• 제목/요약/키워드: ceramic bracket

검색결과 48건 처리시간 0.013초

도재 브라켓의 전단접착강도에 관한 실험적 연구 (IN VITRO SHEAR BOND STRENGTH OF CERAMIC BRACKETS)

  • 이승진;장영일
    • 대한치과교정학회지
    • /
    • 제22권2호
    • /
    • pp.449-474
    • /
    • 1992
  • The purpose of this study was to evaluate the in vitro shear bond strengths to enamel and the failure sites of three ceramic brackets and one metal bracket in combination with light cured orthodontic adhesive. The brackets were divided into four groups. Each ceramic bracket group had different bonding mechanisms with adhesive. Group A; metal bracket with foil-mesh base (control group) Group B; ceramic bracket with micromechanical retention Group C; ceramic bracket with chemical bonding Group D; ceramic bracket with mechanical retention and chemical bonding. Forty extracted human lower first premolars were prepared for bonding and 10 brackets for each group were bonded to prepared enamel surfaces with $Transbond^{\circledR}$ light cured ortho dontic adhesive. Twenty four hours after bonding, the Instron universal testing machine was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites, Statistical analysis of the data was carried out with ANOVA test and $Scheff\acute{e}$ test using SPSS PC+. The results were as follows. 1 . There were statistically significant differences in mean shear bond strengths of three ceramic bracket groups (p < 0.05). Shear bond strengths of group C and D were significantly higher than that of group B and shear bond strength of group C was significantly higher than that of group D. 2. Group C and D both had significantly higher shear bond strengths than metal bracket (group A), but there were no significant differences in shear bond strengths between group A and B (p < 0.05). 3. The failure sites of four bracket groups were also different. Group C and D failed primarily at enamel-adhesive interface, but group A and B failed primarily at bracket base-adhesive interface. 4. Among all ceramic bracket groups, group B was very similar to metal bracket in the aspect of shear bond strength and failure site.

  • PDF

교정용 Resin bracket의 마찰 저항력에 관한 연구 (A Study on Frictioal Resistance Force of Orthodontic Resin Bracket)

  • 이원유;임경수
    • 대한치과교정학회지
    • /
    • 제29권1호
    • /
    • pp.107-112
    • /
    • 1999
  • 성인 교정 환자가 증가됨에 따라 교정장치의 심미성이 요구되고 있다. 교정 장치의 심미적 증진을 위해 개발된 브라켓들로는 세라믹, 콤포지트 레진 브라켓, 타이타늄 브라켓등이 소개되고 있다. 콤포지트 레진 브라켓은 우수한 색상 및 투과성이 장점이나 높은 마찰력과 낮은 취성의 단점을 갖고 있다. 이러한 단점을 보완하기 위하여 최근 개발된 세라믹 또는 레진 브라켓(metal reinforced bracket)은 마찰력을 감소시키고 강도를 증가시키기 위하여 브라켓의 슬롯에 메탈을 삽입하고 있다. 그러나 지금까지 이러한 metal reinforced resin bracket(이후 MRRB)의 물성에 관한 연구가 미진하였다. 특히 이러한 브라켓과 교정용 철선의 마찰력에 관한 연구가 미흡하기에 본 연구를 시행하였다. 본 연구는 4종의 교정용 철사(.016 S-S, .0l6X.022 S-S, .016 $TMA^{\circledR}$, .0l7X.025 $TMA^{\circledR}$)와 5종의 브라켓을 사용하였다. 사용된 브라켓들로는 메탈 1종(Ormco.Co., U.S.A)자 세라믹 1종($Crystalline^{\circledR}$), 콤포지트 레진 1종(Clear Medium $Siamase^{\circledR}$), 메탈 슬롯이 삽입된 콤포지트 레진2종($Plastic^{\circledR},\;Spirit^{\circledR}$)의 마찰력을 서로 비교하여 다음과 같은 결과를 얻었다. 1. ceramic bracket과 resin bracket은 metal reinforced resin bracket과 metal bracket보다 마찰력이 유의성 있게 크게 나타났다. 2. metal reinforced resin bracket의 slot내 metal의 삽입형태에 따른 마찰력의 크기는 유의차가 없었다. 3. metal reinforced resin bracket과 metal bracket사이의 마찰력의 크기는 유의차가 없었다. 4.. 교정용 철선과 각 브라켓 비교에서 TMA, Stainless steel 순으로 마찰력이 적게 나타났다.

