• Title/Summary/Keyword: code conversion

Search Result 262, Processing Time 0.032 seconds

A Study on the Performance of an 100 kW Class Tidal Current Turbine (100 kW급 조류발전용 터빈의 성능에 관한 연구)

  • Kim, Bu-Gi;Yang, Chang-Jo;Choi, Min-Seon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.2
    • /
    • pp.145-152
    • /
    • 2012
  • As the problems of global warming are brought up recently, many skillful solutions for developing new renewable energy are suggested. One of the most remarkable things is ocean energy. Korea has abundant ocean energy resources owing to geographical characteristics surrounded by sea on three sides, thus the technology of commercialization about tidal current power, wave power is demanded. Especially, Tidal energy conversion system is a means of maintaining environment naturally. Tidal current generation is a form to produce electricity by installing rotors, generators to convert a horizontal flow generated by tidal current into rotating movement. According to rotor direction, a tidal current turbine is largely distinguished between horizontal and vertical axis shape. Power capacity depends on the section size crossing a rotor and tidal current speed. We therefore investigated three dimensional flow analysis and performance evaluation using commercial ANSYS-CFX code for an 100 kW class horizontal axis turbine for low water level. Then We also studied three dimensional flow characteristics of a rotating rotor and blade surface streamlines around a rotor. As a result, We found that torque increased with TSR, the maximum torque occurred at TSR 3.77 and torque decreased even though TSR increased. Moreover we could get power coefficient 0.38 at designed flow velocity.

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF

A Study on the Improvement of Domestic Medical Device Product Classification through Analysis of Medical Device Classification System in the U.S. and Europe (미국 및 유럽 의료기기 품목분류 체계 분석을 통한 국내 의료기기 품목분류 개선 연구)

  • Kang Hyeon, You;Ji Min, Son;Gyeong Min, Kwon;You Rim, Kim;Hui Sung, Lee;Won Seuk, Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.73-79
    • /
    • 2023
  • The purpose of this study is to derive medical devices with different management systems through comparison of domestic and overseas medical device product classification systems and to propose management conversion measures for the products. The definitions of medical devices were compared and the scope of medical devices defined by each country was confirmed through surveys of the Medical Device Act, Federal Food, Drug & Cosmetics Act (FD&C) in the U.S., and Medical Device Regulations (MDR) in Europe. Using the Ministry of Food and Drug Safety's regulations on medical device products and grades, 21 CFR part 860-892 and product code classification files in U.S., and EMDN in Europe as basic data to compare medical device products and derive medical devices with different management systems. As a result of comparing the definition and product classification systems of medical devices in Korea, the U.S. and Europe, medical device accessories, prosthetic limbs and aids among assistive devices for persons with disabilities, drugs, quasi-drugs and industrial products that are not managed by medical devices in Korea are managed as medical devices in the U.S. and Europe. This study aims to improve public health by securing systematic product safety management and essential performance under medical device regulations. Management within a single medical device system will increase the efficiency of licensing work of domestic medical device manufacturers and related organizations. It is also expected to help advance the system according to the international harmony of the item classification system and enhance smooth import and export competitiveness.

Cataloging Trends after LRM and its Acceptance in KORMARC Bibliographic Format (LRM 이후 목록 동향과 KORMARC 통합서지용에서의 수용 방안)

  • Lee, Mihwa;Lee, Eun-Ju;Rho, Jee-Hyun
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.33 no.1
    • /
    • pp.25-45
    • /
    • 2022
  • This study was to develop KORMARC-bibliographic format reflecting cataloging trends after LRM using literature review, analysis of MARC 21 discussion papers, and comparison of the fields in MARC 21 and KORMARC. The acceptance and consideration of fields and sub-fields that need to be revised in KORMARC are as follows. First, in terms of LRM / RDA, fields 381 or 387 for the representative expression, field 881 and the change and addition of its sub-fields for the manifestation statement, and data provenance code to ▾7 sub-field for date provenance may be considered. Second, in terms of Linked Data, ▾1 sub-field for RWO, and field 758 for related work identifier can be added. Third, for the data exchange of KORMARC and BIBFRAME, it should be developed in consideration of mapping with BIBFRAME classes and attributes in KORMARC. Fourth, additional fields such as 251 version information, 334 mode of issuance, 335 expansion plan, 341 accessibility content, 348 format of notated music, 353 supplementary content characteristics, 532 accessibility note, 370 associated place, 385 audience characteristics, 386 creator/contributor characteristics, 388 time period of creation, 688 subject added entry-type of entity unspecified, 884 description conversion information, 885 matching information could be developed. This study will be used to revise KORMARC-bibliographic format and to build and utilize bibliographic data in domestic libraries.

