• 제목/요약/키워드: charge distribution

검색결과 702건 처리시간 0.027초

Enzymatic Extraction of Lemon Pectin by Endo-Polygalacturonase from Aspergillus niger

  • Contreras-Esquivel, Juan C.;Voget, Claudio E.;Vita, Carolina E.;Espinoza-Perez, J.D.;Renard, Catherine M.G.C.
    • Food Science and Biotechnology
    • /
    • 제15권2호
    • /
    • pp.163-167
    • /
    • 2006
  • Pectin was enzymatically extracted from industrial lemon pomace by using an endo-polygalacturonase from Aspergillus niger as a processing aid and compared to pectin extraction by hot hydrochloric acid. The yield of pectin was 17.6 and 20.2% with enzymatic and acidic treatments, respectively. The molecular weight distribution did not vary greatly between the samples extracted with enzyme or acid. Large differences in charge density were observed, however, when the samples were analyzed by anionic-exchange chromatography. Pectin extracted by the enzymatic treatment indicated higher charge density than that obtained by hydrochloric acid. The higher charge density could due to the presence of endogenous lemon pectinesterase, which was activated at low pH 4.5 in situ conditions during the process of enzymatic extraction, leading to low methoxylated pectin with a higher charge density.

점토광물을 이용한 완효성비료의 개발 및 응용에 관한 연구-I. 점토광물의 특성 (A Study on the Development and Application of Slow Releasing Fertilizer using Korean Natural Clay Minerals-I. Characterization of Korean Natural Clay)

  • 박중철;최진호;박권우
    • 한국환경농학회지
    • /
    • 제3권2호
    • /
    • pp.50-54
    • /
    • 1984
  • K완효성 비료개발을 위해 $K^+$로 이온교환된 montmorillite를 규정하고 n-alkylammonium method에 의한 충전하 결정을 통해 그 특성을 확인하있다. 이 방법을 통해 결정내의 불균일한 전하분포를 식별하고 충전하 상하영역을 평가했다(충전하는 영일 bentonite에 국한 : ${\xi}=0.39-0.28e/(SiAl)_4O_{10}$, ${\xi}=0.34$). 그리고 층간 양이온 교환능(C.E.C.) 평균가는 0.915meq/100g임을 알았다.

  • PDF

소 혈청 알부민의 금 표면 플라즈몬 공명 칩과의 반응에 대한 pH의 영향 (Impact of pH on the response of bovine serum albumin to gold surface plasmon resonance chip)

  • 손영수
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.326-330
    • /
    • 2021
  • Reactions between gold (Au) surface plasmon resonance (SPR) chips and bovine serum albumin (BSA) dissolved in solutions of different pH were investigated. The charge on the BSA depends on the pH of the solution in which it is dissolved. Thus, dissolving BSA in different pH solutions resulted in different charges of BSA. Among the BSA dissolved in solutions with pH 4.01, 7.4, and 10.01, the SPR response was the highest for BSA dissolved in the solution of pH 4.01. To eliminate the response variation owing to the difference in the refractive indices of the solutions, phosphate buffered saline (PBS) was injected into the system after the reaction of BSA with the Au SPR chip had happened. In this case too, the BSA dissolved in the solution with pH 4.01 exhibited the highest response. This may be attributed to the non-uniform distribution of ionic patches on the BSA, which can induce electrostatic attraction to the surface even though BSA has a positive charge at pH 4.01, and the absolute values of the net charge of BSA at pH 4.01 and 7.4 were very close.

유한요소해석을 이용한 전주공정에서의 전류밀도 분포 예측 (Estimate of Current Density Distribution in Electroforming Process Using Finite Element Analysis)

  • 강대철;김헌영;전병희
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.279-284
    • /
    • 2004
  • Electroforming is the highly specialized use of electrodeposition for the manufacture of metal parts and basically a specialized form of electroplating. So, we can apply electrochemical system analysis for electroforming process. Electrochemical systems are concerned with the interplay between electricity and chemistry, namely the measurements of electrical quantities, such as current density, potential, and charge, and their relationship to chemical parameters. This paper based on the basic equations of electrics and electrochemical kinetics, was employed for a theoretical explanation of the current density distribution on electroforming process. We calculated current density distribution and potential distribution on cathode. Also, calculated current density distribution of vertical direction. It was shown that current density is related with distance of between anode and cathode and mass transfer process.

배전자동화시스템 적용을 위한 경제성 평가 (Economic Evaluation far the Application of the Distribution Automation System)

  • 홍순학;하복남;김호용;정경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.36-38
    • /
    • 1993
  • This study considers the economic aspect of the distribution automation system, which is the decision-making criteria of the electric utilities for the investment. The feeder automation candidate region is divided into two types of the urban and the rural. The total investment cost of the feeder automation for each type is estimated. The annual cost, is also estimated, by finding the fixed charge rate. To compare the annual cost and the economic effect cost, for the investment decision-making, the costs are quantitatively estimated on the following effects : the manpower replacement, the outage cost saving, the main transformer utilization improvement, the feeder utilization improvement, and the line loss reduction.

