• 제목/요약/키워드: coating amount

검색결과 588건 처리시간 0.023초

Preparation and Characterization of Sol-Gel Derived $SiO_2-TiO_2$ -PDMS Composite Films

  • 황진명;여창선;김유항
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권12호
    • /
    • pp.1366-1370
    • /
    • 2001
  • Thin films of the SiO2-TiO2-PDMS composite material have been prepared by the sol-gel dip coating method. Acid catalyzed solutions of tetraethoxy silane (TEOS) and polydimethyl siloxane (PDMS) mixed with titanium isopropoxide Ti(OiPr) were used as precursors. The optical and structural properties of the organically modified 70SiO2-30TiO2 composite films have been investigated with Fourier Transform Infrared Spectroscopy (FT-IR), UV-Visible Spectroscopy (UV-Vis), Differential Thermal Analysis (DTA) and prism coupling technique. The films coated on the soda-lime-silicate glass exhibit 450-750 nm thickness, 1.56-1.68 refractive index and 88-94% transmittance depending on the experimental parameters such as amount of PDMS, thermal treatment and heating rate. The optical loss of prepared composite film was measured to be about 0.34 dB/cm.

Surface Characterization and Morphology in Ar-Plasma-Treated Polypropylene Blend

  • Weon, Jong-Il;Choi, Kil-Yeong
    • Macromolecular Research
    • /
    • 제17권11호
    • /
    • pp.886-893
    • /
    • 2009
  • Surface modifications using a radio frequency Ar-plasma treatment were performed on a polypropylene (PP) blend used for automotive bumper fascia. The surface characterization and morphology were examined. With increasing aging time, there was an increase in wettability, oxygen containing polar functional groups (i.e., C-O, C=O and O-C=O) due to oxidation, the amount of tale, and bearing depth and roughness on the PP surface, while there was a decrease in the number of hydrocarbon groups (i.e., C-C and C-H). AFM indicated that the Ar-plasma-treatment on a PP blend surface transforms the wholly annular surface into a locally dimpled surface, leading to an improvement in wettability. SEM showed that the PP layer observed in the non-plasma-treated sample was removed after the Ar-plasma treatment and the rubber particles were exposed to the surface. The observed surface characterization and morphologies are responsible for the improved wettability and interfacial adhesion between the PP blend substrate and bumper coating layers.

은 나노 와이어 전극을 이용한 ZnS:Cu, Mn 전계발광소자 (Transparent ZnS:Cu, Mn Powder Electroluminescent Device Using AgNW Electrode)

  • 정현지;김종수;김광철
    • 반도체디스플레이기술학회지
    • /
    • 제20권2호
    • /
    • pp.73-76
    • /
    • 2021
  • This thesis described the optical and electrical properties of the alternating current powder electroluminescent device based on Ag nanowire as a transparent electrode. The Ag nanowire electrode showed the morphology of 20 nm in diameter and 15 ㎛ in length. The transparent electroluminescent devices that were fabricated using the nanomilled ZnS : Cu, Mn phosphor by bar-coating process showed the transmittance of 67%. In order to improve the luminous efficiency, it is necessary to apply the transparent dielectric layer and increase the amount of the nanophosphor while maintaining the transmittance.

전기도금법을 이용한 퍼멀로이-실리카 복합도금 (Electrodeposition of Permalloy-Silica Composite Coating)

  • 정명원;김종훈;이흥렬;이재호
    • 마이크로전자및패키징학회지
    • /
    • 제17권4호
    • /
    • pp.83-88
    • /
    • 2010
  • 복합전기도금은 도금 중 반응성이 없는 물질을 첨가하여 도금층 내부에 함께 존재하도록 함으로써 이루어진다. 퍼멀로이는 철과 니켈의 합금을 말하는 것으로써 높은 투자율를 나타내기 때문에 산업 여러 분야에 응용된다. 복합도금을 통해 제품의 미세경도를 향상시킬 수 있으며 이는 제품의 수명과 연관된다. 하지만 실리카 나노분말 표면의 수산화기는 표면을 수분에 취약하게 만들고 이는 나노분말의 응집을 발생시켜 균일한 도금층의 형성을 어렵게 하는 요인이 된다. 본 연구에서는 실리카 나노분말의 응집을 줄이기 위하여 첨가제의 변화, 초음파 처리 시간의 변화를 살펴보았다. 초음파 처리시간의 증가시 입자의 분산효과가 좋았고 조성의 변화가 발생하였다. 첨가제에 따라 표면 형상과 공석되는 실리카 나노입자의 함량 차이가 나타났다. 염기성 도금용액에서 sodium lauryl sulfate를 사용하였을 경우 표면이 매끄럽고 공석되는 실리카 나노분말의 양도 높았다.

