• 제목/요약/키워드: circular section

검색결과 634건 처리시간 0.03초

극소형 원통컵의 드로잉성과 품질에 미치는 블랭크 홀딩력과 블랭크 직경의 영향 (Influence of Blankholding Force and Blank Diameter on the Drawability and Quality of Very Small Cylindrical Cups)

  • 이기성;김종봉;정완진;김종호
    • 소성∙가공
    • /
    • 제23권8호
    • /
    • pp.489-494
    • /
    • 2014
  • Micro forming is an appropriate process to manufacture very small metal parts which can be employed in the field of electronic devices or electrically controlled mechanical systems. The purpose of the current study was to investigate the influences of both blankholding force and blank diameter for the deep drawing of very small cups. It is essential to control the blankholding force because improper force can result in defects such as wrinkles in the flange or cracks in the corner of the drawn cups. In the current study blankholding force was controlled by springs connected to the blankholder of a press die. Exchangeable bushing dies with various die-corner radii were also used. To obtain the limit drawing ratio for each working condition several sizes of circular specimens were prepared using blanking tools. Beryllium copper(C1720) alloy sheet of $50{\mu}m$ thickness was chosen for the experiments. The maximum limit drawing ratio of 2.1 was achieved experimentally for the conditions of the blankholder force(BHF)=5.3kgf and Rd=0.3mm. Both thickness and hardness along the central section of drawn cups were measured and compared for different drawing conditions. It was found that the deviation of measured data in the thickness and hardness distribution increases with increasing blankholder force and blank diameter.

쉴드 TBM터널 상부 지반 연약대 전기탐사 (Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling)

  • 정현기;박철환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

단면의 변의 수가 초고층 건물의 공력특성에 미치는 영향 (Effects of Number of Sides on Aerodynamic Characteristics of Super-Tall Buildings)

  • 김용철;반디 에스와라 쿠마;유키오 타무라;요시다 아키히또;윤성원
    • 한국공간구조학회논문집
    • /
    • 제13권3호
    • /
    • pp.83-90
    • /
    • 2013
  • A series of wind tunnel tests were conducted on 7 super-tall buildings with various polygon cross-sections, including triangle, square, pentagon, hexagon, octagon, dodecagon, and circular. The primary purpose of the present study is to investigate the effect of increasing number of sides on aerodynamic characteristics for super-tall buildings. Wind tunnel tests were conducted under the turbulent boundary layers whose power-law exponent is 0.27. Fluctuating wind pressures from more than 200 pressure taps were recorded simultaneously, and time series of overturning moments were calculated considering tributary area of each pressure tap. The results show that the overturning moment coefficients and the spectral values decrease with increasing number of sides, and the largest mean and fluctuating overturning moments were found for the triangular super-tall building, and the largest spectral values were found for the square super-tall building. The analysis should be conducted more in detail, but currently it can be roughly said that there seems to be a little differences in the aerodynamic characteristics for the super-tall buildings whose number of sides is larger than 5 or 6.

2 MW급 풍력터빈 블레이드 설계 및 단방향 유체-구조연성해석 (Design of a 2MW Blade for Wind Turbine and Uni-Directional Fluid Structure Interaction Simulation)

  • 김범석;이강수;김만응
    • 대한기계학회논문집B
    • /
    • 제33권12호
    • /
    • pp.1007-1013
    • /
    • 2009
  • The purposes of this study are to evaluate the power performance through CFD analysis and structural integrity through uni-directional FSI analysis in aerodynamic design and structure design of wind turbine blade. The blade was designed to generate the power of 2MW under the rated wind speed of 11 m/s, consisting of NACA 6 series, DU series and FFA series airfoil. The inside section of the blade was designed into D-spar structure and circular stiffener was placed to reinforce the structural strength in the part of hub. CFD analysis with the application of transitional turbulence model was performed to evaluate the power performance of blade according to the change of TSR and 2.024MW resulted under the condition of rated wind speed. TSR of 9 produced the maximum power coefficient and in this case, Cp was 0.494. This study applied uni-directional FSI analysis for more precise evaluation of structural integrity of blade, and the results of fiber failure, inter fiber failure and eigenvalue buckling analysis were evaluated, respectively. For the evaluation, Puck's failure criteria was applied and the result showed that fiber failure and inter fiber failure did not occur under every possible condition of the analysis. As a result, power performance and structural integrity of 2 MW blade designed in this study turned out to satisfy the initial design goals.

