• Title/Summary/Keyword: chlorine water disinfection

Search Result 151, Processing Time 0.023 seconds

Simulation for the Flowing Water Purification with Spring Shape Inside Chamber (챔버 내측에 스프링형상을 갖는 유수형 자외선 살균장치 시뮬레이션)

  • Jung, Byung-Gyeon;Jeong, Byeong-Ho;Lee, Jin-Jong;Jung, Byeong-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.411-416
    • /
    • 2010
  • Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. In this paper, It describe the how to design optimal UV disinfection device for ground water, BWT and rainwater. Spring shape instrument silver coated located in inner side of disinfection chamber. It make lead the active flowing movement target water and maximize disinfection performance. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.

Effect of Monochloramine and Dimethylamine Concentrations on the NDMA Formation (모노클로라민과 디메틸아민 농도가 NDMA 생성에 미치는 영향)

  • Kim, Jong-O
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.755-759
    • /
    • 2008
  • As a disinfection byproduct, N-nitrosodimethylamine(NDMA) formation was studied according to chlorine, nitrogen, and carbon composition related to monochloramine and dimethylamine(DMA) concentrations. The highest NDMA formation was observed when the dimethylamine/monochloramine ratio was close to 1, and the formation was rapidly decreased when the ratio was less or greater than 1. The formation of NDMA increased with increasing chlorine/nitrogen ratio indicating the chlorine is a limiting factor. A rapid disinfection byproduct was formed at 72 hour contact time in this study. As the previous researches, pH was a significant factor for the NDMA formation.

Prediction of residual chlorine using two-component second-order decay model in water distribution network (이변량 감소모델을 적용한 배급수관망에서의 잔류염소농도 예측 및 이의 활용)

  • Kim, Young Hyo;Kweon, Ji Hyang;Kim, Doo Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.287-297
    • /
    • 2014
  • It is important to predict chlorine decay with different water purification processes and distribution pipeline materials, especially because chlorine decay is in direct relationship with the stability of water quality. The degree of chlorine decay may affect the water quality at the end of the pipeline: it may produce disinfection by-products or cause unpleasant odor and taste. Sand filtrate and dual media filtrate were used as influents in this study, and cast iron (CI), polyvinyl chloride (PVC), and stainless steel (SS) were used as pipeline materials. The results were analyzed via chlorine decay models by comparing the experimental and model parameters. The models were then used to estimate rechlorination time and chlorine decay time. The results indicated that water quality (e.g. organic matter and alkalinity) and pipeline materials were important factors influencing bulk decay and sand filtrate exhibited greater chlorine decay than dual media filtrate. The two-component second-order model was more applicable than the first decay model, and it enabled the estimation of chlorine decay time. These results are expected to provide the basis for modeling chlorine decay of different water purification processes and pipeline materials.

Behaviors of LAS in Reactions with Free Chlorine (鹽素와 反應에서 LAS의 擧動에 관한 연구)

  • Kim, Hea-tae;Lee, Hwan;Lee, Yoon-jin;Nam, Sang-ho
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.2
    • /
    • pp.106-114
    • /
    • 1997
  • When surfactants meet chlorine bleaches not only in the washing drums but also through the whole path from the stream to the river, it is not difficult to expect that they produce the harmful substances like DBPs. Furthermore considering wastewater that is contaminated by surfactants is used to discharge into drinking water sources via sewer system, it also can be imagined that residual surfactants would contribute to the some extent of DBPs' formation during chlorine disinfection in water treatment plants. Although the main behavior observed was the formation of chloroform during the reaction of LAS with free chlorine, the other manifest behaviors like the trends of pH, MBAS, free chlorine, the mole concentration of benzene ring and etc. were also investigated.

  • PDF

Application of Rechlorination for Adequate Disinfection Ability in Water Distribution System (관로 내 적정소독능 확보를 위한 재염소 기법의 적용)

  • Lee, Doo-Jin;Kim, Young-Il;Lee, Jong-Min;Jung, Nam-Jung;Kim, Yong-Woon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.701-707
    • /
    • 2006
  • Disinfectant residual should be maintained to achieve biological stability during distribution of treated water. The wide distribution of retention times associated with storage and transport of water in a network and the reactivity of disinfectants make it difficult to maintain adequate residuals at critical locations. Rechlorination at some intermediate locations may reduce the total disinfectant dose while keeping residuals within specified limits throughout the water distribution system. In order to select the adequate location of rechlorination for achieving to maintain of residual chlorine throughout the distribution system, EPANET was used in this study. EPANET was well predicted chlorine transport and residual loss in the distribution system. Location of rechlorination was selected to maintain 0.4mg/L of residual chlorine throughout a water distribution system by field investigation and model simulation. The quantity of chlorine may reduced 36.7% and provided smooth residual between 0.42 and 0.60mg/L, when rechlorination would be used continuously at strategic location within the distribution system.

Effect of Residual Chlorine Concentration on Water Pipe Corrosion and Corrosion Control Plan (수도관 부식에 대한 잔류염소 농도 영향 및 부식제어 방안)

  • Han, Keum-Seok;Park, Ju-Hyun;Park, Young-Bok;Kim, Seong-Jae;Kim, Hyen-Don;Choi, Young-June;Choi, In-cheol;Hong, Seong-Ho
    • Corrosion Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.12-19
    • /
    • 2018
  • Langelier Index (LI) is used as a tap water corrosiveness index. Residual chlorine in tap water induces corrosion inside water pipes. This study takes a deeper look into the effect of residual chlorine in water pipes. Comparison between tap waters of Y and K water treatment plant (WTP) shows that the LI index of K WTP is lower than that of Y. However, the corrosion rate of Y WTP is higher than that of K WTP. This means that the higher the concentration of residual chlorine in tap water, the higher the corrosion rate of pipe materials. When calcium hydroxide was added to tap water, the corrosiveness index was improved and thus the corrosion rate reduced. It is possible to increase the disinfection efficiency by increasing the duration of residual chlorine and suppressing the rust generation of water pipes and to supply minerals. A guideline for corrosion control with residual chlorine should be set up. The effects of residual chlorine should be included in the corrosiveness index of tap water.

