• 제목/요약/키워드: charge neutralization

검색결과 46건 처리시간 0.028초

"Charge Neutralization for Deposit Control"

  • Buikema, Peter D.
    • 펄프종이기술
    • /
    • 제29권3호
    • /
    • pp.87-94
    • /
    • 1997
  • As the paper market becomes more and more competitive, more mills will want to switch to alkaline papermaking to take advantage of the Vowing demand. Many papermakers have tried to do this without success in the past much like the American papermakers did in the late 1970's. The Problem is that runnability Problems occur, drainage slows, Presses pick drying becomes more difficult and sheet quality suffers as a result Sheet holes and breaks occur, and runnability becomes a real operating problem. Converting to alkaline papermaking is not as simple as turning off the alum. We must be aware of the numerous factions that alum served at acid pH and provide alkaline alternatives. It is the purpose of this paper to discuss methods of deposit control via charge neutralization and system control at alkaline pH. This article explains the concept as well as the measurement and control. The resultant benefits are seen in runnability, quality and profitability for the papermaker.

  • PDF

Charge Determination of Humic Acid and Humic Extract by Spectrophotometry

  • Kam Sang Kyu;Cho Eun Il
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제2권2호
    • /
    • pp.139-148
    • /
    • 1998
  • The charge densities of humic acid and humic extract have been determined by back titration using spectrophotometry as the method of end point detection and several cationic polymers of different charge density(copolymers of acylamide and dimethylaminoethylacrylate and polydiallyidimethylammonium chloride, PDDA), and a cationic indicator o-toluidine blue(o-Tb). The charge densities of humic acid and humic extract obtained depend on the charge densities of cationic polymers used. When the polymers of lower charge density are used, lower apparent charge density values are obtained, but for polymers of high charge density(above 2.5 meq/g), the measured values are almost identical, but also are nearly the same as that obtained for PDDA which has a high charge density(about 6 meq/g). For polymers of lower charge density, it is considered that the optimum dosage does not correspond to 1 :1 charge neutralization between anionic and cationic groups. Polymers of high charge density should be used in order to achieve a complete charge neutralization. As humic acid and humic extract are dissociable acids, their ionization is heavily pH dependent and so higher charge density values are obtaines with increasing pH.

  • PDF

응집 현상에 따른 오염물질 제거 및 입자 형태 특성: Alum을 사용한 경우 (Pollutant Removal and Characteristic of Floc by Alum Coagulation)

  • 문병현;김승현;이향인
    • 대한환경공학회지
    • /
    • 제22권7호
    • /
    • pp.1263-1271
    • /
    • 2000
  • Alum을 이용한 응집 과정에서 탁도 및 유기물 제거와 응집 floc의 특성을 파악하였다. 본 실험에서 구한 탁도 제거영역을 Amitharajah의 연구결과와 비교했을 때 sweep floc 및 charge neutralization의 제거영역이 낮은 pH 영역으로 이동하였는데 그 원인은 원수에 포함된 유기물 농도가 다른데서 찾을 수 있다. 대체적으로 탁도 및 유기물($UV_{254}$와 TOC)의 제거영역은 비슷하였으나 탁도 제거에 비해 낮은 pH에서 유기물 제거의 효과가 높았다. Floc의 특성은 AIA, SALLS 방법을 이용하여 volume diameter과 fractal dimension을 측정하였다. AIA 방법에 비해 SALLS 방법의 측정이 용이하고 신뢰성도 높았다. SALLS 방법을 이용하여 floc을 측정한 결과 sweep floc 영역의 floc이 charge neutralization 영역의 floc 보다 fractal dimension과 평균 직경이 크게 측정되었으며, 오염물질의 제거율이 높을수록 floc의 fractal dimension과 평균 직경도 크게 나타났다.

  • PDF

Comparison of Flocculati on-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Sang-Kyu Kam;Lee
    • 한국환경과학회지
    • /
    • 제1권2호
    • /
    • pp.137-144
    • /
    • 1992
  • Flocculation-spectrophotometry and streaming current detector( SCD ) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the formal. and was determined with the dosage required during charge neutralization of humic acid for the latter It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humid acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density, Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF

Comparison of Flocculation-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Kam Sang-Kyu;An Lee-Sun;Lee Min-Gyu
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제1권2호
    • /
    • pp.137-144
    • /
    • 1997
  • Flocculation-spectrophotometry and streaming current detector(SCD) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the former and was determined with the dosage required during charge neutralization of humic acid for the latter. It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humic acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density. Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF

Comparison of Flocculation Characteristics of Humic Acid by Inorganic and Organic Coagulants: Effects of pH and Ionic Strength