에폭시 수지 용출물질에서의 내분비계장애물질 Bisphenol-A의 정량과 용출특성 파악 (A Study on the Quantification and Chracterization of Endocrine Disruptor Bisphenoi-A Leaching from Epoxy Resin)

  • 배범한;최명수;임남웅;정재훈
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.469-477
    • /
    • 2000
  • Bisphenol-A (BPA), a known endocrine disruptor, is a main building block of epoxy resin which is widely used as a coating agent in residential water storage tanks. Therefore, BPA leaching from the epoxy resin may have adverse effects on human health. The possibility of BPA leaching from three epoxy resins were tested with a modified KS D 8502 method at 20, 50, 75 and $100^{\circ}C$ in deionized water and the specified test water, respectively. BPA leached to the test water was identified using GC-MS and quantified with GC-FID after a sequential extraction and concentration. The results showed that BPA leaching has occurred in all three samples tested. The quantify of BPA leaching from unit area of epoxy resin coating was in the range of $10.677{\sim}273.120{\mu}g/m^2$ for sample A, 29.737~1734.045 for sample B and 52.857~548.778 for sample C depending on the test temperature, respectively. In general, the amount of BPA leaching increased as the water temperature increases. This result implies a higher risk of BPA leaching to drinking water during a hot summer season. In addition, microbial growth, measured by colony forming units, in epoxy coated water tanks was higher than that in a stainless steel tank suggesting that compounds leaching from epoxy resin may support the growth of microorganisms in a residential water holding tank.

  • PDF

은이 피복된 단심 Bi(2223) 초전도 선재에 대한 SrZrO3 코팅층의 접착강도 특성 (Bond Strength of SrZrO3 Coatings on Ag Sheathed Bi(2223) Mono-core Tape)

  • 이세종;예경환;이득용;송요승
    • 한국세라믹학회지
    • /
    • 제39권10호
    • /
    • pp.1001-1006
    • /
    • 2002
  • 은이 피복된 Bi(2223) 단심 초전도 선재에 절연층으로 $SrZrO_3$ 피막을 졸-겔과 딥-코팅법으로 제조하여 $SrZrO_3$ 코팅층과 초전도 선재간 접착력 특성을 조사하였다. 실험인자로는 출발원료의 몰비, 유기화합물 첨가량, 건조온도 및 시간, 열처리 온도 및 시간이었으며 다구찌법의 망대특성과 $L_18(2^1{\times}3^7)$ 직교배열표를 이용하여 코팅층의 최적조건인 인자와 수준 조합의 최적화를 접착강도를 측정하여 분석하였다. 최적의 접착 특성을 가진 코팅조건은 Sr/Zr의 몰비가 0.3/0.7, 유기화합물 첨가량이 5wt%, 건조온도 및 시간은 160${\circ}C$ 10분, 열처리 온도 및 시간은 500${\circ}C$ 20분이었다. 분산분석 결과, 유의수준이 ${\alpha}$=0.1인 통계적으로 90% 신뢰공정이었다.

Incorporation of silver nanoparticles on the surface of orthodontic microimplants to achieve antimicrobial properties

  • Venugopal, Adith;Muthuchamy, Nallal;Tejani, Harsh;Anantha-Iyengar-Gopalan, Anantha-Iyengar-Gopalan;Lee, Kwang-Pill;Lee, Heon-Jin;Kyung, Hee Moon
    • 대한치과교정학회지
    • /
    • 제47권1호
    • /
    • pp.3-10
    • /
    • 2017
  • Objective: Microbial aggregation around dental implants can lead to loss/loosening of the implants. This study was aimed at surface treating titanium microimplants with silver nanoparticles (AgNPs) to achieve antibacterial properties. Methods: AgNP-modified titanium microimplants (Ti-nAg) were prepared using two methods. The first method involved coating the microimplants with regular AgNPs (Ti-AgNP) and the second involved coating them with a AgNP-coated biopolymer (Ti-BP-AgNP). The topologies, microstructures, and chemical compositions of the surfaces of the Ti-nAg were characterized by scanning electron microscopy (SEM) equipped with energy-dispersive spectrometer (EDS) and X-ray photoelectron spectroscopy (XPS). Disk diffusion tests using Streptococcus mutans, Streptococcus sanguinis, and Aggregatibacter actinomycetemcomitans were performed to test the antibacterial activity of the Ti-nAg microimplants. Results: SEM revealed that only a meager amount of AgNPs was sparsely deposited on the Ti-AgNP surface with the first method, while a layer of AgNP-coated biopolymer extended along the Ti-BP-AgNP surface in the second method. The diameters of the coated nanoparticles were in the range of 10 to 30 nm. EDS revealed 1.05 atomic % of Ag on the surface of the Ti-AgNP and an astounding 21.2 atomic % on the surface of the Ti-BP-AgNP. XPS confirmed the metallic state of silver on the Ti-BP-AgNP surface. After 24 hours of incubation, clear zones of inhibition were seen around the Ti-BP-AgNP microimplants in all three test bacterial culture plates, whereas no antibacterial effect was observed with the Ti-AgNP microimplants. Conclusions: Titanium microimplants modified with Ti-BP-AgNP exhibit excellent antibacterial properties, making them a promising implantable biomaterial.

