• Title/Summary/Keyword: circular

Search Result 7,455, Processing Time 0.036 seconds

The Design of Smart-phone Application Design for Intelligent Personalized Service in Exhibition Space (전시 공간에서 지능형 개인화 서비스를 위한 스마트 폰 어플리케이션 설계)

  • Cho, Young-Hee;Choi, Ae-Kwon
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • The exhibition industry, as technology-intensive, eco-friendly industry, contributes to regional and national development and enhancement of its image as well, if it joins cultural and tourist industry. Therefore, We need to revitalize the exhibition industry, as actively holding an exhibition event. However, to attract a number of exhibition audience, the work of enhancing audience satisfaction and awareness of value for participation should be prioritized after improving quality of service within exhibition hall. As one way to enhance the quality of service, it is thought that the way providing personalized service geared toward each audience is needed. that is, if audience avoids the complexity in exhibition space and it affords them service to enable effective time and space management, it will improve the satisfaction. All such personalized service affordable lets the audience's preference on the basis of each audience profile registered in advance online grasp. and Based on this information, it is provided with exhibition-related information suited their purpose that is the booth for the interesting audience, the shortest path to go to the booth and event via audience's smart phone. and it collects audience's reaction information, such as visiting the booth, participating the event through offered the information in this way and location information for the flow of movement, the present position so that it makes revision of existing each audience profile. After correcting the information, it extracts the individual's preference. hereunder, it provides recommend booth and event information. in other words, it provides optimal information for individual by amendment based on reaction information about recommending information built on basic profile. It provides personalized service dynamic and interactive with audience. This paper will be able to provide the most suitable information for each audience through circular and interactive structure and designed smart-phone application supportable for updating dynamic and interactive personalized service that is able to afford surrounding information in real time, as locating movement position through sensing. The proposed application collects user‘s context information and carrys information gathering function collecting the reaction about searched or provided information via sensing. and it also carrys information gathering function providing needed data for user in exhibition hall. In other words, it offers information about recommend booth of position foundation for user, location-based services of recommend booth and involves service providing detailed information for inside exhibition by using service of augmented reality, the map of whole exhibition as well. and it is also provided with SNS service that is able to keep information exchange besides intimacy. To provide this service, application is consisted of several module. first of all, it includes UNS identity module for sensing, and contain sensor information gathering module handling and collecting the perceived information through this module. Sensor information gathered like this transmits the information gathering server. and there is exhibition information interfacing with user and this module transmits to interesting information collection module through user's reaction besides interface. Interesting information collection module transmits collected information and If valid information out of the information gathering server that brings together sensing information and interesting information is sent to recommend server, the recommend server makes recommend information through inference with gathered valid information. If this server transmit by exhibition information process, exhibition information process module is provided with user by interface. Through this system it raises the dynamic, intelligent personalized service for user.

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF

Characteristics of Pinewood Nematode Trapping by Nematophagous Arthrobotrys spp. (선충포획성 Arthrobotrys속균에 의한 소나무재선충 포획 특성)

  • Lee, Gak-Jung;Koo, Chang-Duck;Sung, Joo-Han
    • The Korean Journal of Mycology
    • /
    • v.36 no.2
    • /
    • pp.153-162
    • /
    • 2008
  • Pinewood nematode (PWN) trapping by nematophagous fungi, Arthrobotrys conoides, A. dactyloides and A. oligospora and the fungal growth were characterized. The three Arthrobotrys species each was inoculated into the PWN cultured on Botrytis cinera fungal colony on potato dextrose agar (PDA). The effects of temperature, pH, PWN inoculation density and nutrients on the growth of the three Arthrobotrys spp were measured. A. conoides grew fast, 13.9 mm/day while A. dactyloides grew slow, 3 mm/day. PDA medium was the best for the fungal growth at $25^{\circ}C$ and pH 4.5. The Arthrobotrys spp growth was stimulated by 500 nematodes inoculation but not by 1000 inoculation. A. dactyloides did not grow below pH 4.5 and at high PWN density. A. conoides and A oligospora formed trapping organs with thick constricting hyphal network only when PWN present, while A. dactyloides formed the organ with circular hyphae constitutively. A. conoides formed trapping organs faster than A. oligospora did. The nematode trapping hyphae of the fungi penetrated into PNW inside to form many tiny infection bulbs and to digest the nematode. However, A. dactyloides formed a few trapping organs but no trapping was observed. Infection rate of PWN was 95% by A. conoides, 80% by A. oligospora and 92% by the combination inoculation of A. conoides and A. oligospora. In contrast A. dactyloides increased PWN density without infecton. There was no interaction effect in any combination inoculation of the three Arthrobotrys spp. A. conoides enhanced PWN infection rate by rapid hyphal growth and early trapping, while A. oligospora did it by increasing hyphal density. In conclusion A. conoides is the most effective in both hyphal growth and infection, and thus these characteristics can be utilized as a biological control of PWN.