  • PDF

Application of Bond Valence Method to Estimate the Valence Charge Distributi on in the Metal-to-Oxygen Bonding Spheres in Perovskites

  • Nhat, Hoang Nam;Chau, Dinh Van;Thuong, Dinh Van;Hang, Nguyen Thi
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권1호
    • /
    • pp.75-92
    • /
    • 2015
  • This paper presents the application of the bond valence method to estimate the valence charge distribution in several perovskite systems: $La_{{\tilde{1}}x}Pb_xMnO_3$ (x=0.1-0.5), $La_{0.6}Sr_{0.{\tilde{4}}x}Ti_xMnO_3$ (x=0.0-0.25) and $La_{{\tilde{1}}x}Sr_xCoO_3$ (x=0.1-0.5); the reviewing of their crystal structures is also incorporated. The results showed the failure of the elastic bonding mechanism in all studied systems and revealed the general deficit of the valence charge in their unit cells. This valence deficit was not associated with the structural defects and was not equally localized in all coordination spheres. As the content of substitution increased, the charge deficit declined systematically from balanced level, signifying the transfer of valence charge from the ${\tilde{B}}O_6$ to ${\tilde{A}}O_{12}$ spheres. This transfer depended on the valence deviation of spheres and the average reached near 2 electron per unit cell. The possible impact of the limitted accuracy of the available structural data on the bond valence results has also been considered.

SMC 압축성형 공정에 관한 유한요소해석 (Finite Element Analysis of SMC Compression Molding Processes)

  • 이충호;허훈
    • 소성∙가공
    • /
    • 제4권3호
    • /
    • pp.204-213
    • /
    • 1995
  • A finite element program is developed to analyze the flow phenomena in SMC compression molding as a viscoplastic model. The calculation of temperature distribution is also carried out by uncoupling the thermal analysis from the flow analysis. SMC molding processes with a flat plate substructure and the one with a T-shaped rib are considered in numerical simulation. The numerical results provide deformed shapes, temperature distribution in a SMC charge, and the forming load. The simulation of compression molding of a flat plate with a T-shaped rib requires a remeshing technique for the whole process.

  • PDF

전력용 변압기의 절연유가 전계에 미치는 수치해석적 모델 (A Numerical Model of the Electric Field Distribution in Power Transformers)

  • 신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.3-6
    • /
    • 1990
  • The impact of the convected charges, which is caused by the electrification phenomina, in the oil-paper insulation systems of power transformers has been numerically investigated using FEM. The potential distribution of the oil-paper insulation system is assumed to be governed by three equations instead of the classical Laplace equation. When the charge density of oil and the conduction current are kept high, the field distortion or the interrace in a power transformer is considerably distorted due to the convected charges.

  • PDF

규격화된 분전반 제작을 위한 표준작업절차(SOP)의 공정 개발 (Process Development of a Standard Operating Procedure (SOP) for the Manufacturing of Standardized Distribution Boards)

  • 고완수;이병설;최충석
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.21-27
    • /
    • 2018
  • The purpose of this study is to develop a SOP (Standard Operating Procedure) for a distribution board that can monitor the leakage current of a load distribution line in real time. The developed distribution board was fabricated by applying IEC 61439-1. It consists of the distribution board and an alarm device. The work process for making the distribution board was compliant with the KEMC (Korea Electrical Manufacturers Cooperative) regulations. And the AC distribution board range is 1,000 V. In addition, the voltage in DC is less than 1500 V. The distribution board receives a 3-phases and 4-wires power supply system and can supply power to the load of a maximum of 32 single or three phase distribution circuits. Also, leakage current measured on the power distribution board was used by sensors installed. The SOP of the developed distribution board consists of the installation standards for the short circuit alarm device and sensor, the surge protection device, switches and indication lamps, and other devices. The operation procedure was prepared so that each manufacturing step of the distribution board must be confirmed by the persons in charge of preparation, production, quality control and approval before moving forward to the next step.

지역분배센터의 고객수요분할을 통한 다단계 분배체계 재구축에 관한 연구 (A Study on the Reconstruction of Multi-Echelon Distribution System by the Customer Demand Decomposition of Regional Distribution Center)

  • 최진영
    • 산업경영시스템학회지
    • /
    • 제20권44호
    • /
    • pp.61-68
    • /
    • 1997
  • The algorithm of customer demand decomposition suggested by this study is a reconstruction method of distribution network under the allowance of same level supply. Regional distribution center(RDC) distributes additional inventories of some of the supplying items to retailers under its charge to reduce the time needed for emergency delivery to neighborhood retailer where backlog happened. This also restrict the purpose of the inventories held by RDC as only regular supply. All of which leads to the creation of more realistic method allowing the affiliation of closing related RDC with one in the vicinity. In this study, the role of RDC is restricted only as supplying items regularity and the conruction of distribution system processing through the closing by consideration of the possibility of supplying retailers from the RDC in the vicinity is discussed.

  • PDF