Variations of Disinfection By-products in a Chlorinated Drinking Water Distribution System

  • Lee, Soo-Hyung;Park, Jeong-Kun;Lee, Hyung-Jun;Kim, He-Kap
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.2
    • /
    • pp.71-78
    • /
    • 2000
  • The chlorination of municipal drinking water supplies leads to the formation of so-called disinfection by-products(DBPs), many of which have been reported to cause harmful health effects based on animal studies. This study was conducted: 1) to observe seasonal changes in the major DBPs at four sampling sites on a drinking water distribution system located in Chunchon, Kangwon Do; and 2) to examine the effects of major water quality parameters on the formation of DBPs. During the field sampling, the water temperature, pH, and total and free chlorine residuals were all measured. The water samples were then analyzed for total organic carbon(TOC) and eight disinfection by-products in the laboratory. Chloroform, dichloroacetic acid, and trichloroacetic acid were the major constituents of the measured DBPs. The concentrations of the total DBPs were highest in fall, particularly in October, and lowest in summer. The concentrations of the total DBPs increased with increasing TOC concentrations. Multiple regression analyses showed that the concentrations of chloroform, bromodichloromethane, and chloral hydrate were linearly correlated with the pH. Other water parameters were not included in the regression equations. Accordingly, these results suggest that TOC and pH are both important factors in the formation of DBPs.

  • PDF

Reaction coefficient assessment and rechlorination optimization for chlorine residual equalization in water distribution networks (상수도 잔류염소농도 균등화를 위한 반응계수 추정 및 염소 재투입 최적화)

  • Jeong, Gimoon;Kang, Doosun;Hwang, Taemun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1197-1210
    • /
    • 2022
  • Recently, users' complaints on drinking water quality are increasing according to emerging interest in the drinking water service issues such as pipe aging and various water quality accidents. In the case of drinking water quality complaints, not only the water pollution but also the inconvenience on the chlorine residual for disinfection are included, thus various efforts, such as rechlorination treatment, are being attempted in order to keep the chlorine concentration supplied evenly. In this research, for a more accurate water quality simulation of water distribution network, the water quality reaction coefficients were estimated, and an optimization method of chlorination/ rechlorination scheduling was proposed consideirng satisfaction of water quality standards and chlorine residual equalization. The proposed method was applied to a large-scale real water network, and various chlorination schemes were comparatively analyzed through the grid search algorithm and optimized based on the suitability and uniformity of supplied chlorine residual concentration.

Study on Methodology for Reducing Dead Zone Flow within Chlorine Contactor Installing Porous Baffles (유공벽을 이용한 우류식 염소접촉조 사류 저감 방안 연구)

  • Park, Hyun-Ho;Park, No-Suk;Cha, Min-Whan;Kim, Sa-Dong;Won, Chan-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.519-525
    • /
    • 2010
  • From the results of tracer test for the existing chlorine contactor in Y water treatment plant, $T_{10}$ and $T_{10}$/T were calculated as 130 min and 0.16, respectively. Therefore it required the modification schemes for improving hydraulic efficiency, surrogated by T10 and $T_{10}$/T, and disinfection performance. In this study, in order to reduce dead zone within contactor, the installation of porous baffles in the near of each corner was suggested and verified using transient CFD(Computational Fluid Dynamics) simulation technique and tracer tests on dynamic condition. From the results of simulation and tracer tests, it was revealed that porous baffles installed have been effective to reduce dead zone within contactor, and increase plug flow fraction.

Disinfection efficacy of slightly acidic electrolyzed water (SlAEW) against some fresh vegetables (미산성 차아염소산수의 신선 채소류에 대한 살균 유효성)

  • Park, Kee-Jai;Lim, Jeong-Ho;Jung, Heeyong;Jeong, Mooncheol
    • Food Science and Preservation
    • /
    • v.24 no.2
    • /
    • pp.312-319
    • /
    • 2017
  • In the present study, disinfection efficacy of slightly acidic electrolyzed water [SlAEW, 30 ppm of effective chlorine at $20{\pm}1^{\circ}C$, oxidation-reduction potential (ORP) $562{\pm}23mV$, pH 6.4] on 4 kinds of vegetables (lettuce leaf, endive leaf, perilla leaf and kale leaf) was evaluated to obtain a microbial reduction characteristics which are necessary to design a process control for non-thermal sterilization of fresh vegetables. Active chlorine, residual chlorine, microbial counts and residual microbial counts, which are the key factors in the non-thermal sterilization process were measured by dipping them in SlAEW three times for 30 minutes in order to analyze the relationship between factors. Total microbial count was decreased mostly during the first 10 minutes of washing, and the limit value that can be reduced by immersion treatment was 3 log CFU/g for the total microbial count surviving in 4 kinds of vegetables. The total number of microorganism that can be reduced by washing in SIAEW for 10 min was found to be about 2 log CFU/g on average. In addition, the active chlorine decreased in the initial 10 minutes in 2.2 ppm, 2.0 ppm, 1.7 ppm and 2.5 ppm in lettuce, perilla leaf, endive leaf and kale leaf, respectively, and about 50-80% of the chlorine was reduced in the initial 10 min appear.