• Title/Summary/Keyword: closed

Search Result 10,307, Processing Time 0.032 seconds

Can finite element and closed-form solutions for laterally loaded piles be identical?

  • Sawant, Vishwas A.;Shukla, Sanjay Kumar
    • Structural Engineering and Mechanics
    • /
    • v.43 no.2
    • /
    • pp.239-251
    • /
    • 2012
  • The analysis of laterally loaded piles is generally carried out by idealizing the soil mass as Winkler springs, which is a crude approximation; however this approach gives reasonable results for many practical applications. For more precise analysis, the three- dimensional finite element analysis (FEA) is one of the best alternatives. The FEA uses the modulus of elasticity $E_s$ of soil, which can be determined in the laboratory by conducting suitable laboratory tests on undisturbed soil samples. Because of the different concepts and idealizations in these two approaches, the results are expected to vary significantly. In order to investigate this fact in detail, three-dimensional finite element analyses were carried out using different combinations of soil and pile characteristics. The FE results related to the pile deflections are compared with the closed-form solutions in which the modulus of subgrade reaction $k_s$ is evaluated using the well-known $k_s-E_s$ relationship. In view of the observed discrepancy between the FE results and the closed-form solutions, an improved relationship between the modulus of subgrade reaction and the elastic constants is proposed, so that the solutions from the closed-form equations and the FEA can be closer to each other.

A Study on the Performance of Heat Exchanger for Closed Cooling Tower (밀폐식 냉각탑용 열교환기의 성능에 관한 연구)

  • Lee, Sang-Sik;Yoo, Seong-Yeon;Kim, Jin-Hyuck;Ahn, Young-Hwan;Park, Hyoung-Joon;Ryu, Hae-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.334-339
    • /
    • 2008
  • An closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The purpose of this study is to evaluate thermal performance of heat exchanger at various conditions and to provide design datebase. The experimental study regarding heat exchanger for closed cooling tower was conducted. Experimental apparatus consists of constant temperature bath, water pump, spray nozzle, heat exchanger, fan, and date acquisition system. Heat transfer rates at various air velocitys, water flow rates, two different spray modes were measured and heat transfer coefficient were calculated to compare the thermal performances. This study provides that the heat transfer coefficient increases with increasing spray water flow rate and with increasing air velocity. The wet mode was more effective than dry mode for closed cooling tower to this study.

  • PDF

A Study on the Heat Transport Limitations of a PFC(FC-72) Two-Phase Closed Thermosyphon for Cooling Power Semiconductors (전력변환 반도체 냉각용 PFC(FC-72) 밀폐형 2상 열사이폰의 열전달 한계에 관한 연구)

  • 박용주;홍성은;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.725-733
    • /
    • 2002
  • In this study, the heat transport limitations of a two-phase closed thermosyphon were investigated. For the test, a two-phase closed thermosyphon ($L_t/: 600 mm,\;L_e:105mm,\;L_a:75mm,\;L_c:420mm,\;D_o:22.2mm,$ container: copper (inner grooved surface), working fluid: PFC ($C_6F_14$) was fabricated with a reservoir that can change the fill charge ratio. The following was imposed as the factors on the heat transport limitations of a two-phase closed thermosyphon. 1) Fill charge ratio of the working fluid. 2) Tilt angle of the longitudinal axis. From tile experimental data, some results were obtained as follows. When the fill charge ratio was relatively small ($\psi$20%), the heat transport limitation occurred about 100W by dry-out limitation. However over 40%, it shelved nearly constant value (500 W) by flooding limitation. The heat transport limitation according to the tilt angle increased smoothly until the tilt angle was $60^{\circ}$,/TEX>, after then decreased slowly.

