• Title/Summary/Keyword: chimney effect

Search Result 36, Processing Time 0.023 seconds

Study on the Natural Convection Heat-Transfer Enhancement in Radial Heat Sink Using the Perforation and Flow Guide (천공과 유동 가이드를 활용한 방사형 히트싱크의 자연대류 열전달 향상에 관한 연구)

  • Jeon, Sora;Li, Bin;Byon, Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.339-345
    • /
    • 2016
  • In this study, we numerically investigate the thermal performance of an enhanced radial heat sink with a perforation and chimney structure. We estimate the thermal performance of the enhanced radial heat sink, and compared it with that of a conventional radial heat sink. The results show that the radial heat sink with perforation has a higher thermal performance when either of the diameter and the number of perforations is high. With regards to the radial heat sink with a chimney structure, we investigate primarily the effect of the fin number, and the spacing between the chimney and the base plate on the thermal performance. The results show that there are optimal values for the fin number and the spacing between chimney and base plate. In addition, the enhanced radial heat sinks have maximum thermal performance when facing upward ($0^{\circ}$), while it has worst performance when facing sideward ($90^{\circ}$). The perforation and chimney are shown to cause thermal performance enhancements of 17% and 20%, respectively, compared with a conventional radial heat sink. The proposed method is useful for starting business, and is useful in terms of venture and entrepreneurship.

The slenderness effect on wind response of industrial reinforced concrete chimneys

  • Karaca, Zeki;Turkeli, Erdem
    • Wind and Structures
    • /
    • v.18 no.3
    • /
    • pp.281-294
    • /
    • 2014
  • There are several parameters affecting the response of industrial reinforced concrete (RC) chimneys, i.e., the severity of wind and earthquake loads acting to the structure, structural properties such as height and cross section of the chimney, the slenderness property of the structure etc. One of the most important parameter that should be considered while understanding the wind response of industrial RC chimneys is slenderness property. Although there is no certain definition for slenderness effect on these structures, some standards like ASCE-7 define slenderness from different aspects of the structural properties. In the first part of this study, general information about the definition of slenderness in the well-known standards and ten selected industrial RC chimneys are given. In the second part of the study, brief information about wind load standards that are used for calculating wind loads namely ACI 307/98, CICIND 2001, DIN 1056, TS 498 and Eurocode 1 is given. In the third part of the study, calculated wind loads for selected chimneys are represented. In the fourth part of this study, the internal forces obtained from load combinations that are applied to chimneys and some graphs presenting the effect of slenderness on chimneys are given. In the last part of the study, a conclusion and discussion part is taking place.

Determinaton of Chloride Ion Captured into Strong NaOH Solution from Chimney by Capillary Electrophoresis (모세관 전지영동법에 의한 굴뚝에서 포집된 NaOH 용액속의 염소이온의 측정)

  • 임인덕;성용익;김양선;임흥빈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.3
    • /
    • pp.327-333
    • /
    • 1999
  • Determination of chloride ion in concentrated NaOH solution by capillary electrophoresis has been studied. The analysis was performed by indirect UV absorption detection using chromate buffer at 254nm. The matrix effect of the sample has been observed so that the sensitivity in strong NaOH solutaion has decreased up to 10% of that in distilled water. The pH effect of the sample on the sensitivity of CE peaks has been investigated. The method for increasing the sensitivity have been investigated and the optimum pH and concentration of the buffer were 7.5 and 10mM, respectively. A cationic surfactant cetyltrimethylammonium bromide(CTAB), was added to a buffer solution in order to reverse the electroosmotic flow(EOF) in the capillary. This results in a short analysis time and better peak shapes. Using this optimum condition, the determination of chloride ion in real environmental sample has been performed, which is captured in strong NaOH absorbent prepared for absorbing gas from chimney. The standard addition method has been applied for the quantitative analysis, and it was obtained the good reproducibility.

  • PDF

Analysis of Natural Convection Heat Transfer from Electronic Modules in a Plasma Display Panel (플라즈마 영상장치의 채널 사이에 놓인 전자모듈의 자연대류 열전달 해석)

  • Choi, In-Su;Park, Byung-Duck;Seo, Joo-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 2004
  • The heat transfer characteristics of a plasma display panel has been investigated for cooling an electronic module. Hence, a two dimensional $\kappa-{\varepsilon}$ turbulent model was developed to predict the temperatures of the panel and module. The heat conduction was solve for the material region. To consider the mixed convection at the solid-fluid interfaces between the air and the panel and module, the energy equation was solved simultaneously. When the electronic module stands face to face with the panel, the temperatures of panel and module are lower than other arrangement due to the chimney effect. However the gap between the panel and module does not affect significantly the maximum temperature when the aspect ratio is less than 0.1. To maintain the maximum temperature of the module under a certain limit, the passage of air should be well designed by the optimal layout of electronic modules which have different heat emission.

