• Title/Summary/Keyword: chamber method

Search Result 1,708, Processing Time 0.025 seconds

A study on the optimal conditions for latent fingerprint development using cyanoacrylate fuming method in vacuum chamber (시아노아크릴레이트 진공 훈증법에 의한 잠재지문 현출 최적화에 관한 연구)

  • Yu, Je-Seol;Jung, Jin-Sung;Lim, Seung;Park, Sung-Woo
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.164-170
    • /
    • 2012
  • Cyanoacrylate fuming mehod is effective for latent fingerprints developing on non-porous surfaces. In this study, we investigated optimal conditions for latent fingerprint development using cyanoacrylate fuming method in vacuum chamber. The effects of temperature, relative humidity, fuming method and processing time were checked throughly. The amount of evaporated cyanoacrylate was increased at higher temperature, but cyanoacrylate polymerization on the fingerprint ridge was best at $30^{\circ}C$. With a relative humidity of 40% to 50% conditions, good quality of fingerprints were developed. If a relative humidity is lower than 30% or higher than 60%, polymerization rate of cyanoacrylate monomers on the fingerprint ridge was decreased. It was identified that application of $OMEGA-PRINT^{TM}$ dispersal pad or cotton ball with sodium hydroxide fuming method in vacuum chamber was more effective than natural fuming method. We found that cyanoacrylate processing time in vacuum chamber did not have more significant than relative humidity.

An Advanced Method of Simulation and Analysis for Electromagnetic Environment on the Mobile Receiver in a Shielded Anechoic Chamber

  • Kim, Jung-Hoon;Rhee, Joong-Geun
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.4
    • /
    • pp.229-234
    • /
    • 2006
  • This paper presents an advanced method of simulation for EM(electromagnetic) environment that affects on mobile receivers. A new calibration algorithm in the process of simulation is introduced. With a proposed calibration method, the time required for simulation is reduced and this makes it possible to simulate a near-real time EM environment in a shielded anechoic chamber. EM environment data acquisition and logging techniques with GPS for simulation were developed.

Evaluation of sampling and analytical method for emission experiment of pollutants in building materials using small chamber (소형챔버를 이용한 건축자재 오염물질 방출시험방법 평가)

  • Lee, Suk-Jo;Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.344-354
    • /
    • 2005
  • This study was carried out to evaluate the performance of a small chamber sampling and analytical method for the measurement of total volatile organic compounds (TVOC) and formaldehyde (HCHO) emission from building materials. While VOC was determined by the adsorbent tube sampling and sequential thermal desorption coupled with GC/MSD analysis, formaldehyde sampled with DNPH-silica cartridge was analyzed by HPLC. Wide-range performance criteria such as repeatability, desorption efficiency, emission chamber recovery test, duplicate precision, breakthrough volume and method detection limits were investigated for the evaluation of small chamber method. The overall precision of the small chamber sampling and analytical methods was estimated within 20~30% for target compounds. In conclusion, this study demonstrated that the small chamber sampling and analytical method can be reliably applied for the measurement of building materials pollutants.

Determination of Egg Freshness and Internal Quality Measurement Using Image Analysis (계란의 신선도 결정과 영상분석을 이용한 내부품질 측정)

  • Kim, Hyeon-T.;Ko, Han-J.;Kim, Ki-Y.;Kato, K.;Kita, Y.;Nishizu, T.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.3
    • /
    • pp.166-172
    • /
    • 2007
  • Egg quality indices are related with freshness, size of air chamber, loss of weight, and viscosity of the yolk and the protein. However, since the described quality parameters require measured in a destructive way, it is not suitable to inspect the egg quality with complete enumeration. Therefore, this study was performed to investigate the potential of image analysis method for evaluation of internal egg quality. Samples of 90 fresh eggs were collected immediately after laying and stored up to 24 days. Five eggs were randomly drawn from each storage condition (packing vs unpacking) at a regular interval and loss of weight, specific gravity and size of air chamber were measured. The image analysis for nondestructive measurement of size of air chamber was also studied. Results showed that the egg weight and gravity gradually decreased with increasing of storage days, while the size of air chamber linear increased caused by evaporation of water through the shell. A relationship a between conventional method and the image analysis method for measuring the size of air chamber was developed with the correlation coefficient of 0.928. The new finding implied that image analysis might provide a useful nondestructive tool to assess internal egg quality.

