• Title/Summary/Keyword: circulation of water

Search Result 1,212, Processing Time 0.026 seconds

Application of chemically enhanced backwash coping with algal inflow in desalination pretreatment using ceramic membrane (세라믹 분리막을 이용한 해수담수화 전처리 공정에서 조류 유입에 대한 유지세정 적용)

  • Kang, Joon-Seok;Park, Seo-Gyeong;Lee, Jeong-Jun;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.97-106
    • /
    • 2018
  • In this study, the effect of chemically enhanced backwash(CEB) coping with algal(Heterosigma Akashiwo) inflow was evaluated in the seawater desalination pretreatment process using ceramic membrane. In order to confirm the possibility of long-term filtration operation, the recovery rate of transmembrane pressure(TMP) due to the CEB using NaOCl was examined. When the membrane flow rate was 83.3 LMH, the TMP was maintained within 200 kPa for 84 hours in seawater influent. As the algal counts of 30,000 cell/mL were injected into the influent of seawater, however, the TMP rapidly increased and exceed maximum value. Membrane fouling caused by the algae was very poorly recovered by usual physical backwash. The CEB was performed for 30 min(3 min circulation / 27 min immersion) with 300 mg/L of NaOCl. As a result of the CEB application, it was possible to maintain a stable operating of filtration during 10 days and the average recovery rate of TMP by the CEB was 98.1%. It has been confirmed that the CEB using NaOCl is very effective in removal of membrane fouling by algae, resulted in stable membrane filtration for the long-term operation.

Novel Antihypertension Mechanism of 𝛽-Glucan by Corin and ANP-Mediated Natriuresis in Mice

  • Lee, Sun Jung;Lee, Dong Hee;Kim, Ha Won
    • Mycobiology
    • /
    • v.48 no.5
    • /
    • pp.399-409
    • /
    • 2020
  • Many of the 𝛽-glucans are known to have antihypertensive activities, but, except for angiotensin-converting enzyme II inhibition, the underlying mechanisms remain unclear. Corin is an atrial natriuretic peptide (ANP)-converting enzyme. Activated corin cleaves pro-ANP to ANP, which regulates water-sodium balance and lowers blood pressure. Here, we reported a novel antihypertensive mechanism of 𝛽-glucans, involved with corin and ANP in mice. We showed that multiple oral administrations of 𝛽-glucan induced the expression of corin and ANP, and also increased natriuresis in mice. Microarray analysis showed that corin gene expression was only upregulated in mice liver by multiple, not single, oral administrations of the 𝛽-glucan fraction of Phellinus baumii (BGF). Corin was induced in liver and kidney tissues by the 𝛽-glucans from zymosan and barley, as well as by BGF. In addition to P. baumii, 𝛽-glucans from two other mushrooms, Phellinus linteus and Ganoderma lucidum, also induced corin mRNA expression in mouse liver. ELISA immunoassays showed that ANP production was increased in liver tissue by all the 𝛽-glucans tested, but not in the heart and kidney. Urinary sodium excretion was significantly increased by treatment with 𝛽-glucans in the order of BGF, zymosan, and barley, both in 1% normal and 10% high-sodium diets. In conclusion, we found that the oral administration of 𝛽-glucans could induce corin expression, ANP production, and sodium excretion in mice. Our findings will be helpful for investigations of 𝛽-glucans in corin and ANP-related fields, including blood pressure, salt-water balance, and circulation.