Activation of Vastus Medialis and Biceps Femoris Muscle in Open and Closed Kinetic Chain Exercise (열린사슬 운동과 닫힌사슬운동시 내측광근과 대퇴이두근의 근활성도 차이)

  • Seok, Chang-Yeob;Lee, Chang-Ryeol;Lee, Moon-Hwan
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.12 no.3
    • /
    • pp.115-128
    • /
    • 2008
  • Purpose : This study was performed to distinguish the muscle activation of vastus medialis and biceps femoris through open and closed kinetic chain exercise. Methods : 31 healthy male and female students in Daegu Health College were participated in this study. All subjects were conducted three types open and closed kinetic chain exercises to examine muscle activity during the last four seconds using the sEMG system. Collected EMG data were normalized using the maximal voluntary isometric contraction(MVIC). Results : MVIC of each muscle was showed significantly increased(p<0.5). In the case of open chain exercise, the type 3 exercise most increased than type 2 and 3 exercise in vastus medialis than biceps femoris muscle. The closed chain exercise presented type 6 exercise most increased than type 4 and 5 exercise in biceps femoris than vastus medialis. Conclusion : This study finally proved that muscle activity which maintains stability of knee differ from depending on the types of exercises. Therefore, the combination of the two chain exercises is believed to greatly contribute to increments in muscle activity.

  • PDF

Enumeration of axial rotation

  • Yoon, Yong-San
    • Advances in biomechanics and applications
    • /
    • v.1 no.2
    • /
    • pp.85-93
    • /
    • 2014
  • In this paper, two procedures of enumerating the axial rotation are proposed using the unit sphere of the spherical rotation coordinate system specifying 3D rotation. If the trajectory of the movement is known, the integration of the axial component of the angular velocity plus the geometric effect equal to the enclosed area subtended by the geodesic path on the surface of the unit sphere. If the postures of the initial and final positions are known, the axial rotation is determined by the angular difference from the parallel transport along the geodesic path. The path dependency of the axial rotation of the three dimensional rigid body motion is due to the geometric effect corresponding to the closed loop discontinuity. Firstly, the closed loop discontinuity is examined for the infinitesimal region. The general closed loop discontinuity can be evaluated by the summation of those discontinuities of the infinitesimal regions forming the whole loop. This general loop discontinuity is equal to the surface area enclosed by the closed loop on the surface of the unit sphere. Using this quantification of the closed loop discontinuity of the axial rotation, the geometric effect is determined in enumerating the axial rotation. As an example, the axial rotation of the arm by the Codman's movement is evaluated, which other methods of enumerating the axial rotations failed.

A Vision-Based Method to Find Fingertips in a Closed Hand

  • Chaudhary, Ankit;Vatwani, Kapil;Agrawal, Tushar;Raheja, J.L.
    • Journal of Information Processing Systems
    • /
    • v.8 no.3
    • /
    • pp.399-408
    • /
    • 2012
  • Hand gesture recognition is an important area of research in the field of Human Computer Interaction (HCI). The geometric attributes of the hand play an important role in hand shape reconstruction and gesture recognition. That said, fingertips are one of the important attributes for the detection of hand gestures and can provide valuable information from hand images. Many methods are available in scientific literature for fingertips detection with an open hand but very poor results are available for fingertips detection when the hand is closed. This paper presents a new method for the detection of fingertips in a closed hand using the corner detection method and an advanced edge detection algorithm. It is important to note that the skin color segmentation methodology did not work for fingertips detection in a closed hand. Thus the proposed method applied Gabor filter techniques for the detection of edges and then applied the corner detection algorithm for the detection of fingertips through the edges. To check the accuracy of the method, this method was tested on a vast number of images taken with a webcam. The method resulted in a higher accuracy rate of detections from the images. The method was further implemented on video for testing its validity on real time image capturing. These closed hand fingertips detection would help in controlling an electro-mechanical robotic hand via hand gesture in a natural way.

Novel Control Method for a Hybrid Active Power Filter with Injection Circuit Using a Hybrid Fuzzy Controller

  • Chau, MinhThuyen;Luo, An;Shuai, Zhikang;Ma, Fujun;Xie, Ning;Chau, VanBao
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.800-812
    • /
    • 2012
  • This paper analyses the mathematical model and control strategies of a Hybrid Active Power Filter with Injection Circuit (IHAPF). The control strategy based on the load harmonic current detection is selected. A novel control method for a IHAPF, which is based on the analyzed control mathematical model, is proposed. It consists of two closed-control loops. The upper closed-control loop consists of a single fuzzy logic controller and the IHAPF model, while the lower closed-control loop is composed of an Adaptive Network based Fuzzy Inference System (ANFIS) controller, a Neural Generalized Predictive (NGP) regulator and the IHAPF model. The purpose of the lower closed-control loop is to improve the performance of the upper closed-control loop. When compared to other control methods, the simulation and experimental results show that the proposed control method has the advantages of a shorter response time, good online control and very effective harmonics reduction.

