• Title/Summary/Keyword: clinical stage

Search Result 2,594, Processing Time 0.034 seconds

Acromial Morphology in Different MR Oblique Sagittal Slices: Correlation with Rotator Cuff Disorder (자기 공명 영상의 사 시상면에서의 견봉 형태의 변화: 회전근 개 질환과의 임상적 연관성 분석)

  • Jo, Chris H.;Kim, Ji-Beom;Choi, Hye-Yeon;Ko, Young-Whan;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baik;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.173-179
    • /
    • 2009
  • Purpose: On the hypothesis that the acromion morphology is changed according to the its site, we identified the morphology of the acromion on the oblique slices of MRI and we investigated the association of the acromial shape with the clinical stages of rotator cuff disorder on the magnetic resonance (MR) images. In addition, we compared the acromion morphology on MRI and simple X-rays. Material and Methods: The MR images of seventy one patients with rotator cuff disorder and who underwent arthroscopic surgery were compared with that of a control group of sixteen patients who didn't have rotator cuff disorder on MRI. On three subsequent oblique sagittal slices from the lateral edge of the acromion (S1, S2 and S3), each acromion morphology on the MRI slices was classified according to Epstein et al: flat, curved or hooked. We investigated the changing parttern of the acromion shape and we compared the acromion shape on MRI and that on simple X-rays. We classified the rotator cuff tear by the severity: bursitis, partial thickness tear or full thickness tear. We investigated which acromial type on the MRI oblique slice was associated with the severity of rotator cuff disease. Results: Changes of the acromial shape occurred in 54 patients (76.1%). The most frequent pattern was that the types are same on S1 and S2 and different on S3 (22 cases, 31.0%). The acromial type on S1 and S2 was significantly associated with the severity of rotator cuff disorder (p=0.001 and 0.022), respectively. There was no reliability of the acromial shape on MRI and roentgenography (p>0.05) Conclusion: The type of acromion changed from lateral to medial. Among the three positions, the shape of the acromion on S1 and S2 had meaningful correlation with the clinical stage of rotator cuff disorder. There was no statistical correlation of the acromial shape between MRI and simple X-ray.

Is the Renal Uptake of $^{99m}Tc$-DMSA Decreased in Microalbuminuric Diabetic Patient? (미세 단백뇨기의 당뇨병 환자에서 $^{99m}Tc$-DMSA 신섭취율은 감소하는가?)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.398-404
    • /
    • 1999
  • Purpose: Diabetic nephropathy is the most common cause of end stage renal disease and the incidence is progressively increasing. The aim of this study was to investigate the differences of $^{99m}Tc$-DMSA renal uptake among diabetic patients with normoalbuminuria, microalbuminuria and overt proteinuria, and then to determine the clinical usefulness of $^{99m}Tc$-DMSA in predicting early diabetic nephropathy Materials and Methods: $^{99m}Tc$-DMSA scan was performed and a total renal uptake of $^{99m}Tc$-DMSA was measured in 145 diabetic patients. Patients were divided into 3 groups according to the amount of 24 hour urinary albumin excretion as Group I (normoalbuminuria, 74 cases), Group II (microalbuminuria, 39 cases), and Group III (overt proteinuria, 32 cases). The differences of $^{99m}Tc$-DMSA renal uptake among the 3 groups and the correlation between the renal uptake of $^{99m}Tc$-DMSA and other clinical parameters were analyzed. Results: The total renal uptake of $^{99m}Tc$-DMSA of Group II ($40.8{\pm}11.0%$) was significantly lower than that of Group I ($54.4{\pm}6.3%$, p<0.001). The uptake of Group III ($27.7{\pm}12.0%$) was significantly lower than those of both Group I and Group II (p<0.001). $^{99m}Tc$-DMSA total renal uptakes correlated negatively with serum creatinine level (r=-0.629, p<0.001) and positively correlated with creatinine clearance rate (r=0.102, p<0.001). Conclusion: $^{99m}Tc$-DMSA total renal uptake of diabetic patients with microalbuminuria was significantly decreased compared with that of patients of normoalbuminuria. Therefore, $^{99m}Tc$-DMSA scan can be used as a diagnostic study for early detection of the diabetic nephropathy.

