• Title/Summary/Keyword: chlorobenzenes(CBs)

Search Result 7, Processing Time 0.023 seconds

Distribution of Certain Chlorobenzene Isomers in Marine Sediments from the Southeastern Coastal Areas of Korea

  • Moon Hyo-Bang;Choi Hee-Gu;Kim Sang-Soo;Lee Pil-Yong;Kim Hak-Gyoon;Ok Gon
    • Fisheries and Aquatic Sciences
    • /
    • v.4 no.2
    • /
    • pp.58-64
    • /
    • 2001
  • Eight chlorobenzenes (out of a total of 12 in the congener series) were measured in the sediments from 21 stations in the southeastern coastal areas of Korea. The levels of total chlorobenzene isomers varied between 2.08 and 12.45 ng/g dry weight. The highest contents of total chlorobenzenes (CBs) were found in the sediments from Pohang coast. Trichloro­benzenes (the sum of 1,3,5-, 1,2,4- and 1,2,3-trichlorobenzene) were dominant classes among four congeners, whereas tetrachlorobenzenes (the sum of 1,2,3,5-, 1,2,4,5- and 1,2,3,4-tetra­chlorobenzene) and pentachlorobenzene were low levels. The contributions of total CBs showed similar patterns for all stations with positive significant correlation within CBs species. It means that CBs contamination in the southeastern coasts of Korea came from the similar source.

  • PDF

The Content of Chlorobenzenes and Chlorophenols and Their Isomer in MSWI Fly Ash (소각잔사 중의 클로로벤젠과 클로로페놀의 함량 및 이성체 분포특성)

  • Lee, U-Geun;Sim, Yeong-Suk;Kim, Jin-Beom
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.209-218
    • /
    • 1998
  • Chlorobenzenes (CBs) and chlorophenols (CPs) in fly ashy discharged from several municipal solid waste incinerators (MSWI) were investigated in terms of total content and isomer distribution. The content of CBs and CPs was highest in the fly ash from S incinerator, which were 1040.7ng CB/g-fly ash and 1156.4 ng CP/g-fly ash. According to the experimental results, while all samples contained a large amount of the higher chlorinated CBs, was almost constant regardless of season. The quantities of CBs and CPs depended closely on the chemical composition of MSW. while the isomer distribution of CBs and CPs was constant throughout all the year round.

  • PDF

Distribution of Certain Chlorobenzenes in Seawater from Youngil Bay, Korea

  • Moon, Hyo-Bang;Park, Hee-Gu;Kim, Sang-Soo;Jeong, Seung-Ryul;Lee, Pil-Yong
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.107-111
    • /
    • 2001
  • Surface seawater was sampled from 20 stations in Youngil Bay, Korea in November 2000. The samples were analyzed for eight chlorobenzenes(CBs) out of a total of 12 in the congener series using a gas chromatography coupled to a mass spectrometer detector(GC/MSD). The total CB levels varied from 1.3 to 6.1 ng/L with a mean of 4.0 ng/L. Trichlorobenzene groups (sum of 1,3,5-, 1,2,4-, and 1,2,3-trichlorobenzene) were the predominant class among the four congener groups, while tetrachlorobenzenes(sum of 1,2,3,5-, 1,2,4,5-, and 1,2,3,4- tetrachlorobenzene) and pentachlorobenzene showed a low presence. The total CB levels exhibited similar patterns for all the stations. A significant positive correlation was observed between the individual CB compounds in the particulate samples, while the dissolved samples revealed a strong correlation between the heavier molecular weight CBs.