  • PDF

도재브라켓 접착면의 처리방식이 전단결합강도에 미치는 영향 (EFFECTS OF THE DIFFERENT CERAMIC BRACKET BASES ON SHEAR BOND STRENGTH)

  • 김진오;이기수
    • 대한치과교정학회지
    • /
    • 제24권4호
    • /
    • pp.957-967
    • /
    • 1994
  • The purpose of this study was to evaluate the effects of different bases of ceramic brackets on shear bond strength and to observe failure patterns of bracket bondings. Lower bicuspid brackets whose bases designed for the macromechanical and silane treated chemical bonding those for silane treated chemical bonding, those for micromechanical bonding, and those for macromechanical bonding were tested as experimental groups, and foil mesh-backed metal brackets as a control group. All the brackets were bonded with $Mono-Lok\;2^{(TM)}$ on the labial surface of extracted human lower bicuspids after etching the enamel with $38\%$ phosphoric acid solution for 60 seconds. The shear bond strengths were measured on the universal test machine after 24 hours passed in the $37^{\circ}C$ water bath. The gathered data were evaluated and tested by ANOVA and Duncan's multiple range test, and those results were as follows. The shear bond strengths of brackets for macromechanical and chemical bonding, those for chemical bonding, and those for micromechanical bonding were not different (p>0.05), but showed statistically higher than those of metal bracket and those of ceramic bracket for micromechanical bonding(p<0.05). The shear bond strengths of ceramic bracket for micromechanical bonding showed statistically lower than those of metal bracket(p<0.05). The enamel fractures and/or ceramic bracket fractures were observed in the cases of higher bond strength than that of metal bracket. These results supported that silane treated base of ceramic bracket show higher shear bond strength than that of metal bracket, and suggested that micromechanical form of ceramic bracket bases show higher shear bond strength than that of macromechanical form.

  • PDF

Comparison of Temperatures of the Resin Cement in Polycrystalline Ceramic Brackets Irradiated Using a Diode Laser

  • Son, Young-Tak;Son, KeunBaDa;Kim, Kyung-Min;Lee, Jae-Mok;Kim, Jin-Wook;Yu, Wonjae;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • 제14권2호
    • /
    • pp.69-78
    • /
    • 2021
  • Purpose: The primary objective of this study was to evaluate the change in the temperature of the adhesive resin in polycrystalline ceramic brackets irradiated using a diode laser at different irradiation energy levels and times. Materials and Methods: For the measurement of the temperature of the adhesive resin, it was applied at the base of the ceramic bracket, a thermocouple was placed at the center of the base surface, the bracket was placed on prepared resin specimens for light curing, and a laser was irradiated to the center of the bracket slot at 5, 7, and 10 W. For the measurement of the temperatures of the enamel under the bracket and pulp cavity, extracted premolar was fixed to a prepared mold and the ceramic bracket was bonded to the buccal surface of the premolar. The Kruskal-Wallis H test and Friedman test were used for statistical analysis. Result: At 5 W, the temperature of the adhesive resin did not reach the resin softening temperature of 200℃ within 30 seconds. At 7 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 28 seconds. At 10 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 15 seconds. During laser irradiation, the temperature of the enamel under the bracket increased by over 5℃ within 15 seconds. Conclusion: The use of diode laser irradiation for bracket debonding should be carefully considered because the pulp cavity temperature increases by over 5℃ within the irradiation time for resin thermal softening.

Metal bracket과 ceramic bracket의 전단 결합 강도와 debonding 상태에 관한 연구 (A STUDY OF THE SHEAR BOND STRENGTH OF METAL BRACKETS AND CERAMIC BRACKETS AND THE CONDITION AFTER DEBONDING)

  • 윤정진;유영규
    • 대한치과교정학회지
    • /
    • 제22권2호
    • /
    • pp.327-343
    • /
    • 1992
  • Metal brackets and ceramic brackets were bonded to natural teeth, porcelain crowns and gold crowns After stored in artificial saliva solution for 72 hours at $37^{\circ}C$, the shear bond strengths were measured by Instron and compared with them, the bonding sites and bracket bases were examined by scanning electron microscope and light optical stereomicroscope. The results were as follows: 1. The shear bond strengths of the group which metal brackets were bonded to natural teeth and the groups which ceramic brackets were bonded to natural teeth and porcelain crowns were comparable to each other, the shear bond strength of the group which metal brackets were bonded to gold crowns was significantly low. 2. The bond failed predominantly at the bracket base/adhesive interface with the bulk of adhesive remaining on enamel in the group which metal brackets were bonded to natural teeth. 3. The bond failed consistently at the crown/adhesive interface with all of adhesive remaining on the bracket babes in the group which metal brackets were bonded to gold crowns. 4. The bond failed at the enamel or crown/adhesive interface with the bulk of adhesive remaining on the bracket bases in the groups which cramic brackets were bonded to natural teeth and porcelain crowns. 5. The shear bond strengths of the groups which ceramic brackets were bonded to porcelain crowns were not affected by etching time.

