• 제목/요약/키워드: chlorine decay

검색결과 38건 처리시간 0.03초

하수의 염소 소독시 총잔류염소 감소 특성에 관한 연구 (Studies on Chlorine Demand and Its Decay Kinetics in Chlorinated Sewage Effluents)

  • 백영석;손진식
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.176-183
    • /
    • 2005
  • Chlorination of wastewater is recently practiced in Korea. While many researchers have studied the kinetics of aqueous chlorine(HOCl) with nitrogeneous compounds and other organic/inorganic contaminants in drinking water, the researches of wastewater chlorination are relatively few. The purpose of this study was to investigate the chlorine decay kinetics and parameters on wastewater chlorination. Chlorine decay rate increased with increasing initial chlorine concentration. The parameters affecting chlorine decay rate were different in each wastewater treatment plant. One of the most important parameters affecting chlorine decay was initial chlorine concentration, and other parameters such as $NH_3-N$, total coliform, $UV_{254}$ and Fe were also affected. The decay ratio of chlorine was decreased with increasing initial chlorine concentration, and the disinfection efficiency showed good correlation with the decay ratio.

EPANET 2.0과 관망실험을 통한 배수관망 염소농도 감쇄 비교연구 (A comparative study for the decay of chlorine residual using EPANET2.0 and an experimental pipeline system)

  • 백다원;김현준;김상현
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.411-419
    • /
    • 2018
  • The residual chlorine concentration is an essential factor to secure reliable water quality in the water distribution systems. The chlorine concentration decays along the pipeline system and the main processes of the reaction can be divided into the bulk decay and the wall decay mechanisms. Using EPANET 2.0, it is possible to predict the chlorine decay through bulk decay and wall decay based on the pipeline geometry and the hydraulic analysis of the water distribution system. In this study, we tried to verify the predictability of EPANET 2.0 using data collected from experimental practices. We performed chlorine concentration measurement according to various Reynolds numbers in a pilot-scale water distribution system. The chlorine concentration was predicted using both bulk decay model and wall decay model. As a result of the comparison between experimental data and simulated data, the performance of the limited $1^{st}$-order model was found to the best in the bulk decay model. The wall decay model simulated the initial decay well, but the overall chlorine decay cannot be properly predicted. Simulation also indicated that as the Reynolds number increased, the impact of the wall.

가상의 물 수요곡선에 따른 수충격에 의한 염소농도변동 모의연구 (Simulation of chlorine decay by waterhammer in water distribution system based on hypothetical water demand curve)

  • 백다원;김현준;김상현
    • 상하수도학회지
    • /
    • 제32권2호
    • /
    • pp.107-113
    • /
    • 2018
  • Maintaining adequate residual chlorine concentration is an important criteria to provide secure drinking water. The chlorine decay can be influenced by unstable flow due to the transient event caused by operation of hydraulic devices in the pipeline system. In order to understand the relationship between the transient event and the chlorine decay, the probability density function based on the water demand curve of a hypothetical water distribution system was used. The irregular transient events and the same number of events with regular interval were assumed and the fate of chlorine decay was compared. The chlorine decay was modeled using a generic chlorine decay model with optimized parameters to minimize the root mean square error between the experimental chlorine concentration and the simulated chlorine concentration using genetic algorithm. As a result, the chlorine decay can be determined through the number of transients regardless of the occurrence intervals.

이변량 감소모델을 적용한 배급수관망에서의 잔류염소농도 예측 및 이의 활용 (Prediction of residual chlorine using two-component second-order decay model in water distribution network)

  • 김영효;권지향;김두일
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.287-297
    • /
    • 2014
  • It is important to predict chlorine decay with different water purification processes and distribution pipeline materials, especially because chlorine decay is in direct relationship with the stability of water quality. The degree of chlorine decay may affect the water quality at the end of the pipeline: it may produce disinfection by-products or cause unpleasant odor and taste. Sand filtrate and dual media filtrate were used as influents in this study, and cast iron (CI), polyvinyl chloride (PVC), and stainless steel (SS) were used as pipeline materials. The results were analyzed via chlorine decay models by comparing the experimental and model parameters. The models were then used to estimate rechlorination time and chlorine decay time. The results indicated that water quality (e.g. organic matter and alkalinity) and pipeline materials were important factors influencing bulk decay and sand filtrate exhibited greater chlorine decay than dual media filtrate. The two-component second-order model was more applicable than the first decay model, and it enabled the estimation of chlorine decay time. These results are expected to provide the basis for modeling chlorine decay of different water purification processes and pipeline materials.

