• Title/Summary/Keyword: channel condition

Search Result 1,176, Processing Time 0.025 seconds

Symbol Power Allocation and Channel Estimation Method for LR-WPAN System (LR-WPAN 시스템에서 심볼 전력 할당과 2개의 직교 코드를 사용한 채널 추정 기법)

  • Lee, Kyung-Tak;Lee, Sung-Jun;Sohn, Sung-Hwan;Kim, Jae-Moung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.11
    • /
    • pp.1-10
    • /
    • 2007
  • In this paper, we proposed channel estimation scheme for LR-UWB system which has low data rate for WPAN in IEEE 802.15.4a. At the transmitter, we proposed dynamic power level allocation depends on channel condition in specific period when we modulate signal. We use two orthogonal code to estimate channel at once. It can estimate channel more accurately by using two code which shows good correlation characteristic then it can estimate more accurately by spreading gain. Using estimated channel condition, we synchronize symbol timing of transmitted signal. Then determined power allocation scheme and channel information is transmitted to transmiter side. Finally, using these information, transmiter side change the power level of repeated pulse to adopt to channel condition. Simulation is performed under S-V channel for LR-WPAN in IEEE 802.15.4a and we compare the performance with a different type of receiver type. We use coherent and non-coherent method at the receiver. Simulation result shows us at the NLOS channal performance evaluation is greater than that of LOS channel and the result is independent of receiver type. In the NLOS channel, as the signal delay spreading is big, performance evaluation is also increased.

On the Thermal Boundary Conditions at the Interface Between the Porous Medium and the Impermeable Wall (다공성 매질과 비투과성 벽면 사이의 경계면에 대한 열적 경계 조건)

  • Kim, Deok-Jong;Kim, Seong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1635-1643
    • /
    • 2000
  • The present work investigates a heat transfer phenomenon at the interface between a porous medium and an impermeable wall. In an effort to appropriately describe the heat transfer phenomenon at the interface, the heat transfer at the interface between the microchannel heat sink, which is an ideally organized porous medium, and the finite-thickness substrate is examined. From the examination, it is clarified that the he heat flux distribution at the interface is not uniform for the impermeable wall with finite thickness. On the other hand, the first approach, based on the energy balance for the representative elementary volume in the porous medium, is physically reason able. When the first approach is applied to the thermal boundary condition, and additional boundary condition based on the local thermal equilibrium assumption at the interface is used. This additional boundary condition is applicable except for the very th in impermeable wall. Hence, for practical situations, the first approach in combination with the local thermal equilibrium assumption at the interface is suggested as an appropriate thermal boundary condition. In order to confirm our suggestion, convective flows both in a microchannel heat sink and in a sintered porous channel subject to a constant heat flux condition are analyzed. The analytically obtained thermal resistance of the microchannel heat sink and the numerically obtained overall Nusselt number for the sintered porous channel are shown to be in close agreement with available experimental results when our suggestion for the thermal boundary conditions is applied.

Finite Element Analysis for Circulation Phenomena in Sudden Expansion of Open Channel (유한요소법을 이용한 개수로단면급확대부의 순환현상해석)

  • 윤태훈;서승원
    • Water for future
    • /
    • v.21 no.1
    • /
    • pp.67-76
    • /
    • 1988
  • Analyzed was the circulation phenomena in the open channel with sudden expansion, by applying the Galerkin's finite element method to the depth-averaged 2-dimensional continuity and momentum equations. Wave tests were done in the simplified channel in order to review the validity of this newly developed model and the computed results were within 0.5% of $L_2$-norm error, and application of this model to the simulation of simplified dam-break gave very close results compared with the analytical solution, thus, it can be concluded that this model is valid and efficient. The main flow in the expanded channel was defined as a new initial condition with given velocity and the flow in the expanded portion was at rest in simulating the circulation, and besides the Neumann's condition the slip boundary condition for lateral wall was found to be proper condition than the no-slip condition. It can be concluded, from the numerical tests in the sudden expension, that the circulating phenomena depend mainly on the convective inertia and the effect of turbulence due to bottom shear and lateral shear is insignificant.