  • PDF

Formation Characteristics of Chlorobenzenes and Chlorophenols from TCE (TCE (trichloroethylene)으로부터 클로로벤젠과 클로로페놀의 생성특성)

  • 김은미;심영숙;이우근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.2
    • /
    • pp.149-159
    • /
    • 2002
  • The objective of this study was to evaluate the formation characteristics of CBs and CPs from TCE, aliphatic compound. The experiment was carried out in a fixed reactor during 30 min under the oxidation condition at the range of temperature, 300~$700^{\circ}C$. MSWI fly ash was used as catalyst in this study. Total amount of CBs formed greater magnitude than that of CPs overall range of reaction temperature. It is proposed that the formation of CPs was caused from hydroxylation of CBs. According to increasing temperature to $600^{\circ}C$, the yield of CBs and CPs increased but significantly decreased at $700^{\circ}C$. It is suggested that decomposition rate was faster than formation rate at the high temperature. In the homologue distribution of CBs, DCBs were major products at 30$0^{\circ}C$ and the amount of higher chlorinated compound increased to $600^{\circ}C$. Because they were formed by chlorination of lower chlorinated compounds. In case of CPs, the amount of DCPs was 90% of total amounts in both thermal formation and catalytic reaction. On the other hand it was clearly observed that the chlorination rate in catalytic reaction was higher than in thermal formation with TCE only.

Distribution of certain chlorobenzene isomers in marine sediments from the southeastern coastal areas of Korea

  • Moon, Hyo-Bang;Park, Hee-Gu;Kim, Sang-Soo;Lee, Pil-Yong;Kim, Hak-Gyoon;Gon Ok
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.05a
    • /
    • pp.267-268
    • /
    • 2001
  • Chlorobenzenes (CBs) are ubiquitous hydrophobic chlorinated organic compounds in the environment. These compounds are used as de-ordants, solvents and pesticides, as well as byproducts of agro- or petro-chemical related manufacturing processes, such as PCBs and pentachlorophenol, or of biodegradation of lindane (Newhook and Meek, 1994). Unlike some organochlorine (OC) compounds, including polychlorinated biphenyls (PCBs) and various pesticides, CBs are not banned from production or use in any country. (omitted)

  • PDF

Emission Character of PCDDs/PCDFs and Precusors in the Flue Gas of the MWSI(I) (도시쓰레기 소각로 배출가스 중 다이옥신류 및 전구물질의 배출특성(I))

  • Shin, S.K.;Chung, Y.H.;Kim, S.C.;Jang, S.K.;Lee, J.I.;Lee, W.S.;Lee, J.B.;Lee, D.H.
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.61-67
    • /
    • 1999
  • Two of municipal waste incinerators were selected as surveying facilities to research on the emission of dioxin and precusors. The sampling of flue gas and analysis was performed in the selected facilities. From the result, the emission patterns of dioxin and precusors, their relatership were examined. The toxic equivalency quantity(TEQ) of dioxin concentration was evaluated in two municipal waste incinerators. The 76.24% and 60.84% of total dioxin concentration in A and B incinerator were made up of the penta-, hexa- and hepta-chlorinated dibenzo-p-dioxin, respectively. Therefore, to reduce the dioxins in flue gas have to control the formation of furans. The chlorobenzenes and chlorophenols were analyzed in two incinerators. The 1,2,4,5-tetrachlorobenzene, penta-, and hexachlorobenzene are discharged and 2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol and pentachlorophenol are discharged mainly in A and B municipal waste incinerators.

  • PDF

Emission Character of Dioxins and Precursors in the Control Devices of the MSWI (II) (도시쓰레기 소각로 방지시설 중 다이옥신류 및 전구물질의 배출특성(II))

  • Shin, S.K.;Chung, Y.H.;Lee, W.S.
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.68-74
    • /
    • 1999
  • The Concentrations of PCDDs/PCDFs and their precusors(chlorophenols, chlorobenzenes, PCB) were analyzed from the dioxin control device such as EP and SCR to know the emission patterns of these compounds and find the dioxin index compounds. The dioxin concentration increased 7 times in outlet part than inlet part of EP and the concentration of CBs, CPs and PCBs also were increased through this control device. These phenomia may be related to the operating temperature of Electroprecipitator(EP), which the operating temperature is near the $300^{\circ}C$, the method of the decreasing the operating temperature need to consider to prevent the formation of these compounds. In the selected catalytic reactor with wet scrubber(SCR+WS), these compounds were removed after passing the device over 90% for CPs, 30~40% for CBs and 60% for PCBs. But, the systematic study have to perform to reduce the formation of PCDDs/PCDFs and precusors.

  • PDF