• 제목/요약/키워드: chemical-enhanced backwashing

검색결과 6건 처리시간 0.021초

UF pretreatment at elevated temperature within the scheme of hybrid desalination: Performance and environmental impact

  • Agashichev, Sergey;Kumar, Jayesh
    • Membrane and Water Treatment
    • /
    • 제8권3호
    • /
    • pp.279-292
    • /
    • 2017
  • This study was aimed at ultrafiltration (UF) as a pretreatment before reverse osmosis (RO) within the scheme of hybrid reverse osmosis-multistage flush (RO-MSF) desalination. Seawater at elevated temperature (after MSF heat-exchangers) was used as a feed in this process. The pretreatment system was represented as a set of functionally-linked technological segments such as: UF filtration, backwashing, chemical- enhanced backwashing, cleaning, waste disposal, etc. The process represents the sequences of operating cycles. The cycle, in turn, consists of the following unit operations: filtration, backwashing and chemical-enhanced backwashing (CEB). Quantitative assessment was based on the following indicators: normalized permeability, transmembrane pressure, specific energy and water consumption, specific waste generation. UF pre-treatment is accompanied by the following waste streams: $W1=1.19{\times}10$ power of $-2m^3$ (disposed NaOCl with 0.0044% wt.)/$m^3$ (filtrate); $W2=5.95{\times}10$ power of $-3m^3$ (disposed $H_2SO_4$ with 0.052% wt.)/$m^3$(filtrate); $W3=7.26{\times}10$ power of $-2m^3$ (disposed sea water)/$m^3$ (filtrate). Specific energy consumption is $1.11{\times}10$ power of $-1kWh/m^3$ (filtrate). The indicators evaluated over the cycles with conventional (non-chemical) backwashing were compared with the cycles accompanied by CEB. A positive impact of CEB on performance indicators was demonstrated namely: normalized UF resistance remains unchanged within the regime accompanied by CEB, whereas the lack of CEB results in 30% of its growth. Those quantitative indicators can be incorporated into the target function for solving different optimization problems. They can be used in the software for optimisation of operating regimes or in the synthesis of optimal flow- diagram. The cycle characteristics, process parameters and water quality data are attached.

Multi-bore PSf 중공사막의 내화학성 및 세척 효율 특성평가 (Evaluation of Chemical Resistance and Cleaning Efficiency Characteristics of Multi bore PSf Hollow Fiber Membrane)

  • 임광섭;김태한;장재영;남상용
    • 멤브레인
    • /
    • 제30권2호
    • /
    • pp.138-148
    • /
    • 2020
  • 본 연구는 (주)퓨어엔비텍에서 제조한 multi-bore 형태의 중공사 막을 이용하여 오염된 원수의 투과 후 오염된 막의 재사용을 위해 화학적 세정효율에 대해 파악하고자 하였으며 이를 위해 제조된 중공사 막의 재료는 내화학성이 좋은 PSf(polysulfone) 소재를 사용하였다. 실험은 소혈청 알부민(BSA)을 이용한 내오염성 평가 및 염기성 용액인 차아염소산나트륨(NaOCl), 산성 용액인 구연산(citric acid)을 이용해 장기 함침하여 내화학성 평가를 진행하였다. 시간에 따른 수투과도와 인장강도를 측정하여 분리막의 기계적 강도와 성능의 감소에 대한 결과를 관찰하였다. 이후 소혈청 알부민으로 오염된 막의 화학적 용액에 따른 역세척 후 회복효율을 파악하였다. PSf 중공사 막은 뛰어난 내화학성을 가졌으며 화학적세척결과 차아염소산나트륨의 효율이 높음을 확인하였다.