Development of Heating and Cooling System with Heat Pump for Nutrient Solution Bed In Greenhouse (열펌프를 이용한 양액베드 냉난방시스템 개발)

  • Kang, Geum-Chun;Kim, Yeong-Jung;Yu, Yeong-Seon;Baek, Lee
    • Journal of Biosystems Engineering
    • /
    • v.27 no.6
    • /
    • pp.565-572
    • /
    • 2002
  • In order to control the root-zone temperature of greenhouse crops in the hydroponics at hot and cold season, heat pump system for cooling and heating was built and tested in this work. The system was air-to-water type and vapour compression type. The heating and cooling mode was selected by the four way valve. Capacity of the compressor was 3.75㎾ and heat transfer area of the evaporator and the condenser were 3.05㎡ and 0.6㎡, respectively. According to the performance test, it could supply heat of 42,360 to 64,372kJ/h depending on the water circulation rate of 600 to 1,500ℓ/h, respectively, when indoor air temperature was 10∼20$\^{C}$. COP of heat pump system was 3.0 to 4.0 in the heating mode. But, COP of the cooling mode was 1.3 to 2.1 at indoor temperature of 20∼35$\^{C}$. The feasibility test in the greenhouse the developed heating and cooling system was installed, showed that the heating cost of the developed system was only about 13% of that of the conventional heating system. The heating cost of the developed system was 367won/day(electric consumption 9.7㎾h/day), while that of the conventional system was 2,803won/day(oil consumption 7.7ℓ/day) at the same heating mode.

An Uncertainty Assessment of Temperature and Precipitation over East Asia (동아시아 기온과 강수의 불확실성 평가)

  • Shin, Jin-Ho;Kim, Min-Ji;Lee, Hyo-Shin;Kwon, Won-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.299-303
    • /
    • 2008
  • In this study, an uncertainty assessment for surface air temperature(T2m) and precipitation(PCP) over East Asia is carried out. The data simulated by the intergovermental Panel on Climate Change (IPCC) Fourth Assessment Report (AR4) Atmosphere-Ocean coupled general circulation Model (AOGCM) are used to assess the uncertainty. Examination of the seasonal uncertainty of T2m and PCP variabilities shows that spring-summer cold bias and fall warm bias of T2m are found over both East Asia and the Korea peninsula. In contrast, distinctly summer dry bias and winter-spring wet bias of PCP over the Korea peninsula is found. To investigate the PCP seasonal variability over East Asia, the cyclostationary empirical orthogonal function(CSEOF) analysis is employed. The CSEOF analysis can extract physical modes (spatio-temporal patterns) and their undulation (PC time series) of PCP, showing the evolution of PCP. A comparison between spatio-temporal patterns of observed and modeled PCP anomalies shows that positive PCP anomalies located in northeastern China (north of Korea) of the multi-model ensemble(MME) cannot explain properly the contribution to summer monsoon rainfalls across Korea and Japan. The uncertainty of modeled PCP indicates that there is disagreement between observed and MME anomalies. The spatio-temporal deviation of the PCP is significantly associated with lower- and upper-level circulations. In particular, lower-level moisture transports from the warm pool of the western Pacific and corresponding moisture convergence significantly contribute to summer rainfalls. These lower- and upper-level circulations physically consistent with PCP give a insight of the reason why differences between modeled and observed PCP occur.

  • PDF

Effects of the El Niño on Tropospheric Ozone in a Simulation using a Climate-Chemistry Model (기후-대기화학모델이 모의한 엘니뇨가 대류권 오존에 미치는 영향)

  • Moon, Byung-Kwon;Yeh, Sang-Wook;Park, Rokjin J.;Song, Chang-Keun;Youn, Daeok
    • Journal of the Korean earth science society
    • /
    • v.34 no.7
    • /
    • pp.662-668
    • /
    • 2013
  • We examine the effects of El Ni$\tilde{n}$o on tropospheric ozone through the simulation of a Climate-Chemistry model for a 40-year period (1971-2010). The Empirical Orthogonal Function (EOF) analysis reveals that the tropospheric ozone concentration in the central-eastern Pacific decreases when the El Ni$\tilde{n}$o occurs, which is consistent with the observation. However, the increase of ozone over Indian Ocean-Indonesia regions is weak in the simulation compared to the observations. We analyze details of the 2006 El Ni$\tilde{n}$o event to understand the mechanism that caused the change of ozone due to El Ni$\tilde{n}$o. It is found that enhanced convection as well as higher water vapor followed by shortened lifetime has led to lower the tropospheric ozone. Downward motion induced by the changes of atmospheric circulation due to sea surface temperature forcing, together with the decrease of water vapor, has brought ozone produced in the upper troposphere over the Indian Ocean.

