• Title/Summary/Keyword: chemical damage

Search Result 1,207, Processing Time 0.027 seconds

Investigation of the Knocking Phenomenon in SI Engines (가솔린 엔진에서의 노킹 현상 해석)

  • Min, Kyoung-Doug
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.2
    • /
    • pp.29-35
    • /
    • 2000
  • Knock in SI engines causes physical damage to the piston and combustion chamber and lowers the thermal efficiency. The increase in compression ratio which can improve the thermal efficiency and engine performance has been limited by engine knock. So the need of making clear the knocking phenomenon has increased. This paper reviews the methods of knock detection, characterization and prediction of knock with the reduced chemical kinetic modeling.

  • PDF

A Development of Expert System for the Estimated Maximum Loss of Vapor Cloud Explosion (증기운 폭발시의 예상최대손실 산정을 위한 전문가 시스템 개발)

  • 김원철
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.37-42
    • /
    • 1996
  • The assessment of catastrophic accidents such as BLEVE, vapor cloud explosion, and toxic material releases in the chemical process industries(CPI) shall be carried out according to the Requirement of PSM/SMS enforced by Korea Government Agencies, but reasonable models are not proposed for the practical application. The traditional models, TNT Equivalency Model, are well-known and helpful for the assessment of vapor cloud explosion. However, the estimated-damage-area using the traditional model has much more deviations comparing to the real damage caused by vapor cloud explosion suffered before. These are why an expert system for the assessment of vapor cloud explosion has been developed, which is based on theoretical, statistical and experimental data, and it would be helpful for CPI to evaluate the damage-area in case of vapor cloud explosion.

  • PDF

electrical Damage of Metallized Film Capacitors (필름 Capacitor의 전기적Damage에 관한 연구)

  • ;Chathan M. Cooke
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.574-581
    • /
    • 1991
  • Damage in film capacitors has been investigated, using FTIR and ESCA, aiming to elucidate the nature of electrode removal and the possibility of base films to be damaged. Also, tests were conducted to investigate the effect of a long-term thermal aging at elevated temperatures. Unsuccessful clearing or grape-clustering processes can induce a long-term degradation which involves the chemical and morphological changes. Major changes are the oxidation and the decrease in surface crystallinity possibly arising from the corona discharge. An immediate deterioration of BOPP film may occur when the air entrapped between the film layers induces an extensive autocatalytic oxidative degradation. This type of immediate damage may result in a premature failure at an early stage of qualification test. As far as the nature of electrode removal is concerned, a permanent removal of electrode materials was observed in the main erosion area.

  • PDF

Long Range Cylindrically Guided Ultrasonic Wave Technique for Inspection

  • Balasubramaniam, Krishnan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.364-371
    • /
    • 2003
  • In this paper, a review of the current status, on the use of long range cylindrically guided wave modes, and their interaction with cracks and corrosion damage in pipe-like structures will be discussed. Applications of cylindrically guided ultrasonic wave modes have been developed for inspection of corrosion damage in pipelines at chemical plants, flow-accelerated corrosion damage (wall thinning) in feedwater piping, and circumferential stress corrosion cracks in PWR steam generator tubes. It has been demonstrated that this inspection technique can be employed on a variety of piping geometries (diameters from 1 in. to 3 ft, and wall thickness from 0.1 to 6 in.) and a propagation distance of 100 meters or more is sometimes feasible. This technique can also be used in the inspection of inaccessible or buried regions of pipes and tubes.

Melatonin as an Antioxidant (항산화제로서 Melatonin)

  • Kim, Seok-Joong;Russel J. Reiter
    • Proceedings of the Korean Journal of Food and Nutrition Conference
    • /
    • 2000.05a
    • /
    • pp.13-20
    • /
    • 2000
  • Melatonin, a chemical mediator produced in the mammalian pineal gland and several other organ, is a ubiquitously acting antioxidant. It has been shown to scavenge the hydroxyl radical (ㆍOH), singlet oxygen ($^1$O$_2$) and the peroxynitrite anion (ONOO-). In addition, melatonin reportedly stimulates a number of antioxidative enzymes including glutathione peroxidase, glutathione reductase and glucose-6-phosphate dehydrogenase. Antioxidative effect of melatonin in pharmacological and physiological level was investigated using hepatocarcinogen 2-nitropropane (2-NP) and pinealectornized (Px) rats, respectively. Lipid peroxidation (LPO) as indicated by malondialdehyde and 4-hydroxyalkenals and DNA damage as indicated by 8-hydroxydeoxyguanosine (8-OH-dG) induced by 2-NP were prevented by melatonin. The degree of LPO and DNA damage in Px rats were higher than those of intact old and young ones suggesting the removal of pineal gland resulted in higher accumulation of oxidative damage.

