• Title/Summary/Keyword: chemiluminescence analyzer

Search Result 16, Processing Time 0.02 seconds

Value of Combined Detection of Serum CEA, CA72-4, CA19-9 and TSGF in the Diagnosis of Gastric Cancer

  • Yin, Li-Kui;Sun, Xue-Qing;Mou, Dong-Zhen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3867-3870
    • /
    • 2015
  • Background: To explore whether combined detection of serum tumor markers (CEA, CA72-4, CA19-9 and TSGF) improve the sensitivity and accuracy in the diagnosis of gastric cancer (GC). Materials and Methods: An automatic chemiluminescence immune analyzer with matched kits were used to determine the levels of serum CEA, CA72-4, CA19-9 and TSGF in 45 patients with gastric cancer (GC group), 40 patients with gastric benign diseases (GBD group) hospitalized in the same period and 30 healthy people undergoing a physical examination. The values of those 4 tumor markers in the diagnosis of gastric cancer was analyzed. Results: The levels of serum CEA, CA72-4, CA19-9 and TSGF of the GC group were higher than those of the GBD group and healthy examined people and the differences were significant (P<0.001). The area under receiver operating characteristic (ROC) curves for single detection of CEA, CA72-4, CA19-9 and TSGF in the diagnosis of GC was 0.833, 0.805, 0.810 and 0.839, respectively. The optimal cutoff values for these 4 indices were 2.36 ng/mL, 3.06 U/mL, 5.72 U/mL and 60.7 U/mL, respectively. With combined detection of tumor markers, the diagnostic power of those 4 indices was best, with an area under the ROC curve of 0.913 (95%CI 0.866~0.985), a sensitivity of 88.9% and a diagnostic accuracy of 90.4%. Conclusions: Combined detection of serum CEA, CA72-4, CA19-9 and TSGF increases the sensitivity and accuracy in diagnosis of GC, so it can be regarded as the important means for early diagnosis.

The Effect of L-carnitine and Acetylcarnitine on Sperm Parameters in vitro (생체외 L-carnitine과 Acetylcarnitine의 정자지표 개선 효과)

  • Lee, Wan;Park, Nam-Cheol
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.29 no.2
    • /
    • pp.149-157
    • /
    • 2002
  • Objectives: To assess the scavenging effect of carnitine derivatives on oxidative damage to sperm during sperm processing, cryopreservation and thawing. Materials and Methods: Fresh semen samples from 20 normal healthy volunteers were collected by masturbation after at least 48 hours abstinence. After liquefaction of semen samples at room temperature, the specimens were diluted with sperm wash media (Ham's F-10, Life technologics) to a uniform density of $20{\times}10^6/ml$. L-carnitine or acetylcarnitine were added with various concentration of $0{\mu}M$, $10{\mu}M$, $30{\mu}M$ in semen sample or cryoprotectant. All specimens were cryopreservated at $-196^{circ}C$ $LN_2$ for 3 days. Sperm motility, vitality, fertilizing capacity, reactive oxygen species formation and the level of lipid peroxidation were analyzed by computer assisted semen analyzer, eosin-nigrosin stain, hypoosmotic swelling test, chemiluminescence and thiobarbituric acid method, respectively, during sperm processing, cryopreservation and thawing. Results: The sperm motility was only increased in proportion to the concentration of acetylcarnitine with no statistical significance (p>0.05). The sperm vitality was also significantly improved in proportion to the concentration of acetylcarnitine with statistical significance (p<0.05). The sperm fertilizing capacity was significantly increased in proportion to the concentration of L-carnitine and acetylcarnitine and reactive oxygen species generation and lipid peroxidation were significantly decreased with same fashion (p<0.05). On comparison of effects between L-carnitine and acetylcarnitine, acetylcarnitine was superior to L-carnitine on the improvement of sperm motility and vitality as well as the suppression of reactive oxygen species generation and lipid peroxidation. Conclusions: These results suggest that carnitine derivatives have a scavenging effect against oxidative damages during sperm processing, cryopreservation and thawing. Therefore, carnitine derivatives may be useful as an oral antioxidant in patients with male infertility due to increased ROS generation.