MBR 공정에서 수온에 따른 막오염 및 CEB 세정효율 특성 (Characterization of membrane fouling and CEB (Chemical enhanced backwashing) efficiency with temperature in SMBR Process)

  • 박기태;박정훈;최은혜;김형수;김지훈
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.389-395
    • /
    • 2017
  • In this paper, we investigate the characteristics of membrane fouling caused by water temperature in the Membrane bioreactor(MBR) process and try to derive the membrane fouling control by chemical enhanced backwashing(CEB). The extracellular polymeric substances(EPS) concentration was analyzed according to the water temperature in the MBR, and the membrane fouling characteristics were investigated according to the conditions, with sludge & without sludge, through a lab-scale reactor. As shown in the existing literature the fouling resistance rate was increased within sludge with the water temperature was lowered. However, in the lab-scale test using the synthetic wastewater, the fouling resistance increased with the water temperature. This is because that the protein of the EPS was more easily adsorbed on the membrane surface due to the increase of entropy due to the structural rearrangement of the protein inside the protein as the water temperature increases. In order to control membrane fouling, we tried to derive the cleaning characteristics of CEB by using sodium hypochlorite(NaOCl). We selected the condition with the chemicals and the retention time, and the higher the water temperature and the chemical concentration are the higher the efficiencies. It is considered that the increasing temperature accelerated the chemical reaction such as protein peptide binding and hydrolysis, so that the attached proteinaceous structure was dissolved and the frequency of the reaction collision with the protein with the chemical agent becomes higher. These results suggest that the MBRs operation focus on the fouling control of cake layer on membrane surface in low temperatures. On the other hand, the higher the water temperature is the more the operation strategies of fouling control by soluble EPS adsorption are needed.

완속모래여과 공정에서 세라믹 MF 막의 적용 (Application of Ceramic MF Membrane at the Slow Sand Filtration Process)

  • 최광훈;박종율;김수한;김정숙;강임석
    • 대한환경공학회지
    • /
    • 제35권12호
    • /
    • pp.877-882
    • /
    • 2013
  • 최근 음용수를 위한 UF, MF 막의 적용이 증가하고 있다. UF/MF 막은 재래식 수처리 공정에 비하여 원수 수질 변화에도 안정적인 운전이 가능하고 부지 면적이 작으며 자동화 운전이 가능하다는 장점을 가지고 있다. 현재 대부분의 UF/MF 막시설은 고분자 막을 사용하고 있다. 최근 세라믹 막은 고분자막에 비하여 경쟁력이 있다고 알려지고 있다. 세라믹 막은 높은 투과유량과 약품세정 빈도가 작으며 막의 수명 또한 길어 최근 적용 사례가 증가하고 있다. 따라서 본 연구는 MF 세라믹 막 pilot plant를 완속모래여과 정수장에 적용하였다. 본 연구에 사용된 세라믹 Pilot plant는 3개의 계열이 있으며, 각 계열별로 원수와 모래 여과수를 막의 유입수로 각각 사용하였다. 또한 세라믹 막 공정의 최적화를 위하여 전처리 응집공정으로서 PACl 응집제를 사용하였다. 그리고 화학세정(Chemical Enhanced Backwashing, CEB)은 황산 (500 mg/L)과 차아염소산 (200 mg/L)을 1.5일에 1번씩 모든 계열에 주입하여 이루어졌다. 본 연구 결과 세라믹 막 공정의 전처리 응집공정에서 최적의 응집제 사용은 막의 유입수로 원수와 모래 여과수에 대한 막의 flux를 크게 증가시켰다. 또한 본 연구에서 사용된 최적 응집제 주입량에서 차압상승률은 원수(25 mg/L)의 경우 2.173 kPa/cycle이며, 모래 여과수(5 mg/L)의 경우 0.301 kPa/cycle으로 나타났다.

