• Title/Summary/Keyword: coagulant(alum)

Search Result 85, Processing Time 0.02 seconds

Removal of Microalgae Using Inorganic Coagulants in Coagulation and Sedimentation Processes for Water Treatment (응집.침전공정에서 무기고분자응집제를 이용한 미세조류의 제거)

  • Cheong, Cheong-Jo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • The purpose of this study is to understand the removal possibility of microalgae using inorganic coagulants in coagulation and sedimentation process for water treatment. Removal of microalgae was studied according to coagulant type(Alum and PAC), coagulation factors(alkalinity, coagulant dosage, and setting time), and size fraction of microalgae. The contribution of applied coagulants for removal of microalgae was also examined. The removal rate of the microalgae by change of alkalinity was most high in 25 mg/L of alkalinity(Alum) as 87.2% and 30 mg/L of that(PAC) as 90.1%. Optimal coagulant dosage to remove the microalgae was 40 mg/L(removal effi.; 88.1%), and PAC was 50 mg/L(removal effi.; 90.1%). Alum was better than the PAC to remove the microlgae. In the water treatment processes such as rapid slow mixing and sedimentation the removal efficiency of microalgae with coagulants was 2 times higher than that of without. In optimal condition, the removal efficiencies of microalgae were nanoplankton > microplankton > picoplankton. Especially, the removal efficiency of the picoplankton was very low as below 30%.

Minimizing of Residual Aluminum in Water Treatment Process (정수처리공정에서 잔류 알루미늄 최소화 방안)

  • 이미영;조덕희;박종현
    • Proceedings of the Korean Sanitation Conference
    • /
    • 2004.11a
    • /
    • pp.54-65
    • /
    • 2004
  • Use of aluminum salts as coagulants In water treatment may lead to increased concentrations of aluminum in finished water. Aluminum is a suspected causative agent of neurological disorders such as Alzheimer's disease. The objective of this study was to examine variation and minimizing in residual aluminum concentration during water treatment process. The aluminum sources at Bokjeong Water Plant were present naturally aluminum in the raw water and derived due to use of PACS as a coagulant. Much of the raw water total aluminum were in particulate and suspended aluminum. In this study was compared the optimize condition to minimize the concentration of residual aluminum using Jar-test with the various coagulants such as alum, PAC, PACS. The results indicated that PACS was more effective than alum, PAC and insufficient or excessive alum, PAC, PACS addition led to increase residual aluminum. Adjustment raw water pH $6.5\~7.0$ before coagulation using PACS was capable of minimizing total and dissolved aluminum. Thus it is important that the optimal dosage of coagulant and the optimal pH adjustment before coagulation can decided to minimize the concentration of residual aluminum in treated water.

  • PDF

The Estimation of the Coagulant on Method of Lime Input in the Water Treatment Plant at High Turbidity (고탁도시 소석회 투입방법에 따른 정수장 응집제의 효율 평가)

  • Bang, Mi Ran;Lim, Bong Su;Bae, Byung Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.107-117
    • /
    • 1998
  • In order to removal turbidity at high turbidity, this study was carried to evaluate the coagulants(Alum, PACl, PACS) that was suited the characteristics of raw water in water treatment plants and to determinate the optimum method of lime feed. When the optimum coagulant was selected the organic matter removal was also investigated as $UV_{254}$. PACl, lime first feed had the highest turbidity removal efficiency rate as above 99.1% and then $UV_{254}$ removal rate was obtained over than 88.0%. If you had the necessary of the lime feed, among the method of lime feed time interval feed largely was improved than simultaneous feed. Also, lime feed dose had about 1/5 of coagulants dose in case of Alum and PACl, but always PACS should be considerated lime dose.

  • PDF

The development of algae removal system to minimize the damage of algae bloom on freshwater (담수조류의 대량번식에 따른 피해를 최소화하기 위한 녹조제거기 개발)

  • Han J.H.;Park W.S.;Kim J.H.;Lee Y.S.;Rho J.H.;Kim Y.K.;Yoon B.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.1
    • /
    • pp.62-69
    • /
    • 2000
  • The study was performed to apply the algae removal system to coagulation-filtration process for minimize the damage to screen interruption of water treatment plants and died of fish by algae bloom on freshwater. Sample used Nokdong river water and Alkalinity, turbidity, chlorophyll-a and pH measured using Jar test and drum filter for coagulation-filtration process to determine optimum coagulation condition. A jar test apparatus and laboratory reactor were used in this study. The highest removal efficiency was observed when condition of flocculation time, coagulant dosage, drum filter rpm and chlorophyll-a concentration were to be 5min, 5mg/ℓ, 3rpm and 90㎍/ℓ, respectively. The average removal efficiencies measured of chlorophyll-a and turbidity using Alum were 50~60% and 30~50%, respectively. PAC was more effective than Alum in removal chlorophyll-a about 20%.

