• Title/Summary/Keyword: co-gradient protein elution

Search Result 2, Processing Time 0.017 seconds

Biochemical Characteristics of a Palmitoyl Acyl Carrier Protein Thioesterase Purified from Iris pseudoacorus

  • Kang, Han-Chul;Hwang, Young-Soo
    • BMB Reports
    • /
    • v.29 no.5
    • /
    • pp.436-441
    • /
    • 1996
  • The palmitoyl acyl carrier protein (ACP) specific thioesterase (EC 3.1.2.14) from Iris pseudoacorus was purified and characterized. The thioesterase which was very unstable in relatively high salt concentrations was eluted using a co-gradient of Triton X-100 and low concentration of KCl or Na-phosphate from Q-Sepharose, DEAE-Sepharose, and hydroxyapatite chromatography. SDS-PAGE analysis showed a single band with a molecular weight of 35,000. The native molecular weight of approximately 37,000 was estimated by Sephacryl S-200 chromatography, indicating that the enzyme is a monomer. The thioesterase activity was inhibited about 75% and 50% by N-ethylmaleimide (2 mM) and phenylmethylsulfonyl fluoride (2 mM). respectively. The N-ethylmaleimide-inactivation was protected by sodium palmitate but the inactivation with phenylmethylsulfonyl fluoride was not protected. Oxidation of thiols by 2 mM 5.5'-dithio-bis-(2-nitrobenzoic acid) resulted in 65% inactivation of the enzyme. These results suggest that a cysteinyl residue is essential to the catalytic reaction of the enzyme. The enzyme activity was increased by sodium citrate and also by $Cu^{2+}$

  • PDF

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.