• Title/Summary/Keyword: chiral chromatography

Search Result 115, Processing Time 0.022 seconds

Resolution of Salbutamol Enantiomers in Human Urine by Reversed-Phase High Performance Liquid Chromatography after Derivatization with 2,3,4,6-Tetra-O-acetyl-${\beta}$-D-glucopyranosyl Isothiocyanate

  • Kim, Kyeong-Ho;Kim, Tae-Kyun
    • Archives of Pharmacal Research
    • /
    • v.21 no.2
    • /
    • pp.217-222
    • /
    • 1998
  • A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with 2,3,4,6-tetra-O-acetyl-$\beta$-D-glucopyranosyl isothiocyanate, the diastereomeric derivatives were resolved (Rs=1.83) on $5{\mu}m$ octadecylsilan column using 35% acetonitrile in 0.05M ammonium acetate buffer (pH=6) as a mobile phase with electrochemical detection. The diastereomeric derivatives were formed within 30 min. The detection limit of each enantiomer was 20 ng/ml (S/N=3).

  • PDF

Chiral Purity Test of Metoprolol Enantiomer After Derivatization with (-)-Menthyl Chloroformate by Reversed-Phase High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Choi, Pok-Wha;Hong, Seon-Pyo;Kim, Hyun-Ju
    • Archives of Pharmacal Research
    • /
    • v.22 no.6
    • /
    • pp.614-618
    • /
    • 1999
  • A reversed-phase high-performace liquid chromatographic method was developed to determine the optical purity of metoprolol enantiomers. The enantiomers were converted to diastereomeric derivatives using (-)-menthyl chloroformate reagent. Separation of the enantiomers as diastereomers was achieved by reversed-phase HPLC within 30 min using Inertsil C8 column. This method allowed determination of 0.05% of either enantiomer in the presence of its stereoisomer and method validation showed adequate linearity over the required range. Owing to the reaction condition during the derivatization with (-)-menthyl chloroformate, the possibility of racemization had to be established. Different ratios of (S)-(-)-metoprolol and (R)-(+)-metoprolol were prepared. Enantiomeric separation of these mixtures took place on a chiralcel OD column or, after derivatization with (-)-menthyl chloroformate, on a C8 column. The results form the these two independent separation systems were compared with trace racemization and were in very good agreement. No racemization was found during the experiment.

  • PDF

Separation of D and L Amino Acids by High-Performance Liquid Chromatography

  • Lee, Sun-Haing;Ryu, Jae-Wook;Park ,Kyoung-Sug
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 1986
  • Separation of optical isomers of some derivatives of amino acids by reversed-phase HPLC has been accomplished by adding a chelate of an optically active amino acid to copper(Ⅱ) to the mobile phase. Cu(Ⅱ) complexes of L-proline and L-hydroxyproline in the mobile phase showed different degrees of separation. Optical isomers of DNS derivatives of amino acids are selectively separated, but those of several other derivatives are not at all. The kinds of buffer agents, the pH, and the concentrations of acetonitrile and the Cu(Ⅱ) ligand all affect the separations. The elution behavior between D and L DNS-amino acids appears to depend on the alkyl side chain of the amino acids. A chromatographic mechanism is proposed that is based on a stereospecificity of the formation of ternary complexes by the D, L-DNS-amino acids and the chiral additive associated with the stationary phase. The steric effects of the ligand exchange reactions are related with the feasibility of cis and/or trans attack of the amino acids to the binary chiral chelate retained on the stationary phase.

Effective determination of nicotine enantiomers from e-liquids and biological fluids by high performance liquid chromatography (HPLC) using dispersive liquid-liquid microextraction (DLLME)

  • Song, Seunghoon;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.180-190
    • /
    • 2021
  • This study compared the efficacy of chiral GC and chiral HPLC for the analysis of nicotine. To develop a suitable dispersive liquid-liquid microextraction (DLLME) method, the following parameters were optimized: pH, extraction solvent, dispersive solvent, type and quantity of salt, and laboratory temperature. The validation of the method was carried out by the established HPLC method. The LODs were 0.11 ㎍/mL and 0.17 ㎍/mL for the (S)- and (R)- enantiomers, respectively. The LOQs were 0.30 ㎍/mL and 0.44 ㎍/mL, respectively. The optimal calibration range was between 0.30-18 ㎍/mL and 0.44-4.40 ㎍/mL, respectively, and the correlation coefficient (r2) was 0.9978-0.9996. The intra-day accuracy was 79.9-110.6 %, and the intra-day precision was 1.3-12.0 %. The inter-day accuracy was 87.8-108.0 %, and the inter-day precision was 4.0-12.8 %. E-liquid and biological fluids (urine and saliva) were analyzed using the established method.

