• Title/Summary/Keyword: climate system

Search Result 2,577, Processing Time 0.025 seconds

A Study on Climate Characteristics of Waterfront in Busan Area (부산지역 워터프런트의 기후특성에 관한 연구)

  • Doe, Geun-Young;Lee, Han-Seok;Koh, Sung-Cheol;Hyun, Beom-Soo;Yoo, Jong-Su
    • Journal of Navigation and Port Research
    • /
    • v.26 no.4
    • /
    • pp.465-472
    • /
    • 2002
  • The waterfront has distinct climate characteristics different from urban or inland area. These may create not only the rise of energy and maintenance costs for facilities located at waterfront areas, but also the negative effects on the climate of the nearby inland area, unless these are treated with particular care. For the present study, the climate characteristics of waterfront were examined with climate data of 10 observation points carefully selected in Busan area. Each weather observation point was classified into either waterfront area of inland area, based on the distance from the coastal line. Special considerations were given to the climate data gathered at the Dae-Yeon weather station because it shows the climate characteristics similar to those of inland area, although it is located very near the waterfront area. Results indicates that this peculiar climate condition attributes, at least in part, to the reclamation of frontal coastal area.

The relationship between safety climate and occupational accident (안전분위기와 산업재해와의 관계에 대한 연구)

  • 안관영
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • With Zohar(1980)'s research on safety climate and industrial safety, occupational safety and health literatures begin to emphasize the influence of organizational context. Based on this research trend, this paper tried to review the relationship between individual/ organizational factors and occupational accidents. Based on the responses from 643 manufacturing workers, this paper reviewed the relationship between antecedents(safety knowledge, safety motivation, safety education, and safety precaution activity) and safety consequences(accident parts, accident number, resting days). The results of statistical analysis showed that many antecedents have significantly negative relationships with safety consequences.

The Planning of Micro-climate Control by Complex Types (단지 유형에 따른 도시의 미기후 조절 계획에 관한 연구)

  • Jeong, Juri;Chung, Min Hee
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.49-54
    • /
    • 2017
  • Purpose: Temperature in urban areas increase much more than suburban areas and it is called urban heat island (UHI) phenomenon. There are several solutions to control UHI phenomenon such as green roof system, water space construction, and cool roof system. However, application of green roof system and cool roof system to some of the buildings which compose the city has a critical limit. Therefore, in order to diminish the temperature rising and UHI phenomenon due to climate change of the city, it needs to approach from the viewpoint of site or city, rather than the viewpoint of individual buildings. This study is aims at analyzing UHI phenomenon by characteristics of surface materials and suggesting the solutions to reduce UHI phenomenon by types of complex. Method: Literature reviews were conducted to analyze the cause, mitigating plan, and recent trends of UHI phenomenon. For the simulation analysis, the type of complex was classified 3 representative complex. Based on measured reflectivity, simulation about UHI phenomenon was conducted by setting 4 strategies; albedo of roof, road pavement, green roof system, and vegetating around buildings. Result: As the results of simulating the UHI reduction factor by types of complex, it showed that the effect of temperature reduction on the building roof layer is more effective than adjusting the reflectivity of buildings such as green roof system, planting near the buildings in both the detached house complex, apartment complex, and commercial complex.

Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change (기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구)

  • Yoon, Yong-Han;Kwon, Ki-Uk
    • Journal of Environmental Science International
    • /
    • v.27 no.12
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.

