• Title/Summary/Keyword: code evaluation

Search Result 1,466, Processing Time 0.025 seconds

Extraction and classification of characteristic information of malicious code for an intelligent detection model (지능적 탐지 모델을 위한 악의적인 코드의 특징 정보 추출 및 분류)

  • Hwang, Yoon-Cheol
    • Journal of Industrial Convergence
    • /
    • v.20 no.5
    • /
    • pp.61-68
    • /
    • 2022
  • In recent years, malicious codes are being produced using the developing information and communication technology, and it is insufficient to detect them with the existing detection system. In order to accurately and efficiently detect and respond to such intelligent malicious code, an intelligent detection model is required, and in order to maximize detection performance, it is important to train with the main characteristic information set of the malicious code. In this paper, we proposed a technique for designing an intelligent detection model and generating the data required for model training as a set of key feature information through transformation, dimensionality reduction, and feature selection steps. And based on this, the main characteristic information was classified by malicious code. In addition, based on the classified characteristic information, we derived common characteristic information that can be used to analyze and detect modified or newly emerging malicious codes. Since the proposed detection model detects malicious codes by learning with a limited number of characteristic information, the detection time and response are fast, so damage can be greatly reduced and Although the performance evaluation result value is slightly different depending on the learning algorithm, it was found through evaluation that most malicious codes can be detected.

Process Standardization for the Construction of Job-Exposure Matrix Using the Work Environment Measurement Database (작업환경측정 결과 데이터베이스를 활용한 직무노출매트릭스 구축을 위한 공정 표준화)

  • Sangjun Choi;Ju-Hyun Park;Dong-Hee Koh;Donguk Park;Hwan-Cheol Kim;Dae Sung Lim;Yeji Sung;Kyoung Yoon Ko;Ji Seon Lim;Hoekyeong Seo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.78-90
    • /
    • 2023
  • Objectives: The purpose of this study is to standardize the process code of the work environment measurement database (WEMD) for the construction of a job-exposure matrix (JEM). Methods: The standard process code (SPC) was reclassified based on process similarity and drawing upon the code used in the existing K2B. It was supplemented through review by industrial hygiene experts. In addition, an index word database related to SPC was created and used for SPC search. A pilot evaluation project was conducted by experts to evaluate the validity of the newly reclassified standard process code. Results: A total of 70 final SPCs were developed, including 31 processes related to the construction industry. Using the Shiny program, we developed a standard code finder that can be used on the web (https://kscf.shinyapps.io/scf_app/). As a result of the pilot evaluation, it was determined that it was easier to search for standard codes than previous codes, so it was highly utilized. Conclusions: It is expected that JEM construction using industry-process information drawing on WEMD data will be possible using the 70 newly standardized process codes.

An Evaluation of ACI 349 Code for Shear Design of CIP Anchor (직매형 앵커기초의 전단설계를 위한 ACI 349 Code의 평가)

  • Jang Jung-Bum;Hwang Kyeong-Min;Suh Yong-Pyo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.464-470
    • /
    • 2005
  • The numerical analysis is carried out to identify the influence of design factors to shear capacity of cast-in-place (CIP) anchor in ACI 349 Code that is available for the design of fastening system at Nuclear Power Plant (NPP) in this study. The MASA program is used to develop the numerical analysis model and the developed numerical analysis model is verified on a basis of the various test data of CIP anchor. Both $l/d_o$ and $c_1/l$ we considered as design factors. As a result, the variation of $l/d_o$ has no influence on the shear capacity of CIP anchor but $c_1/l$ has a large influence on the shear capacity of CIP anchor, Therefore, it is proved that ACI 349 Code may give a non-conservative results compared with real shear capacity of CIP anchor according to $c_1/l$.

  • PDF

MIDLOOP Code Analysis of a ROSA-IV/LSTF Experiment for the Loss of Residual Heat Removal System Event During Mid- loop Operation

  • Han, Kee-Soo;Lee, Cheol-Sin;Park, Chul-Jin;Kim, Hee-Cheol
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.683-690
    • /
    • 1996
  • The MIDLOOP code has been developed for the evaluation of RES pressurization transients initiated from a loss-of-Residual Heat Removal System (RHRS) during mid-loop operation after reactor shutdown. It provides a fast running and realistic tool for studying parametrically the response of important plant parameters such as pressure, temperature, and level to various plant combinations of the primary side vent, makeup, and leakage procedures and the steam generator (SG) conditions. The code consists of ten nodes representing the primary and secondary sides of a nuclear power plant and can analyze the effect of air on the primary system pressurization and primary to secondary heat transfer. The analysis results of the MIDLOOP code are in good agreement with the ROSA-IV/LSTF experiment without opening in the RCS.