Chiral Separation of Lactic Acid in Culture Media and Cells of Lactobacillus delbrueckii subsp. lactis as O-Pentafluoropropionylated (S)-(+)-3-Methyl-2-Butyl Ester by Achiral Gas Chromatography-Mass Spectrometry

  • Paik, Man-Jeong;Nguyen, Duc-Toan;Yoon, Jae-Hwan;Chae, Han-Seung;Kim, Kyoung-Rae;Lee, Gwang;Lee, Pyung-Cheon
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.7
    • /
    • pp.2418-2422
    • /
    • 2011
  • The enantiomeric separation of lactic acid for its absolute configuration has become important task for understanding its biological origin and metabolic process involved in the formation of lactic acid. It involves the conversion of enantiomers as diastereomeric O-pentafluoropropionylated (S)-(+)-3-methyl-2-butyl ester and the direct separation by gas chromatography-mass spectrometry on a achiral capillary column. The (R)- and (S)-lactic acids were completely separated with a high resolution of 1.9. The newly developed method showed good linearity (r ${\geq}$ 0.999), precision (% relative standard deviation = 3.4-6.2), and accuracy (% relative error = -7.7-1.4) with the detection limit of 0.011 ${\mu}g/mL$. When the method was applied to determine the absolute configuration of lactic acid in Lactobacillus delbrueckii subsp. lactis 304 (LAB 304), the composition (%) of (R)-lactic acid in the cell pellet and in the culture medium were $89.0{\pm}0.1$ and $78.2{\pm}0.4$, respectively. Thus, it was verified that the present method is useful for the identification and composition test of lactic enantiomers in microorganisms.

Chiral Separation of Derivatized Racemic Alcohols on Substitued Cyclodextrin Stationary Phases by Capillary Gas Chromatography (모세관 기체 크로마토그래피에 의한 치환된 Cyclodextrin 정지상을 이용한 알코올 유도체의 키랄분리)

  • Lee, Sun-Haing;Seo, Yeong-Ju;Lee, Kwang-Pill
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.2
    • /
    • pp.94-102
    • /
    • 1995
  • S-Hydroxypropyl(PH) ${\beta}$-cyclodextrin(hydrophilic), dialkyl(DA)-cyclodextrin(hydrophobic), trifluoroacetyl(TA) ${\gamma}$-cyclodextrin(intermediate) stationary phases were used for gas chromatographic separation of racemic alcohols and their derivatives. All the alcohols used for this experiment were derivatived by using trifluoro acetic anhydride, acetic anhydride, or trichloro acetic anhydride. It is apparent that the enantioselectivity of the enantiomeric pairs was very dependent on the type of acylation reagent. The best experimental condition of optical resolution of the alcohols and their derivatives was different on the polarity of the solute molecules. The chiral separation was also studied depending on temperature, polarity of the column, and hydrogen bonding ability and steric effect between the alchols and CD stationary phase. The chiral recognition mechanism is dependent not upon the kinds of the chiral stationay phases but upon the derivatization of the racemic alchols.

  • PDF

Effect of acid or base additive in the mobile phase on enantiomer separation of amino alcohols using polysaccharide derived chiral columns (다당유도체를 기초로 한 키랄 컬럼에서 이동상에서의 산 또는 염기 첨가제가 아미노 알코올의 광학분리에 미치는 영향)

  • Huang, Hu;Jin, Jing Yu;Lee, Wonjae
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.313-318
    • /
    • 2009
  • Liquid chromatographic enantiomer separation of amino alcohols was performed on several chiral columns based on polysaccharide derivatives under the mobile phase conditions containing acid or base additive. The chromatographic parameters were greatly influenced by the nature of the mobile phase containing acid or base additive as well as the used chiral columns. Compared to chromatographic results obtained in the mobile phase containing base additive (0.1% triethylamine), especially, Chiralcel OD showed dramatically enhanced separation factors and resolution factors with reduced capacity factors under the mobile phase condition containing acidic additive (0.1% trifluoroacetic acid). When the mobile phase containing 0.05% trifluoroacetic acid and 0.05% triethylamine was used on Chiralcel OD, the greatest separation factors and resolution factors among all other mobile phase conditions in this study were observed.

Chiral Separation of Salbutamol Enantiomers in Human Plasma

  • Seo, Joung-Min;Kim, Kyeong-Ho
    • Archives of Pharmacal Research
    • /
    • v.17 no.4
    • /
    • pp.244-248
    • /
    • 1994
  • A stereoselective and sensitive high performance liquid chromatography using fluoresecence deterctor was examined for the determination of R(-) and S(+)-salbutamol in human plasma. Solid phase extraction method using silica as sorbent was used to extract salbutamol racemates from the plasma matrices. After fractionation and freeze-drying of the eluates containing salbutamol racemates, they were separated and quantified on a chirla stationary column. The detection limit of each enantiomer was 2 ng/ml in human plasma (S/N=3).

  • PDF