• Title/Summary/Keyword: chamber pressure

Search Result 2,138, Processing Time 0.032 seconds

Optical Diagnostics of Nanopowder Processed in Liquid Plasmas

  • Bratescu, M.A.;Saito, N.;Takai, O.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.17-18
    • /
    • 2011
  • Plasma in liquid phase has attracted great attention in the last few years by the wide domain of applications in material processing, decomposition of organic and inorganic chemical compounds and sterilization of water. The plasma in liquid is characterized by three main regions which interact each - other during the plasma operation: the liquid phase, which supply the plasma gas phase with various chemical compounds and ions, the plasma in the gas phase at atmospheric pressure and the interface between these two regions. The most complex region, but extremely interesting from the fundamental, chemical and physical processes which occur here, is the boundary between the liquid phase and the plasma gas phase. In our laboratory, plasma in liquid which behaves as a glow discharge type, is generated by using a bipolar pulsed power supply, with variable pulse width, in the range of 0.5~10 ${\mu}s$ and 10 to 30 kHz repetition rate. Plasma in water and other different solutions was characterized by electrical and optical measurements. Strong emissions of OH and H radicals dominate the optical spectra. Generally water with 500 ${\mu}S/cm$ conductivity has a breakdown voltage around 2 kV, depending on the pulse width and the repetition rate of the power supply. The characteristics of the plasma initiated in ultrapure water between pairs of different materials used for electrodes (W and Ta) were investigated by the time-resolved optical emission and the broad-band absorption spectroscopy. The deexcitation processes of the reactive species formed in the water plasma depend on the electrode material, but have been independent on the polarity of the applied voltage pulses. Recently, Coherent anti-Stokes Raman Spectroscopy method was employed to investigate the chemistry in the liquid phase and at the interface between the gas and the liquid phases of the solution plasma system. The use of the solution plasma allows rapid fabrication of the metal nanoparticles without being necessary the addition of different reducing agents, because plasma in the liquid phase provides a reaction field with a highly excited energy radicals. We successfully synthesized gold nanoparticles using a glow discharge in aqueous solution. Nanoparticles with an average size of less than 10 nm were obtained using chlorauric acid solutions as the metal source. Carbon/Pt hybrid nanostructures have been obtained by treating carbon balls, synthesized in a CVD chamber, with hexachloro- platinum acid in a solution plasma system. The solution plasma was successfully used to remove the template remained after the mesoporous silica synthesis. Surface functionalization of the carbon structures and the silica surface with different chemical groups and nanoparticles, was also performed by processing these materials in the liquid plasma.

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Improvement Effect of Sibjotang on Blood Glucose and Renal Dysfunction in Type II Diabetic Mice (제2형 당뇨 마우스에서 십조탕(十棗湯)에 의한 혈당 및 신기능 부전 개선효과)

  • Yoon, Jung Joo;Lee, Yun Jung;Kim, Hye Yoom;Ahn, You Mee;Jin, Xian Jun;Hong, Mi Hyeon;Hwang, Jin Seok;Lee, Ho Sub;Kang, Dae Gill
    • The Korea Journal of Herbology
    • /
    • v.32 no.1
    • /
    • pp.15-23
    • /
    • 2017
  • Objectives : It is well known that Sibjotang (Shizaotang), traditional herbal medicine formula, regulates the body fluid blood pressure homeostasis. This study is to investigate whether Sibjotang improves diabetic renal dysfunction in type II diabetes mellitus animal model, db/db mice. Methods : The animals model were divided into three groups at the age of 8 weeks; control group (C57BLKS/J-db/m mice), diabetic group [(C57BLKS/J+Lepr)-db/db mice], and Sibjotang group [(C57BLKS/J+Lepr)-db/db mice + Sibjotang 100 mg/kg/day]. During 8 weeks of treatment, blood glucose and urinary albumin excretion were checked in metabolic chamber at 8, 12, and 16 weeks of age, respectively. Results : Body weight and food intake of diabetic group were significantly higher than control group after 8 weeks administration. However, there were not significant different between the diabetic group and Sibjotang group. Urinary albumin excretion was significantly decreased in the Sibjotang group than the diabetic group. In addition, supplementation with Sibjotang significantly lowered levels of blood glucose, insulin, and homeostatic model assessment-insulin resistance (HOMA-IR), suggesting reduced insulin resistance. The ratio of mesangial matrix/glomerular area was markedly larger in diabetic group than control group, whereas Sibjotang significantly reduced this expansion. Moreover, immunohistological study revealed that Sibjotang attenuated the increase of transforming growth $factor(TGF)-{\beta}$ expression in kidney. Conclusion : Sibjotang ameliorates diabetes-associated renal injury through the improvement of the blood glucose and insulin sensitivity, and inhibiting the $TGF-{\beta}1$ expression. Therefore, Sibjotang may be a new therapeutic formula for the treatment of diabetic-associated renal dysfunction.

