• 제목/요약/키워드: circumferential thinning angle

검색결과 12건 처리시간 0.016초

실배관 파열실험을 통한 국부감육 곡관 손상압력 평가 (Failure Pressure Evaluation of Local Wall-Thinned Elbows by Real-scale Burst Tests)

  • 김진원;박치용;이성호
    • 대한기계학회논문집A
    • /
    • 제31권10호
    • /
    • pp.1017-1024
    • /
    • 2007
  • This study performed a series of burst tests at ambient temperature using real-scale elbow specimen containing a local wall-thinning defect at it's intrados or extrados and evaluated failure pressure of locally wall-thinned elbows. In the experiment, a 90-degree 100A, Sch. 80 standard elbow was employed, and various wall-thinning geometries, such as length, depth, and circumferential angle, were considered. From the results of experiment, the dependences of failure pressure of wall-thinned elbows on the defect geometries and locations were investigated. In addition, the reliability of existing models was examined by comparing the tests data with the results predicted from existing failure pressure evaluation models for locally wall-thinned elbow.

적외선열화상 카메라를 이용한 원전 소구경 감육배관의 결함 검출 (Application Defects Detection in the Small-Bore Pipe Using Infrared Thermography Technique)

  • 윤경원;김동률;정현철;홍동표;김경석
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.34-39
    • /
    • 2013
  • 선행 연구에서 적외선열화상기법을 이용하여 원전 배관의 감육 결함을 측정하기 위하여, 4 inch 배관에 인공결함을 가공하여 이에 대한 결함 검출을 도출하였다. 본 논문에서는 선행연구에서 도출된 조건을 이용하여 원전 소구경 배관의 결함 검출 조건에 관한 연구를 수행하였다. 결함의 가공은 감육 길이, 원주방향 각도, 감육 깊이를 변화시켜서 결함 조건을 가공하였다. 사용된 장비는 IR camera와 1 kW용량의 halogen lamp 2개를 사용하였으며, halogen lamp와 대상 배관과의 거리를 1 m, 1.5 m, 2 m 순으로 변화시켜 실험을 수행하였다. 실험 결과의 분석을 위하여 온도분포데이터를 확보하고, 이를 분석하여 결함 길이를 측정하였다. 4 inch 배관의 인공결함은 2 m에서 측정 결과의 신뢰도가 높았으나, 소구경 배관은 1.5 m에서 결함이 명확하게 검출되었다.