The Study of Effects of Variable Parameters on Flame Structure and NOx Emission in Methane/Air Laminar Partially Premixed Flames (메탄/공기 층류 부분 예혼합화염에서 예혼합 정도에 따른 화염구조와 질소산화물의 배출에 미치는 영향에 관한 연구)

  • Oh, Jeong-Seog;Jeong, Yong-Ki;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.362-367
    • /
    • 2003
  • It is shown that the effect of variable parameters on flame structures and NOx emissions in the laminar partially premixed methane-air flames with a co-axial Bunsen burner. Objectives of this paper is to understand the effects of flow variables on NOx emissions and the flame structure with OH chemiluminescence, including reconstructed image by abel inversion processing at each conditions. A fuel flowrate of 200 [cc/min] was fixed and the amount of air was varied from 400 to 1200 [cc/min]. The experimental variables were equivalence ratio(${\Phi}$ fuel split percentage(${\sigma}$ and inner tube recess(x/D). Flow conditions were ranged from $1.36{\sim}4.76$(equivalence ratio), $50{\sim}100$(fuel split percentage) and $0{\sim}20$(inner tube recess). NOx analyzer and ICCD camera with a OH filter were used as a main experimental apparatus. In addition, Abel inversion, which is a kind of tomography and valuable to estimate a two-dimensional structure of co-axial flames from cubical information, was employed for combustion diagnostics. Results from this study indicate that the main effects depend on equivalence ratio and next sigma, x/D for NOx production and OH formation. Throughout Abel inversion, we could affirm the maximum position and the tendency of OH radical intensity by variants at five axial heights above the burner exit.

  • PDF

Relationship between exhaled nitric oxide and pulmonary function test in children with asthma (소아 천식에서 호기산화질소와 폐기능 검사의 관계)

  • Ko, Han-Seok;Chung, Sung-Hoon;Choi, Yong-Sung;Choi, Sun-Hee;Rha, Yeong-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.2
    • /
    • pp.181-187
    • /
    • 2008
  • Purpose : Asthma is characterized by reversible airway obstruction and bronchial hyperresponsiveness result from airway inflammation. Fraction of nitric oxide in expired air (FeNO) has recently been investigated as a noninvasive measure of airway inflammation. FeNO has been reported to correlate with induced sputum eosinophilia and methacholine challenge test that it is represent severity of asthma. The purpose of this study was to analyze the relationship of FeNO with pulmonary function tests in patients with intermittent asthma. Methods : Eighty children included in this study were diagnosed as asthma from April through August, 2005 in Department of Pediatrics, College of Medicine, Kyunghee University. They aged from 4 to 15 years who were able to conduct spirometry and FeNO monitoring. They did not have upper respiratory tract infection and did not use an asthma controller which contain corticosteroids within 4 weeks. Pulmonary function test was done and FeNO was measured with online tidal breathing method using a chemiluminescence NO analyzer (CLD 88 sp, Eco Medics, Duernten, Switzerland). The correlations between pulmonary function test and FeNO were analyzed using Spearman correlation coefficient method. Results : The mean of FeNO of subject was 16.88 parts per billion (ppb). The mean of forced expiratory volume in 1 second ($FEV_1$) was $0.890{\pm}0.455L$ and forced vital capacity (FVC) was $1.071{\pm}0.630L$. The mean of predicted $FEV_1%$ ($FEV_1%pred$) was $98.39{\pm}34.27%$ and $FEV_1/FVC$ was $88.53{\pm}19.49$. FeNO was significantly correlate with $FEV_1$ (r=0.345, P<0.01) and FVC (r=0.244, P<0.05). FeNO did not correlate with $FEV_1%pred$ or $FEV_1/FVC$. Conclusion : The measurement of FeNO could be a useful marker in the management of childhood asthma and it is evolving to provide a complementary role alongside existing pulmonary function test. We propose that measuring technique and establishment of normal reference range are important area for future research.