Performance analysis of SNR and BER for radiation pattern reconfigurable antenna (인체 부착용 방사패턴 재구성 안테나의 SNR 및 BER 성능 분석)

  • Lee, Chang Min;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4125-4130
    • /
    • 2015
  • This paper presents the communication performance for the radiation pattern reconfigurable antenna in the wearable device measuring bio signal (temperature, blood pressure, pulse etc.) of human body. The operational frequency is 2.4 - 2.5 GHz, which covers Bluetooth communication bandwidth. The maximum gain of the antennas is 1.96 dBi. The proposed antenna is efficiently transmitting and receiving signal by generating two opposite beam directions using two RF switches (PIN diode). Also, we investigated how radiation pattern changes according to three angles ($30^{\circ}$, $90^{\circ}$, $150^{\circ}$) of Top Loading. In this paper, we measured and compared the SNR (Signal-to-Noise Ratio) and BER (Bit Error Rate) performances of the proposed antennas in the condition between an ideal environment of anechoic chamber and smart house existing practical electromagnetic interferences (Universal Software Radio Peripheral, USRP). Throughout the comparing the results of the measurement of two cases, we found that the SNR is degraded over 5dB in average and BER is increased over ten times in maximum, therefore, it is confirmed that the error rate of receiving signal is increased. The measured results of SNR and BER value in this paper able to expect the performance degrading by the interference from the electromagnetic devices.

Improvement of Light Extraction Efficiency of GaN-Based Vertical LED with Microlens Structure

  • Kwon, Eunhee;Kang, Eun Kyu;Min, Jung Wook;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.221-221
    • /
    • 2013
  • Vertical LED (VLED) has been recognized as a way to obtain the high-power LED due to their advantages [1]. However, approximately 4% of the light generated from the active region is extracted, if the light extraction from side walls and back side is neglected because of Fresnel reflection (FR) and total internal reflection (TIR) [2,3]. In this study, the optical simulation of the VLED with the various microstructures was performed. Among them, the microlens having the diameter of 3 ${\mu}m$ and the height of 1.5 ${\mu}m$ shown the best result was chosen, and then, optimized microlens was formed on a GaN template using conventional semiconductor process. Various microstructures were proposed to improve the light extraction efficiency (LEE) of the VLED for the simulation. The LEE was simulated using LightTools based on a Monte Carlo ray tracing. The microstructures with hemisphere, cone, truncated and cylinder pattern having diameter of 3 ${\mu}m$ were employed on the top layer of the VLED respectively. The improvement of the LEE by using the microstructure is 87% for the hemisphere, 77% for the cone, 53% for the truncated, 21% for the cylinder, compared with the LEE of the flat surface at the reflectance of 85%. The LEE was increased by 88% at the height of 1.5 ${\mu}m$, compared with the LEE of the flat surface. We found that the microlens on the top layer is the most suitable for increasing the LEE. In order to apply the proposed microlens on n-GaN surface, we fabricated microlens on a GaN template. A photoresist array having hexagonal-closed packed microlens was fabricated on the GaN template. Then, optimization of etching the GaN template was performed using a dry etching process with ICP-RIE. The dry etching carried out using a gas mixture of Cl2 and Ar, each having a flow rate of 16 sccm and 10 sccm, respectively with RF power of 50 W, ICP power of 900 W and chamber pressure of 2 mTorr was the optimum etching condition as shown in Fig. 2(a).

  • PDF

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

Bilateral Delayed Nonarteritic Anterior Ischemic Neuropathy Following Acute Primary Angle-closure Crisis (양안 급성 폐쇄각녹내장 환자에서 발생한 양안 지연 비동맥염 앞허혈시신경병증 1예)

  • Park, Eun Jung;Chun, Yeoun Sook;Moon, Nam Ju
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1091-1096
    • /
    • 2018
  • Purpose: We report a case of bilateral nonarteritic anterior ischemic optic neuropathy (NAION) following acute angle-closure crisis (AACC). Case summary: A 76-year-old female visited our clinic because of a 1-day history of ocular pain and vision loss in both eyes. The visual acuity was 0.02 in both eyes and her intraocular pressure (IOP) was 52 mmHg in the right eye (RE) and 50 mmHg in the left eye (LE). She had corneal edema and a shallow anterior chamber in both eyes, with 4 mm fixed dilated pupils. After decreasing the IOP with intravenous mannitol, laser iridotomy was performed. However, 2 days later, visual acuity was further reduced to finger counting at 10 cm RE and at 50 cm LE, and her optic disc was swollen. Bilateral NAION following AACC was diagnosed. One month later, visual acuity slightly improved to 0.02 RE and 0.04 LE, and the optic disc edema resolved. A small cup-disc ratio, optic disc pallor, and atrophy were observed. Humphrey visual fields demonstrated superior and inferior altitudial visual field defects in the LE, and almost total scotoma in the RE. Conclusions: AACC can be a predisposing factor for NAION, so the relative afferent pupillary defect, papilledema, and presentation of other risk factors are important clues to a diagnosis of NAION.