Long Term Effects of Lamivudine and Adefovir dipivoxil in Chronic Hepatitis B Patients on the Development of Hepatocellular Carcinoma (만성 B형간질환에서 HBV백신 및 항바이러스치료가 간세포암종 발생에 미치는 효과)

  • Lee, Heon-Ju
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.1
    • /
    • pp.1-18
    • /
    • 2008
  • Although Lamivudine and adefovir dipivoxil are efficacious drugs for preventing hepatocellular carcinoma (HCC) in chronic hepatitis B patients, their efficacy is far from completely satisfactory. The risk of liver cirrhosis and HCC begins to increase at an HBV DNA level of $10^4$ copies/ml. Even with latent or past HBV infection, episomal covalently closed circular DNA(cccDNA) plays a key rolein the persistence, relapse and resistance of HBV in its natural course or during therapy. The annual incidence of HCC in YUMC is 1.8% and 4.7% patients/year in the antiviral treatment and control groups, respectively. The ability to achieve a high rate of sustained HBV suppression with low risk of drug resistance is the ultimate goal in the treatment of chronic HBV infection. The efficacy of universal immunization with striking reductions in the prevalence of HBV in localized countries needs to be spread worldwide. With hepatitis B immunization and effective antiviral therapy, global control of HBV infection and HBV-related complications, including HCC, are possible by the end of the first half of the $21^{st}$ century.

  • PDF

Evaluation of Construction Operation and Design Properties of CLSM for Corrugated Pipe in Underground (파형강관을 이용한 지하매설물용 뒤채움재 설계 및 시공성 평가)

  • Lee Kwan-Ho;Park Jae-Heon
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.63-74
    • /
    • 2006
  • During the construction of circular underground pipe, the non-proper compaction along the pipe and the decrease of compaction efficiency have been the main problems to induce the failure of underground pipe or facility. The use of CLSM (controlled low strength materials) should be one of the possible applications to overcome those problems. In this research, the full-scaled field test and the numeric analysis using PENTAGON-3D FEM program were carried out for three different cases on the change of backfill materials, including the common sand, the soil from construction site, and the CLSM. From the full-scaled test in field, the use of in-situ CLSM as backfill materials reduced the vertical and lateral deformation of the pipe, as well as the deformation of the ground surface. The main reason for reducing the deformation would be the characteristics of the CLSM, especially self-leveling and self-hardening properties. The measured earth pressure at the surround of the corrugated pipe using the CLSM backfills was the smaller than the other cases, and the absolute value was almost zero. Judging from the full-scaled field test and FEM analysis, the use of CLSM as backfill materials should be one of the best choices reducing the failure of the underground pipes.

  • PDF

Fabrication of Backscatter Electron Cones for Radiation Therapy (산란전자선을 이용한 강내측방조사기구의 제작과 특성)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2001
  • Purpose : Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface dose is desired. Methods and Materials : Backscatter electrons are produced from the primary electron beams from the linear accelerators. The design consists of a cylindrical cone that has a thick circular plate of high atomic number medium (Pb or Cu) attached to the distal end, and the plate can be adjusted the reflected angle. Primary electrons strike the metal plate perpendicularly and produce backscatter electrons that reflect through the lateral hole for treatment. Using film and a parallel plate ion chamber, backscatter electron dose characteristics are measured. Results : The depth dose characteristic of the backscatter electron is very similar to that of the hard x-ray beam that is commonly used for the intracavitary and superficial lesions. The basckscatter electron energy is nearly constant and effectively about 1.5 MeV from the clinical megavoltage beams. The backscatter electron dose rate of $35\~85\;cGy/min$ could be achieved from modern accelerators without any modification. and the depth in water of $50\%$ depth dose from backscatter electron located at 6mm for $45^{\circ}$ angled lead scatter. The beam flatness is dependent on the slit size and the depth of treatment, but is satisfactory to treat small lesions. Conclusions : The measured data for backscatter electron energy, depth dose flatness dose rate and absolute dose indicates that the backscatter electrons are suitable for clinical use.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields (선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션)