노트북 PC CPU 냉각용 소형 히트파이프 Packaging 연구 (Application of Miniature Heat Pipe for Notebook PC Cooling)

  • 문석환;황건;최태구
    • 대한기계학회논문집B
    • /
    • 제25권6호
    • /
    • pp.799-803
    • /
    • 2001
  • Miniature heat pipe(MHP) with woven-wired wick was used to cool the CPU of a notebook PC. The pipe with circular cross-section was pressed and bent for packaging the MHP into a notebook PC with very limited compact packaging space. A cross-sectional area of the pipe is reduced about 30% as the MHP with 4mm diameter is pressed to 2mm thickness. In the present study a performance test has been performed in order to review varying of operating performance according to pressed thickness variation and heat dissipation capacity of MHP cooling module that is packaged on a notebook PC. New wick type was considered for overcoming low heat transfer limit when MHP is pressed to thin-plate. The limiting thickness or pressing is shown to be within the range of 2mm∼2.5mm through the performance test with varying the pressing thickness. When the wall thickness of 0.4mm is reduced to 0.25mm for minimizing conductive thermal resistance through the wall of heat pipe, heat transfer limit and thermal resistance of MHP were improved about 10%. In the meantime, it is shown that the thermal resistance and heat transfer limit for the MHP with central wick type are higher than those of MHP with existing wick types. The results of performance test for MHP cooling modules with woven-wired wick to cool a notebook PC shows the stability as cooling system since T(sub)j(Temperature of Processor Junction) satisfy a demand condition of 0∼100$\^{C}$ under 11.5W of CPU heat.

원형 세장 실린더의 와 유기 진동;수조 실험 결과 (Vortex induced vibration of circular pipes; the experiment in a water tank)

  • 김양한;박주배;홍섭;최윤락
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.478-483
    • /
    • 2001
  • We experimentally attempted to understand the vibration characteristics of a flexible pipe excited by vortex shedding. This has been extensively studied in the past decades (For example, see [2-9]). However, there are still areas that need more study. One of them is to study the relation between spatial characteristics of a flow induced vibrating pipe, such as its length, the distribution of wave number, and frequency responses. A non-linear mechanism between the responses of in-line and cross-flow directions is also an area of interests, if the pipe is relatively long so that structural modal density is reasonably high. In order to investigate such areas, two kinds of instrumented pipe were designed. The instrumented pipes, of which the lengths are equally 6m, are wound with rubber and silicon tape in different ways, having different vortex shedding conditions. One has uniform cross-section of diameter of 26. 7mm, and the other has equally spaced by 4 sub-sections, which are composed of different diameters of 75.9, 61.1, 45.6 and 26.7mm. Both pipes are towed in a water tank (200m ${\times}$ 16m ${\times}$ 7m) so that they experienced different vortex shedding excitations. The towing pipe experiments exhibit several valuable features. One of them is that the natural frequencies and their corresponding strain mode shapes dominate the strain response of the uniform pipe. However, for those of non-uniform pipe, the responses are more likely local and many modes participate in it.

  • PDF

Web crippling strength of cold-formed stainless steel lipped channel-sections with web openings subjected to interior-one-flange loading condition

  • Yousefi, Amir M.;Lim, James B.P.;Uzzaman, Asraf;Lian, Ying;Clifton, G. Charles;Young, Ben
    • Steel and Composite Structures
    • /
    • 제21권3호
    • /
    • pp.629-659
    • /
    • 2016
  • In cold-formed stainless steel lipped channel-sections, web openings are becoming increasingly popular. Such openings, however, result in the sections becoming more susceptible to web crippling, especially under concentrated loads applied near the web opening. This paper presents the results of a finite element parametric study into the effect of circular web openings on the web crippling strength of cold-formed stainless steel lipped channel-sections for the interior-one-flange (IOF) loading condition. This involves a bearing load applied to the top flange of a length of member, away from the end supports. The cases of web openings located centred beneath the bearing load (i.e. beneath the bearing plate delivering the load) and offset to the bearing plate, are considered. Three grades of stainless steel are considered: duplex EN1.4462, austenitic EN1.4404 and ferretic EN1.4003. In total, 2218 finite element models were analyzed. From the results of the parametric study, strength reduction factors for load bearing capacity are determined, where these reduction factors are applied to the bearing capacity calculated for a web without openings, to take account the influence of the web openings. The strength reduction factors are first compared to equations recently proposed for cold-formed carbon steel lipped channel-sections. It is shown that for the case of the duplex grade, the strength reduction factor equations for cold-formed carbon steel are conservative but only by 2%. However, for the cases of the austentic and ferritic grades, the cold-formed carbon steel equations are around 9% conservative. New strength reduction factor equations are proposed for all three stainless steel grades.

