• Title/Summary/Keyword: chamber method

Search Result 1,708, Processing Time 0.035 seconds

Numerical Analysis for Linear and Nonlinear Attenuation Characteristics of Exhaust Silencer Systems (배기 소음기의 선형 및 비선형 감쇄 특성에 대한 수치해석)

  • 김종태;김용모;맹주성;류명석;구영곤
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.4
    • /
    • pp.179-189
    • /
    • 1996
  • An unstructured grid finite-volume method has been applied to predict the linear and nonlinear attenuation characteristics of the expansion chamber silencer system. In order to achieve a grid flexibility and a solution adaptation for geometrically silencer system. In order to achieve a grid flexibility and a solution adaptation for geometrically complex flow regions associated with the actual silencers, the unstructured mesh algorithm in context with the node-centered finite volume method has been employed. The present numerical model has been validated by comparison with the analytical solutions and the experimental data for the acoustic field of the concentric expansion chamber with and without pulsating flows, as well as the axisymmetric blast flowfield with open end. Effects of the chamber geometry on the nonlinear wave attenuation characteristics is discussed in detail.

  • PDF

A Study on the Simulation of Leak Flow-rate Using Isothermal Chamber (등온화용기를 이용한 누설유량 시뮬레이션에 관한 연구)

  • Ji, S.W.;Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.71-75
    • /
    • 2010
  • Leak detection technology is a challenging research until nowadays, because it has wide and various applications in industry. Furthermore pneumatic component reliability test based on ISO requires air leakage measurement. The conventional measurement methods need a complex operation and the calibration of leak detector. Tracing the history of our study, we proposed a new method for measurement of leak flow rate using isothermal chamber. In this study, propose a simulation model of isothermal chamber by infinitesimal flow -rate, such as a leak flow-rate. The effectiveness of the proposed simulation model is proved by simulation and experimental results. Base on the comparison results, proposed simulation model is good agreement with experimental results.

Spectral Evaluation of Stirring Performance in a Reverberation Chamber using the FDTD Method (유한요소 시간차분법을 이용한 레버버레이션 챔버내에서의 스터링 효과의 분석)

  • Kim, Jong-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.11
    • /
    • pp.83-88
    • /
    • 2011
  • The spectral field data on the observation planes inside a mode stirred chamber have been computed by using the FDTD method. They can describe the directional dependence of all supported modes in the reverberation chamber (RC). Correlation coefficients have been found to evaluate the stirring effects. The correlation coefficients were obtained and compared for three different sizes of stirrers and statistical uniformity was investigated.

Nonlinear Wave Transformation and Air Pressure Variation of Air-Chamber Structure (압축공기주입 구조물에 의한 비선형 파랑변형 및 공기압의 변화에 관한 연구)

  • Kim, Do-Sam;;Yang, Yun-Mo
    • Water for future
    • /
    • v.26 no.1
    • /
    • pp.71-79
    • /
    • 1993
  • Nonlinear characteristics of air pressure variation and wave transformation of a fixed air-chamber structure are discussed theoretically and experimentally. Two analytical methods(method I and II) based on the perturbation method and Green's formula are employed in order to evaluate nonlinearities by the submerged and semi-submerged air-chamber structure. Moreover, an air compression model is newly developed to estimate the dynamic air pressure in the air-chamber inside the structure, assuming the Boyle-Charles's law with adiabatic process in the air pressure variation. Theoretical values of the method I considering evanescent mode waves at an fictious boundary, are in good agreement with those of method II employing the fictious boundary which is not affected by evanescent mode waves. Both theoretical values are shown to agree well with experimental values.

  • PDF

A Study on In-Cylinder Measurement of Flame Temperature and Soot Distribution in D.I. Diesel Engine Using Tow-Color Method (이색법을 이용한 직접 분사식 디젤엔진 실린더내의 화염 분도 및 Soot 분포 측정에 관한 연구)

  • 박정규;정수훈;원영호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.42-53
    • /
    • 1999
  • Two dimensional flame temperature and KL value distribution from the luminous flame containing soot in a DI diesel engine were measured by the tow-color method using tow different wavelengths of the flame image. The combustion chamber of a DI diesel engine was visualized by elongating the piston and cylinder and the flame in the combustion chamber was photographed on a nega-color film using a high speed camera. In this study, color CCD camera was used to digitize the three color density of the film exposed to the flame and standard lamp . The accuracy of the measuring method depends on the calibration line of film made from a high temperature standard tungsten lamp. The formation and oxidization of soot in the diesel engine were studied by observing measured time history of KL factor and flame temperature . Also , effects of various shapes of combustion chamber and fuel injection on flame temperature. Also, effects of various shapes of combustion chamber and fuel injection on flame temperature and KL value distribution were examined.