A Study to Estimate Transmission Loss of HST using a Small Scale Reverberation Chamber (소형잔향실을 이용한 고속철도 차량 구조재의 투과손실 연구)

  • Kim, Tae-Min;Kim, Jeung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.1
    • /
    • pp.19-23
    • /
    • 2011
  • The method to reduce interior noise of train was being studied. To improve transmission loss of train is one of the best way to reduce interior noise. But, the estimate to transmission loss requires lots of the commercial costs. In this study, the method to estimate transmission loss of high speed train is proposed using a scale reverberation chamber. The result shows that a transmission loss estimated using small scale reverberation is similar to that using huge reverberation chamber. The transmission loss estimated based on small scale reverberation chamber can be optimal with respect to the commercial coasts.

Predictions of Fatigue Life of Copper Alloy for Regenerative Cooling Channel of Thrust Chamber (연소기 재생냉각 채널용 구리합금의 피로수명예측)

  • Lee, Keumoh;Ryu, Chulsung;Heo, Seongchan;Choi, Hwanseok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.6
    • /
    • pp.73-82
    • /
    • 2017
  • Low-cycle thermal fatigue problem resulting from multiple use of a liquid rocket engine has to be considered for the development of a reusable launch vehicle. In this study, life prediction equations suggested by previous researchers were compared as applied to various copper alloy cases to predict fatigue lives from tensile test data. The present study has revealed that among the presently considered life prediction methods, universal slopes method provides the best life prediction result for the copper alloys, and the modified Mitchell's method provides the best life prediction result for oxygen free high conductivity (OFHC) copper.

A Study on the Pressure-travel Curve of 5.56mm Rifle Obtained from the Empirical Base Pressure Factor (탄저압력계수를 이용한 5.56mm 소총의 압력-이동거리 곡선 산출)

  • Lee, Sang-Kil;Lee, Gang-Young
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.208-216
    • /
    • 2007
  • As the propellant mass is being accelerated out of the gun chamber along with the projectile, a continuous pressure gradient exists between the end of chamber and the base of the projectile. For this reason, the base pressure-travel curve is very important to design a conventional gun barrel in the interior ballistics, but it is not obtained briefly by empirical or theoretical method. In this paper, a simple relation between chamber pressure and base pressure was determined by the factor of base pressure(Cb) obtained from the experimental method. The simple relation gives a reasonable prediction for the reduction of pressure between the breech and the base of projectile owing to the axial gradient in the gun tube. The predictions have been validated by the infrared screen sensor and the PRODAS(PROjectile Design and Analysis System) for interior ballistic systems. Therefore, the base pressure-travel curve could be calculated from the chamber pressure measured by piezoelectric sensor. The base pressure-travel curve obtained from the simple relation offers initial information to gun barrel designer and is used for calculation of muzzle velocity.

A Study on the Standardization of Sample Preparation for Urine Sediment Microscopic Examination (요침사 현미경검사를 위한 표본제작의 표준화 연구)