  • PDF

Removal efficiency of various coagulants for Microcystis, Anabaena and Oscillatoria at different cell densities

  • Han, Joo Eun;Park, Soo Hyung;Yaqub, Muhammad;Yun, Sang Leen;Kim, Seog-ku;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2022
  • The continuous industrial growth increases the volume of pollutants discharged into the water, which induces Cyanobacteria in the receiving bodies. The removal of various cyanobacteria such as Microcystis, Anabaena, and Oscillatoria was explored to analyze their removal characteristics using different chemical and mineral coagulants. The chemical coagulants, including poly aluminium chloride (PACl), Alum, and mineral coagulants such as Loess and Illite, were tested to remove selected cyanobacteria. Results indicated that the removal rate increased with coagulant dosage regardless of the type of coagulant. The removal of selected cyanobacteria using chemical coagulant was found in the order: Microcystis > Anabaena > Oscillatoria. The PACl coagulant showed the most efficient removal rate for Microcystis, Anabaena, Oscillatoria. Removal rate of Microcystis conducted by PACl showed 92% at 100,000 cells/mL and 98.4% at 1,000,000 cells/mL whereas Illite showed lower 70% and Loess showed lower 50% in both 100,000 cells/mL and 1,000,000 cells/mL. The removal rate of Anabaena and Oscillatoria by PACl and Alum was higher 80%, while the other coagulants exhibited lower than 75% at 1,000,000 cells/mL. The removal rate of Oscillatoria by PACl was 80.1%, while the other coagulants exhibited lower than 70% at 1,000,000 cells/mL. Moreover, the mineral coagulants showed better removal efficiency at a higher concentration than low concentration during experiments. Therefore, removing cyanobacteria from water streams can be improved through coagulation by selecting a specific coagulant for a particular type of algae.

Ecotoxicological effects of Alum and Ferric chloride on the population of Eisenia fetida (Annelida : Oligochaeta) (Alum과 Ferric chloride가 줄지렁이 개체군에 미치는 생태독성학적 영향)

  • Park, Kwang-Il;Bae, Yoon-Hwan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.1
    • /
    • pp.50-60
    • /
    • 2012
  • This study was carried out to evaluate the ecotoxicological effects of Alum and Ferric chloride on the population of Eisenia fetida in vermicomposting of sewage sludge. Using contact filter toxicity test, it was shown that LC50 of Alum and Ferric chloride on adult Eisenia fetida were 457.4 mg $kg^{-1}$ and 1,665.2 mg $kg^{-1}$, respectively,which meant Ferric chloride had much higher acute toxicity on earthworm than Alum. Alum didn't affect on cocoon production, hatchability and number of hatched larvae of Eisenia fetida. Ferric chloride didn't have any efects on number of hatched larvae per cocoon, but reduced cocoon production and hatchability. Larval density of next generation was reduced by the food containing Alum and Ferric chloride. Above results indicated that the Alum and Ferric chloride could be one of the hazardous materials that made extinction of earthworm population when the sewage sludge treated with Alum and Ferric chloride was supplied to the earthworms.

Optimal coagulant and its dosage for turbidity and total organic dissolved carbon removal (탁도와 총유기탄소 제거를 위한 최적응집제 및 투여량 선정 연구)

  • Park, Hanbai;Woo, Dal-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2321-2327
    • /
    • 2015
  • Three coagulants, alum sulfate(alum), poly aluminum chloride(PAC) and poly aluminum silicate chloride (PASC), were used to remove low to high turbidity and TOC in surface and ground blended water. Laboratory experiments and pilot plant experiments were carried out to evaluate the optimal coagulant and its dosage. To determine the optimized coagulant and its dosage, the turbidity, TOC and pH were measured. The experimental results showed the best removal performance using PASC. The optimal dosage of PASC between 3-20 NTU was found to be 15 mg/L in the jar test. In the pilot test, a 15 mg/L PASC dosage was applied and resulted in the efficient removal of turbidity and TOC between 3.6-27 NTU. The removal efficiency of PASC increased with increasing turbidity and TOC.

