• Title/Summary/Keyword: central heating

Search Result 205, Processing Time 0.04 seconds

A Study of the Heating Systems used by Korean Compatriot in Russia - Focusing on Yunhaeju, Kazakhstan and Uzbekistan- (러시아에 거주하는 고려인의 난방 방식에 관한 연구 -연해주, 카자흐스탄, 우즈베키스탄을 중심으로-)

  • Lee YoungShim;Cho JaeSoon;Lee SangHae;Joung JaeKook
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.1 s.203
    • /
    • pp.145-165
    • /
    • 2005
  • In 1937, most Korean compatriot who lived in Yunhaeju moved to Kazakhstan and Uzbekistan in Central Asia following the deportation policy of Russia. Korean compatriot have kept their traditional life style for 140 years, without a deep relationship with Korea. This study examined the heating systems of Korean compatriot in Yunhaeju, Kazakhstan and Uzbekistan, Russia. A literature review and field research, based on Ethnography as a research method, was employed. The results of the research were as following: 1) Korean compatriot in Yunhaeju use a Pechika, which is a radiator that uses hot water, and a Gudul as the main heating systems, but the use of a Pechika was most common. A Pechika functions for cooking as well as for warming the house. The room with the Gudul was connected to the kitchen, so this space was used as a place for cooking and eating, for family members to meet. Many kinds of fuel, like gas and electricity, were used to power the heating systems. 2) Korean compatriot in Kazakhstan use radiators, with hot water as the main heating system, with ratio using Gudul used in this region being the highest of all the three areas. The most common fuels used for a Gudul were wood and coal, and gas was also used in cooking. The room with the Gudul was planned to be located beside the fireplace, without any walls. The people using a Gudul use that place for eating and meeting, as well as for family members to sleep. 3) The main heating system of Korean compatriot in Uzbekistan was a radiator using hot water, and those with pipes containing hot water buried under the floor were very common. The function is very similar to that of a Gudul, so most people using this type of radiator would sleep on the floor. Those people with a traditional Gudul not using them were mostly in Uzbekistan. The reason for this was that the family members had diminished, so it was hard work for elderly parents to manage an extra building containing a Gudul. Gas was the fuel generally used for heating and cooking in Uzbekistan. 4) Guduls were used in the Korean compatriot's houses in all three areas, even though they have changed in structure to adapt to the Russian life style. However, Guduls have still been functioning to maintain a traditional life style in Korean compatriot's houses for the gathering of family members.

Gas Inflow from the Central Few Hundred Parsec to the Few Parsec Regions

  • Lee, An-Sun;Kim, Sung-Soo S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.56.1-56.1
    • /
    • 2011
  • We investigate the hydrodynamics of gas clouds in the central few hundred parsecs of the Galaxy. Non-axisymmetry (elongation) of the Galactic bulge can form a reservoir of dense molecular clouds at around two hundred parsecs from the center through the X1-X2 orbit transfer, and the star formation that has been sustained for the lifetime of the galaxy can build up a nuclear bulge there. If the nuclear bulge is elongated, this again can transport the gas there down to the central few parsecs region. We perform a series of 3-D hydrodynamic simulations that consider a potential for this "nested bar", cooling/heating, star formation and supernova feedback, and estimate the efficiency of the gas inflow down to the central parsec region.

  • PDF

A Study on the Maintenance Cost Estimation Model of the Apartment Housing (공동주택의 관리비 추정모델 연구)

  • Lee, Kang-Hee;Yang, Jae-Hyuk;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.59-67
    • /
    • 2010
  • The maintenance cost plays a important role to plan the scale of the apartment housing such as a number of household, building area and building type. Therefore, it is required to forecast the cost considering various maintenance characteristics. The maintenance characteristics are floor area, number of household, heating type, site area and etc.. In addition, the maintenance cost are classified into 5 area. These are a personal expense, facility maintenance cost, energy and water cost, insurance and sanitary cost. These five cost area are related with various characteristics and brought up the estimation model using the stepwise multiple regression analysis. The energy and heating cost share over the 50% in the total cost and the personal expense cost shares about 40%. The personal expense cost per area is 5,272 won/$m^2{\cdot}yr$ irregardless of heating type and the district heating type is a higher cost than other type. In facility maintenance cost, the central heating type is 2,015 won/$m^2{\cdot}yr$ and higher than other type. The estimation models have good statistics in each model. Most of the model have a determination coefficient over 0.7 and Durbin Watson value between 1.5 and 2.5.