  • Jeong Dong Hyeok;Lee Jeong Ok;Kang Jeong Ku;Kim Soo Kon;Kim Seung Kon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • Purpose : In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations for the small fields. Materials and Methods : The small fields of 1.0, 2.0 and 3.0 cm in diameter were used in this study. Percentage depth dose (PDD) and beam Profiles of those fields were measured and calculated. A small semiconductor detector, water phantoms, and a remote control system were used for the measurement Monte Carlo simulations were Performed using the EGS4 code with the input data prepared for the energy distribution of 6 MV X-rays, beam divergence, circular fields and the geometry of the water phantoms. Results : In the case of PDD values, the calculated values were lower than the measured values for all fields and depths, with the differences being 0.3 to 5.7% at the depths of 20 to 20.0 cm and 0.0 to 8.9% at the surface regions. As a result of the analysis of beam profiles for all field sizes at a depth of loom in water phantom, the measured 90% dose widths were in good agreement with the calculated values, however, the calculated Penumbra radii were 0.1 cm shorter than measured values. Conclusion : The measured PDDs and beam profiles agreement with the Monte Carlo calculations approximately. However, it is different when it comes to calculations in the area of phantom surface and penumbra because the Monte Carlo calculations were performed under the simplified geometries. Therefore, we have to study how to include the actual geometries and more precise data for the field area in Monte Carlo calculations. The Monte Carlo calculations will be used as a useful tool for the very complicated conditions in measurement and verification.

  • PDF

The Evaluation of Images with Various Filters in I-131 SPECT/CT (I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용)

  • Kim, Ha Gyun;Kim, Soo Mee;Woo, Jae Ryong;Oh, So Won;Lee, Jae Sung;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

  • PDF

Cenozoic Brittle Stars (Ophiuroidea) from the Hagjeon Formation and the Duho Formation, Pohang Basin, Korea (제 3기 포항분지의 학전층과 두호층에서 산출된 거미불가사리 화석)

  • Seong, Mi-Na;Kong, Dal-Yong;Lee, Bong-Jin;Lee, Seong-Joo
    • Economic and Environmental Geology
    • /
    • v.42 no.4
    • /
    • pp.367-376
    • /
    • 2009
  • Forty specimens of fossil ophiuroids were collected from two formations of the Cenozoic marine deposits, Duho Formation and Hagjeon Formation, Pohang Basin, Korea. A few specimens were three-dimensionally preserved: most of them were remained flattened and articulated. Although a gross morphology is well preserved in some specimens, the details such as disk shape and plates which is the most important diagnostic features were not observed. Most of the arms are disarticulated, and thus arm vertebra, arm spines and/or arm plates are separately preserved. Only an oral side is recognized in an attached specimens because crossing arms into disk are clearly visible. It is, thus almost impossible to identify Korean ophiuroid fossils as a species level or even a genus level. The fossils were classified into 3 groups by gross morphology of disk and arm, and architecture of vertebra. The most abundant fossils (32 specimens), were found only in the Hagjeon Formation. The majority of specimens are partially disarticulated, having only proximal and median portions of their arms preserved. Arm plates are disarticulated from arm vertebra: most of them show structure of arm vertebra. It has long and well-preserved arm spines, and large tentacle pore. Some specimens (4 specimens) from the Duho Formation is characterized by short and conical arm spines, and well-developed arm plates. Lateral arm plates are small in compared to dorsal and ventral arm plates. The others (4 specimens) is poor in preservation state showing circular oral disk and relatively short sinuous arms. No arm plates are either identified.