  • Xu Mei-Lan;Lee Min-Gyu;Kam Sang-Kyu
    • 한국환경과학회지
    • /
    • 제14권8호
    • /
    • pp.723-737
    • /
    • 2005
  • The effects of pH (5, 7 and 9) and ionic strength of different salts on the flocculation characteristics of humic acid by inorganic (alum, polyaluminum chloride (PAC) with degree of neutralization, r=(OH/Al) of 1.7) and organic (cationic polyelectrolyte) coagulants, have been examined using a simple continuous optical technique, coupled with measurements of zeta potential. The results are compared mainly by the mechanisms of its destabilization and subsequent removal. The destabilization and subsequent removal of humic acid by PAC and cationic polyelectrolyte occur by a simple charge neutralization, regardless of pH of the solution. However, the mechanism of those by alum is greatly dependent on pH and coagulant dosage, i.e., both mechanisms of charge neutralization at lower dosages and sweep flocculation at higher dosages at pH 5, by sweep flocculation mechanism at pH 7, and little flocculation because of electrostatic repulsion between negatively charged humic acid and aluminum species at pH 9. The ionic strength also affects those greatly, mainly based on the charge of salts, and so is more evident for the salts of highly charged cationic species, such as $CaCl_2$ and $MgCI_2.$ However, it is found that the salts have no effect on those at the optimum dosage for alum acting by the mechanism of sweep flocculation at pH 7, regardless of their charge.

Ion Induced Secondary Electron Emission of MgO with Patterned Gold Line Charge Neutralization

  • Lee, Jong-Wan;Lee, Kie-Young;Kim, Hong-Gyu;Ahn, Joon-Hyung;Jung, Won-Joon;Yoon, Sean-J;Byungdu Oh
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제5권1호
    • /
    • pp.7-10
    • /
    • 2001
  • Ion induced secondary electron emission coefficients γ of protecting layers of an AC plasma display panel(AC-PDP) have been measured. In order to solve the surface charging effect during the measurement at insulating samples like MgO, a new method with the patterned gold line charge neutralization has been introduced. The measurement was performed at the samples, MgO and MgO+MgF$_2$, which showed a great difference in the firing voltage between the two protecting layers. The γ value has been compared with the firing voltage Vf of the AC-PDP with the same protecting layer. Correct relationship between γ and Vf has been observed. Thus, the patterned gold line method has been proven to be successful for the measurement of the secondary electron emission yield at insulator sample surfaces.

  • PDF

유동 대전된 절연유의 제전 방식중 침전극 삽입의 영향(II) (The Effect of Needle Electrode in the Static Charge Elimination Methods for Streaming-Electrification Insulating Oil)

  • 조영규;김용운;임현찬;김두석;신용덕;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.624-626
    • /
    • 1993
  • The Electrical Charge generated by friction in flowing insulating oil can create hazadous accidents. Neutralization of static charges in the oil during transportation is an obvious method of overcoming the problem of internal electric charge. It is known that SCR(Static Charge Reducer) can neutralize much of this charge by the needle electrode and mixing it with the original charge. In our experiment, a filter to generate static charge was set just befor a measurement pipe, and streaming current from the filter to the earth $I_s$, current from the electrode to the earth $I_e$ and current from the receiving tank to the earth $I_f$ were measured in a steady state. As a result, charge density and needle electrode current increases with increasing of oil temperature. Charge elimination rate decreases with increasing of oil flow rate, and increases with increases of oil temperature. Faraday Cage current decreases with increasing of oil temperature.

  • PDF

PACI을 이용한 오염물질 제거 및 입자 특성에 관한 연구 (Pollutant Removal and Characteristic of Floc by PACI Coagulation)

  • 문병현;김승현;이향인
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.459-468
    • /
    • 2000
  • This study is to investigate the floc structure and removal of turbidity and organic matter by PACI coagulation. The turbidity removal by PACI coagulation was obtained at larger pH range than alum coagulation. And the removal of organic matter was obtained at smaller pH range than that of turbidity. The organic matter was removed by the adsorption of $Al(OH)_3$ precipitates. Floc structure was characterized by measuring fractal dimension and volume diameter using AIA and SALLS. Fractal dimension measured by AIA did not show the different characteristics of floc produced in sweep floe and charge neutralization region. Using SALLS, floes in sweep floc region were found to be larger size and fractal dimension than flocs in charge neutralization region. As pollutant removal increased. larger fractal dimension and size of floc were measured. SALLS method was found to be more useful method to characterize flocs in coagulation than AIA method.

  • PDF

Crossflow 방식 응집-정밀여과 공정의 케이크층 저감 메커니즘 (Cake Reduction Mechanism in Coagulation-Crossflow Microfiltration Process)

  • 김수한;박희경
    • 상하수도학회지
    • /
    • 제17권4호
    • /
    • pp.519-527
    • /
    • 2003
  • Cake layer in crossflow microfiltration(CFMF) can be reduced by coagulation, enhancing membrane flux. This is because enlarging particle size by coagulation increases shear-induced diffusivity and the back-transport of rejected particles. However it is known that the enlarged particles are disaggregated by the shear force of the pump while passing through it. This study is to look at the disaggregation in relation with cake layer reducation. Kaolin and polysulfon hollow fiber microfilter are used for experiment. The reduction of cake resistance by coagulation is observed in a range of 17% to 53% at the various coagulation conditions. The particle size analysis results of the experiments show that aggregated particles in feed are completely disaggregated by pump but re-aggregation of particles occurs in membrane. This suggestes that the re-aggregation of particles is critical to cake reduction and flux enhancement, since the aggregated particles are completely broken. The mechanisms for re-aggregation in membrane are the same with those for coagulation in feed tank. Charge neutralization is better for CCFMF than sweep flocculation although it has two drawbacks in operation.