Experimental Study for Influence of Summertime Heat Sources and Basic States on Rossby Wave Propagation (여름철 열원과 기본장이 로스비 파동전파에 미치는 영향에 대한 실험 연구)

  • Kim, Seong-Yeol;Ha, Kyung-Ja;Yun, Kyung-Sook
    • Atmosphere
    • /
    • v.20 no.4
    • /
    • pp.505-518
    • /
    • 2010
  • We investigated the impacts of the diabatic heating location, vertical profile and basic state on the Rossby wave propagation. To examine the dynamical process of individual responses on the regional heat source, a dry version of the linear baroclinic model was used with climatological summertime (JJA) mean basic state and vertical structure of the diabatic heating for 1979-2008. Two sets of diabatic heating were constructed of those positioned in the mid-latitudes (Tibetan Plateau, eastern Mediterranean Sea, and the west-central Asia) and the tropics (the southern India, Bay of Bengal, and western Pacific). It was found that using the principal component analysis, atmospheric response to diabatic heating reaches to the steady state in 19th days in time. The prescribed mid-latitude forcing forms equivalent barotropic Rossby wave propagation along the westerly Asia jets, whereas the tropical forcing generates the Rossby wave train extending from the tropics to mid-latitudes. In relation to the maximum vertical profile, the mid-level forcing reveals a stronger response than the lower-level forcing, which may be caused by more effective Rossby wave response by the upper-level divergent flow. Under the different sub-seasonal mean state, both of the tropical and mid-latitude forcing induce the different sub-seasonal response intensity, due to the different basic-state wind.

Design of Control System for All-Metal Domestic Induction Heating Considering Temperature and Quick-Response (워킹코일 온도 및 제어 속응성을 고려한 All-Metal Domestic Induction Heating 제어 시스템 설계)

  • Park, Sang-Min;Jang, Eun-Su;Joo, Dong-Myoung;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.199-207
    • /
    • 2018
  • In this paper, an all-metal domestic induction heating (IH) system that can quickly identify ferromagnetic and non-ferromagnetic pots considering temperature changes in the working coil is designed. Load modeling is performed after analyzing the parameters of the pot material and the central misalignment of the working coil. To improve the performance and stability of the all-metal IH cooking heater, a power curve-fitting model is used to design a control system that quickly responds to load parameter fluctuations. In addition, a power control algorithm is established to compensate for the reference value by reflecting the increase in working coil temperature during heating of the non-ferromagnetic pot. The validity of the proposed control algorithm for the all-metal IH is verified by experiments using a 3.2 kW all-metal IH cooking heater.

Treatment of Chronic Cough in an Upper Airway Cough Syndrome (UACS)-Suspected Patient with Local Acupuncture Points Stimulation and Application of Topical Herbal Mixed Heating Cream : A Case Report (상기도기침증후군으로 의심되는 만성기침 환자에 대한 인후부 근위취혈 침치료 및 한약 온열크림 도포 경과 : 증례보고)

  • Kim, Eunmi;Jo, Hee-geun
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.557-565
    • /
    • 2019
  • Objectives: This study investigated the effect of local acupuncture point stimulation and the application of a topical herbal mixed heating cream in a chronic cough patient who had not responded to various medications for more than a few months. Methods: An 81 year-old female patient who was suspected to be suffered from Upper Airway Cough Syndrome (UACS) was examined. The patient was treated with local acupuncture point stimulation and the application of a topical herbal mixed heating cream. We used the Leicester Cough Questionnaire, Cough-Specific Quality-of-Life Questionnaire, and Verbal Numerical Rating Scale to assess the patient's respiratory symptoms. Results: Local acupuncture point stimulation and the application of a topical herbal mixed heating cream resulted in the improvement of cough symptoms. The quality of life due to the alleviation of symptoms also significantly improved. Adverse effects were not observed. Conclusions: This study suggests that local acupuncture point stimulation and the application of a topical herbal mixed heating cream may be an effective therapy for the treatment of chronic cough in patients with UACS.