Refractive Error Induced by Combined Phacotrabeculectomy (섬유주절제술과 백내장 병합수술 후 굴절력 오차의 분석)

  • Lee, Jun Seok;Lee, Chong Eun;Park, Ji Hae;Seo, Sam;Lee, Kyoo Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1173-1180
    • /
    • 2018
  • Purpose: We evaluated the postoperative accuracy of intraocular lens power prediction for patients undergoing phacotrabeculectomy and identified preoperative factors associated with refractive outcome in those with primary open-angle glaucoma (POAG). Methods: We retrospectively reviewed the medical records of 27 patients who underwent phacotrabeculectomy to treat POAG. We recorded all discrepancies between predicted and actual postoperative refractions. We compared the data to those of an age- and sex-matched control group that underwent uncomplicated cataract surgery during the same time period. Preoperative factors associated with the mean absolute error (MAE) were identified via multivariate regression analyses. Results: The mean refractive error of the 27 eyes that underwent phacotrabeculectomy was comparable to that of the 27 eyes treated via phacoemulsification (+0.02 vs. -0.01 D, p = 0.802). The phacotrabeculectomy group exhibited a significantly higher MAE (0.65 vs. 0.35 D, p = 0.035) and more postoperative astigmatism (-1.07 vs. -0.66 D, p = 0.020) than the phacoemulsification group. The preoperative anterior chamber depth (ACD) and the changes in the postoperative intraocular pressure (IOP) were significantly associated with a greater MAE after phacotrabeculectomy. Conclusions: POAG treatment via combined phacoemulsification/trabeculectomy was associated with greater error in terms of final refraction prediction, and more postoperative astigmatism. As both a shallow preoperative ACD and a greater postoperative change in IOP appear to increase the predictive error, these two factors should be considered when planning phacotrabeculectomy.

Results of Cold Flow Test and Design of Injectors for Oxidizer-rich Preburner (산화제 과잉 예연소기용 분사기 설계 및 수류 시험 결과)

  • So, YoonSeok;Woo, SeongPil;Lee, Kwang-Jin;Yu, ByungIl;Kim, Jinhyung;Cho, Hwangrae;Bang, Jeongsuk;Han, YeongMin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.52-57
    • /
    • 2018
  • This paper presents the design and cold flow test results of oxidizer-rich preburner injectors for a 9 tonf-class staged combustion engine cycle. Three types of coaxial swirl injectors were designed, and 12 injectors were designed for each type. The diameters of the fuel tangential holes are identical. The diameters of the oxidizer tangential holes were varied to investigate the influence of combustion in the oxidizer-rich preburner according to the momentum ratio of the gas oxidizer generated from combustion in the injector chamber and liquid oxidizer through the cooling channel. It will be verified through a powerpack and combustion test using an oxidizer-rich preburner. In the cold flow test, the fuel flow rate and oxidizer tangential hole flow rate reached the target value based on the designed differential pressure.

A Full Scale Hydrodynamic Simulation of High Explosion Performance for Pyrotechnic Device (파이로테크닉 장치의 고폭 폭발성능 정밀 하이드로다이나믹 해석)

  • Kim, Bohoon;Yoh, Jai-ick
    • Journal of the Korea Society for Simulation
    • /
    • v.28 no.2
    • /
    • pp.1-14
    • /
    • 2019
  • A full scale hydrodynamic simulation that requires an accurate reproduction of shock-induced detonation was conducted for design of an energetic component system. A detailed hydrodynamic analysis SW was developed to validate the reactive flow model for predicting the shock propagation in a train configuration and to quantify the shock sensitivity of the energetic materials. The pyrotechnic device is composed of four main components, namely a donor unit (HNS+HMX), a bulkhead (STS), an acceptor explosive (RDX), and a propellant (BPN) for gas generation. The pressurized gases generated from the burning propellant were purged into a 10 cc release chamber for study of the inherent oscillatory flow induced by the interferences between shock and rarefaction waves. The pressure fluctuations measured from experiment and calculation were investigated to further validate the peculiar peak at specific characteristic frequency (${\omega}_c=8.3kHz$). In this paper, a step-by-step numerical description of detonation of high explosive components, deflagration of propellant component, and deformation of metal component is given in order to facilitate the proper implementation of the outlined formulation into a shock physics code for a full scale hydrodynamic simulation of the energetic component system.