  • PDF

Intelligent Dust Chamber Bag Control System using Case-Based Reasoning (사례기반 추론을 이용한 지능형 집진기 bag 제어 시스템)

  • Kim, Jung-Sook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.1
    • /
    • pp.48-53
    • /
    • 2010
  • In this paper, we develop the intelligent remote dust chamber bag control system which is combination of the advanced IT and traditional dust chamber based on event. At first, the message format is defined for the efficient dust chamber bag information transmission using power line communication. Also, we define the data types to logically model the dust chamber and the dust chamber bag, and they are logically modeled using XML and object-oriented modeling method. In addition to, we apply the case-based reasoning for showing the dust chamber bag exchange time intelligently to user at real-time using casebase, that is collected by case or case-based reasoning result, and that is described using XML.

Methods for Measurement of Methane and Nitrous Oxide Emissions from Agricultural Fields (경작지(耕作地)에서 메탄 및 아산화질소(亞酸化窒素) 배출량(排出量) 측정방법(測定方法))

  • Shin, Yong-Kwang;Kim, Kwang-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.3
    • /
    • pp.359-372
    • /
    • 1994
  • A simplified closed static chamber method was devised for measurement of methane flux from paddy fields. Compared to automatic methane measuring system(AMMS) this chamber method provides availability with moderate costs of setup and maintenance, while it also provides the time-effectiveness compared to other closed top-type chamber method. It accomodates 30 chambers within 2 hours sampling period with two persons. And it provide a rapid and accurate analysis of methane, 30-40 samples per hour. Modified method for $N_2O$ measurements provides a precise and accurate analysis of nitrous oxide without upgrading additional heating zones for gas sampling(switching) valves.

  • PDF

Measuring Methods and Their Improvement of Formaldehyde Emission from Wood-Based Panels (목질제품의 포름알데히드방출량 측정방법과 개선방안)

  • Park Byung-Dae;Park Jong Young
    • Journal of the Korea Furniture Society
    • /
    • v.15 no.2
    • /
    • pp.1-17
    • /
    • 2004
  • This paper attempted to review measuring methods of formaldehyde emission from wood-based panel products. Methods included for the discussion were desiccator methods, extraction method, and various chamber methods. First, the procedures and testing conditions of 24-hour desiccator method was critically reviewed, and an improvement of this method was proposed to meet international standards. Two different small chamber methods ($20\ell$ and $1m^3$ chamber methods) were also compared in terms of their advantages and disadvantages. In addition, the regulation levels of formaldehyde emission of wood-based composite panels were compared for different countries. The selection of a reference method of measuring formaldehyde emission of wood panel products should consider the ease of conducting test and cost required. Results should be exchangeable for different methods.

  • PDF

A Study on the Characteristics of D. I. Diesel Spray·Flame in Operating Condition (Analysis by Diffused Background Illumination Method) (운전조건에 따른 D.I. 디젤기관의 분무·화염의 특성에 관한 연구 (배경산란광그림자사진법에 의한 해석))

  • Ra, J.H.;Lee, D.B.;Ahn, S.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.30-40
    • /
    • 1995
  • Optically accessible D. I. diesel engine with a rectangular combustion chamber was constructed to visualize the behaviors of sprays and flames in the combustion camber with the close conditions of pressure and temperature in an actual engine. The behaviors of sprays and flames in the combustion chamber as the operating conditions of this engine were photographed with high speed camera by Diffused Background Illumination Method. With photographs taken by this method, behavior of spray droplets injected into the combustion chamber, ignition points, and flame propagation were observed and analyzed at a time-and space-dependent fashion.

  • PDF

Variations of Air Temperature, Relative Humidity and Pressure in a Low Pressure Chamber for Plant Growth (식물생장용 저압챔버 내의 기온, 상대습도 및 압력의 변화)

  • Park, Jong-Hyun;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.200-207
    • /
    • 2009
  • This study was conducted to analyze the variations of air temperature, relative humidity and pressure in a low pressure chamber for plant growth. The low pressure chamber was composed of an acrylic cylinder, a stainless plate, a mass flow controller, an elastomer pressure controller, a read-out-box, a vacuum pump, and sensors of air temperature, relative humidity, and pressure. The pressure leakage in the low pressure chamber was greatly affected by the material and connection method of tubes. The leakage rate in the low pressure chamber with the welding of the stainless tubes and a plate decreased by $0.21kPa{\cdot}h^{-1}$, whereas the leakage in the low pressure chamber with teflon tube and rubber O-ring was given by $1.03kPa{\cdot}h^{-1}$. Pressure in the low pressure chamber was sensitively fluctuated by the air temperature inside the chamber. An elastomer pressure controller was installed to keep the pressure in the low pressure chamber at a setting value. However, inside relative humidity at dark period increased to saturation level.. Two levels (25 and 50kPa) of pressure and two levels (500 and 1,000sccm) of mass flow rate were provided to investigate the effect of low pressure and mass flow rate on relative humidity inside the chamber. It was concluded that low setting value of pressure and high mass flow rate of mixed gas were the effective methods to control the pressure and to suppress the excessive rise of relative humidity inside the chamber.