  • PDF

Symbol Error Rate Analysis for Fixed Multi-User Superposition Transmission in Rayleigh Fading Channels (레일레이 페이딩 채널에서 고정적 다중사용자 중첩 전송에 대한 심벌 오차율 성능 분석)

  • Lee, In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.10
    • /
    • pp.1379-1385
    • /
    • 2018
  • In the conventional multi-user superposition transmission, the power allocation coefficients of data symbols and the received signal processing of users are determined by the condition of instantaneous channel powers. However, the use of instantaneous channel powers can increase the system complexity. Hence, we consider fixed multi-user superposition transmission using average channel powers. The fixed multi-user superposition transmission can reduce the system complexity because it uses the condition of average channel powers that slowly change over time in order to decide the power allocation coefficients and the received signal processing. In this paper, we analyze the average symbol error rate for the fixed multi-user superposition transmission. In particular, an expression for the average symbol error rate of M-ary Quadrature Amplitude Modulation is derived assuming Rayleigh fading channels. In addition, through the numerical results, we show that the conventional and fixed multi-user superposition transmissions achieve the similar average symbol error rate performances at the user in the severe channel condition.

An Experimental Study on Pressure Loss in Straight Cooling Channels (직선형 냉각채널에서의 압력손실에 대한 실험적 연구)

  • Yoon, Wonjae;Ahn, Kyubok;Kim, Hongjip
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.94-103
    • /
    • 2016
  • A regeneratively-cooled channel in a liquid rocket engine is used to effectively cool a combustion chamber inner wall from hot combustion gas, and the heat transfer/pressure loss characteristics should be predicted in advance to design cooling channels. In the present research, five cooling channels with different geometric dimensions were designed and the channels were respectively manufactured using cutter and endmill. By changing coolant velocity and downstream pressure, the effects of manufacturing method, channel shape, and flow condition on pressure losses were experimentally investigated and the results were compared with the analytical results. At same channel shape and flow condition, the pressure loss in the channel machined by the cutter was lower than that by the endmill. It was also found that the pressure loss ratio between the experimental result and the analytical data changed with the channel shape and flow condition.

Differential Changes of ATP-sensitive Potassium Channel Current after Hypoxia-reperfusion Treatment in Mouse Neuroblastoma 2a (N2a) Cell

  • Park, Ji-Ho
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.6 no.4
    • /
    • pp.183-186
    • /
    • 2002
  • Ischemic damage is one of the most serious problems. The openers of KATP channel have been suggested to have an effect to limit the ischemic damage. However, it is not yet clear how KATP channels of a cell correspond to hypoxic damage. To address the question, N2a cells were exposed to two different hypoxic conditions as follows: 6 hours hypoxia followed by 3 hours reperfusion and 12 hours hypoxia followed by 3 hours reperfusion. As the results, 6 hours hypoxic treatment increased glibenclamide- sensitive basal $K_{ATP}$ current activity (approximately 6.5-fold at 0 mV test potential) when compared with nomoxic condition. In contrast, 12 hours hypoxic treatment induced a relatively smaller change in the $K_{ATP}$ current density (2.5-fold at 0 mV test potential). Additionally, in experiments where $K_{ATP}$ channels were opened using diazoxide, the hypoxia for 6 hours significantly increased the current density in comparison to control condition (p<0.001). Interestingly, the augmentation in the $K_{ATP}$ current density reduced after exposure to the 12 hours hypoxic condition (p<0.001). Taken together, these results suggest that $K_{ATP}$ channels appear to be recruited more in cells exposed to the 6 hours hypoxic condition and they may play a protective role against hypoxia-reperfusion damage within the time range.