Determination of Hg22+ Ions Using a Modified Glassy Carbon Electrode with 2,2':6':2''-Terpyridine

  • Kong, Young-Tae;Bae, Yun-Jung;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권2호
    • /
    • pp.346-350
    • /
    • 2002
  • A glassy carbon electrode (GCE) modified with 2,2':6':2”-terpyridine (2,2':6':2”-TPR) using a spin coating method was applied for the highly selective and sensitive analysis of a trace amount of $Hg_2^{2+}$ ions. Various experimental parameters, which influenced the response of the 2,2':6':2”-TPR modified electrode to $Hg_2^{2+}$ ions, were optimized. The linear sweep and differential pulse voltammograms for the 2,2':6':2”-TPR modified electrode deposited with Hg show a well-defined anodic peak at +0.65 V (vs. Ag|AgCl). After a 25 min preconcentration time in an $Hg_2^{2+}$ ion solution (0.1 M acetate buffer, pH 5.0), differential pulse voltammetry(DPV) with 2,2':6':2”-TPR modified electrode shows a linear response between $1.0\;{\times}\;10^{-6}M\;and\;2.0\;{\times}\;10^{-7}M$. The least-square treatment of these data produce an equation of I[${\mu}A$] = 0.031 + 0.005C with r = 0.980(n = 5). The detection limit of this electrode with linear sweep voltammetry and differential pulse anodic voltammetry were $2.0\;{\times}\;10^{-6}M\;and\;8.0\;{\times}\;10^{-8}M$, respectively. The presence of Pb, Fe, Cd, Ti, Ni, Co, Mg, Al, Mn, and Zn did not interfere in the analysis of the $Hg_2^{2+}$ ion. The 2,2':6':2”-TPR modified GCE has been successfully applied in determination trace amounts of Hg in a human urine sample.

Bis-GMA 유도체로부터 제조된 고분자 코팅에 의한 리튬이차전지용 폴리에틸렌 격리막의 고온 안정성 향상 (Improvement of Thermal Stability of Polyethylene Lithium-ion Battery Separator via Coating with Polymers Synthesized from Bis-GMA Derivatives)

  • 임현구;홍지혜;김창근
    • 폴리머
    • /
    • 제34권6호
    • /
    • pp.517-521
    • /
    • 2010
  • 리튬이온 이차전지에는 폴리에틸렌 격리막이 주로 사용되어 오고 있다. 전지의 고온 안정성 확보를 위해서는 폴리에틸렌 격리막보다 높은 멜트다운(melt down) 온도를 갖는 격리막이 요구된다. 이를 위해 폴리에틸렌 격리막을 단량체인 2,2-bis[4-(2-hydroxy-3-methacryloyloxypropoxy)phenyl]propane(bis-GMA) 혹은 이의 유도체들로 코팅하고 이를 라디칼 중합반응시켰다. 점도가 높은 bis-GMA를 사용한 경우에는 라디칼 중합반응이 진행되지 않은 반면 점도가 낮은 bis-GMA 유도체를 사용한 경우에는 라디칼 중합반응이 진행되었다. 적절한 함량의 bis-GMA 유도체를 포함한 반응액으로 격리막을 코팅하고 이를 중합반응시켜 격리막을 제조한 결과, 격리막의 통기도 감소없이 멜트다운 온도를 $160^{\circ}C$까지 향상시킬 수 있었다.

멜라토닌이 함유된 다층 코팅 펠렛의 방출 및 특성분석 (Release and Characterization of Multiple Coated Pellets Containing Melatonin)

  • 강복기;강길선;김종민;정상영;이해방;조선행
    • Journal of Pharmaceutical Investigation
    • /
    • 제33권3호
    • /
    • pp.179-185
    • /
    • 2003
  • Melatonin (MT) is an indole amide pineal hormone. It has not only very short half-life but also pH-sensitive property. The sustained release dosage form which delivers MT in a circadian fashion over 8 h is clinical value. The purpose of this study is to prepare sugar beads using multiple coating methods and enteric-coated in a sustained release to evaluate in vitro release characteristics in simulated gastric and intestinal fluids. The $Eudragit^{\circledR}$ as a polymer, sustained release membrane, and triethylcitrate (TEC) as a plasticzer were used. Multi-coated melatonin delivery system was composed of sugar, various excipients, $Eudragit^{\circledR}$ and enteric materials (e.g. hydroxy propyl methyl cellulose phthalate, HPMCP), and prepared by fluid bed coater. The dissolution test was carried out using the basket method at a stirring speed of 100 rpm at $37^{\circ}C$ in simulated gastric (pH 1.2) and intestinal fluid (pH 7.4). The released amount of MT was determined by High performance liquid chromatography method. The morhologies of surface and cross section of multi-coated beads were observed by scanning electron microscope. Size of multi-coated sugar beads was ranged over $1000{\sim}1300\;{\mu}m$. The release rate of MT from coated beads was limited in simulated gastric fluid (pH 1.2), but it was sustained in intestinal fluid (pH 7.4) during $3{\sim}8$ hours. The MT beads may provide small-intestine-targeted device for oral delivery. Studies on animal and relative experiment are in process.