• Title/Summary/Keyword: clamp

Search Result 1,105, Processing Time 0.036 seconds

Interspecific protoplast Fusion and Sexuality in Pleurotus (느타리의 종간(種間) 원형질체(原形質體) 융합(融合) 및 유성(有性))

  • Yoo, Young-Bok;You, Chang-Hyun;Park, Yong-Hwan;Lee, Yeon-Hee;Chang, Kwon-Yawl;Peberdy, John F.
    • The Korean Journal of Mycology
    • /
    • v.15 no.3
    • /
    • pp.135-141
    • /
    • 1987
  • Interspecific heterokaryons were obtained by polyethylene glycol induced fusion of protoplasts from auxotrophic mutants of P. ostreatus+P. cornucopiae, P. ostreatus+P. florida, P. ostreatus+P. sajor-caju, P. florida+P. cornucopiae, P. florida+P. sajor-caju and P. sajor-caju+P. cornucopiae protoplasts. The Fusion products of protoplasts were induced by MCM+benomyl, but segregation of sectors were not identified. Interspecific fusion products of protoplasts between incompatible strains did not form true clamp connections and did not produce fruit bodies. For induction of fertility, interspecific heterokaryons crossed with their parents by hyphal anastomosis.

  • PDF

A Study on PFC of Active Clamp ZVS Flyback Converter (능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구)

  • 최태영;류동균;이우석;안정준;원충연;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.49-57
    • /
    • 2001
  • This paper analyzed PFC of active clamp ZVS flybark converter by adding two method PFC (Power Factor Correction) circuit-two-stage and single-stage. The addition of active clamp circuit also provide a mechanism fur achieving ZVS of both the primary and auxiliary switches. ZVS also limits the turn off di/dt of the output rectifier, reducing rectifier switching loss and switching noise, due to diode reverse recovery. As a results, the proposed converters have characteristics of the reduced switching noise and high efficiency in comparison to conventional flyback converter. The simulation and experimental results show that the proposed converters improve the input PF of 300[W] ZVS flyback converter by adding single-stage two-stage PFC circuit.

  • PDF

Design of the Various Capacity Wedge-type Rail Clamp for a Quay crane According to the Design Wind Speed Criteria Change (설계 풍속 상향 조정에 따른 Quay crane용 제용량 쐐기형 레일 클램프 설계)

  • Lee J.M.;Han G.J.;Shim J.J.;Han D.S.;Lee S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1626-1629
    • /
    • 2005
  • Recently many countries have concentrated their effort on the port automation, in order to be the Hub-port, that the Ultra Large Container Ship could come alongside the Quay, in their region. As the magnitude of the container ship increase, that of the Quay crane increases from 50ton-class to 61ton-class more and more. The wind speed criteria to design the structures used in the port was upgraded from 20m/s to 40m/s due to change of the weather condition. Our laboratory could have the ability to design the wedge type rail clamp for 50ton-class Quay crane in 30m/s wind speed. Accordingly we analyzed the load condition of the Quay crane about 40m/s wind speed upgraded from 20m/s and designed the wedge type rail clamp for 50ton and 61ton-class Quay crane.

  • PDF

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

Forward Converter Using 300W Planar Transformer (300W 평면 변압기적용 포워드 컨버터)

  • Choi, S.H;Park J.Y;Kim E.S
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.560-567
    • /
    • 2004
  • In this paper, the design and implementation of a high power(300W) forward converter using a planar transformer is presented. The overall size and volume of the converter is decreased by replacing a planar transformer in stead of using a conventional winding transformer. Due to the decreased size and volume, power density of the applied forward converter is increased. Also, in this paper, the 300W ZVS forward converter with active clamp snubber circuit is compared to the 300W hard switching forward converter planar transformer, the decreased size and volume, the 300W ZVS forward converter with active clamp snubber circuit, 30W hard switching forward converter.