  • Hyeok Jae LEE;Dae Heon KIM;Min-Hyeok LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.2
    • /
    • pp.135-146
    • /
    • 2024
  • Urinalysis is a fundamental diagnostic test routinely performed in clinical laboratories. We evaluated two manual microscopy methods, including a novel protocol, against the standardized chamber method. A total of 402 specimens, comprising 201 positive each for red blood cells (RBCs) and white blood cells (WBCs) by the strip test and automated urine sediment analyzer, were selected for the analysis. The correlation coefficients between the standardized chamber method and the novel protocol RBC and WBC test were both r=0.98, indicating a high degree of correlation. The pair-wise agreement rates for the same grade between these two methods were 86.1% for RBCs and 88.6% for WBCs, with rates within one grade difference of both at 99.5%. In contrast, the agreement rates between the standardized chamber method and smaller or medium-sized laboratory methods were notably lower, with the same-grade rates at 11.9% for RBCs and 13.4% for WBCs, and within one grade difference at 67.2% and 74.1%, respectively. Additional analyses using the intraclass correlation coefficient and Bland-Altman plots confirmed that the novel protocol exhibited superior agreement compared to the other three manual microscopy methods tested. Therefore, we recommend the novel protocol as a standardized procedure for urine sediment preparation, given its high correlation and agreement with the standardized chamber method.

Effect of Electric fusion Methods on Cell Fusion Rate and Embryo Development by Somatic Cell Nuclear Transfer in Korean Native Cattle(KNC) (한우 체세포를 이용한 핵이식에서 전기융합 방법이 융합율 및 배발달율에 미치는 영향)

  • 김은국;김정욱
    • Journal of Embryo Transfer
    • /
    • v.18 no.3
    • /
    • pp.171-178
    • /
    • 2003
  • This study was conducted to investigate the effect of electric fusion methods on cell fusion rate and embryo development by somatic cell nuclear transfer in Korean Native Cattle. The KNC ear cell was cultured in vitro for confluence in serum starvation condition(DMEM+0.05% FBS) for cell confluence. The zona pellucida of IVM oocytes were partially dissection using micro pipette. Ear cells were transferred into an enucleated oocyte. The reconstructed embryos were electrically fused with Zimmermann Cell Fusion Medium(ZCFM). Nuclear transfer embryos were activated with a combination of 10${\mu}{\textrm}{m}$ calcium ionophore(5 min) and 2.0mM 6-DMAP(3 hr). The activated embryos were cultured in CR1 -aa medium contains 0.3% BSA or 10% FBS at 37$^{\circ}C$, 90% $N_2$, and 5% $CO_2$in incubator for 6 days. The fusion rates were 51.6%(chamber) and 68.9%(needle), respectively and there were significantly difference between the fusion method(P<0.05). But, lysis rates were not significantly different(10.7%, 11.5%), respectively. The cleavage rates were significantly different between the chamber method(73.2%) and needle method(80.3%), respectively(P<0.05). The rates of early embryos(2∼4cells) and blastocysts of chamber and needle methods were 54.1%, 61.1% and 18.4%, 26.3% respectively, and needle method was significantly higher than chamber method(P<0.05). But, morulae formation rate were not significantly differences between the chamber(6.7%) and needle(6.2) method(P <0.05). These result suggest that electric fusion of needle method was to be profitable for nuclear transfer embryo fusion rate, blastocyst formation rate and reduce of oocyte lysis.

Combustion Stability Rating Test of Liquid Rocket Engine Thrust Chamber (액체로켓엔진 연소기 연소안정성 평가시험)

  • Ahn, Kyubok;Kim, Jong-Gyu;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.2
    • /
    • pp.60-66
    • /
    • 2014
  • As a evaluation method of combustion stability in a liquid rocket engine thrust chamber, external disturbance devices are used. In the paper, the study on pulse-gun ignition tests for a combustion stability rating test of a thrust chamber was performed. Charging volume of pulse-guns was determined by confirming the intensities of the pressure waves from the ignition tests in the cold-flow conditions. While using same injector head, combustion instabilities were not encountered during 14 hot-firing tests without pulse-guns but combustion instabilities were triggered by pulse-gun ignition during 2 hot-firing tests. The results showed that the pulse-gun ignition test could be the evaluation method and could reduce the hot-firing test number for the stability rating of a thrust chamber.