상수도 공급과정 중 재염소 투입에 따른 잔류염소농도 수체감소계수 예측모델 개발 (Development of prediction models of chlorine bulk decay coefficient by rechlorination in water distribution network)

  • 정보배;김기범;서지원;구자용
    • 상하수도학회지
    • /
    • 제33권1호
    • /
    • pp.17-29
    • /
    • 2019
  • This study developed prediction models of chlorine bulk decay coefficient by each condition of water quality, measuring chlorine bulk decay coefficients of the water and water quality by water purification processes. The second-reaction order of chlorine were selected as the optimal reaction order of research area because the decay of chlorine was best represented. Chlorine bulk decay coefficients of the water in conventional processes, advanced processes before rechlorination was respectively $5.9072(mg/L)^{-1}d^{-1}$ and $3.3974(mg/L)^{-1}d^{-1}$, and $1.2522(mg/L)^{-1}d^{-1}$ and $1.1998(mg/L)^{-1}d^{-1}$ after rechlorination. As a result, the reduction of organic material concentration during the retention time has greatly changed the chlorine bulk decay coefficient. All the coefficients of determination were higher than 0.8 in the developed models of the chlorine bulk decay coefficient, considering the drawn chlorine bulk decay coefficient and several parameters of water quality and statistically significant. Thus, it was judged that models that could express the actual values, properly were developed. In the meantime, the chlorine bulk decay coefficient was in proportion to the initial residual chlorine concentration and the concentration of rechlorination; however, it may greatly vary depending on rechlorination. Thus, it is judged that it is necessary to set a plan for the management of residual chlorine concentration after experimentally assessing this change, utilizing the methodology proposed in this study in the actual fields. The prediction models in this study would simulate the reduction of residual chlorine concentration according to the conditions of the operation of water purification plants and the introduction of rechlorination facilities, more reasonably considering water purification process and the time of chlorination. In addition, utilizing the prediction models, the reduction of residual chlorine concentration in the supply areas can be predicted, and it is judged that this can be utilized in setting plans for the management of residual chlorine concentration.

해수에서의 소독제 거동 예측 모델에 관한 연구 (Modeling of Chlorine Disinfectant Decay in Seawater)

  • 한지희;손진식
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.9-17
    • /
    • 2016
  • Disinfectant/oxidation process is a crucial process in water treatment for supplying safe drinking water. Chlorination is still widely used for water treatment area due to its effectiveness on microbial inactivation and economic feasibility. Recently, disinfection concern in marine environment is increasing, for example, movement of hazardous marine organism due to ballast water, marine environmental degradation due to power plant cooling water discharge, and increase of the amount of disinfectant in the offshore plant. It is needed to conduct the assessment of disinfectant behavior and the development of disinfectant prediction model in seawater. The appropriate prediction model for disinfectant behavior is not yet provided. The objective of the study is to develop chlorine decay model in seawater. Various model types were applied to develop the seawater chlorine decay model, such as first order decay model, EPA model, and two-phase model. The model simulation indicated that chlorine decay in seawater is influenced by both organic and inorganic matter in seawater. While inorganic matter has a negative correlation with the chlorine decay, organic matter has a positive correlation with the chlorine decay.

Pilot 규모의 모의 관망에서의 염소 농도 예측 (Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System)

  • 김현준;김상현
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

정수처리에서 염수요구량 및 반응거동에 관한 연구 (Evaluation of Chlorine Demand and Chlorine Decay Kinetics for Drinking Water)