  • PDF

YOLOv5-based Chimney Detection Using High Resolution Remote Sensing Images (고해상도 원격탐사 영상을 이용한 YOLOv5기반 굴뚝 탐지)

  • Yoon, Young-Woong;Jung, Hyung-Sup;Lee, Won-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_2
    • /
    • pp.1677-1689
    • /
    • 2022
  • Air pollution is social issue that has long-term and short-term harmful effect on the health of animals, plants, and environments. Chimneys are the primary source of air pollutants that pollute the atmosphere, so their location and type must be detected and monitored. Power plants and industrial complexes where chimneys emit air pollutants, are much less accessible and have a large site, making direct monitoring cost-inefficient and time-inefficient. As a result, research on detecting chimneys using remote sensing data has recently been conducted. In this study, YOLOv5-based chimney detection model was generated using BUAA-FFPP60 open dataset create for power plants in Hebei Province, Tianjin, and Beijing, China. To improve the detection model's performance, data split and data augmentation techniques were used, and a training strategy was developed for optimal model generation. The model's performance was confirmed using various indicators such as precision and recall, and the model's performance was finally evaluated by comparing it to existing studies using the same dataset.

한국표준원전 원자로의 단열 설계에 관한 연구

  • 백세진;김석범;주경인;김영보;정종식
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.317-322
    • /
    • 1996
  • 고온으로 유지되는 원자로에는 열손실을 줄이기 위하여 단열재가 설치되어 있다. 일반직으로 열손실 시험에서 나타난 실제 열손실은 설계상의 열손실보다 크며, 이의 원인은 단열설계의 부적절, 단열재 설치상의 미흡 등에 기인한다. 본 연구에서는 단열재 두께와 간격에 대한 열전달 특성을 분석하여 단열설계변수를 최적화하며, chimney effect에 의한 열손실 증가를 정량적으로 분석하였다. 본 연구의 결과는 원자로용기 뿐아니라 가압기, 증기발생기 등의 큰 규모의 단열재 설계에 적용될 수 있다.

  • PDF

Stack Effect in High-Rise Buildings: A Review

  • Mijorski, Sergey;Cammelli, Stefano
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.4
    • /
    • pp.327-338
    • /
    • 2016
  • This technical paper presents a detailed review of the stack effect phenomenon and of the associated implications pertaining to the design and construction of high-rise buildings in regions of extreme climatic conditions. The present review is focused on both the classical 'chimney' effect as well as on the reverse stack effect, which are respectively related to cold and hot climates. For the purposed of the work here presented, the ASHRAE (2013) design conditions of Astana (Kazakhstan) and Riyadh (Kingdom of Saudi Arabia) were selected. A 230 m tall residential building of rectangular floor plan was numerically modelled in the context of the climatic conditions of the two abovementioned cities and a number of sensitivity analyses were performed, covering parametric changes of: temperature, façade air tightness, site wind speeds and wind directions.

The Effects of Operational and Mechanical Factors on the Performance of Rice-Husk Furnace (왕겨연소기(燃燒機)의 성능(性能)에 영향(影響)을 마치는 설계(設計) 및 작동인자(作動因子)에 관(關)한 연구(硏究))