지반 물성치의 공간적 분포에 따른 터널 변위 특성 분석 (Effect of Spatial Distribution of Geotechnical Parameters on Tunnel Deformation)

  • 송기일;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제8권3호
    • /
    • pp.249-257
    • /
    • 2006
  • 지반 설계 인자는 공간적으로 분포하는 특성이 있으며, 이는 터널의 설계와 시공과정 뿐만 아니라 장기 거동에 큰 영향을 미친다. 그러나 일반적으로 터널의 수치해석을 위한 설계 지반 인자는 대상 영역을 대표하는 값 또는 대상 영역의 광역적 평균값 등이 적용되고 있다. 특히, 지하공간의 크기가 증가할수록 설계 지반 인자의 불확실성 및 공간적 분포 또한 증가한다. 결국 이러한 불확실성과 공간적 분포 특성의 확대는 해석의 정확성 및 신뢰성 저하를 초래하게 된다. 따라서, 대형 터널의 구조적 안정성을 확보하기위해 지반 물성치들의 공간적인 분포에 대한 정량적인 조사가 설계시 포함되어야 한다. 본 연구에서는 지반 물성치 및 구조적 설계 인자의 공간적 분포가 터널의 변위에 미칠 수 있는 영향을 분석하였다. 여러 COV(Coefficient of Variation)에 따라 정규분포하는 지반 물성치의 공간적 특성이 이상화된 원형 터널의 변위에 미치는 영향에 대한 분석과, NATM(New Austrian Tunneling Method) 터널에서 숏크리트의 강도의 공간적 분포가 터널 변위에 미치는 영향을 분석하였다. 공간적 분포의 COV가 증가할수록 터널 주변 발생하는 변위량도 증가하는 것으로 나타났으며, 분석 결과 이들은 지반 물성치에 따라 고유한 계수를 갖는 삼차방정식으로 표현된다.

원통형 임피던스 튜브 내 미세천공 탄성 판의 흡음 (Sound absorption of micro-perforated elastic plates in a cylindrical impedance tube)

  • 김현실;김봉기;김상렬;이성현;마평식
    • 한국음향학회지
    • /
    • 제37권4호
    • /
    • pp.181-187
    • /
    • 2018
  • 본 논문은 원형 단면 임피던스 튜브내에 고정된 미세천공 탄성판의 흡음을 해석적으로 구하는 방법을 다루었다. 판의 진동과 덕트 내부 음장을 모드 함수의 무한 급수의 합으로 전개하였는데 반경방향으로는 Bessel 함수를 포함한다. 평면파 가정하에서 저주파수 대역의 근사식을 판의 처음 몇 개의 모드만 고려하여 흡음율을 유도하였으며 등가 임피던스를 갖는 단일 표면의 형태로 제시하였다. 본 논문에서 제안한 공식과 FEM(Finite Element Method)을 이용한 결과는 잘 일치 하였는데 탄성의 효과는 판의 고유진동수에 해당하는 골 또는 피크의 형태로 나타난다. 천공율이 매우 작으면 진동의 영향이 지배적이나 천공율이 어느 한계이상 되면 박판의 탄성거동은 매우 작게 나타나고 강체 MPP(Micro-Perforated Plate)의 흡음 특성이 지배적이 된다.

인종 모발의 형태학적 차이에 관한 전자현미경적 연구 (Electron Microscopic Studies on the Morphological Differences of Ethnic Hair)

  • 이귀영;장병수
    • Applied Microscopy
    • /
    • 제38권3호
    • /
    • pp.265-273
    • /
    • 2008
  • 본 연구는 국내에 거주하는 흑인종, 백인종, 황인종 여성의 모발을 채취하여 전자현미경으로 모발의 미세구조적 차이를 규명하였다. 흑인종 모발의 횡단면은 납작한 타원형의 형태를 하고 있었으며 황인종과 백인종 모발은 각각 원형과 타원형의 형태를 하고 있었다. 흑인종 모발은 두께가 $90{\sim}115{\mu}m$로 굵기가 일정하지 않았다. 황인종모발은 두께가 $100{\mu}m$이었으며 백인종 모발은 두께가 $80{\mu}m$로 측정되었다. 모발의 두께는 황인종 모발이 백인종 모발보다 크게 나타났다. 흑인종 모발은 황인종과 백인종 모발 보다 큐티클층이 많이 손상되어 있었다. 특히 큐티클세포의 내큐티클에는 많은 구멍들이 형성되어 있어서 쉽게 부서지는 특성이 나타났다. 백인종 모발의 피질에 있는 페오멜라닌은 내부에 동심원상의 나선구조를 하고 있었다.