Evaluation on the Indoor Thermal Environment and Cooling Operation Characteristics of Thermally Activated Building System integrated with Dedicated Outdoor Air System during Cooling Operation in Hot and Humid Climate of Seoul (국내 여름철 기후조건에서 DOAS와 TABS 통합시스템 냉방운전시 실내온열환경 및 운전특성 평가)

  • Lee, YoonSun;Lee, Keo-Re;Chung, Woong June;Lim, Jae-Han
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.45-55
    • /
    • 2018
  • To reduce the energy consumption of HVAC system in buildings, thermally activated building system(TABS) has been applied to low energy building because of energy efficient performance and reduction of peak load. DOAS coupled with a parallel sensible cooling could be promising because TABS handles sensible heat load only. The purpose of this study was to evaluate the indoor thermal environment and cooling operation characteristic of TABS with dedicated outdoor air system(DOAS) in Korea climate. Indoor thermal environment and operation characteristic of TABS integrated with DOAS are investigated at different TABS operation schedules and climate conditions by simulation tests. The result shows that the DOAS is more suitable for hot and humid climates. And also it show that the potential of intermittent operation of TABS.

Simulation of Dynamic Characteristics of a Trigenerative Climate Control System Based On Peltier Thermoelectric Modules

  • Vasilyev, G.S.;Kuzichkin, O.R.;Surzhik, D.I.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.252-257
    • /
    • 2021
  • The application of the principle of trigeneration allows to simultaneously provide electricity to power electronic devices, as well as heat and cold to create the necessary microclimate of the premises and increase efficiency compared to separate cooling and heating systems. The use of Peltier thermoelectric modules (TEM) as part of trigenerative systems allows for smooth and precise control of the temperature regime, high manufacturability and reliability due to the absence of moving parts, resistance to shock and vibration, and small weight and size parameters of the system. One of the promising areas of improvement of trigenerative systems is their modeling and optimization based on the automatic control theory. A block diagram and functional model of an energy-saving trigenerative climate control system based on Peltier modules are developed, and the transfer functions of an open and closed system are obtained. The simulation of the transient characteristics of the system with varying parameters of the components is performed. The directions for improving the quality of transients in the climate control system are determined, as well as the prospects of the proposed methodology for modeling and analyzing control systems operating in substantially nonlinear modes.

A Study on the System for measuring the Activity of Honeybees inside and outside the Beehive

  • Kim, Joon Ho;Han, Wook;Chung, Wonki;Mo, Changyeon;Han, Xiongzhe;Kim, Subae
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.511-517
    • /
    • 2022
  • Recently, due to rapid climate change, the population of honey bees has decreased, posing a great threat to the existence of the Earth's ecosystem. In particular, the colony collapse phenomenon in which bees disappeared nationwide in early 2022 had devastating consequences for beekeepers. In order to solve the problems of beekeeping due to climate change, it is urgent to develop a system that can monitor the situation inside the hive through various IoT sensors. This paper develops a system that can measure the activity of bees inside the hive and uses it to measure the number of times of entry and exit of the hive. The data measured by the developed system can be monitored in real time on a smartphone through the cloud server. The system developed in this paper can monitor the ecology of bees according to climate change and measure internal and external bee activities. Using this method, it is possible to check in advance for the colony collapse phenomenon in which bees disappeared in early 2022. This is very meaningful in that it presents an alternative that can identify the cause of the problem through early detection.

Review of Policy Direction and Coupled Model Development between Groundwater Recharge Quantity and Climate Change (기후변화 연동 지하수 함양량 산정 모델 개발 및 정책방향 고찰)

