• Title/Summary/Keyword: chemical balance study

Search Result 247, Processing Time 0.024 seconds

A-OPTIMAL CHEMICAL BALANCE WEIGHING DESIGN WITH CORRELATED ERRORS

  • Ceranka, Bronislaw;Graczyk, Malgorzata
    • Journal of applied mathematics & informatics
    • /
    • v.16 no.1_2
    • /
    • pp.143-150
    • /
    • 2004
  • In this paper we study the estimation problem of individual weights of objects using an A-optimal chemical balance weighing design. We assume that in this model errors are correlated and they have the same variances. The lower bound of tr$(X'G^{-1}X)^{-1}$ is obtained and a necessary and sufficient condition for this lower bound to be attained is given. There is given new construction method of A-optimal chemical balance weighing design.

Estimation of Source Contribution for PM10 by Chemical Mass Balance(CMB) in Busan

  • Jeon, Byung-Il;Lee, Young-Mi
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.359-364
    • /
    • 2008
  • PM10 samples were collected from July 2007 to Oct. 2007 at Gwaebopdong(inland area) and Dongsamdong(coastal area), in Busan. This paper investigates the contribution of emission sources to PM10 mass in Busan. Source apportionment results derived from the chemical mass balance(CMB) method. A source profiles applied in this study is organized to minimize the collinearity among sources type via statistical method. Source profiles applied in this study utilized a measured value of fine particle directly sampled from metropolitan area such as Seoul and Incheon, After a CMB modeling, sulfate and nitrate related sources among those contributing to PM10 in Busan showed high contribution by 36.53% in Gwaebopdong and 42.02% in Dongsamdong.

A Study on the Quality Assuranc of Chemical Analysis Data of Precipitation Samples (강수 분석자료의 신뢰성 검토에 관한 연구)

  • 강공언
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.85-98
    • /
    • 1995
  • In order to ensure that all major cations and anions were accurately measured, the quality assurance checks of chemical analysis data by considering ion and conductivity balance of each precipitation sample were performed. To check the quality assurance of chemical analysis data, precipitation samples were collected by wet- only precipitation sampler at Seoul site and their chemical components were analyzed. By checking the problems for the screening methods of chemical analysis data used until recently, the f value expressed as the ratio of the sum of cations and anions equivalent concentration( $\Sigma $C/$\Sigma $A ) was found to be not ap priorate for data screening. Also, the scattering plot between cation and anion equivalent concentrations in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a set of samples of various concentration levels.4 more appropriate value was therefore required, h value is defined as (A-C)/C for C≥A and ( A-C)/A for C<4. This value was showed to check the ion balance in a viewpoint of quantitative as well as qualitative and to be useful in applying this expression to a measurement data set. However, the standard o( data screening must vary in response to the ion concentration of sample. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance evaluating by h value and the electrical conductivity. As these quality assurance checks were applied to Seoul data serf 67 valid samples were obtained. The result of statistical summary in the analytical parameter of precipitation samples collected for a certain period was found to be computed in the precipitation volume- weighted mean( VWM) rather than the arithmetic mean( AM), but PH In the VWM of hydrogen ion concentration. The annual VWM of pH values was 5.0(4.9 ∼ 5.1).

  • PDF

A Study on Heat and Mass Balance in a Coal Gasifier (석탄 가스화기 열 및 물질정산에 관한 연구)

  • Kim, Bong-Keun;Yoo, Jeong-Seok;Kim, You-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.424-428
    • /
    • 2007
  • In the current most tool using heat and mass balance in a coal gasifier is dependent on commercial code such as STANJAN, CHEMKIN. However, in order to keep the self-reliance technology, it is necessary to develop the original design tool available for comprehension and analysis on the spot. So in this study, its own heat and mass balance program is developed on the assumption that the process in a coal gasifier is adiabatic and quasi-equilibrium. The mass balance is calculated by using the chemical equilibrium principle. Also the heat and mass balance according to main operating factors such as temperature, pressure and O2/Coal ratio, was carried in this tool. This heat and mass balance was verified on the basis of the results simulated in STANJAN, commercial codes using similar logic.

