• Title/Summary/Keyword: chemical agent detector

검색결과 9건 처리시간 0.312초

화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발 (Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment)

  • 가동하
    • 한국군사과학기술학회지
    • /
    • 제23권3호
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

비접촉 화학작용제 검출기의 MCT 광검출기를 위한 적분기 기반의 리드아웃 회로 구현 (Realization of Readout Circuit Through Integrator to Average MCT Photodetector Signals of Noncontact Chemical Agent Detector)

  • 박재현
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.115-119
    • /
    • 2022
  • A readout circuit for a mercury-cadmium-telluride (MCT)-amplified mid-wave infrared (IR) photodetector was realized and applied to noncontact chemical agent detectors based on a quantum cascade laser (QCL). The QCL emitted 250 times for each wavelength in 0.2-㎛ steps from 8 to 12 ㎛ with a frequency of 100 kHz and duty ratio of 10%. Because of the nonconstant QCL emission power during on-duty, averaging the photodetector signals is essential. Averaging can be performed in digital back-end processing through a high-speed analog-to-digital converter (ADC) or in analog front-end processing through an integrator circuit. In addition, it should be considered that the 250 IR data points should be completely transferred to a PC during each wavelength tuning period of the QCL. To average and minimize the IR data, we designed a readout circuit using the analog front-end processing method. The proposed readout circuit consisted of a switched-capacitor integrator, voltage level shifter, relatively low-speed analog-to-digital converter, and micro-control unit. We confirmed that the MCT photodetector signal according to the QCL source can be accurately read and transferred to the PC without omissions.

UV 화염감지기의 감지성능에 대한 분진분위기의 영향 (Influence of Dust Environment on the Detection Capability of Ultraviolet Flame Detector)

  • 김홍;호예
    • 한국가스학회지
    • /
    • 제1권1호
    • /
    • pp.113-119
    • /
    • 1997
  • UV 화염감기의 분진분위기에서의 성능저하를 고찰하기 위하여 세제분말, 탄진 및 분말 소화약제의 분진운을 형성하였고 LPG 및 가솔린 화염을 사용하여 UV 화염감지기의 감지성능을 고찰하였다. 분진 분위기 하에서의 UV 화염감지기의 성능을 분진의 농도와 분진층의 거리가 증가함에 따라 뚜렷한 증가를 보였으며, 분진의 화학적, 물리적 특성에 커다란 영향을 받았다. 따라서 UV 화염감지기를 분진 분위기에서 사용한 경우 특별한 주의를 기울일 필요가 있는 것으로 사려된다.

  • PDF

DNA Ligand - Redox Active Molecule Conjugates as an Electrochemical DNA Probe

  • Ihara, Toshihiro;Maruo, Voshiyuki;Uto, Yoshihiro;Takenaka, Shigeori;Takagi, Makoto
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.887-894
    • /
    • 1995
  • Toward the development of universal, sensitive, and convenient method of DNA (or RNA) detection, two kinds of electrochemically active DNA ligands. acridine - viologen and oligonucleotide - ferrocene conjugate, were prepared. Thermodynamic and electrochemical study revealed that these probes bound strongly to DNA, and showed a typical cyclic voltammograms, indicating a potential for use as a reversible electrochemical labelling agent for DNA. Especially, using the electrochemically active oligonucleotide, we have been able to demonstrate the detection of DNA at femtomole levels by HPLC equipped with ordinary electrochemical detector (ECD). These results lead to the conclusion that the redox-active probes are very useful for the microanalysis of nucleic acid due to the stabilily of the complexes, high detection sensitivity, and wide applicability to the target structures (single- and double strands) and sequences.

  • PDF

비접촉식 화학작용제 탐지용 라만 분광계를 위한 Denoising Autoencoder 기반 잡음제거 기술 (Denoising Autoencoder based Noise Reduction Technique for Raman Spectrometers for Standoff Detection of Chemical Warfare Agents)

  • 이창식;유형근;박재현;김휘민;박동조;장동의;남현우
    • 한국군사과학기술학회지
    • /
    • 제24권4호
    • /
    • pp.374-381
    • /
    • 2021
  • Raman spectrometers are studied and developed for the military purposes because of their nondestructive inspection capability to capture unique spectral features induced by molecular structures of colorless and odorless chemical warfare agents(CWAs) in any phase. Raman spectrometers often suffer from random noise caused by their detector inherent noise, background signal, etc. Thus, reducing the random noise in a measured Raman spectrum can help detection algorithms to find spectral features of CWAs and effectively detect them. In this paper, we propose a denoising autoencoder for Raman spectra with a loss function for sample efficient learning using noisy dataset. We conduct experiments to compare its effect on the measured spectra and detection performance with several existing noise reduction algorithms. The experimental results show that the denoising autoencoder is the most effective noise reduction algorithm among existing noise reduction algorithms for Raman spectrum based standoff detection of CWAs.