Performance of a DS/CDMA Packet Network in an Indoor Wireless Infrared Channel

  • Kim, Jin-Young
    • Proceedings of the IEEK Conference
    • /
    • 2000.06a
    • /
    • pp.213-216
    • /
    • 2000
  • In this paper, performance of a CDMA-based packet transmission system is analyzed and simulated in a wireless infrared channel. The indoor wireless infrared channel is modeled as a non-directed diffuse link. The pulse position modulation (PPM) is used as a modulation scheme. From the simulation results, it is shown that the RS coding is very effective in improving the packet-delay characteristics of the CDMA-based packet transmission system. The performance improvement is more significant especially when the infrared channel is in a worse condition.

  • PDF

A SHAPE OPTIMIZATION METHOD USING COMPLIANT FORMULATION ASSOCIATED WITH THE 2D STOKES CHANNEL FLOWS

  • Kim, Hongchul
    • Korean Journal of Mathematics
    • /
    • v.16 no.1
    • /
    • pp.25-40
    • /
    • 2008
  • We are concerned with a free boundary problem for the 2D Stokes channel flows, which determines the profile of the wing for the channel, so that the given traction force is to be distributed along the wing of the channel. Using the domain embedding technique, the free boundary problem is transferred into the shape optimization problem through the compliant formulation by releasing the traction condition along the variable boundary. The justification of the formulation will be discussed.

  • PDF

The Numerical Simulation of a 8-Channel Optical Wavelength Division Multiplexer with Channel Spacing $\Delta\lambda$=0.8 nm

  • Kim, Sang-Duk;Ku, Dae-Sung;Yun, Jung-Hyun;Lee, Jae-Gyu;Kim, Jong-Bin
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.1-4
    • /
    • 2002
  • The numerical alaysis of optical device, silicabased device, are presented. The purpose of this paper is to simulate and to design a 8-channel optical wavelength division multiplexer(OWDM) based on Mach-Zehnder Interferometer(MZI) with wavelength spacing between channels Δλ=0.8 nm at central wavelength λ=1.55 ${\mu}{\textrm}{m}$. In initial condition fur simulating, we assumed as follows. A channel waveguide is made from silica based P-doped SiO2 core layers in order to coupling with a fiber easily and its core dimension was 6 ${\mu}{\textrm}{m}$$\times$6 ${\mu}{\textrm}{m}$. The core and clad index of channel waveguide were 1.455 and 1.444, separately, at λ=1.55 ${\mu}{\textrm}{m}$. Where, the separation between channel waveguides in coupling region was 3 ${\mu}{\textrm}{m}$. As a result of analysis, a group mode index of channel waveguide was 1.4498370, was gained by Hermite-Gaussian Method(HGM). Also, the channel spacing was determined by the waveguide arm length difference and was Δλ=0.8 nm as like a proposed condition. The central wavelength of a designed-multiplexer was activated about wavelength λ=1.55 ${\mu}{\textrm}{m}$, and we certificated that it can be used to 8-channel optical wavelength division multiplexer/demultiplexer.

  • PDF

Development of a Performance Prediction Method for Centrifugal Compressor Channel Diffusers

  • Kang, Jeong-Seek;Cho, Sung-Kook;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.8
    • /
    • pp.1144-1153
    • /
    • 2002
  • A hybrid performance prediction method is proposed in the present study. A channel diffuser is divided into four subregions: vaneless space, semi-vaneless space, channel, and channel exit region. One-dimensional compressible core flow and boundary layer calculation of each region with an incidence loss model and empirical correlation of residuary pressure recovery coefficient of a channel predict the performance of diffusers. Three channel diffusers are designed and tested for validating the developed prediction method. The pressure distributions from an impeller exit to the channel diffuser exit are measured and discussed for various operating conditions from choke to nearly surge conditions. The strong non-uniform pressure distribution which is caused by impeller-diffuser interaction is obtained over the vaneless and semi-vaneless spaces. The predicted performance shows good agreement with the measured performance of diffusers at a design condition as well as at off-design conditions.