• 제목/요약/키워드: class V

검색결과 1,025건 처리시간 0.028초

다른 굵기의 6/10[kV]급 CV 케이블 직선접속부 안전성 평가 (A Safety Assessment of Splice of 6/10[kV] Class CV Cables with Different Conductor Size)

  • 정종욱;김선구;정진수
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.78-84
    • /
    • 2010
  • This paper describes the safety assessment of power cable splices connecting different sized 6/10[kV] class power cables. To assess the safety, AC withstand voltage tests, partial discharge tests and impulse tests were carried out to the cable splice specimens and thermal rise due to overload and cross section of joint were examined as well. As a result, a breakdown due to the $4.5[U_0](27[kV_{ac}])$ application could not found for 5 minutes. Under $1.73[U_0](10.4[kV_{ac}])$ application, partial discharges of 4~8[pC] were detected. In impulse tests, all the specimens withstood to the standard waveforms of $75[kV_{peak}](1.2{\times}50[{\mu}s])$ without any breakdowns. In addition, the temperature on the splice rose by $3[^{\circ}C]$ when the 200[A] flew through the splice for 20minutes, however the thermal rise of $3[^{\circ}C]$ was considered due to the atmospheric temperature. After all the electrical tests, the cross section of the splice was visually examined. The conditions of the conductors of both $185[mm^2]$ and $240[mm^2]$ were good.

LCD 드라이버에 적용 가능한 저소비전력 및 높은 슬루율을 갖는 이중 레일 투 레일 버퍼 증폭기 (A Low-Power High Slew-Rate Rail to Rail Dual Buffer Amplifier for LCD output Driver)

  • 이민우;강병준;김한슬;한정우;손상희;정원섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.726-729
    • /
    • 2013
  • 본 논문에서는 LCD source driver IC의 output buffer op-amp로 사용가능한 저소비전력 및 높은 슬루율을 갖는 CMOS rail-to rail 입/출력 op-amp를 설계하였다. 제안한 op-amp는 기존의 출력단 Class-AB 단에 새로이 설계한 Class-B control단을 추가하여 저소비전력과 높은 슬루율을 갖게 하였다. 시뮬레이션 결과 제안된 op-amp는 소비전력이 1.19mW로 감소하였으며 사용한 부하커패시터 (10nF)를 기준으로 슬루율은 6.5V/us로 확인되었다.

  • PDF

전류영점 영역에서 파퍼식 SF6 가스차단기의 아크 컨덕턴스에 관한 연구 (A Study on Arc Conductance of Puffer Type SF6 GCB at Current Zero Period)

  • 정진교;송기동;이우영;김규탁
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.328-332
    • /
    • 2010
  • The SLF(Short Line Fault) breaking capability test for high voltage class $SF_6$ GCB(Gas Circuit Breaker) was conducted. Simplified LC resonant circuit test facility was used for SLF breaking test. During test, Test current was measured by Rogwski coil and arc voltage was measured by voltage divider. Arc conductance was calculated by using these test results before 200ns at current zero. Critical arc conductance value at rated voltage 145kV class is about 2.3mS regardless of breaking current magnitude and arc conductance value at rated voltage 170kV class is about 2.6mS.

154 kV급 고온초전도 변압기의 전기절연 설계 (Electrical Insulation Design of a 154 kV Class HTS Transformer)

  • 천현권;곽동순;최재형;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.53-56
    • /
    • 2007
  • In the response to the demand for electrical energy, much effort was given to develop and commercialize high temperature superconducting (HTS) power equipment has been made around the world. Especially, a HTS transformer is one of the most promising devices. Recently, Korea Polytechnic University and Gyeongsang National University are developing a power distribution and transmission class HTS transformer that is one of the 21st century superconducting frontier projects in Korea. For the development of 154 kV class HTS transformer, the cryogenic insulation technology should be established. We have been analyzed insulation composition and investigated electrical characteristics such as the breakdown of $LN_2$, barrier, kapton films, and the surface flashover of FRP in $LN_2$. Furthermore, we are going to compare with measured each value and apply the value to the most suitable insulating design of the HTS transformer.

Almost Kenmotsu Metrics with Quasi Yamabe Soliton

  • Pradip Majhi;Dibakar Dey
    • Kyungpook Mathematical Journal
    • /
    • 제63권1호
    • /
    • pp.97-104
    • /
    • 2023
  • In the present paper, we characterize, for a class of almost Kenmotsu manifolds, those that admit quasi Yamabe solitons. We show that if a (k, 𝜇)'-almost Kenmotsu manifold admits a quasi Yamabe soliton (g, V, 𝜆, 𝛼) where V is pointwise collinear with 𝜉, then (1) V is a constant multiple of 𝜉, (2) V is a strict infinitesimal contact transformation, and (3) (£Vh')X = 0 holds for any vector field X. We present an illustrative example to support the result.