Quantitative Study of CO2 based on Satellite Image for Carbon Budget on Flux Tower Watersheds (플럭스 타워 설치 유역을 대상으로 탄소수지 분석을 위한 위성영상자료기반의 CO2 정량화 연구)

  • Jung, Chung Gil;Lee, Yong Gwan;Kim, Seong Joon;Jang, Cheol Hee
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.3
    • /
    • pp.109-120
    • /
    • 2015
  • Spatial heterogeneous characteristics of solar radiation energy from Climate Change gives rise to energy imbalance in the general ecological system including water resources. This study is to estimate the $CO_2$ flux of South Korea using Terra MODIS image and to assess the reliability of MODIS data from the ground measured $CO_2$ flux by eddy covariance flux tower data at 3 locations (two at mixed forest area and one at rice paddy area). The MODIS Gross Primary Productivity (GPP) product (MOD17A2), 8-day composite at 1-km spatial resolution was adopted for the spatial $CO_2$ flux generation. The MOD17A2 data by noise like cloud and snow in a day were tried to fill by Inverse Distance Weighted (IDW) method from valid pixels and the damping effect of MOD17A2 data were corrected by Quality Control (QC) flag. The MODIS $CO_2$ flux was estimated as the sum of GPP and Re (ecosystem respiration) by Lloyd and Taylor method (1994). The determination coefficient ($R^2$) between MODIS $CO_2$ and flux tower $CO_2$ for 3 years (2011~2013) showed 0.55 and 0.60 in 2 mixed forests and 0.56 in rice paddy respectively. The $CO_2$ flux generally fluctuated showing minus values during summer rainy season (from July to August) and maintaining plus values for other periods. The MODIS $CO_2$ flux can be a useful information for extensive area, for example, as a reliable indicator on ecological circulation system.

Distribution of Meiobenthic Communities in the Deep-sen Floor of Northeastern Pacific Seafloor along a Latitudinal Transect (북동 태평양 심해저에 서식하는 중형저서동물 군집의 위도별 분포 특성)

  • Min, Won-Gi;Kim, Dong-Sung;Kim, Woong-Seo
    • Ocean and Polar Research
    • /
    • v.26 no.2
    • /
    • pp.255-263
    • /
    • 2004
  • This study was conducted to investigate the community structure and distributional pattern of meiobenthos in the deep-sea bottom of the Clarion-Clipperton Fracture Zone of the northeastern Pacific during July 2003. The samples were collected using the multiple corer at 13 stations along the transects fiom $5^{\circ}N\;to\;17^{\circ}N$. The most abundant meiobenthos was nematodes and followed by sarcomastigophorans; these two taxa comprised more than 70% of the total abundance at all stations. For size distribution analyses showed that animals which fit into the sieve mesh size of 0.063mm were abundant. The maximum density of meiobenthos was $147inds./10cm^2$ at station located in $7^{\circ}N$, and the minimum density was $6 inds./10cm^2$ at station located in $14^{\circ}N$. More than 60% of meiobenthos were distributed at surface sediment layer within 1.0cm, and the peak abundance was found at $0{\sim}0.25cm$ layer. The latitudinal distribution pattern of meiobenthos in the study area seemed to be related with the primary productivity of the surface water that is also connected to the water circulation pattern of the Pacific Ocean near the Equator, diverging at latitude of $8^{\circ}N$ and conversing at $5^{\circ}N$.