GC/AED를 이용한 의료용 액화혼합가스 중 산화에틸렌 및 프레온 가스류의 몰분율 측정 (Determination of the mole fractions of ethylene oxide and freons in medical liquefied gas mixture by GC/AED)

  • 김현주;김달호;임아랑;이택홍;김진석
    • 분석과학
    • /
    • 제25권6호
    • /
    • pp.382-387
    • /
    • 2012
  • 산화에틸렌($C_2H_4O$, Ethylene oxide, EtO)은 에탄올아민 같은 공업적으로 중요한 물질이나 에틸렌 글리콜의 생산 원료 또는 살균제로 이용되는 물질이다. 산화에틸렌은 불화탄화수소를 분사제 또는 바탕가스로 하여 액화혼합가스로 제조되어 열에 약한 의료기기나 저장시설의 소독에 널리 사용되고 있다. 액화혼합가스의 생산 및 사용 시 품질관리 및 안전관리를 위해 각 성분의 몰분율을 정확히 측정할 필요가 있다. 휘발성 액체시료 중 각 기체성분들은 증기압이나 끓는점 등과 같이 물리 화학적 성질이 다르므로 몰분율 측정 시 실린더 내부의 상층에 평형을 이루고 있는 기체시료 또는 하층의 기화되지 않은 액체시료를 직접 측정기기에 주입하는 방법에 따라 측정 결과가 다를 수 있다. 본 연구에서는 액화혼합가스를 액체 또는 기체 상태로 주입할 수 있는 새로운 온라인 시료도입장치를 고안하고 GC/AED (gas chromatograph-atomic emission detector)를 사용하여 산화에틸렌과 불화탄화수소 액화혼합가스를 측정하였으며 AED의 검출특성, 기기에 주입 시 시료의 상태, 측정파장에 따른 측정결과의 정확성 및 반복성을 조사하였다.

N-propyl-N,N-dimethylethanolamine의 Phantom에서 Laser Induced Fluorescence의 스펙트라에 관한 연구 (A Study on Spectra of Laser Induced Flourescence in Phantom of N-propyl-N,N-dimethylethanolamine)

  • 김기준;이주호;이주엽;성완모
    • 한국응용과학기술학회지
    • /
    • 제32권2호
    • /
    • pp.330-338
    • /
    • 2015
  • N-propyl-N,N-dimethylethanolamine의 산란혼탁매질에서 형광, 산란과 응집의 영향은 파장 과 산란된 형광세기로 나타내는데, laser induced fluorescence(LIF) 분광학에 의한 분자특성으로 나타난다. 산란매질에서 광학적 효과는 광학적 파라미터들(${\mu}_s$, ${\mu}_a$, ${\mu}_t$)에 의해 표현되고 응집은 고-액상 분리 공정에서 중요하게 활용되고 있다. 따라서 입자가 서로 접근될 때 콜로이드 입자들의 상호작용을 LIF와 응집효과로 분석하였다. Monte Carlo simuation과 실험으로 레이저 광원에서 검출기까지 거리의 함수에 의해 농도가 묽어짐에 따라 산란세기가 기하급수적으로 감소함을 알 수 있었다. 이는 유지화학, 생의학, 레이저 의학, 의공학 분야적용에 LIF와 입자이동 현상은 아주 적합한 모델 연구에 큰 도움이 될 것이다.

일부 대체세정제 제조업체의 물질안전보건자료의 실태와 그 화학물질의 유해성 평가에 관한 연구 (Survey of Actual Conditions of Material Safety Data Sheet and Quantitative Risk Assessment of Toxic Substances : Substitutes for Degreasing Agents)

  • 윤종국;전태원;정진갑;이명희;이상일;차상은;유일재
    • 한국산업보건학회지
    • /
    • 제10권2호
    • /
    • pp.18-26
    • /
    • 2000
  • Since the regulation of MSDS (Material Safety Data Sheets) had started from July 1996, employers were required to furnish MSDS for the chemicals in use in their workplace. However, many MSDS did not contain upright information for the chemicals, and they were not updated regularly, and were not written in the standard format required by the Industrial Safety and Health Act (ISHA). The purposes of this study were 1) to examine the reliability of MSDS for mixed solvents, 2) to provide reliable MSDS to employers or employees, 3) to find out any difficulties in implementing MSDS after the initiation, and 4) to promote regular MSDS updating and to ensure the reliability of MSDS for chemical manufacturers. To check the reliability of MSDS of mixed chemicals, 21 samples of mostly degreasing solvents were collected along with their MSDS from the work place. The samples were analyzed by gas chromatography-mass selective detector(GC-MSD). Their components were classified as saturated hydrocarbon, cyclic hydrocarbon, aromatics, and halogen containing hydrocarbon, and the amount of each class were measured. Manufacture's MSDS were compared with the actual composition of the collected samples, and further examined the reliability by checking whether the chemicals analyzed were included in the MSDS correctly. Finally, each item of MSDS was evaluated whether the MSDS correspond to the regulation required by ISHA. The results were following: 1) most of the degreasing solvents in MSDS were incorrect in their composition and contents, 2) the information in the MSDS including hazard classification, exposure level, toxicity, regulatory information were incorrectly provided, and 3) some MSDS did not disclose carcinogens in their MSDS. Continuous monitoring of MSDS was required to ensure reliability of MSDS. The Chemicals containing hydrocarbons from C10-C15 need to be tested to provide toxicity data. In addition, governmental support for providing correct MSDS was recommended to ensure reliability of MSDS. The MSDS regulation relating to the confidential business information may need to be revised to ensure reliability of MSDS.

  • PDF