  • PDF

Association of diet-related quality of life with dietary regimen practice, health-related quality of life, and gastrointestinal symptoms in end-stage renal disease patients with hemodialysis (혈액투석을 실행중인 말기 신부전 환자의 식사관련 삶의 질(Diet-Related Quality of Life)과 식사요법 실천도, 건강관련 삶의 질 및 위장관 증상과의 관련성 연구)

  • Lee, JinJu;Kim, Ji-Myung;Kim, Yuri
    • Journal of Nutrition and Health
    • /
    • v.46 no.2
    • /
    • pp.137-146
    • /
    • 2013
  • The purpose of this study was to evaluate diet-related Quality of Life (QOL) and to analyze the relationship among diet-related QOL, dietary regimen practice, health-related QOL, and gastrointestinal symptoms in hemodialysis patients. Subjects were recruited from an artificial kidney center in Seoul. The self-report questionnaire consisted of socio-demographic characteristics, diet-related QOL, compliance with dietary regimen practice, health-related QOL, and gastrointestinal symptoms was distributed. Diet-related QOL includes a 'Quality of Life and Related to Dietary Change Questionnaire', 'Satisfaction Survey', and 'Dietary Impact Survey'. According to their responses, participants had experienced the greatest difficulty with 'Dietary Impact'. In particular, the mean score for general health was low. Association of dietary regimen practice showed a positive association with 'Cost' and 'Self-care' score. In addition, diet-related QOL showed positive correlation with health-related QOL, particularly in 'taste'. Scores for 'Taste', 'Convenience', and 'Dietary Impact' were lower for subjects with constipation compared to those of subjects without constipation. Scores for 'Taste' and 'Dietary Impact' were lower in subjects with irritable bowel syndrome compared to those of subjects without the syndrome (p < 0.05). Diet-related QOL showed a positive association with health-related QOL (p < 0.05), whereas it showed a negative association with constipation (p < 0.01). In conclusion, hemodialysis patients in Korea suffer from burden of dietary regimen practice and most scores for diet-related QOL and health-related QOL from patients with gastrointestinal symptoms were low. Therefore, appropriate nutrition education considering gastrointestinal symptoms is necessary for improvement of patients' QOL during dietary regimen practice.

Neurotechnologies and civil law issues (뇌신경과학 연구 및 기술에 대한 민사법적 대응)

  • SooJeong Kim
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.2
    • /
    • pp.147-196
    • /
    • 2023
  • Advances in brain science have made it possible to stimulate the brain to treat brain disorder or to connect directly between the neuron activity and an external devices. Non-invasive neurotechnologies already exist, but invasive neurotechnologies can provide more precise stimulation or measure brainwaves more precisely. Nowadays deep brain stimulation (DBS) is recognized as an accepted treatment for Parkinson's disease and essential tremor. In addition DBS has shown a certain positive effect in patients with Alzheimer's disease and depression. Brain-computer interfaces (BCI) are in the clinical stage but help patients in vegetative state can communicate or support rehabilitation for nerve-damaged people. The issue is that the people who need these invasive neurotechnologies are those whose capacity to consent is impaired or who are unable to communicate due to disease or nerve damage, while DBS and BCI operations are highly invasive and require informed consent of patients. Especially in areas where neurotechnology is still in clinical trials, the risks are greater and the benefits are uncertain, so more explanation should be provided to let patients make an informed decision. If the patient is under guardianship, the guardian is able to substitute for the patient's consent, if necessary with the authorization of court. If the patient is not under guardianship and the patient's capacity to consent is impaired or he is unable to express the consent, korean healthcare institution tend to rely on the patient's near relative guardian(de facto guardian) to give consent. But the concept of a de facto guardian is not provided by our civil law system. In the long run, it would be more appropriate to provide that a patient's spouse or next of kin may be authorized to give consent for the patient, if he or she is neither under guardianship nor appointed enduring power of attorney. If the patient was not properly informed of the risks involved in the neurosurgery, he or she may be entitled to compensation of intangible damages. If there is a causal relation between the malpractice and the side effects, the patient may also be able to recover damages for those side effects. In addition, both BCI and DBS involve the implantation of electrodes or microchips in the brain, which are controlled by an external devices. Since implantable medical devices are subject to product liability laws, the patient may be able to sue the manufacturer for damages if the defect caused the adverse effects. Recently, Korea's medical device regulation mandated liability insurance system for implantable medical devices to strengthen consumer protection.

Effect of Nasal Continuous Positive Airway Pressure after Early Surfactant Therapy in Moderate Respiratory Distress Syndrome (중등도 신생아 호흡 곤란 증후군에서 폐 표면 활성제 조기 투여 후 Nasal CPAP의 치료 효과)