Thermal Reliability Analysis of BLDC Motor in a High Speed Axial Fan by the Accelerated Life Test (가속수명시험에 의한 고속팬용 밀폐구조형 BLDC 모터의 열신뢰성 분석)

  • Lee Tae-Gu;Moon Jong-Sun;Yoo Hoseon;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1169-1176
    • /
    • 2005
  • In this paper, thermal reliability of a closed type BLDC (Brushless DC) motor for high speed axial fan was analyzed by the accelerated life test. The closed type BLDC (Model No. MB1-8855-J01) motor was controlled by PCB module, which was composed of various electrical components. The failure of the closed type BLDC motor happened in PCB module due to high temperature. Failure mechanism of the closed type BLDC motor appears to be electrolyte dry out of capacitor. The accelerate life test was performed in temperature stress of $85^{\circ}C\;and\;105^{\circ}C$, respectively The failure data from the accelerated life test were analyzed and the life in each stress level was estimated with 960h and 261 h. At last, both life expression according to operating temperature of PCB module and life of the closed type BLBC motor in normal condition $(50^{\circ}C)$ were suggested.

The Effect of PNF Arm Flexion Pattern on the Muscle Activation of Lower Extremity by Kinematic Chain Positions (사슬운동 자세에 따른 고유수용성신경근촉진법 팔 패턴이 다리의 근활성도에 미치는 효과)

  • Kim, Hee-Gwon;Seo, Yeon-Soon
    • PNF and Movement
    • /
    • v.13 no.2
    • /
    • pp.95-102
    • /
    • 2015
  • Purpose: The purpose of this study was to analyze the effect of arm flexion patterns of proprioceptive neuromuscular facilitation on muscle activation in the contralateral lower extremity. Open kinematic chain and closed kinematic chain positions were used. Methods: This study used an electromyogram (MP150, Biopac Systems, USA) to measure muscle activation in 20 healthy male students. Comparative analysis was completed on muscle activation of the vastus lateralis, biceps femoris, tibialis anterior, and gastrocnemius of the contralateral lower extremity. Open kinematic chain and closed kinematic chain positions were used with a unilateral arm flexion-abduction-external rotation pattern. Paired t-tests using the SPSS 12.0 for Windows analyzed the data produced by the electromyogram. Results: There was a statistically significant difference in muscle activation in the biceps femoris, gastrocnemius, and tibialis anterior when the open kinematic chain and closed kinematic chain positions were compared (p < 0.05). Conclusion: The biceps femoris, gastrocnemius, and tibialis anterior muscles showed greater muscle activation in the closed kinematic chain position when compared to the open kinematic chain position.

Effects of Visual Feedback Closed Kinetic Chain Exercise on the Lower Limb Muscles Activity and ankle Instability in Adult men with Chronic Ankle Instability (시각적 피드백을 이용한 닫힌 사슬 운동이 만성 발목 불안정성 성인남성의 하지 근활성도 및 발목 불안정성 지수에 미치는 영향)

  • Nam, Seung-Min;Lee, Do-Youn
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.1
    • /
    • pp.131-138
    • /
    • 2019
  • PURPOSE: This study examined the effects on muscle activation and ankle instability following sudden ankle inversion of the closed kinetic chain exercise using visual feedback to evaluate chronic ankle instability in adult males. METHODS: In this study, 28 subjects with chronic ankle instability were recruited and randomly divided into a closed kinetic chain exercise using a visual feedback group(n=13) and an open kinetic chain exercise group(n=15). Each group underwent 30 minutes of exercise three times a week for 8 weeks. The electromyographic(EMG) values of the rectus femoris, biceps femoris, tibialis anterior, peroneus longus, peroneus brevis, and lateral gastrocnemius muscles were measured to analyze muscle activity. The Cumberland ankle instability tool(CAIT) was used to measure ankle instability. RESULTS: Both groups showed improvements in tibialis anterior, peroneus longus and CAIT score(p<.05). In the experimental group, there were significant improvements in the rectus femoris, biceps femoris, and lateral gastrocnemius muscle activation(p<.05). CONCLUSION: The results suggest that closed kinetic chain exercise using visual feedback can be a useful treatment method for patients with chronic ankle instability.