근거리 무선전력전송용 공진형 Class ${\phi}_2$ 인버터 동작 특성 (The characteristics of Resonant class ${\phi}_2$ Inverter for short range wireless power transmission)

  • 양해열;박재현;김창선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.13-14
    • /
    • 2011
  • The power conversion converter for driving the wireless power transfer system is can be into the two part of the DC power conversion rectifier and the high frequency dc-ac power conversion inverter. In this paper, The operating characteristics of the Class-${\Phi}_2$ resonant inverter have been investigated through by simulation and by experiment. It can be switched at a high frequency without the switching losses and the harmonics are reduced effectively due to the input LC filter. Its switching frequency is 1MHz and the input voltage is 96V which is the output voltage of LLC resonant converter. And its output peak voltage is 170V. The resonant inverter module operated at the commercial power source of 220V was built. And also the electromagnetic coupled resonance coils were designed for wireless power transfer with a 1MHz operating frequency. As a experimental result, the wireless power transmission was confirmed and it is varified the validity of the experiment.

  • PDF

권선형기기 On-line 부분방전 측정용 6-6kV급 Ceramic Coupler의 신뢰성 평가 (Evaluation of Reliability on the 6.6kV Class Ceramic Coupler for On-line Partial Discharge Measurement in Winding Machines)

  • 강동식;김용주;윤영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.69-75
    • /
    • 2005
  • In order to improve the reliability of high voltage rotating machines and mold transformers, it is necessary to understand the breakdown mechanism and life assessment of the high voltage winding parts. Especially the on-line PD test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting the electrical machines, this method has been proven the major testing technology. Capacitive couplers have been the most widely used sensors for the on-line partial discharge detection in rotating machines nowadays. This paper deals with the electrical characteristics and long-term reliability of a ceramic coupler(CC), which can be easily mounted into high voltage input terminal part, has been developed and tested to continuously measure PD activity during operating condition. This paper presents electrical characteristics (dielectric loss angle, capacitance, PD inception level, breakdown voltage, and frequency response bandwidth) and long-term life test result of the developed 6.6 kV class on-line ceramic coupling sensor. It was found that this sensor had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz. Also, the voltage life of the 6.6kV class ceramic coupler was calculated over 60 years.

전차선로용 폴리머 피뢰기(42kV 10kA Class3)의 전기적 특성 및 누설전류 특성 평가 (Evaluation of Electrical and Leakage Current Characteristics of Polymer Arrester(42kV 10kA Class3) for Railroad Line)

  • 김석수;최익순;박춘현;조이곤;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1171-1174
    • /
    • 2004
  • Leakage current of the polymer arrester(42kV, 10kA, Class3) for railroad line applied actually field was observed and electrical characteristics of arrester before and after applied actually field were investigated. During applied actually field, leakage current of arresters were $610{\sim}647{\mu}A$ in AN SAN line and $500{\mu}A$ in YUNG DONG line. After applied actually field, electrical characteristics of arrester, such as insulation test, reference voltage test, leakage current test and partial discharge current test, wasn't variation as before applied actually field.

  • PDF

13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가 (Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator)

  • 선종호;황돈하;윤영호;신병철;오봉근;강동식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

복합(複合) resin의 변록누출(邊綠漏出)에 관(關)한 실험적(實驗的) 연구(硏究) (A STUDY ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN)

  • 조진호
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.131-138
    • /
    • 1981
  • The purpose of this study was to evaluate the marginal leakage of composite resin. Preparing 144 class V cavities on freshly extracted noncarious teeth, composite resins were prepared and inserted by one dentist according to the manufacturer's instructions. The experiments were performed in two different groups; In group I; Class V cavities with $90^{\circ}$ cavosurface angle, In group II; Class V cavities with $135^{\circ}$ cavosurface angle. And each group was divided 2 subgroups; In control group; composite resin restoraions without acid etch technique. In experimental group; composite resin restorations with acid etch technique. All specimens were immersed in 0.05% crystal violet solution. Before examination, the restored teeth were subjected to thermal stress. The specimens were sectioned occlusogingivally through the center of the restorations with a diamond disk. The sections were examined under a reflected light microscope at 1 day, 7 days and 30 days after immersing the specimens in dye solution. The results were as follows; 1. Control group of group I and group II showed marginal leakage. 2. The degree of marginal leakage in experimental group was greater reduced than control group. 3. In control group, the degree of marginal leakage in group I was greater than group II. 4. In experimental group, there is not statistical differences of the degree of marginal leakage between group I & group II.

  • PDF