  • Park, Seung Je;Noh, Sang Ha
    • Journal of Biosystems Engineering
    • /
    • v.8 no.2
    • /
    • pp.39-48
    • /
    • 1983
  • This study was performed to obtain the basic data which could be used for the modification of the manual center-burner-type rice-husk furnace into a small scale automatic type for the multi-purpose use in the farm. For this purpose, first, the utilization feasibility of the rice-husk furnace in the farm was analyzed briefly in aspects of available amount of rice-husk for the fuel, annual operation time and replaceble amount of residential heating energy with rice-husk in the farm. For the experiment a prototype furnace geared with an automatic feeding device was fabricated, and feed rate, mold size and chimney height were changed to investigate the combustion efficiency of rice-husk and thermal efficiency of the furnace. Also, optimum and limiting operational factors were observed in each treatments. The results obtained are summarized as follows. 1. If the rice-husk is intensively used for residential heating in the farm for winter season, on an average 51 percent of the total heating energy can be replaced with the rice-husk. Therefore, development of a small scale automatic rice-husk furnace was recognized to be feasible. 2. The operational condition depending on husk-feed rates was very important factor for successive steady burning operation of the given furnace. When the feed-rate was 1.5 kg/hr, the top of the burning zone should be kept at the position about 55 cm from the bottom of the combustion chamber with the periodic removal of ash (termed as steady state position), which was 18 cm above the mold waist. When the feed rates were 2.4 kg/hr and 3.0 kg/hr, the steady state position was at about 4 cm above the mold waist. 3. The mold size affected inflow rate of air into the furnace and consequently CO content in the exhaust gas. The relatively bigger mold gave positive effect on the air-inflow rate. 4. When the husk-feed rates were 1.5 kg/hr, 2.4 kg/hr, 3.0 kg/hr, the combustion efficiencies of the rice-husk were 98.5%, 97.4% and 95.0%, the thermal efficiencies of the furnace were 93.4%, 93.2% and 87.6%, and CO content in the exhaust gas were 1.21%, 1.03%, and 2.43%, respectively. The air-inflow rates were decreased with the increase of feed rates. When the amount of excess air was 30-40%, the CO content in the exhaust gas was at the minimum level. 5. When the chimney height was lowered from 260 cm to 96 cm, the air-inflow rate was slightly decreased, but the average temperature in the combustion chamber, CO content in the exhaust gas and combustion and thermal efficiencies were not changed significantly. 6. The incidental problems associated with the protytype furnace were accumulation of the ash inside the mold, accumulation of the cinder between the outer-drum of the furnace and the combustion chamber wall, and accumulation of the cinder in the chimney.

  • PDF

Mineralogical and Geochemical Studies on the Daum Vent Field, Central Indian Ridge (인도양 중앙해령 Daum 열수분출대의 광물·지구화학적 연구)

  • Ryoung Gyun Kim;Sun Ki Choi;Jonguk Kim;Sang Joon Pak;Wonnyon Kim
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.765-779
    • /
    • 2023
  • The Daum Vent Field (DVF) was newly discovered in the Central Indian Ridge during the hydrothermal expedition by the Korea Institute of Ocean Science & Technology (KIOST) in 2021. In this paper, we describe the detailed mineralogy and geochemistry of hydrothermal chimney and mound to understand the nature of hydrothermal mineralization in the DVF. The mineral assemblages (pyrite±sphalerite±chalcopyrite) of dominant sulfides, FeS contents (mostly <20 mole %) of sphalerite, and (Cu+Zn)/Fe values (0.001-0.22) of bulk compositions indicate that the DVF has an strong affinity with basaltic-hosted seafloor massive sulfide (SMS) deposit along the oceanic ridge. Combined with the predominance of colloform and/or dendritic-textured pyrite and relatively Fe-poor sphalerite in chimneys, the fluid-temperature dependency of trace element systematics (Co, Mn, and Tl) between chimney and mound indicates that the formation of mound was controlled by relatively reducing and high-temperature fluids compared to chimney. The δ34S values (+8.31 to +10.52‰) of pyrite reflect that sulfur and metals were mainly leached from the associated basement rocks (50.6-61.3%) with a contribution from reduced seawater sulfur (38.7-49.4%). This suggests that the fluid-rock interaction, with little effect of magmatic volatile influx, is an important metal source for the sulfide mineralization in the DVF.

Experimental Study on the Radiative and Convective Cooling of Electronic Modules opposed to a Heated Vertical Plate (가열 수직 평판과 마주보는 전자모듈의 복사 및 대류 냉각에 대한 실험적 고찰)

  • Choi, In-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.8 no.2
    • /
    • pp.105-112
    • /
    • 2005
  • The characteristics of natural convection heat transfer combined with radiation in a vertical parallel plates has been investigated experimentally. The vertical channel is consisted with a heated wall and three protruding heating sources attached on the opposite wall. The cooling of modules has been experimented with heating the wall as well as modules themselves at different aspects ratios and heating fluxes. As the location of module is higher, the temperature becomes higher, but the increasement is smaller. When the aspect ratio is lower than 26, its effect on the temperature is not significant rather than that of the radiation heat transfer. Furthermore, the correlation of Nusselt number with the Rayleigh number are attempted, but additional treatment is needed to accomodate the cases of heating module and/or opposite wall.

  • PDF