"Dust, Ice, and Gas In Time" (DIGIT) Herschel observations of GSS30-IRS1

  • Je, Hyerin;Lee, Jeong-Eun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.66.2-66.2
    • /
    • 2013
  • As part of the DIGIT key program, we observed GSS30-IRS1, a Class I object located in Ophiuchus (d=125 pc), with Herschel-PACS. More than 70 lines were detected in 50-200 micron band including CO, OH, H2O, and [OI]. All lines, except for [OI], were detected only at the central spaxel of $9.4^{{\prime}{\prime}}{\times}9.4^{{\prime}{\prime}}$ while the [OI] emission is extended along the NE-SW direction. One interesting feature in GSS30-IRS1 is that the continuum is extended beyond PSF, unlike line emission. It suggests that the external heating is important in GSS30-IRS1. For detail analysis of line fluxes, we apply the non-LTE LVG model, RADEX as well as simple rotational diagrams. We also use the Monte Carlo radiative transfer package, RADMC-3D to understand the heating mechanism of dust grains around GSS30-IRS1. We will discuss about heating and cooling processes associated with GSS30-IRS1.

  • PDF

A Continuous Sequential Decision Process Model for R&D Economic Feasibility Assessment of the GDHS in Chejoo Island and Its Application (제주도 GDHS의 R&D투자 타당성 분석을 위한 연속적 SDP모형의 개발 및 응용사례연구)

  • Yang, Moon-Hee;Chang, Kyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.24 no.1
    • /
    • pp.115-126
    • /
    • 1998
  • A GDHS(Geothermal District Heating System) is a heating system supplying a group of districts with heat extracted from geothermal sources. Due to various advantages of GDHS including the saving of fuel consumption as well as the reduction of air pollution, a world-wide trend is to replace central/individual heating systems with GDH systems. The basic point of this paper is that a crash program mentality leads to inappropriate decisions about policy issues in large-scale research and development like the development of GDHS, R&D funding should be viewed as a sequential decision, not a once-and-for-all choice. Hence we develop on economic feasibility assessment model based on a continuous sequential decision process for the Chejoo Island GDHS Project by modifying Roberts's model.

  • PDF

A Case Study for the Economic Feasibility Model and Analysis of a GDHS Given Geothermal Temperature (기대지열온도하에서 GDHS의 경제성분석 사례연구)

  • Yang, Moon-Hee;Kim, Tai-Yoo;Lee, Sang-Kyu
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.23 no.1
    • /
    • pp.115-127
    • /
    • 1997
  • A GDHS(Geothermal District Heating System) is a heating system supplying a group of districts with heat extracted from geothermal sources. The advantages of GDHS include saving fuel consumption as well as reducing air pollution. This paper presents a case study for the economic feasibility model and analysis of a GDHS with which central/individual heating systems are replaced. Configuring to a simplified GDHS which consisits of subsurface systems, surface systems, and transmission/distribution systems, we find out the properties of the system and the model parameters affecting the initial investment/operating costs in order to develop a classical economic feasibility model given geothermal temperature. Based on our model parameter space, we analyzed the geothermal development project of the Jejoo Island probabilistically given prior information such as the expected geothermal power, the demand size and the length of transmission/distribution pipes.

  • PDF

The Comparison of Maintenance Cost and Residents′Consciousness of Remodeling by Rental Apartment Types (임대아파트 유형별 유지관리비와 거주자의 리모델링 의식비교)

  • 박민용;장승재
    • Journal of the Korean housing association
    • /
    • v.14 no.4
    • /
    • pp.69-76
    • /
    • 2003
  • Considering the present development situation of rental apartment since 1982, the supply of rental housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the device of remodeling for low-income dwellers in deteriorated apartment, this study investigated the characteristics of maintenance cost and the residents'consciousness of remodeling by rental apartment types. The results of this study were as follows; The annual maintenance cost of permanent rental apartment was 14,249 won/$\textrm{m}^2$$.$yr, that of fifty years period rental apartment was 13,372 won/$\textrm{m}^2$$.$yr. In the case of remodeling in deteriorated heating system, the principal decision factor of choice was showed “economics” as priority. Residents in rental apartment preferred remodeling to reconstruction, and unit heating system to central heating system.