• 제목/요약/키워드: circular external fixator

검색결과 3건 처리시간 0.021초

Minimally Invasive Plate Osteosynthesis of Radius-Ulna Fracture using Circular External Fixator in a Dog

  • Kwon, Yong-hwan;Kang, Jin-su;Kim, Young-ung;Cho, Hyoung-sun;Lee, Ki-chang;Kim, Nam-soo;Kim, Min-su
    • 한국임상수의학회지
    • /
    • 제34권1호
    • /
    • pp.47-49
    • /
    • 2017
  • Fracture stabilization techniques continue to evolve and provide approaches that minimize the iatrogenic trauma associated with surgical procedures. Minimally invasive plate osteosynthesis (MIPO) is a recently described method of biological internal fixation performed by introducing a bone plate via small insertional incisions that are remote to the fracture site. Indirect reduction techniques can generally be utilized when performing MIPO. In this case report, we describe MIPO of a radius-ulna fracture by indirect reduction using circular external fixation for alignment and distraction in a dog.

C형 경골천정 골절에 대한 일리자로브 외고정술 (ILIZAROV FIXATION FOR THE TYPE C TIBIAL PLAFOND FRACTURES)

  • 조헌오;곽경덕;조성도;김병용;오장호
    • 대한족부족관절학회지
    • /
    • 제1권1호
    • /
    • pp.51-58
    • /
    • 1997
  • The purpose of this study is to evalute the efficacy af the Ilizarov external fixation for the surgical treatment. of the tibial plafond fractures. We reviewed retrospectively fourteen cases of tibial plafond fractures with moderate to severe soft. tissue damage, which were fixed with Ilizarov external fixator. Using the AO Muler classification, there were four Type C1 fractures, six Type C2 and four Type C3. In most, of the cases, the ankles were operated on with other associated fractures within a few days after injury. We reduced the fracture indirectly by soft issue taxis and fixed externally across the ankle joint. using the circular external fixator with tensioned wires and ankle hinge. In cases of inadequate closed reduction, we applied limited open reduction and internal fixation. Range of motion exercise began immediately. Postoperative follow-up averaged fourteen months (ranges, 8-30 months). Overall clinical results rated good or excellent in 7 cases, fair in 4 and poor in 3. There were three cases of pin tract infection which were resolved with short-term antibiotics and local care; one delayed wound closure in a patient. whose fracture was associated with Type III open wound; one wound slough in a patient associated with Type II open wound, which was closed later by skin graft; and one osteoarthritis. From this review, we concluded that cross-ankle circular external fixation with tensioned wires with or without. limited open reduction is a reasonable alternative for the treatment of the tibial plafond fractures with severe soft tissue damage.

  • PDF

개에서 원형외고정장치를 이용한 관절주위 골절의 안정화 (Stabilization of Short Juxta-articular Fractures Using a Circular External Skeletal Fixator System in Dogs)

  • 정혜련;김주호;차재관;설재원;김민수;이해범
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.523-526
    • /
    • 2014
  • 세마리의 개가 골절을 주증으로 내원하였다. 증례 1(1.8 kg의 5개월령 암컷 몰티즈)과 증례 2(3.0 kg의 6개월령 암컷 푸들)는 좌측 후지의 체중부중을 하지 않는 파행을, 증례 3(3.3 kg의 나이를 알 수 없는 암컷 잡종견)은 좌측 전지의 체중부중을 하지 않는 파행을 보였다. 정형외과 검사시 손상받은 부위의 통증, 염발음, 촉진상의 불안정성과 광범위한 연부조직 부종을 보였으며 신경학적 이상소견은 관찰되지 않았다. 방사선 검사상 증례 1와 2에서 좌측 근위 경골 골간단과 비골의 골절이, 증례 3에서는 좌측 근위 요골 골간단과 척골의 골절이 관찰되었다. 모든 증례는 골절편이 짧은 관절주위 폐쇄형 골절이었다. 술 중에는 투시장치를 이용해 2개 또는 3개의 원형고정장치의 적절한 위치에 삽입하였다. 술 후 방사선 사진에서 골절부위의 적절한 배열과 위치를 확인하였다. 방사선학적으로 5주에서 14주 사이에서 골유합이 확인되었고 임플란트의 고정 실패나 핀 주변 감염은 나타나지 않았다. 기능상 결과는 모든 증례에서 매우 좋은 것으로 나타났다. 따라서, 원형외고정장치는 뼈판이나 외고정장치를 사용할 수 없는 짧은 골절편을 가진 관절주의의 골절정복에 성공적으로 이용할 수 있을 거라 사료된다.