  • Kim, Eun Ji;Kim, Hae Sook;Hur, Man Hoe;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.10
    • /
    • pp.1204-1212
    • /
    • 2002
  • Purpose : Early surfactant therapy with either gentle ventilation, high-frequency ventilation or aggressive weaning of mechanical ventilation are principles for the treatment of respiratory distress syndrome(RDS). We studied to determine the accessibility of noninvasive nasal continuous positive airway pressure(CPAP) rather than mechanical ventilation by invasive intubation after early surfactant therapy. Methods : The study group consisted of 14 infants who were born and diagnosed with moderate respiratory distress syndrome and received early surfactant therapy with nasal CPAP of PEEP 5-6 cm $H_2O$ within two hours after birth in the Fatima neonatal intensive care unit for two years from January 1999 to August 2001. The control group consisted of 15 infants who were diagnosed with the disease and could be weaned from mechanical ventilator within five days after birth during the same period. Results : The characteristics, the severity of clinical symptoms and laboratory findings in the two groups at birth showed no significant difference. Neither did the interim analysis of laboratory data in two groups. Of 14 infants in the study group who received nasal CPAP after early surfactant therapy, only two infants showed weaning failure with this therapy. In the response cases, duration of CPAP was five days and mean airway pressure was $5.4{\pm}0.5cm$ $H_2O$. Two had the complication of CPAP with abdominal distension. Final complications and outcomes in the two groups showed no signifcant difference(P>0.05). Conclusion : The clinical courses in the two groups showed no significant difference. Therefore, we suggest that early surfactant therapy with noninvasive nasal CPAP is a simple and safe method rather than aggressive weaning after invasive mechanical ventilation in moderate respiratory distress syndrome.

Pre-operative Concurrent Chemoradiotherapy for Stage IlIA (N2) Non-Small Cell Lung Cancer (N2 병기 비소세포 폐암의 수술 전 동시화학방사선요법)

  • Lee, Kyu-Chan;Ahn, Yong-Chan;Park, Keunchil;Kim, Kwhan-Mien;Kim, Jhin-Gook;Shim, Young-Mog;Lim, Do-Hoon;Kim, Moon-Kyung;Shin, Kyung-Hwan;Kim, Dae-Yong;Huh, Seung-Jae;Rhee, Chong-Heon;Lee, Kyung-Soo
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.100-107
    • /
    • 1999
  • Purpose: This is to evaluate the acute complication, resection rate, and tumor down-staging after pre-operative concurrent chemoradiotherapy for stage IIIA (N2) non-small cell lung cancer. Materials and Methods Fifteen patients with non-small cell lung cancer were enrolled in this study from May 1997 to June 1998 in Samsung Medical Center. The median age of the patients was 61 (range, 45~67) years and male to female ratio was 12:3. Pathologic types were squamous cell carcinoma (11) and adenocarcinoma (4). Pre-operative clinical tumor stages were cT1 in 2 patients, cT2 in T2, and cT3 in 1 and all were N2. Ten patients were proved to be N2 with mediastinoscopic biopsy and five had clinically evident mediastinal Iymph node metastases on the chest CT scans. Pre-operative radiation therapy field included the primary tumor, the ipsilateral hilum, and the mediastinum. Total radiation dose was 45 Gy over 5 weeks with daily dose of 1.8 Gy. Pre-operative concurrent chemotherapy consisted of two cycles of intravenous cis-Platin (100 mg/m$^{2}$) on day 1 and oral Etoposide (50 mg/m$^{2}$/day) on days 1 through 14 with 4 weeks' interval. Surgery was followed after the pre-operative re-evaluation including chest CT scan in 3 weeks of the completion of the concurrent chemoradiotherapy if there was no evidence of disease progression. Results : Full dose radiation therapy was administered to all the 15 patients. Planned two cycles of chemotherapy was completed in 11 patients and one cycle was given to four. One treatment related death of acute respiratory distress syndrome occurred In 15 days of surgery. Hospital admission was required in three patients including one with radiation pneumonitis and two with neutropenic fever. Hematologic complications and other acute complications including esophagitis were tolerable. Resection rate was 92.3% (12/l3) in 13 patients excluding two patients who refused surgery. Pleural seeding was found in one patient after thoracotomy and tumor resection was not feasible. Post-operative tumor stagings were pT0 in 3 patients, pTl in 6, and pT2 in 3. Lymph node status findings were pN0 in 8 patients, pN1 in 1, and pN2 in 3. Pathologic tumor down-staging was 61.5% (8/13) including complete response in three patients ($23.7%). Tumor stage was unchanged in four patients (30.8%) and progression was in one (7.7%). Conclusions : Pre-operative concurrent chemoradiotherapy for Stage IIIA (N2) non-small cell lung cancer demonstrated satisfactory results with no increased severe acute complications. This treatment shceme deserves more patinet accrual with long-term follow-up.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Clinical Analysis According to $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ Expression in Gastric Cancer (위암에서의 $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ 단백 발현)

