandwidth wideband speech coder and its highband coding method are Proposed. The coder uses a split-band approach. where the wideband input speech signal is split into two equal frequency bands from 0-4kHz and 4-8kHz. The lowband and the highband are coded respectively by the 11.8kb/s G.729 Annex E and the proposed coding method. After the LPC analysis, the highband is divided by two modes according to the properties of signals. In stationary mode. the highband signals are compressed by the mixture excitation model; CELP algorithm and W (Matching Pursuit) algorithm. The others are coded by the only CELP algorithm. We compare the performance of the new wideband speech coder with that of G.722 48kbps SB-ADPCM and G.722.2 12.85kbps in a subjective method. The simulation results show that the Performance of the proposed wideband speech coder has better than that of 48kbps G.722 and no better than that of 12.85kbps G.722.2.

Optimized Sigma-Delta Modulation Methodology for an Effective FM Waveform Generation in the Ultrasound System (효율적인 주파수 변조된 초음파 파형 발생을 위한 최적화된 시그마 델타 변조 기법)

  • Kim, Hak-Hyun;Han, Ho-San;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.429-440
    • /
    • 2007
  • A coded excitation has been studied to improve the performance for ultrasound imaging in term of SNR, imaging frame rate, contrast to tissue ratio, and so forth. However, it requires a complicated arbitrary waveform transmitter for each active channel that is typically composed of a multi-bit Digital-to-Analog Converter (DAC) and a linear power amplifier (LPA). Not only does the LPA increase the cost and size of a transmitter block, but it consumes much power, increasing the system complexity further and causing a heating-up problem. This paper proposes an optimized 1.5bit fourth order sigma-delta modulation technique applicable to design an efficient arbitrary waveform generator with greatly reduced power dissipation and hardware. The proposed SDM can provide a required SQNR with a low over-sampling ratio of 4. To this end, the loop coefficients are optimized to minimize the quantization noise power in signal band while maintaining system stability. In addition, the decision level for the 1.5 bit quantizer is optimized for a given input waveform, which results in the SQNR improvement of more than 5dB. Computer simulation results show that the SQNR of a FM(frequency modulated) signal generated by using the proposed method is about 26dB, and the peak side-lobe level (PSL) of its compressed waveform on receive is -48dB.

Multiple Transmit Focusing Method With Modified Orthogonal Golay Codes for Ultrasound Imaging (초음파 영상에서 변형된 직교 골레이 코드를 이용한 동시 다중 송신 집속 기법)

  • 김배형;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.217-231
    • /
    • 2003
  • Coded excitation with complementary Golay sequences is an effective means to increase the SNR and penetration of ultrasound imaging. in which the two complementary binary codes are transmitted successively along each scan-line, reducing the imaging frame rate by half. This method suffers from low frame rate particularly when multiple transmit focusing is employed, since the frame rate will be further reduced in proportion to the number of focal zones. In this paper. a new ultrasound imaging technique based on simultaneous multiple transmit focusing using modified orthogonal Golay codes is proposed to improve lateral resolution with no accompanying decrease in the imaging frame rate, in which a pair of orthogonal Golay codes focused at two different focal depths are transmitted simultaneously. On receive, these modified orthogonal Golay codes are separately compressed into two short pulses and individually focused. These two focused beams are combined to form a frame of image with improved lateral resolution. The Golay codes were modified to improve the transmit power efficiency (TPE) for practical imaging. Computer simulations and experimental results show that the proposed method improves significantly the lateral resolution and penetration of ultrasound imaging compared with the conventional method.