  • PDF

Non-contact damage monitoring technique for FRP laminates using guided waves

  • Garg, Mohit;Sharma, Shruti;Sharma, Sandeep;Mehta, Rajeev
    • Smart Structures and Systems
    • /
    • v.17 no.5
    • /
    • pp.795-817
    • /
    • 2016
  • A non-contact, in-situ and non-invasive technique for health monitoring of submerged fiber reinforced polymers (FRP) laminates has been developed using ultrasonic guided waves. A pair of mobile transducers at specific angles of incidence to the submerged FRP specimen was used to excite Lamb wave modes. Lamb wave modes were used for comprehensive inspection of various types of manufacturing defects like air gaps and missing epoxy, introduced during manufacturing of FRP using Vacuum Assisted Resin Infusion Molding (VARIM). Further service induced damages like notches and surface defects were also studied and evaluated using guided waves. Quantitative evaluation of transmitted ultrasonic signal in defect ridden FRPs $vis-{\grave{a}}-vis$ healthy signal has been used to relate the extent of damage in FRPs. The developed technique has the potential to develop into a quick, real time health monitoring tool for judging the service worthiness of FRPs.

Long-Term Performance of Geosynthetic Reinforcement Materials with Field Installation Condition

  • Jeon, Han-Yong;Mok, Mun-Sung;Cho, Seong-Ho;Byun, Sung-Weon;Lee, Joon-Seok
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.305-306
    • /
    • 2003
  • In the case of the geosynthetics usage to soil structure, there are some damages by compaction. And these damages by the installation compaction result in the unexpected changes of short and long term properties of the structure. So in the case of index test, there are some problems to the exact evaluation on the installation damage. Therefore, to the more definite evaluation on the installation damage of geosynthetics, the real site installation damage test is encouraged. (omitted)

  • PDF

The Effect of Mushroom Extracts on Carbon Tetrachloride-Induced Hepatotoxicity in Rats (버섯 추출물이 사염화탄소 유발 간손상에 미치는 영향)

  • 김건희;한혜경
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.2
    • /
    • pp.326-332
    • /
    • 1998
  • The effect of mushroom extracts from Pleurotus ostreatus and Lentinus edodes on carbon tetrachloride(CCl4)-induced hepatotoxicity was investigated. Rats were administered orally each mushroom extract at the dose of 150mg/kg, foolwed by treatment with CCl4. Liver damage was produced in male Sprague-Dawley rats, after 21hrs from dosing with CCl4(0.25ml/kg) which were given intraperitoneally. Liver damage without renal injury was confirmed by measuring plasma enzyme, creatinine and blood analysis and liver analysis. Plasma aminotransferase activity, and levels of cholesterol and triglyceride were analyzed. Plasma alanine aminotransferase and aspartate aminotransferase activities were decreased by 34% and 61.5% in pretreatment group of Lentinus edodes compared with CCl4 treated group, respectively. The adminstration of all mushroom extracts led the plasma cholesterol and triglyceride levels decrease more than the CCl4-treated rats. These results suggest that Lentinus edodes extract protect liver from damage induced by CCl4.

  • PDF

Antioxidant Activities of Various Extracts of Hovenia dulcis Thunb Fruits

  • Hu, Weicheng;Lee, Kab-Yeon;Wang, Myeong-Hyeon
    • Korean Journal of Plant Resources
    • /
    • v.23 no.3
    • /
    • pp.207-213
    • /
    • 2010
  • Hovenia dulcis Thunb fruits were successively extracted with hot water, water, methanol, ethyl acetate, and chloroform. The crude extracts were investigated for potential antioxidant by measuring scavenging against DPPH free radicals, reducing power, superoxide radicals, and protection of protein damage and cultured cells from a lethal dose of hydrogen peroxide ($H_2O_2$). In all chemical assays used, the hot water extract of H. dulcis fruits, which contained $61.14{\pm}2.57$ (Tannic acid mg/g extract, n=3) of total phenolic compounds contents exhibited highest activity in in vitro models of DPPH free radical scavenging activity, reducing power assay, superoxide radical scavenging activity and protection of protein damage. In addition, the hot water extract protected cultured RAW 264.7 macrophages from a lethal dose of $H_2O_2$ and reduced reactive oxygen species level in RAW 264.7 cells.

Hydraulic Runner Design Method for Lifetime

  • Sabourin, Michel;Thibault, Denis;Bouffard, David-Alexandre;Levesque, Martin
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.301-308
    • /
    • 2010
  • Quest for reliability of hydraulic runners is a concern for all mature electricity producers. The fatigue damage caused by dynamics loads is frequently the root cause of runner failure. This paper presents the damage tolerance approach based on fracture mechanics as the method chosen by Alstom and Hydro-Qu$\acute{e}$bec to predict effects of damage on runner lifetime and consequently to be use as a design method. This is sustained by a research on fracture mechanics properties of runner materials and by recommendations on the strategy to define a safety margin for design. The acquired knowledge permits to identify potential improvement of the runner lifetime without significant cost increase, like being more specific on some chemical composition or heat treatment.