Characteristics of Micro Floc in a Rapid Mixing Step at Different Coagulant Dose (급속혼화공정에서 응집제 주입률에 따른 미세입자의 성장특성)

  • Jun, Hang-Bae;Park, Sang-Min;Park, Noh-Back;Jung, Kyung-Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.243-252
    • /
    • 2007
  • Effects of alum dosage on the particle growth were investigated by monitoring particle counts in a rapid mixing process. Kaolin was used for turbid water sample and several other chemicals were added to adjust pH and ionic strength. The range of velocity gradient and mixing time applied for rapid mixing were $200{\sim}300sec^{-1}$ and 30~180 sec, respectively. Particle distribution in the synthetic water sample was close to the natural water where their turbidity was same. The number of particles in the range of $10.0{\sim}12.0{\mu}m$ increased rapidly with rapid mixing time at alum dose of 20mg/L, however, the number of $8.0{\sim}9.0{\mu}m$ particles increased at alum dose of 50mg/L. The number of $14.0{\sim}25.0{\mu}m$ particles at alum dose of 20mg/L was 10 times higher than them at alum dose of 50mg/L. Dominant particle growth was monitored at the lower alum dose than the optimum dose from a jar test at an extended rapid mixing time(about 120 sec). The number of $8.0{\sim}14.0{\mu}m$ particles was lower both at a higher alum doses and higher G values. At G value of $200sec^{-1}$ and at alum dose of 10-20mg/L, residual turbidity was lower as the mixing time increased. But at alum dose above 40mg/L and at same G value, lower residual turbidity occurred in a short rapid mixing time. Low residual turbidity at G value of $300sec^{-1}$ occurred both at lower alum doses and at shorter mixing time comparing to the results at G value of $200sec^{-1}$.

T-P Removal Efficiency According to Coagulant Dosage and Operating Cost Analysis (응집제 투입에 따른 인 제거 효율 및 운영비용 분석)

  • Yun, Soyoung;Ryu, Jaena;Oh, Jeill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.549-556
    • /
    • 2012
  • T-P removal efficiency was analyzed according to the metal to initial T-P ratio (mole basis) with respect to the samples from different WWTPs having various initial T-P and SS conditions. Also, operating costs were calculated based on the injected coagulant amount and the amount of sludge production. Most experiments were conducted by the standard jar-test protocol. Molar ratio of coagulant dose was varied considerably according to the initial SS concentration range in secondary clarifier effluent samples which had above 0.5 mg/L of initial T-P. Based on 90% T-P removal efficiency, results were: At the initial SS range of below 10 mg/L, Alum (8%) = 11 mol Al/mol P needed and PAC (17%) = 9.6 mol Al/mol P needed; At the initial SS range of above 10 mg/L, Alum (8%) = 3.9 mol Al/mol P needed and PAC (17%) = 3.2 mol Al/mol P needed.

Coagulation-membrane separation hybrid treatment of secondary treated effluent for high efficiency phosphorus removal (하수 2차처리 방류수의 총인 고효율 처리를 위한 응집·막분리 혼성처리)

  • Choi, Wookjin;Lee, Byungha;Park, Joonhong;Cha, Hoyoung;Lee, Byungchan;Song, Kyungguen
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.47-53
    • /
    • 2018
  • This study investigated phosphorus removal from secondary treated effluent using coagulation-membrane separation hybrid treatment to satisfy strict regulation in wastewater treatment. The membrane separation process was used to remove suspended phosphorus particles after coagulation/settlement. Membrane separation with $0.2{\mu}m$ pore size of micro filtration membrane could reduce phosphorus concentration to 0.02 mg P/L after coagulation with 1 mg Al/L dose of polyaluminum chloride (PACl). Regardless of coagulant, the residual concentration of phosphorus decreased as the dose increased from 1.5 to 3.5 mg Al/L, while the target concentration of 0.05 mg P/L or less was achieved at 2.5 mg Al/L for the aluminum sulfate (Alum) and 3.5 mg Al/L for PACl. Moreover, alum showed better membrane flux as make bigger particles than PACl. Alum showed a 40% of flux decrease at 2.5 mg Al/L dose, while PACl indicated a 50% decrease of membrane flux even with a higher dose of 3.5 mg Al/L. Thus, alum was more effective coagulant than PACl considering phosphorus removal and membrane flux as well as its dose. Consequently, the coagulation-membrane separation hybrid treatment could be mitigate regulation on phosphorus removal as unsettleable phosphorus particles were effectively removed by membrane after coagulation.