  • PDF

Performance Evaluation of Speech Coder for Digital Mobile Communication System in Radio Channel Environment (무선 채널 환경에서 디지털 이동통신용 음성 부호화기의 성능 평가)

  • 김형중;윤병식;최송인
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.1 no.1
    • /
    • pp.77-83
    • /
    • 1997
  • In this paper, we present a comparison between QCELP(Qualcomm Code Excited Linear Predictor) speech coder that is operating in digital mobile communication system and CS-ACELP(Conjugate Structure Algebraic Code Excited Linear Prediction) speech coder that is scheduled to use for IMT-2000 (International Mobile Telecommunications 2000) system. The performance comparison might give help to design of the speech coding algorithms so that the robustness of the algorithms to channel errors engaged by mobile communication system be optimized.

  • PDF

Design of 5kW-class Horizontal Axis Wind Turbine using In-house Code POSEIDON (In-house 코드 POSEIDON을 이용한 5kW급 수평축 풍력발전용 로터 블레이드 형상설계)

  • Kim, Ki-Pyoung;Kim, Ill-Soo;Choi, Young-Do;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.492-492
    • /
    • 2009
  • Nowadays in Republic of Korea, there is no distinct reference for the related design technology of rotor blade of wind turbine. Therefore the optimum design and evaluation of performance is carried out with foreign commercial code softwares. This paper shows in-house code software that evaluates the aerodynamic design of wind turbine rotor blade using blade element-momentum theory (BEMT) and processes that is applied through various aerodynamics theories such as momentum theory, blade element theory, prandtl's tip loss theory and strip theory. This paper presents the results of the numerical analysis such as distribution of aerodynamic properties and performance curves using in-house code POSEIDON.

  • PDF

A Study on Sunshine Environment with Different Distance between Buildings (인동간격에 따른 일조환경에 대한 연구)

  • 최용석;최지혜;김용식
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • Apartment design in residential Area is restricted by building distance limit code. Building distance limit decreases gradually to the 0.8H(height), and residential area has 250% site area ratio by building code, so site using has become efficient. In this study, examine the relationship between present building distance limit and right of daylighting environment by computer simulation. As well, high-rise residential officetel and multipurpose residential building becomes increase in commercial non-residential area. In the domestic, residential type multipurpose building made at the business area or central business area has 400∼800% site area ratio by building code. However, at a dweller's point of view, there are much lacks of environmental consideration to provide suitable daylighting environment. And, POE: Post Occupancy Evaluation is not completed yet. In this study, however, progress architectural environment prediction, basis by right of daylighting, and examine the possibility of daylighting by architectural distance limit code in residental area and by high-rise, high-density residential building in non-residental downtown area.

Development and Evaluation of Startup Simulation Code for an Open Cycle Liquid Rocket Engine (개방형 사이클 액체로켓엔진 시동해석 코드 개발 및 평가)

  • Jung, Taekyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.5
    • /
    • pp.67-74
    • /
    • 2019
  • In this paper, mathematical models of a simulation code are presented. The simulation code was developed for the startup analysis of an open cycle liquid rocket engine (LRE). Most of the components comprising an LRE, including the priming process in the propellant feeding line, were considered. A startup simulation of a 75-tonf LRE, which was used for the KSLV-II test launch vehicle (TLV), was performed. The simulation results showed good agreement with the engine acceptance test results, thus proving the validity of the startup simulation code.

Assessment of seismic design coefficients for composite special moment frames with reinforced concrete columns and steel beams: Evaluation of code recommendations

  • Elmira Tavasoli Yousef Abadi;Mohammad T. Kazemi
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.643-658
    • /
    • 2024
  • The main aim of this study is to quantify the code seismic design coefficients of the RCS system, which consisted of reinforced concrete columns and steel beams, based on the FEMA P-695 methodology. The underlying intention is to evaluate the seismic performance of the RCS system at the system level rather than the connection level. A set of 24 archetype buildings with a various number of stories, beam span lengths, gravity load levels, and seismic load levels are selected and designed based on the prevailing code requirements. Nonlinear analytical models are developed and validated by experimental tests. The pushover and response history dynamic analyses are conducted to evaluate the required data in the performance quantification process. The results show that the design coefficients suggested by the code are acceptable. However, the level of conservatism is very high. Thus, it is possible to use a larger R-factor in the design process or make some relaxations in the design requirements related to this structural system.

Study of the Distribution Properties and LRFD Code Conversion in Japanese Larch

  • Park, Chun-Young;Pang, Sung-Jun;Park, Ju-Sang;Kim, Kwang-Mo;Park, Mun-Jae;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.94-100
    • /
    • 2010
  • This study was performed to develop an LRFD (Load Resistance Factored Design) Code for Domestic Larch. To accomplish his, we evaluated bending, compression, tension and shear strength. The results of the strength evaluation were utilized to verify the distribution and code conversion. For bending, tension and compressive strength, the Weibull distribution was well-fitted, but for shear strength we observed a normal distribution. For evaluating the bending and compressive strength, a full-sized specimen was used. A small clear specimen was used to test tension and shear strength. Compressive strength in particular was found to be affected by tight knots, although there was little difference between grades. In the code conversion, the design value of the LRFD was larger than the existing allowable stress value in the Korean Building Code. However, the allowable stress in this study was about two times higher than the value listed in the Korean Building Code. This result induced the difference between the soft and hard conversions. For greater reliability, the accumulation of additional data is necessary and further studies should be performed