A Study of Performance Characteristics on Hybrid Heat Pump System with Solar Energy as Heat Source (태양열이용 하이브리드 열펌프시스템의 성능특성에 관한 연구)

  • Park, Youn-Cheol;Kim, Ji-Young;Ko, Gwan-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2007
  • Interests on renewable energy are increased due to oil price and environmental problems aroused from the fossil energy usage. In this study, performances of a solar assisted hybrid heat pump system are analyzed by experimental method. The developed system could runs at two types of operating mode. When the storage temperature is higher than the set temperature, the stored hot water in storage tank is supplied to the load directly. On the other hand, when the storage temperature lower than the set temperature, the water inside of the storage tank is used as heat source of the heat pump. In this study, the system control temperature for the alternation of the operating mode is set to $40^{\circ}C$ of the storage tank outlet. As results, it is founded that the COP of the developed heat pump system shows between 3.0 and 3.5. It is resonable performance for the heating system with a renewable energy as secondary heat source. The solar collect used in this study could supplies heat to the storage tank at over 400 W/m2 solar intensity. If the irradiation is lower than the 400 W/m2, the circulation pump stored and it could not supply heat to the storage tank. It is found that the difference temperature between the outlet of the storage tank and collector is $3^{\circ}C$. Even though, the extended study should be conducted to get a optimum performance of the developed system with various operating condition and control strategies.

Quantification of future climate uncertainty over South Korea using eather generator and GCM

  • Tanveer, Muhammad Ejaz;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.154-154
    • /
    • 2018
  • To interpret the climate projections for the future as well as present, recognition of the consequences of the climate internal variability and quantification its uncertainty play a vital role. The Korean Peninsula belongs to the Far East Asian Monsoon region and its rainfall characteristics are very complex from time and space perspective. Its internal variability is expected to be large, but this variability has not been completely investigated to date especially using models of high temporal resolutions. Due to coarse spatial and temporal resolutions of General Circulation Models (GCM) projections, several studies adopted dynamic and statistical downscaling approaches to infer meterological forcing from climate change projections at local spatial scales and fine temporal resolutions. In this study, stochastic downscaling methodology was adopted to downscale daily GCM resolutions to hourly time scale using an hourly weather generator, the Advanced WEather GENerator (AWE-GEN). After extracting factors of change from the GCM realizations, these were applied to the climatic statistics inferred from historical observations to re-evaluate parameters of the weather generator. The re-parameterized generator yields hourly time series which can be considered to be representative of future climate conditions. Further, 30 ensemble members of hourly precipitation were generated for each selected station to quantify uncertainty. Spatial map was generated to visualize as separated zones formed through K-means cluster algorithm which region is more inconsistent as compared to the climatological norm or in which region the probability of occurrence of the extremes event is high. The results showed that the stations located near the coastal regions are more uncertain as compared to inland regions. Such information will be ultimately helpful for planning future adaptation and mitigation measures against extreme events.

  • PDF

Study on the Flow Characteristics around a Barge in Still Water (정수중 부선 주위의 유동 특성에 관한 연구)

  • Lee, Sang-Min;Jeong, Uh-Cheul;Kim, Hyun-Soo
    • Journal of Navigation and Port Research
    • /
    • v.34 no.6
    • /
    • pp.417-422
    • /
    • 2010
  • In this study, the resistance performances of barge are analyzed by model tests and computation using CFD to investigate the flow characteristics around a barge in still water. The model tests are carried out in infinite depth in Inha Technical College Circulation Tank to observe the resistance and the numerical simulations based on VOF(Volume of Fluid) method are performed to analyze the flow around the barge. We have selected two barge models to investigate the flow characteristics according to the different type of barges. The experiments are carried out with the models from 5kts to 10kts(designed speed 7kts) considering the effect of adverse and favorable current. The numerical simulations are performed to analyze the flow and resistance characteristics of barge in the full loaded condition with the target speed and compared with the experimental data to confirm the reliability of the numerical method. The result was that the difference of resistance with 25% occurred at low speed and EHP increased rapidly from 7kts.