  • PDF

Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique

  • Arici, Nursel;Akdeniz, Berat Serdar;Arici, Selim
    • 대한치과교정학회지
    • /
    • 제45권1호
    • /
    • pp.29-37
    • /
    • 2015
  • Objective: The coefficients of friction (COFs) of aesthetic ceramic and stainless steel brackets used in conjunction with stainless steel archwires were investigated using a modified linear tribometer and special computer software, and the effects of the bracket slot size (0.018 inches [in] or 0.022 in) and materials (ceramic or metal) on the COF were determined. Methods: Four types of ceramic (one with a stainless steel slot) and one conventional stainless steel bracket were tested with two types of archwire sizes: a $0.017{\times}0.025$-in wire in the 0.018-in slots and a $0.019{\times}0.025$-in wire in the 0.022-in slot brackets. For pairwise comparisons between the 0.018-in and 0.022-in slot sizes in the same bracket, an independent sample t-test was used. One-way and two-way analysis of variance (ANOVA) and Tukey's post-hoc test at the 95% confidence level (${\alpha}$ = 0.05) were also used for statistical analyses. Results: There were significant differences between the 0.022-in and 0.018-in slot sizes for the same brand of bracket. ANOVA also showed that both slot size and bracket slot material had significant effects on COF values (p < 0.001). The ceramic bracket with a 0.022-in stainless steel slot showed the lowest mean COF (${\mu}$ = 0.18), followed by the conventional stainless steel bracket with a 0.022-in slot (${\mu}$ = 0.21). The monocrystalline alumina ceramic bracket with a 0.018-in slot had the highest COF (${\mu}$ = 0.85). Conclusions: Brackets with stainless steel slots exhibit lower COFs than ceramic slot brackets. All brackets show lower COFs as the slot size increases.

세라믹 브라켓의 종류 및 브라켓 슬롯과 와이어 각도에 따른 마찰 저항 차이 (Frictional resistance of different ceramic brackets and their relationship to the second order angulation between bracket slot and wire)

  • 최윤정;박영철
    • 대한치과교정학회지
    • /
    • 제36권3호
    • /
    • pp.207-217
    • /
    • 2006
  • 사회 문화적 발달과 함께 심미적 요구가 증가되면서 교정 환자 수의 증가와 함께 교정 치료 중의 심미성에 대한 요구도 늘어나고 있다. 치료 중 심미성을 증진시키기 위한 목적으로 세라믹 브라켓이 개발되어 널리 사용되고 있으나 세라믹 자체의 취성(brittleness), 대합치의 마모뿐만 아니라, 임상적으로 높은 마찰 저항이 그 문제점으로 지적되고 있다. 본 연구는 세라믹 브라켓의 마찰 저항을 알아보고 그 개선방안을 찾는데 지침이 되고자 하는 목적으로 시행하였다. 연구 재료로는 마찰 저항을 줄이기 위해 금속 슬롯이 삽입된 다결정 세라믹 브라켓과 금속 슬롯이 삽우되지 않은 단결정 세라믹 브라켓과 금속 브라켓을 이용하였으며, $.019{\times}.025$ 스테인리스 와이어를 브라켓 슬롯에 대해 $0^{\circ},\;10^{\circ}$의 각도를 부여하여 만능시험기상에서 이동시켜 그때의 정적, 동적 마찰력을 측정하였다. 연구 결과, 전체적인 평균 마찰력은 금속 브라켓, 금속 슬롯이 삽입된 다결정 세라믹 브라켓, 단결정 세라믹 브라켓 순으로 증가하였다. 브라켓 슬롯과 와이어 사이의 각도가 $0^{\circ}$일 때가 $10^{\circ}$일 때에 비해서 낮은 마찰 저항을 보였으며, 브라켓 슬롯과 와이어 사이의 각도가 $10^{\circ}$일 때 단결정 세라믹 브라켓의 동적, 정적 마찰 저항은 금속 브라켓이나 금속 슬롯이 삽입된 다결정 세라믹 브라켓에 비해 유의성 있게 크게 나타났다 (p<0.05). 본 연구를 통해서 금속 브라켓에 비해 세라믹 브라켓, 특히 금속 슬롯이 삽입되지 않은 단결정 세라믹 브라켓의 마찰 저항이 높은 것을 확인할 수 있었으며, 브라켓 슬롯과 와이어간의 각도가 증가하면 마찰 저항도 커지는 것을 확인할 수 있었다. 따라서 마찰력을 줄이기 위한 세라믹 브라켓의 개발과 함께 교정 치료 시 과도한 치관 경사를 막음으로써 마찰 저항을 줄이고 심미성을 유지하면서 치료의 효율을 높이도록 해야할 것이다.