  • Lee, Moung-Jin;Lee, Joung-Ho;Jeon, Seong-Woo;Houng, Hyun-Jung
    • Journal of Environmental Policy
    • /
    • v.9 no.2
    • /
    • pp.157-184
    • /
    • 2010
  • Global climate change is destroying the water circulation balance by changing rates of precipitation, recharge and discharge, and evapotranspiration. The Intergovernmental Panel on Climate Change (IPCC 2007) makes "changes in rainfall pattern due to climate system changes and consequent shortage of available water resource" a high priority as the weakest part among the effects of human environment caused by future climate changes. Groundwater, which occupies a considerable portion of the world's water resources, is related to climate change via surface water such as rivers, lakes, and marshes, and "direct" interactions, being indirectly affected through recharge. Therefore, in order to quantify the effects of climate change on groundwater resources, it is necessary to not only predict the main variables of climate change but to also accurately predict the underground rainfall recharge quantity. In this paper, the authors selected a relevant climate change scenario, In this context, the authors selected A1B from the Special Report on Emission Scenario (SRES) which is distributed at Korea Meteorological Administration. By using data on temperature, rainfall, soil, and land use, the groundwater recharge rate for the research area was estimated by period and embodied as geographic information system (GIS). In order to calculate the groundwater recharge quantity, Visual HELP3 was used as main model for groundwater recharge, and the physical properties of weather, temperature, and soil layers were used as main input data. General changes to water circulation due to climate change have already been predicted. In order to systematically solve problems associated with how the groundwater resource circulation system should be reflected in future policies pertaining to groundwater resources, it may be urgent to recalculate the groundwater recharge quantity and consequent quantity for using via prediction of climate change in Korea in the future and then reflection of the results. The space-time calculation of changes to the groundwater recharge quantity in the study area may serve as a foundation to present additional measures for the improved management of domestic groundwater resources.

  • PDF

Evaluation of Practical Application of the Remote Monitoring System for Water Salinity in Estuary Lake During Farming Season

  • Lee, Kyung-Do;Hong, Suk-Young;Kim, Yi-Hyun;Na, Sang-Il;Oh, Young-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.5
    • /
    • pp.313-318
    • /
    • 2014
  • The remote monitoring system of water salinity was assessed in Wando reclaimed land lake during a farming season in 2009. Increasing of water salinity in this lake used to bring about salt damage on rice plant occasionally. At the early stage of the rice growing period, rice growth was not damaged due to enough rainfall with more than 120 mm from the mid-May to the first ten days of June. Data collection using on-site water salinity measuring sensors every 2 hours and real-time transmission in system were carried out for the experiment. We compared the transmitted values from the sensor system with water sample values collected and analyzed by a local technical office. Salt concentrations measured by sensor in real-time monitoring system were available data. The regression equation between rainfall and water salinity was presented as (water salinity after rainfall) = $0.621{\times}$(water salinity before rainfall)${\times}exp(-0.0139{\times}rainfall)$, ($r^2=0.579$, p<0.01). It is suggested that the system is useful for stable farming in the area where farmer use water in reclaimed lakes as an irrigation source.

A Study on Battery Charging and Supply System of Electric Vehicle Using Photovoltaic Generation (태양광 발전을 이용한 전기자동차 배터리 충전 및 공급시스템에 관한 연구)

  • Choi, Hoi-Kyun
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.265-273
    • /
    • 2017
  • Recently the Paris Climate Change Accord has been officially put into effect, making global efforts to implement Greenhouse Gas (GHG) reductions, and also International environmental regulations in the automotive sector will be further strengthened. The electric vehicle, which minimizes the particulate matter generated by existing internal combustion engine automobiles, is evaluated as a representative eco-friendly automobile. However, charging the battery of an electric vehicle is not fully environment-friendly if it is fueled by electricity that is being generated by fossil fuels as an energy source. The energy generated by the photovoltaic power generation system, which is an infinite clean energy, can be used to charge an electric vehicle's battery. Currently, shortage of charging facilities, time of charging, and high battery prices are the problem of activating the supply of electric vehicles. This study is to build a conjunction between the EVBSS (Electric Vehicle Battery Supply System) and ESS (Energy Storage System), which can quickly supply the photovoltaic charged battery to the required demand. If the charged battery in the Battery Swapping Station (BSS) is swapped swiftly, it will dramatically shorten the waiting time for charging the battery. As a result, if the battery is rented when it is needed, electric vehicles can be sold without the cost of a battery, which accounts for a large portion of the total cost, then the supply of electric vehicles are expected to expand. Furthermore, it will be an important alternative to maneuver climate change by minimizing GHG emissions from internal combustion engine vehicles.