UF와 디스크필터를 전처리시설로 이용한 역삼투압해수담수설비의 평가 (Evaluation of Seawater Reverse Osmosis Desalination System with UF and Disk Filter as Pre-Treatment)

  • 양근모;임동훈;김준하;정형호
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제1권1호
    • /
    • pp.59-68
    • /
    • 2013
  • 본 연구에서는 한외여과막과 역삼투압막으로 이루어진 해수담수화장치를 구성하였다. 해수를 취수하여 디스크필터와 한외여과막을 이용한 전처리설비를 통과시켜 생산한 전처리수의 $SDI_{15}$와 탁도를 측정하여 역삼투압해수담수설비에 적합함을 밝혔다. 역삼투압해수담수설비의 부산물인 브라인을 전처리수와 혼합하여 역삼투압해수담수설비의 입구농도를 변화시켰다. 농도 변화실험에서, 해수농도가 역삼투압해수담수설비의 성능에 끼치는 영향을 실험으로 구하였다. 염배제율, 회수율, 생산수의 수질은 입구농도에 따라 많은 변화가 있었으며, 에너지소비량도 입구농도에 거의 선형적으로 상승하는 것을 실험으로 구하였다.

하수재이용 막여과 운영 효율 향상 (Improvement of membrane operation for wastewater reuse)

  • 장동일;김재훈;이상수;김경택;한봉석;하금률
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.327-327
    • /
    • 2021
  • 하수재이용에서 전처리 막여과 공정은 완벽한 고액분리로 인해 후단 역삼투막 손상을 줄일 수 있는 공정으로 각광을 받고 있다. 일반적으로 막여과 공정은 여과->물리세정->충진->여과 와 같은 제막사에서 제공하는 운전 사이클에 맞춰 적용하고 있으며 유지세정 역시 1회/일 또는 1회/주 단위로 정해진 범위에서 수행되고 있다. 이러한 운전 방식은 시시각각 변화하는 막 유입수질에 적절하게 대응하지 못해 장기적으로 막오염 발생에 따른 생산수량 감소는 물론 막오염 제거를 위한 화학세정 주기가 짧아져 전체적인 생산수량이 감소하는 원인이 되고 있다. Raffine(2012)에 따르면 가역적 막오염의 경우 Flux 증가에 큰 영향이 없으나 비가역적 막오염은 Flux 증가에 따라 급격히 증가한다고 보고하고 있으며 이는 제한된 분리막 면적당 처리수 생산량을 증가시키기 위해 비가역적 막오염의 발생량을 줄이는 것이 필요하며 이를 위해 주기적인 강화역세(Chemical Enhanced Backwashing, CEB)가 도입되고 효율적인 유지세정 방법에 대한 연구가 진행되고 있다. 당사에서는 일산에 있는 I 수질복원센터내에 25 m3/일 규모의 막여과 하수재이용 파일롯 플랜트를 설치하고 막여과 하수재이용 공정의 운영 효율을 높이기 위하여 W사에서 개발한 IntelliFluxControl(IFCr) 소프트웨어를 이용하여 하수재이용 막여과 성능을 확인 하였다. IFCr은 실시간으로 변화하는 수질에 따른 막오염 정도에 따라 역세 강도 및 빈도와 CEB 적용 정도를 변화시켜 분리막 운전의 효율을 높일 수 있는 운영 소프트웨어이다. I 수질복원센터의 하수 방류수를 막여과 유입수로 적용하여 40 LMH를 기준으로 IFCr을 적용하지 않은 경우 23.7일 운전 가능하였으나 IFCr을 적용한 경우 50일 연속 운전이 가능하였다. 또한 역세척수를 운전 기간 동안 약 50 m3을 사용한 반면 IFCr을 적용한 경우 이에 절반 수준인 24.1 m3 만 사용하여 회수율이 91%에서 95%로 증가한 것을 확인 할 수 있었다. 본 연구의 결과는 기존의 제막사에서 제시하는 막 공정 운영방법을 탈피하여 분리막이 갖고 있는 성능을 최대한 끌어 올릴 수 있는 연구 결과라고 판단되며 향후 스케일 업 연구를 통해 실제 플랜트에 적용 가능성이 확인 될 경우 시설의 설치 막모듈 개수와 유지관리비를 동시에 절감할 수 있는 기술이 될 수 있을 것이다

  • PDF