Computational Fluid Dynamics Study of Channel Geometric Effect for Fischer-Tropsch Microchannel Reactor (전산유체역학을 이용한 Fischer-Tropsch 마이크로채널 반응기의 채널 구조 영향 분석)

  • Na, Jonggeol;Jung, Ikhwan;Kshetrimayum, Krishnadash S.;Park, Seongho;Park, Chansaem;Han, Chonghun
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.826-833
    • /
    • 2014
  • Driven by both environmental and economic reasons, the development of small to medium scale GTL(gas-to-liquid) process for offshore applications and for utilizing other stranded or associated gas has recently been studied increasingly. Microchannel GTL reactors have been prefrered over the conventional GTL reactors for such applications, due to its compactness, and additional advantages of small heat and mass transfer distance desired for high heat transfer performance and reactor conversion. In this work, multi-microchannel reactor was simulated by using commercial CFD code, ANSYS FLUENT, to study the geometric effect of the microchannels on the heat transfer phenomena. A heat generation curve was first calculated by modeling a Fischer-Tropsch reaction in a single-microchannel reactor model using Matlab-ASPEN integration platform. The calculated heat generation curve was implemented to the CFD model. Four design variables based on the microchannel geometry namely coolant channel width, coolant channel height, coolant channel to process channel distance, and coolant channel to coolant channel distance, were selected for calculating three dependent variables namely, heat flux, maximum temperature of coolant channel, and maximum temperature of process channel. The simulation results were visualized to understand the effects of the design variables on the dependent variables. Heat flux and maximum temperature of cooling channel and process channel were found to be increasing when coolant channel width and height were decreased. Coolant channel to process channel distance was found to have no effect on the heat transfer phenomena. Finally, total heat flux was found to be increasing and maximum coolant channel temperature to be decreasing when coolant channel to coolant channel distance was decreased. Using the qualitative trend revealed from the present study, an appropriate process channel and coolant channel geometry along with the distance between the adjacent channels can be recommended for a microchannel reactor that meet a desired reactor performance on heat transfer phenomena and hence reactor conversion of a Fischer-Tropsch microchannel reactor.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Prevalence of Enteyobius vermiculuris infection and preventive effects of masts treatment among children in rural and urban areas, and children in orphanages (농촌, 도시 및 집단생활 아동의 요충 감염과 집단 구충에 의한 예방 효과)

  • Kim, Jong-Su;Lee, Hae-Yong;An, Yeong-Gyeom
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.3
    • /
    • pp.235-244
    • /
    • 1991
  • An epidemiological study and mass treatments of Enterobius vermicularis infection among children near Wonju area of Kangwon province were carried out. The children were divided into 4 groups according to their residing localities; children in the mountainous area, rural area, urban area and in orphanage. They were examined by adhesive cellotape anal swab technique, and egg positive rates were obtained. The rates of egg reduction and re-infection rates after repeated mass treatments were also observed. The results obtained were as follows: 1. The overall egg Positive rate of E. vermicularis in the first screening was 19.9% (251 out of 1, 262 examinees; 19.7% in males and 20.1% in females). The positive rates were 13.0% in the mountainous area, 11 9% in the rural area, 15.1% in the urban (medium-sized) area and 61.9% in orphanages. 2. The highest positive rates were observed in the kindergarten children, and 1st and 2nd grade children of primary schools (26.2~32.2%), and the lowest rate (13.6%) in 6-year grade children of primary schools. 3. Cumulative detection rates from 3 repeated anal swabs at 4~5 days interval were higher (70.8%) than those from single anal swabs (50.0~59.2%). 4. Out of the examinees who showed the highest cumulative positive rate (70.8%), about 39.2% were consecutively positive in 3 anal swabs. Among different groups of children, the higher the total egg detection rates (87.5%), the higher the consecutive positive rates (71.9%) . 5. A total of 2, 609 (male : female=1 : 12.4) worms were collected from 17 egg-positive cases treated with anthelinintics. The mean number of worms per child was 153 (range: 4-824) . 6. The egg-positive cases in several studied groups (180 children) were treated with anthelmintics 6 times at 3-week intervals. In this case, the overall positive rate was decreased from 54.8% to 2.2% at 15 weeks after the treatments, but no complete negative conversion was experienced. However, in a group of children (154 children) including egg Positive and negative cases who were both treated with anthelmintics at 3-week interval, a complete egg-negative conversion was observed in the 9th week after treatments. 7. The egg-detection rate in the brothers or sisters of egg Positive children was 70.0% (28 out of 40 examined), and the egg-positive rate according to the family unit was 69.7%. In summarizing the above results, it is concluded that Enterobius vermicularis infection is still highly prevalent among children in Korea, and that repeated mass treatments of more than 3 times will be effective for control of this infection.