Non-explosive Separation Device Harnessing Spring Clamp and Shape Memory Alloy Wire (스프링 클램프와 형상기억합금 와이어를 이용한 비폭발식 분리장치)

  • Choi, Junwoo;Lee, Dongkyu;Hwang, Kukha;Lee, Minhyung;Kim, Byungkyu
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.2
    • /
    • pp.7-12
    • /
    • 2015
  • In this paper, we report a non-explosive separation device for a small satellite which utilize a shape memory alloy actuator and spring clamp. In order to increase the preload, the proposed device employs spring clamp that can generate high toque when the shape memory alloy actuator makes the cylinder key unlatch a holding ball effectively. Owing to simple design of separation device configuration, we could obtain good repeatability(up to 30 times activation). Conclusively, we could develop a non-explosive separation device which can reliably activate within 1.2 sec under high preload(up to 300kgf).

Clamp-mode Three-level High Voltage Gain Boost Converter using Coupled Inductor (결합인덕터를 이용한 전압 클램프 3-레벨 고승압 컨버터)

  • Kim, Su-Han;Cha, Hon-Nyong;Kim, Heung-Geun;Choi, Byung-Cho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.500-506
    • /
    • 2012
  • In this paper, a non-isolated high step-up and high efficiency boost converter is proposed. By using the 3-level boost converter structure, the proposed converter can obtain higher voltage gain than conventional high step-up converters. The voltage spike of the switching device is well clamped by using the clamp circuit composed of a clamp diode and a capacitor and the energy of the leakage inductor of coupled inductor is effectively transferred to output. Due to the 3-level structure, the equivalent switching frequency of the coupled inductor is doubled, which results in reduced inductor size. A 500 W prototype converter is built and tested to verify performance of the proposed converter.

Broken Mayfield Head Clamp

  • Lee, Tae-Hoon;Kim, Sang-Jin;Cho, Do-Sang
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.5
    • /
    • pp.306-308
    • /
    • 2009
  • The Mayfield head clamp is the most frequently used head clamp system in the field of neurosurgery. In many cases, surgery is performed with complete reliance on the safety of the MHC. However, we experienced an extremely rare case in which the MHC accidentally broke while installing this system for immobilization of the head and neck. This is a case report with a brief review of the literature. The patient was a 58-year-old female who was scheduled to undergo cervical laminoplasty under the diagnosis of degenerative spondylotic cervical stenosis. In an attempt to install an MHC, we fixed three pins in the scalp; however, the arm of the MHC system broke when force was applied from both directions. Fortunately, the patient remained in a stable position and did not sustain an injury to the head or neck. Fixation was performed using another MHC, and the surgery was performed successfully. The patient was discharged after surgery with no specific complications related to the MHC system. The authors experienced an extremely rare case of MHC breakage during application and report the importance of properly managing and maintaining the instruments in order to prevent fatal injury.

High Efficiency Active Clamp Forward Converter with Synchronous Switch Controlled ZVS Operation

  • Lee Sung-Sae;Choi Seong-Wook;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.131-138
    • /
    • 2006
  • An active clamp ZVS PWM forward converter using a secondary synchronous switch control is proposed in this paper. The proposed converter is suitable for low-voltage and high-current applications. The structure of the proposed converter is the same as a conventional active clamp forward converter. However, since it controls the secondary synchronous switch to build up the primary current during a very short period of time, the ZVS operation is easily achieved without any additional conduction losses of magnetizing current in the transformer and clamp circuit. Furthermore, there are no additional circuits required for the ZVS operation of power switches. Therefore, the proposed converter can achieve high efficiency with low EMI noise, resulting from soft switching without any additional conduction losses, and shows high power dens~ty, a result of high efficiency, and requires no additional components. The operational principle and design example are presented. Experimental results demonstrate that the proposed converter can achieve an excellent ZVS performance throughout all load conditions and demonstrates significant improvement in efficiency for the 100W (5V, 20A) prototype converter.