  • 이윤진;조관형;최종헌;명복태;남상호
    • 한국환경보건학회지
    • /
    • 제27권1호
    • /
    • pp.27-35
    • /
    • 2001
  • This aim of the work presented in this paper is to investigate the factors that affcet chlorine decay and to develop functional relationships that can be used to enhance the durability of network models. predictive relationships were established that correlated the rate of chlorine decay to the various water conditions such as DOC, N $H_3$-N, initial chlorine, contact time, temperature and pH values. Free chlorine residual decreased with increasing temperature, DOC, N $H_3$-N, reaction time and chlorine dose. At 2$0^{\circ}C$, pH 7, The initial chlorine demand per mg as DOC/L and mg as N $H_3$-N/L was about 0.43, 2.69 mg/$\ell$ respectively at 180 minutes contact time. The Reaction between chlorine and humic acids was lasted intil 48hr, but the reaction between chlorine and N $H_3$-N was almost completed in 180 min. When the temperature is raised by 1$0^{\circ}C$, chlorine is more consumed about 0.25 mg/$\ell$ in the absence of organic substances and it is more consumed about 3.4 mg/$\ell$ in the presence of humic acid (5 mg/$\ell$) in water at pH 7 for 180 min. Regression Analysis created the resulting prediction equation for the chlorine decay in a SPSS package of the computer system. The model is as follows; $C_{t}$=1.239+0.707(Co)-0.000529(Time)-0.0112(Temp)+0.02227(pH)-0.42(DOC)-2.132(N $H_3$-N).).

  • PDF

EPANET을 이용한 상수도 관망의 잔류염소 거동 예측 (Chlorine Residual Prediction in Drinking Water Distribution System Using EPANET)

  • 유희종;김주원;정효준;이홍근
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.8-15
    • /
    • 2003
  • In this study, chlorine dose at water storage tank was predicted to meet the recommended guideline for free chlorine residual in drinking water distribution system, using EPANET which is a computer program that performs extended Period simulation of hydraulic and water quality behavior within pressurized pipe networks. The results may be summarized as follows. The decay of chlorine residual by season varied considerably in the following order; in summer ($25^{\circ}C$) > spring and fall (15$^{\circ}C$) > winter (5$^{\circ}C$). For re-chlorination at water storage tank by season, season-varying chlorine dose was required at its maximum of 1.00 mg/l in summer and minimum of 0.40 mg/l in winter as free chlorine residual. The decay of chlorine residual through out the networks increased with water age spent by a parcel of water in the network except for some points with low water demand. In conclusion, the season-varying chlorine dose as well as the monitoring of water quality parameters at the some points which showed high decay of chlorine residual may be necessary to deliver the safe drinking water.

하수재이용수의 유리잔류염소 수체감소 특성 연구 (Characteristics of Residual Free Chlorine Decay in Reclaimed Water)

  • 강성원;이재영;이현동;박재현;곽필재;오현제
    • 대한환경공학회지
    • /
    • 제35권4호
    • /
    • pp.276-282
    • /
    • 2013
  • 하수재이용수는 부족한 수자원 문제를 해결할 수 있는 대표적인 대안으로 주목받고 있다. 본 연구에서는 하수재이용수의 공급시 유리잔류염소의 수체감소 특성을 온도별(5, 15, $25^{\circ}C$), 초기 주입농도별(1, 2, 4, 6 mg/L)로 살펴보았고 그 결과를 이용하여 최적 염소주입량을 산정하는 방법에 대하여 연구하였다. 하수재이용수는 정수와 비교하여 염소주입시 반응속도가 초기에 매우 빠르게 나타나 기존의 general first-order decay model ($C_t=C_o(e^{-k_bt})$)을 사용하기에 부적합하여 exponential firstorder decay model ($C_t=a+b(e^{-k_bt})$)을 적용한 결과 유리잔류염소의 감소를 더욱 정확하게 예측할 수 있었다($r^2$=0.872~0.988). 수체감소계수를 산출한 결과 초기주입량 1 mg/L, $25^{\circ}C$의 조건에서 653 $day^{-1}$로 가장 크게 나타났고, $5^{\circ}C$, 초기주입량 6 mg/L의 조건에서 3.42 $day^{-1}$로 가장 낮았다. 수체감소계수는 온도가 증가함에 따라 수체감소계수는 증가하는 경향을 나타내었고, 초기 주입농도가 증가함에 따라 수체감소계수는 감소하는 경향을 나타내었다. 적정 초기 염소요구량을 산정하기 위해서 전체 반응기간을 0~30분, 30~5,040분으로 구분한 후, 30~5,040분의 실험결과를 사용한 예측식을 사용함으로써 더욱 정확한 염소주입량 산정을 할 수 있었다. 또한, 온도별로 최적 염소주입량을 산정한 결과 염소주입 후 4시간이 경과한 시점에서 유리잔류염소 0.2 mg/L를 유지하기 위해서는 온도(x)별 초기 염소요구량(y)의 관계를 y = 1.409 + 0.450x와 같이 얻을 수 있었다.