  • PDF

The Current Status of the Warsaw Convention and Subsequent Protocols in Leading Asian Countries (아시아 주요국가(主要國家)들에 있어서의 바르샤바 체제(體制)의 적용실태(適用實態)와 전망(展望))

  • Lee, Tae-Hee
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.1
    • /
    • pp.147-162
    • /
    • 1989
  • The current status of the application and interpretation of the Warsaw Convention and its subsequent Protocols in Asian countries is in its fredgling stages compared to the developed countries of Europe and North America, and there is thus little published information about the various Asian governments' treatment and courts' views of the Warsaw System. Due to that limitation, the accent of this paper will be on Korea and Japan. As one will be aware, the so-called 'Warsaw System' is made up of the Warsaw Convention of 1929, the Hague Protocol of 1955, the Guadalajara Convention of 1961, the Guatemala City Protocol of 1971 and the Montreal Additional Protocols Nos. 1,2,3 and 4 of 1975. Among these instruments, most of the countries in Asia are parties to both the Warsaw Convention and the Hague Protocol. However, the Republic of Korea and Mongolia are parties only to the Hague Protocol, while Burma, Indonesia and Sri Lanka are parties only to the Warsaw Convention. Thailand and Taiwan are not parties only to the convention or protocol. Among Asian states, Indonesia, the Phillipines and Pakistan are also parties to the Guadalajara Convention, but no country in Asia has signed the Guatemala City Protocol of 1971 or the Montreal Additional Protocols, which Protocols have not yet been put into force. The People's Republic of China has declared that the Warsaw Convention shall apply to the entire Chinese territory, including Taiwan. 'The application of the Warsaw Convention to one-way air carriage between a state which is a party only to the Warsaw Convention and a state which is a party only to the Hague Protocol' is of particular importance in Korea as it is a signatory only to the Hague Protocol, but it is involved in a great deal of air transportation to and from the united states, which in turn is a party only to the Warsaw Convention. The opinion of the Supreme Court of Korea appears to be, that parties to the Warsaw Convention were intended to be parties to the Hague Protocol, whether they actually signed it or not. The effect of this decision is that in Korea the United States and Korea will be considered by the courts to be in a treaty relationship, though neither State is a signatory to the same instrument as the other State. The first wrongful death claim in Korea related to international carriage by air under the Convention was made in Hyun-Mo Bang, et al v. Korean Air Lines Co., Ltd. case. In this case, the plaintiffs claimed for damages based upon breach of contract as well as upon tort under the Korean Civil Code. The issue in the case was whether the time limitation provisions of the Convention should be applicable to a claim based in tort as well as to a claim based in contract. The Appellate Court ruled on 29 August 1983 that 'however founded' in Article 24(1) of the Convention should be construed to mean that the Convention should be applicable to the claim regardless of whether the cause of action was based in tort or breach of contract, and that the plaintiffs' rights to damages had therefore extinguished because of the time limitation as set forth in Article 29(1) of the Convention. The difficult and often debated question of what exactly is meant by the words 'such default equivalent to wilful misconduct' in Article 25(1) of the Warsaw Convention, has also been litigated. The Supreme Court of Japan dealt with this issue in the Suzuki Shinjuten Co. v. Northwest Airlines Inc. case. The Supreme Court upheld the Appellate Court's ruling, and decided that 'such default equivalent to wilful misconduct' under Article 25(1) of the Convention was within the meaning of 'gross negligence' under the Japanese Commercial Code. The issue of the convention of the 'franc' into national currencies as provided in Article 22 of the Warsaw Convention as amended by the Hague Protocol has been raised in a court case in Korea, which is now before the District Court of Seoul. In this case, the plaintiff argues that the gold franc equivalent must be converted in Korean Won in accordance with the free market price of gold in Korea, as Korea has not enacted any law, order or regulation prescribing the proper method of calculating the equivalent in its national currency. while it is unclear if the court will accept this position, the last official price of gold of the United States as in the famous Franklin Mint case, Special Drawing Right(SDR) or the current French franc, Korean Air Lines has argued in favor of the last official price of gold of the United States by which the air lines converted such francs into us Dollars in their General Conditions of Carriage. It is my understanding that in India, an appellate court adopted the free market price valuation. There is a report as well saying that if a lawsuit concerning this issue were brought in Pakistan, the free market cost of gold would be applied there too. Speaking specifically about the future of the Warsaw System in Asia though I have been informed that Thailand is actively considering acceding to the Warsaw Convention, the attitudes of most Asian countries' governments towards the Warsaw System are still wnot ell known. There is little evidence that Asian countries are moving to deal concretely with the conversion of the franc into their own local currencies. So too it cannot be said that they are on the move to adhere to the Montreal Additional Protocols Nos. 3 & 4 which attempt to basically solve many of the current problems with the Warsaw System, by adopting the SDR as the unit of currency, by establishing the carrier's absolute liability and an unbreakable limit and by increasing the carrier's passenger limit of liability to SDR 100,000, as well as permiting the domestic introduction of supplemental compensation. To summarize my own sentiments regarding the future, I would say that given the fact that Asian air lines are now world leaders both in overall size and rate of growth, and the fact that both Asian individuals and governments are becoming more and more reliant on the global civil aviation networks as their economies become ever stronger, I am hopeful that Asian nations will henceforth play a bigger role in ensuring the orderly and hasty development of a workable unified system of rules governing international commercial air carriage.