  • PDF

Interpretation of Analytical Data of Ion Components in Precipitation, Seoul (서울 地域 降水中 이온成分 分析資料의 解析)

  • 강공언;이주희;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.323-332
    • /
    • 1996
  • Precipitation samples were collected by the wet-only sampling method at Seoul from September 1993 to June 1995. Sample were analysed for the anions $(NO_3^-, NO_2^-, SO_4^{2-}, Cl^-, and F^-)$ and cations $(Na^+, K^+, Ca^{2+}, Mg^{2+}, and NH_4^+)$ in addition to pH and electric conductivity. In order to establish the chemical analysis data of high quality, the assurance checks for analytical data of precipitation were performed by considering the ion balance and by comparing the measured conductivity with the calculated conductivity. As we applied the various assurance checking methods by the ion balance used until recently to a data set measured in this study, the f value expressed as $\Sigma C/\Sigma A$ was found to be not appropriate for the data screening. Also, the scattering plot between cations and anions in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a data set of samples of various concentration levels. The h value defined as (A-C)/C for C $\geq$ A and (A-C)/A for C < A was used to check the ion balance. However, the standard of data screening by h value must very in response to total ion concentration of samples. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance of evaluating by h value and the conductivity balance. Further the quality control was achieved by these quality assurance methods. As the result, 67 samples among total 77 were obtained as valid. As the central tendency value for a statistical summary in the analytical parametr of samples, the volume-weighted mean value was found to represent more the general chemistry of precipitation rather than the arithmetic mean. The volume-weighted mean pH was 5.0 and 25% of samples was less than this mean. The concentrations of sufate and nitrate in precipitation were 90.4 ueq/L and 32.4 ueq/L which made up 59% and 21% of all anions. The raion of $SO_4^{2-}/(NO_3^- + NO_2^-)$ in precipitation was 2.7, which indicates that the contributions of $H_2SO_4$ and $HNO_3$ to the acidity of precipitation are 70% and 30%, respectively.

  • PDF

Simplified modeling of slide-fed curtain coating flow

  • Jung Hyun Wook;Lee Joo Sung;Hyun Jae Chun;Kim See Jo;Scriven L. E.
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.4
    • /
    • pp.227-233
    • /
    • 2004
  • Simplified model of slide-fed curtain coating flow has been developed and tested in this study. It rests on the sheet profile equations for curtain thickness in curtain flow and its trajectory derived by the integral momentum balance approach of Higgins and Scriven (1979) and Kistler (1983). It also draws on the film profile equation of film thickness variation in flow down a slide. The equations have been solved in finite difference approximation by Newton iteration with continuation. The results show that how inertia (Rey­nolds number), surface tension (capillary number), inclination angle of the slide, and air pressure difference across the curtain affect sheet trajectory and thickness profile. It has been revealed that approximate models can be useful to easily analyze coating flow dynamics without complex computations, giving qualitative agreement with full theory and with experiment.

Calculation of Mass-Heat Balance on the Iodine Crystallizer for SI Thermochemical Hydrogen Production Process (SI 열화학 수소 생산 공정 요오드 결정화기 열-물질 수지 계산)

  • Lee, Pyoung Jong;Park, Byung Heung
    • Journal of Institute of Convergence Technology
    • /
    • v.5 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • SI thermochemical hydrogen production process achieves water splitting into hydrogen and oxygen through three chemical reactions. The process is comprised of three sections and one of them is HI decomposition into $H_2$ and $I_2$ called as Section III. The production of $H_2$ included processes involving EED for concentrating a product stream from Section I. Additionally an $I_2$ crystallization would be considered to reduce burden on EED by removing certain amount of $I_2$ out of a process stream prior to EED. In this study, the current thermodynamic model of SI process was briefly described and the calculation results of the applied Electrolytes NRTL model for phase equilibrium calculations was illustrated for ternary systems of Section III. We calculated temperature and heat duty of an $I_2$ crystallizer and heat duty of heaters using UVa model and heat balance equation of simulation tool. The results were expected to be used as operation information in optimizing HI decomposition process and setting up material balance throughout SI process.