Absorption, Excretion and Antioxidative Effect of Rebamipide on Reproductive Organ (Rebamipide의 생식기관 내 흡수, 배설 및 항산화제로서 불임치료효과)

  • Kim, Jong Il;Park, Hyun Jun;Park, Nam Cheol
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.32 no.4
    • /
    • pp.301-314
    • /
    • 2005
  • Objective: Rebamipide is a propionic acid derivative that has an action of the inhibition of superoxide production and removal of hydroxyl radical with the sperm incubation and cryopreservation. In the present study, to investigate whether rebamipide is useful to treat male infertility and sterility, the author observed the antioxidative effects in patient with male infertility and also examined its absorption and distribution in rat genital organ. Methods: To measure the distribution of rebamipide in reproductive organ in the rat, carbon indicated rebamipide, $^{14}C-OPC-12759$, was orally administered to 10 Spraque-Dawley rats and its organ concentration in serum, liver, kidney, stomach, duodenum, colon, urinary bladder, seminal vesicle, epididymis and testicle were measured each time after 0.5, 1, 2, 4, 8 and 24 hours by using HPLC fluorescent method. The concentrations in semen were measured by HPLC fluorescent method in a sample of 50 infertile males who took 900 mg of rebamipide daily for 3 months. To measure the antioxidative effect and fertility rate for 3 months, each month before and after the treatment, sperm motility, vitality, the oxygen free radical formation, level of peroxidation, fetilizing capacity of semen sample which were obtained from infertile male patients by masturbation after at least 48 hours abstinence were analyzed by computer assisted semen analyzer, eosin-nigrosin stain, chemiluminescence, thiobarbituric acid method and hypo-osmotic swelling test. Simultaneously in a sample that wanted baby, both pregnancy and delivery were researched. Results: The $^{14}C-OPC-12759$ concentration in the body of white rats was highest in gastrointestinal organ like stomach, smal intestine and duodenum and followed by genital organ like seminal vesicle, testis and epididymis. The rebamipide concentration in semen of infertile males was $220.77{\pm}327.84ng/mL$ (SD) which showed a large deviation but it was higher than serum which was $126{\pm}76ng/mL$ (SD). In the infertile males, after the treatment with rebamipide, the level of seminal reactive oxygen species (ROS) and lipid peroxidation have significantly decreased in duration of the treatment (p<0.05) and sperm vitality and fertilizing capacity except sperm motility significantly improved on post treatment of 2~3 months (p<0.05). Out of the 41 cases who hoped for pregnancy, 15 cases (36.6%) became pregnant and 12 cases had childbrith, 2 cases had miscarriage and one case is ongoing. The side effect was observed in 1 case (2%) which experienced diarrhea but it was lost spontaneously. Conclusions: We conclude from this study that rebamipide showed relatively high tendancy of absorption and excretion in the genital organ. In infertile males who had elevated ROS in semen, by specifically inhibiting the cell damage from the antioxidation, a way to preserve sperm motility, vitality and fertilizing capacity was confirmed.

A Study of the characteristics of NOx measurement and analysis methods of the SCR system for ships (선박용 SCR 시스템 NOx 측정 및 분석 방식의 특성 연구)

  • Kim, Sung-Yoon;Lee, Young-Ho;Kim, Min;Park, Sam-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.387-392
    • /
    • 2015
  • A method for measuring and analyzing the $NO_x$ in ships is described in $NO_x$ Technical Code 2008. The analysis device, as required by the Code, has been to use a Chemi-luminescence detection method or Heated Chemi-luminescence detection. on the other hand, selective catalytic reduction using $NH_3$ as a reducing agent has an interference effect on the analyzer, and causes measurement error. In this study, the Chemi-luminescence detection method was examined according to how it affects the concentration of $O_2$, CO, $SO_2$, $NH_3$. Fourier transform infrared spectrometry analysis equipment and measurement methods were compared. In order to confirm the effect of the physical interference of the measuring device, it was confirmed by decomposing a measuring device. Consequently, white precipitate and moisture were generated inside the chemiluminescence detection system and I found that affecting interference. The influence of interference highlights the need to consider the minimized $NO_x$ measurement method.