  • Kim, Sin-Sun;Park, Yong-Geun;Jun, Kyong-Hwa;Jung, Hun;Song, Gyo-Young;Kim, Jin-Joo;Chin, Hyung-Min;Kim, Wook;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Kim, Seung-Nam;Jeon, Hae-Myung
    • Journal of Gastric Cancer
    • /
    • v.6 no.1
    • /
    • pp.36-42
    • /
    • 2006
  • Purpose: The $p21^{Waf1/Cip1}$ protein Inhibits the cell cycle by Inhibiting the phosphorylation at the $G1{\rightarrow}S$ check point, and the $p27^{kip1}$ protein similarly performs the suppressor function by controlling the p27-mediated G1 arrest. In this study, we analysed the clinical status and survival rates in correlations with p21 and p27 expression patterns in gastric cancer. Materials and Methods: Between 1993 and 1997, 192 patients who underwent surgeries in Catholic Medical Center were analysed retrospectively in this study. Immunohistochemical staining was performed and if the nuclei of the tumor cells were stained, we assumed those as positive results. Statistical analysis was based on clinicopathological findings and differences in survival rates. Results: The expression rate of p27 was 28.1% and 15.6% in p21 each. The ratio of T1-2(80.0%) was significantly high in p21 (+), but the ratio of T3-4 (50.6%) was slightly high in p21 (-). There was no statistical significance regarding other factors. The results in p27 was not much different from expression rate of p21 in T-stage. In addition, p27 expression in diffuse type (91.3%) was higher than in intestinal type (62.7%) by Lauren's classification (P<0.05). Also, there was no statistical significance in other factors. In the correlation of p21 and p27, p27 was positive when p21 was positive (53.5%). Conversely, p27 was negative when p21 was negative (76.5%, p<0.05). In the p21 and p27 combination test, there was higher rate of T1-2 (87.5%) in p21 (+)/p27 (+), and higher rate of T3-4 (58.1%) in p21 (-)/p27 (-) (P<0.05). Results showed higher rate of intestinal type (100%) in p21 (+)/p27 (+), and diffuse type (87.0%) was dominant in p21 (-)/p27 (-) (P<0.05) by Lauren's classification. Moreover, there was no statistical significance in the 5-year survival rate in the expression of p21 and p27, and the 5-year survival rate was highest in the case of p21 (+)/p27 (+) without statistical significance. Conclusion: In our study, $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ expressed similar patterns. The expression of $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ affected the degree of invasiveness of the tumor, and. Combined examination result revealed the correlation of $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ with Lauren's classification and depth of invasion of the tumor. However, we assumed that little difference between the survival rates depending on expression of $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ has limited their value as predictable prognostic indicators.

  • PDF

The Role of Intraluminal Brachytherapy in Management of Esophageal Cancer (식도암 치료에 있어 관내근접치료의 역할)

  • Lee Chang Geol;Suh Chang Ok;Kim Gwi Eon;Chu Sung Sil;Chung Eun Ji;Kim Woo Cheol
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.331-338
    • /
    • 1995
  • Purpose : To evaluate our clinical experience with the combination of teletherapy and intraluminal brachytherapy in patients with unresectable or inoperable esophageal cancers. Materials and Methods : From Nov 1989 to Mar 1993, twenty patients with esophageal cancer were treated with radical radiotherapy and intraluminal brachytherapy at Yonsei Cancer Center. All patients had squamous histolgy and stage distribution was as follows: stage II, 4($20{\%}$)patients; III, 15 ($75{\%}$)patients; IV, 1($5{\%}$)patients. A dose of S-12Gy/1-3weeks with intraluminal brachytherapy (3-5Gy/fraction) to 5mm from the outside of the esophageal tube using high dose rate Iridium-192 remotely afterloading brachytherapy machine was given 2 weeks after a total dose of 59-64Gy with external radiotherapy. Induction chemotherapy using cisplatin and 5-FU was performed in 13 patients with median 3 cycles(1-6 cycles), Response rate, local control rate, survival and complications were analysed retrospectively. Results : Two-year overall survival rate and median survival were $15.8{\%}$ and 13.5 months. Response rates were as follows complete remission(CR) 5($25{\%}$): partial remission a(PRa) 7($35{\%}$): partial remission b(PRb) 7($35{\%}$), no response(NR) 1($5{\%}$). Patterns of failure were as follows; local failure 13($65{\%}$), local and distant failure 3($15{\%}$), distant failure 0($0{\%}$). Ultimate local control rate was $20{\%}$. Treatment related complications included esophageal ulcer in two patients and esophageal stricture in one. Conclusion : Though poor local conrol rate, median survival was improved as compared with previous results of radiation therapy alone(8months) and chemoradiation combined treatment(11 months) in Yonsei Cancer Center High-dose-rate intraluminal brachytherapy following external irradiation is an effective treatment modality with acceptable toxicity in esophageal cancer.

  • PDF