• Title/Summary/Keyword: charge amplifier

Search Result 74, Processing Time 0.022 seconds

A Design and Implementation of a Prototype Microwave Power Transmission System (마이크로파 전력전송시스템의 프로토타입 설계 및 구현)

  • Park, Min-Woo;Park, Jin-Woo;Back, Seung-Jin;Koo, Ja-Kyung;Lim, Jong-Sik;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2227-2235
    • /
    • 2009
  • This paper describes the system configuration and measured performances of a wireless power transmission system which utilizes microwave. The technically final target of this system is to provide DC power to various mobile terminals within limited spaces such as buildings, conference rooms, and so on. The prototype system is built using in-house designed and fabricated circuits such as microwave oscillator, high power amplifier, microstrip patch antenna, low pass filter, and detector/rectifier. The fixed RF power of 29.3dBm at 2.4GHz is produced from the high power amplifier and transmitted through the transmitting antenna, while the received RF power at the receiving antenna is transformed into DC power through the detector/rectifier. The measured change of DC voltage according to the distance between transmitting and receiving antenna is described.

Development of Signal Processing Modules for Double-sided Silicon Strip Detector of Gamma Vertex Imaging for Proton Beam Dose Verification (양성자 빔 선량 분포 검증을 위한 감마 꼭지점 영상 장치의 양면 실리콘 스트립 검출기 신호처리 모듈 개발)

  • Lee, Han Rim;Park, Jong Hoon;Kim, Jae Hyeon;Jung, Won Gyun;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • Recently, a new imaging method, gamma vertex imaging (GVI), was proposed for the verification of in-vivo proton dose distribution. In GVI, the vertices of prompt gammas generated by proton induced nuclear interaction were determined by tracking the Compton-recoiled electrons. The GVI system is composed of a beryllium electron converter for converting gamma to electron, two double-sided silicon strip detectors (DSSDs) for the electron tracking, and a scintillation detector for the energy determination of the electron. In the present study, the modules of a charge sensitive preamplifier (CSP) and a shaping amplifier for the analog signal processing of DSSD were developed and the performances were evaluated by comparing the energy resolutions with those of the commercial products. Based on the results, it was confirmed that the energy resolution of the developed CSP module was a little lower than that of the CR-113 (Cremat, Inc., MA), and the resolution of the shaping amplifier was similar to that of the CR-200 (Cremat, Inc., MA). The value of $V_{rms}$ representing the magnitude of noise of the developed system was estimated as 6.48 keV and it was confirmed that the trajectory of the electron can be measured by the developed system considering the minimum energy deposition ( > ~51 keV) of Compton-recoiled electron in 145-${\mu}m$-thick DSSD.

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Evaluation on Insulation Performance of Traction Motors for a Hybrid Vehicle by Partial Discharge Measurement (부분방전 측정에 의한 하이브리드차량 견인전동기의 절연성능평가)

  • Park, Dae-Won;Park, Chan-Yong;Choi, Jae-Sung;Kil, Gyung-Suk;Lee, Kang-Won
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.2
    • /
    • pp.249-253
    • /
    • 2009
  • This paper dealt with the insulation evaluation by a measurement of partial discharge(PD) on traction motors used in a hybrid vehicle. The PD method has been accepted as an effective and a non-destructive. technique to evaluate insulation performance of low-voltage electric and electronic devices. In this paper, the PD measurement system which was manufactured with a coupling network, a low noise amplifier, and an associated electronics is described. The PD measurement system has the frequency bandwidth of $1[MHz]{\sim}30[MHz]$ at -3 [dB] and the stable sensitivity of 19 [mV/pC] for the traction motor. From the experimental results, discharge inception voltage (DIV) and apparent charge (q) were $1,100[V_{rms}]$ and 105 [pC] for the used motor, and $1,400[V_{rms}]$ and 84 [pC] for the new one. By comparing the DIV and q, we could evaluate the insulation condition for the traction motors.

SENSITIVITY ANALYSIS TO EVALUATE THE TRANSPORT PROPERTIES OF CdZnTe DETECTORS USING ALPHA PARTICLES AND LOW-ENERGY GAMMA-RAYS

  • Kim, Kyung-O;Ahn, Woo-Sang;Kwon, Tae-Je;Kim, Soon-Young;Kim, Jong-Kyung;Ha, Jang-Ho
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.567-572
    • /
    • 2011
  • A sensitivity analysis of the methods used to evaluate the transport properties of a CdZnTe detector was performed using two different radiations (${\alpha}$ particle and gamma-ray) emitted from an $^{241}Am$ source. The mobility-lifetime products of the electron-hole pair in a planar CZT detector ($5{\times}5{\times}2\;mm^3$) were determined by fitting the peak position as a function of biased voltage data to the Hecht equation. To verify the accuracy of these products derived from ${\alpha}$ particles and low-energy gamma-rays, an energy spectrum considering the transport property of the CZT detector was simulated through a combination of the deposited energy and the charge collection efficiency at a specific position. It was found that the shaping time of the amplifier module significantly affects the determination of the (${\mu}{\tau}$) products; the ${\alpha}$ particle method was stabilized with an increase in the shaping time and was less sensitive to this change compared to when the gamma-ray method was used. In the case of the simulated energy spectrum with transport properties evaluated by the ${\alpha}$ particle method, the peak position and tail were slightly different from the measured result, whereas the energy spectrum derived from the low-energy gamma-ray was in good agreement with the experimental results. From these results, it was confirmed that low-energy gamma-rays are more useful when seeking to obtain the transport properties of carriers than ${\alpha}$ particles because the methods that use gamma-rays are less influenced by the surface condition of the CZT detector. Furthermore, the analysis system employed in this study, which was configured by a combination of Monte Carlo simulation and the Hecht model, is expected to be highly applicable to the study of the characteristics of CZT detectors.