Lingual Bracket에 의한 최신 교정치료법

  • 홍윤기;소병천
    • 대한치과의사협회지
    • /
    • 제33권10호통권317호
    • /
    • pp.727-732
    • /
    • 1995
  • 최근 교정치료가 진보함에 따라 치료대상이 성인에까지 폭넓게 적용되고 교정장치에도 심미성이 요구되어지고 있다. 이러한 요구에 부응하여 bracket과 attachment의 소형화, ceramic 또는 plastic을 사용한 투명도가 높은 장치가 개발되었다. 그러나, 순측 치면에서 bracket을 장착하는 치료에 있어서는 심미성에 한계가 있다. 이러한 점에서 lingual bracket은 설측 치면에 접착함으로써 성인교정에 있어서 심미적으로 우수하다고 할 수 있다. 이에 저자들은 lingual bracket을 이용한 교정치료에 있어서 새로운 기공과정과 임상과정을 확립하였기에 소개하고, 현재 많이 사용하고 있는 Ormco사와 Dr. Fujita의 lingual bracket을 이용하여 치료한 증례를 다음의 순서로 4회에 걸쳐서 보고하고자 한다.

  • PDF

Lingual Bracket에 의한 최신 교정치료법

  • 홍윤기
    • 대한치과의사협회지
    • /
    • 제33권11호통권318호
    • /
    • pp.811-813
    • /
    • 1995
  • 최근 교정치료가 진보함에 따라 치료대상이 성인에까지 폭넓게 적용되고 교정장치에도 심미성이 요구되어지고 있다. 이러한 요구에 부응하여 bracket과 attachment의 소형화, ceramic 또는 plastic을 사용한 투명도가 높은 장치가 개발되었다. 그러나, 순측 치면에서 bracket을 장착하는 치료에 있어서는 심미성에 한계가 있다. 이러한 점에서 lingual bracket은 설측 치면에 접착함으로써 성인교정에 있어서 심미적으로 우수하다고 할 수 있다. 이에 저자들은 lingual bracket을 이용한 교정치료에 있어서 새로운 기공과정과 임상과정을 확립하였기에 소개하고, 현재 많이 사용하고 있는 Ormco사와 Dr. Fujita의 lingual bracket을 이용하여 치료한 증례를 다음의 순서로 4회에 걸쳐서 보고하고자 한다.

  • PDF

레이저를 이용한 도재 브라켓 제거 술식 후 치수의 조직학적 변화 (Histologic changes of pulpal tissue after laser-aided ceramic bracket debonding)

  • 김유정;임성훈;윤영주;박주철;김광원
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.343-349
    • /
    • 2004
  • 레이저를 이용한 브라켓 제거 술식은 발생하는 열이 국소적이며 조절 가능하고 레이저 조사와 동시에 브라켓 제거시 기구가 뜨거워지지 않으며 브라켓 디자인에 상관없이 여러 형태의 브라켓에 적용이 가능하다는 장점을 가지고 있다. 그러나 아직까지는 치아에 안전한 레이저 강도가 명확히 밝혀지지 못한 상태이다. 따라서 본 연구에서는 토끼의 중절치에 도재 브라켓을 부착한 후 Nd-YAG laser를 여러 가지 강도로 조사한 후 브라켓을 Weingart 겹자로 탈락시켜 5일이 경과한 때의 치수의 조직학적 변화에 대해 관찰한 결과 다음의 결과를 얻었다. 1. Nd-YAG 레이저의 조사 강도가 3-5W이고 조사시간이 3초인 그룹에서 도재 브라켓이 용이하게 제거되지 않았으며 조사 강도가 5W인 그룹에서 한 개의 브라켓에 결찰익면 파절이 나타났다. 이때 치수의 조직학적 검사상 비정상적인 소견은 관찰되지 않았다. 2. Nd-YAG 레이저의 조사 강도가 7-l3W이고 조사시간이 3초인 그룹에서 도재 브라켓을 쉽게 제거할 수 있었으며 브라켓의 파절양상은 보이지 않았다 이때 치수의 조직학적 검사상 경미하고 가역적인 염증 반응이 관찰되었다. 위의 소견은 모두 가역적인 변화이며 치수의 변성이나 괴사의 위험은 없었다 결론적으로 레이저를 이용하여 도재 브라켓을 제거하는 방법은 적절한 범위의 강도와 조사시간 내에서 시행되었을 때 치수의 변성이나 비가역적인 반응을 초래하지 않고 브라켓과 접착 수지의 결합력을 약화시켜 도재 브라켓의 제거를 용이하게 해주며 브라켓 제거 시 파절을 방지하여 도재 브라켓의 재활용 가능성을 높이는 방법이라 생각된다.