Purity assignment of 17β-estradiol by mass balance method

  • Lee, Hwa-Shim;Oh, Kwang-Hoon
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.226-233
    • /
    • 2017
  • In general, quantitative chemical analysis in various areas including food, the environment, in vitro diagnostics, etc., requires traceability in order to increase the reliability of the measurements. Measurement traceability is a property of an unbroken chain of comparisons relating an instrument's measurements to SI units. Purity analysis is the first process for establishing traceability to SI units in chemical measurements. The purpose of this study is to develop and validate a method of purity assignment for establishing the traceability of $17{\beta}$-estradiol measurements in an in vitro diagnostics field. The establishment of this method is very important as it can be applied to the development of CRM and to the analysis of the purity of other hormones. The method of assignment of the purity of $17{\beta}$-estradiol was developed using the mass balance method and was validated through participation in an International comparison. In the mass balance method, impurities are categorized into four classes as follows: total related structure impurities, water, residual organic solvents, and nonvolatiles/inorganics. In this study, total related structure impurities were characterized by a gas chromatography-flame ionization detector (GC-FID) and a high-performance liquid chromatography-ultraviolet (HPLC-UV) detector, water content was determined by a Karl-Fisher coulometer, and total residual solvents and nonvolatiles/inorganics were checked simultaneously by thermogravimetric analysis (TGA). The purity of the $17{\beta}$-estradiol was 985.6 mg/g and the expanded uncertainty was 2.1 mg/g at 95% confidence. The developed method can be applied to the development of certified reference materials, which play a critical role in traceability.

Modeling, simulation and structural analysis of a fluid catalytic cracking (FCC) process

  • Kim, Sungho;Urm, Jaejung;Kim, Dae Shik;Lee, Kihong;Lee, Jong Min
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2327-2335
    • /
    • 2018
  • Fluid catalytic cracking (FCC) is an important chemical process that is widely used to produce valuable petrochemical products by cracking heavier components. However, many difficulties exist in modeling the FCC process due to its complexity. In this study, a dynamic process model of a FCC process is suggested and its structural observability is analyzed. In the process modeling, yield function for the kinetic model of the riser reactor was applied to explain the product distribution. Hydrodynamics, mass balance and energy balance equations of the riser reactor and the regenerator were used to complete the modeling. The process model was tested in steady-state simulation and dynamic simulation, which gives dynamic responses to the change of process variables. The result was compared with the measured data from operating plaint. In the structural analysis, the system was analyzed using the process model and the process design to identify the structural observability of the system. The reactor and regenerator unit in the system were divided into six nodes based on their functions and modeling relationship equations were built based on nodes and edges of the directed graph of the system. Output-set assignment algorithm was demonstrated on the occurrence matrix to find observable nodes and variables. Optimal locations for minimal addition of measurements could be found by completing the whole output-set assignment algorithm of the system. The result of this study can help predict the state more accurately and improve observability of a complex chemical process with minimal cost.

A study on the Gasifier Modeling using a Chemical Equilibrium (화학평형을 이용한 가스화기 모델링에 관한 연구)

  • 정근모;임태훈;오인환;박명호
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.276-284
    • /
    • 1993
  • This study is to obtain some basic data which are prerequisite for the conceptual design of gasification process based on entrained-bed type gasifier. The Gibbs free energy minimization method is used to analyze the chemical equilibrium in the gasifier. The modeling results which consider the conventional mass balance and heat balance are compared with the experimental data published by Electric Power Research Institute. The analysis shows that the reaction in a entrained-bed gasifier is influenced mainly by the amount of oxidant, by the temperature of gasifier and by the type of coals.

  • PDF