Development of Tactile Sensor for Detecting Contact Force and Slip (접촉력 및 미끄러짐을 감지 가능한 촉각 센서의 개발)

  • Choi Byung-June;Kang Sung-Chul;Choi Hyouk-Ryeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.364-372
    • /
    • 2006
  • In this paper, we present a finger tip tactile sensor which can detect contact normal force as well as slip. The sensor is made up of two different materials, such as polyvinylidene fluoride (PVDF) known as piezoelectric polymer, and pressure variable resistor ink. In order to detect slip on the surface of the object, two PVDF strips are arranged along the normal direction in the robot finger tip and the thumb tip. The surface electrode of the PVDF strip is fabricated using silk-screening technique with silver paste. Also a thin flexible force sensor is fabricated in the form of a matrix using pressure variable resistor ink in order to sense the static force. The developed tactile sensor is physically flexible and it can be deformed three-dimensionally to any shape so that it can be placed on anywhere on the curved surface. In addition, a tactile sensing system is developed, which includes miniaturized charge amplifier to amplify the small signal from the sensor, and the fast signal processing unit. The sensor system is evaluated experimentally and its effectiveness is validated.

Implementation of apparatus for detecting Ringer's solution exhaustion using electrostatic capacitance variation (정전용량변화를 이용한 링거액소진감지장치의 구현)

  • Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Electrostatic capacitance measurement method in a fine hose was proposed, in which two ring-type electrodes were disposed on the hose in the direction of fluid flow instead of the conventional face-to-face electrodes. With the proposed electrode structure, we realized a Ringer's solution exhaustion detector for an IV(invasive vein) injection set. On a 4 mm-diameter hose of IV set, we disposed two ring-type electrodes of 10 mm width at a distance of 5 mm each other and obtained 0.72 pF and 2.51 pF for air and 10 % dextrose Ringer's solution in the hose, respectively. The capacitance between the two electrodes varied with the hose-wraparound coverage of electrode as well as the width of electrode and the distance between the electrodes. For hose-wraparound electrode coverage of 75 %, the capacitance varied from 0.62 pF to 1.98 pF with the Ringer's solution level between the two electrodes. A charge amplifier converted the capacitance. variation into electric signal and a comparator was used to detect whether Ringer's solution was exhausted or not. The result was delivered to a host using a RF transmitter with 320 MHz carrier frequency.

Development of Fingertip Tactile Sensor for Detecting Normal Force and Slip

  • Choi, Byung-June;Kang, Sung-Chul;Choi, Hyouk-Ryeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1808-1813
    • /
    • 2005
  • In this paper, we present the finger tip tactile sensor which can detect contact normal force as well as slip. The developed sensor is made of two different materials, such as polyvinylidene fluoride(PVDF) that is known as piezoelectric polymer and pressure variable resistor ink. In order to detect slip to surface of object, a PVDF strip is arranged along the normal direction in the robot finger tip and the thumb tip. The surface electrode of the PVDF strip is fabricated using silk-screening technique with silver paste. Also a thin flexible force sensor is fabricated in the form of a matrix using pressure variable resistor ink in order to sense the static force. The developed tactile sensor is physically flexible and it can be deformed three-dimensionally to any shape so that it can be placed on anywhere on the curved surface. In addition, we developed a tactile sensing system by miniaturizing the charge amplifier, in order to amplify the small signal from the sensor, and the fast signal processing unit. The sensor system is evaluated experimentally and its effectiveness is validated.

  • PDF

Design, Fabrication and Micromachining Error Evaluation for a Surface-Micromachined Polysilicon Capacitice Accelerometer (표면미세가공기술을 이용한 수평감지방식의 정전용량형 다결정 실리콘 가속도계의 설계, 제작 및 가공 오차 영향 분석)

  • Kim, Jong-Pal;Han, Gi-Ho;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.529-536
    • /
    • 2001
  • We investigate a surface-micromachined capacitive accelerometer with the grid-type electrodes surrounded by a perforated proof-mass frame. An electromechanical analysis of the microaccelerometer has been performed to obtain analytical formulae for natural frequency and output sensitivity response estimation. A set of prototype devices has been designed and fabricated based on a 4-mask surface-micromachining process. The resonant frequency of 5.8$\pm$0.17kHz and the detection sensitivity of 0.28$\pm$0.03mV/g have been measured from the fabricated devices. The parasitic capacitance of the detection circuit with a charge amplifier has been measured as 3.34$\pm$1.16pF. From the uncertainty analysis, we find that the major uncertainty in the natural frequency of the accelerometer comes from the micromachining error in the beam width patterning process. The major source of the sensitivity uncertainty includes uncertainty of the parasitic capacitance, the inter-electrode gap and the resonant frequency, contributing to the overall sensitivity uncertainty in the portions of 75%, 14% and 11%, respectively.

Real time MTF Measurement of Copy Lenses by two-dimensional CCDs (2차원 CCD를 이용한 복사기 렌즈의 실시간 MTF 측정)

  • 조현모;이윤우;이인원;김태희;최옥식;이환규
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • Charge-coupled device(CCD) array detectors are widely used in real time modulation transfer function(MTF) measurement systems. This paper presents the characteristics of two-dimensional CCDs used in a real time MTF measurement system for copy lenses. The MTF characteristics of a copy lens measured by this equipment show different results according to the direction of shift register, shutter speed and the amplifier gain of CCDs. An object generator is fabricated to reduce the variation of MTF values for the irradiance nonuniformity in on-axis and off-axis image plane and this MTF equipment is calibrated by using a standard lens.

  • PDF