  • PDF

Release Characteristics of Fission Gases with Spent Fuel Burn-up during the Voloxidation and OREOX Processes (사용후핵연료의 연소도 변화에 따른 산화 및 OREOX 공정에서 핵분열기체 방출 특성)

  • Park, Geun-Il;Cho, Kwang-Hun;Lee, Jung-Won;Park, Jang-Jin;Yang, Myung-Seung;Song, Kee-Chan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.39-52
    • /
    • 2007
  • Quantitative analysis on release behavior of the $^{85}Kr\;and\;^{14}C$ fission gases from the spent fuel material during the voloxidation and OREOX process has been performed. This thermal treatment step in a remote fabrication process to fabricate the dry-processed fuel from spent fuel has been used to obtain a fine powder The fractional release percent of fission gases from spent fuel materials with burn-up ranges from 27,000 MWd/tU to 65,000 MWd/tU have been evaluated by comparing the measured data with these initial inventories calculated by ORIGEN code. The release characteristics of $^{85}Kr\;and\;^{14}C$ fission gases during the voloxidation process at $500^{\circ}C$ seem to be closely linked to the degree of conversion efficiency of $UO_2\;to\;U_3O_8$ powder, and it is thus interpreted that the release from grain-boundary would be dominated during this step. The high release fraction of the fission gas from an oxidized powder during the OREOX process would be due to increase both in the gas diffusion at a temperature of $500^{\circ}C$ in a reduction step and in U atom mobility by the reduction. Therefore, it is believed that the fission gases release inventories in the OREOX step come from the inter-grain and inter-grain on $UO_2$ matrix. It is shown that the release fraction of $^{85}Kr\;and\;^{14}C$ fission gases during the voloxidation step would be increased as fuel burn-up increases, ranging from 6 to 12%, and a residual fission gas would completely be removed during the OREOX step. It seems that more effective treatment conditions for a removal of volatile fission gas are of powder formation by the oxidation in advance than the reduction of spent fuel at the higher temperature.

  • PDF

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF