• Title/Summary/Keyword: central heating

Search Result 205, Processing Time 0.024 seconds

Soil and Coal Radioactivity around Zuunmod Town of Mongolia

  • Erkhembayar, Ts.;Norov, N.;Khuukhenkhuu, G.;Oyunchimeg, Ts.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.501-505
    • /
    • 2002
  • The specific radioactivity concentrations of $\^$238/U, $\^$232/Th, $\^$40/K were measured in soil samples around Zuunmod town of Mongolia using HP-Ge gamma-spectrometer. Also the specific radioactivity concentrations of above elements were measured in coal and ash samples which were collected from the Central steam heating in Zuunmod town. It was determined the effective equivalent dose.

  • PDF

The Study of Synthesis and Reactivity of Metal Complexes With Amino Acidic Ligands(I) (아미노산을 리간드로 갖는 금속착화합물의 합성 및 반응성에 관한 연구(I))

  • Han, Je-Hong;Chung, Pyung-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.75-87
    • /
    • 1994
  • The metal complexes containing amino acidic ligands were prepared by using 11 kinds of amino acids as ligands and Ni, Cu, Co, Zn, Fe as a central metal. The starting was continued for 4hrs at room temperature. But Bis(D,L-Serine)Ni (II), and (D,L-Serine)Co (II) were prepared by heating method($80^{\circ}C$). In order to investigated reaction activity of Bis(D,L-Aspartato) Metal(II), stirring time was varied and Bis(D,L-Tyrosine ) Metal(II) used different divalent metal salts. We anticipate getting a great value from these prepared complexes as a monomer and a catalyst of polymerization which has peculier characteristics.

Korean Household’s Level and Standard of Consumption: For Developing Sustainable Lifestyle (한국가계의 소비수준 및 표준:지속가능한 생활양식의 실현 모색)

  • 손상희
    • Journal of Families and Better Life
    • /
    • v.19 no.5
    • /
    • pp.259-277
    • /
    • 2001
  • The purpose of this study was to identify household’s level and standard of consumption and their related variables in order to derive some useful implications for developing sustainable lifestyle. Data were collected from 567 household wives living in Seoul and the five Metropolitan cities in Korea. The results showed that most households owned such goods as central heating system, shower and bath, refrigerator, microwave oven, vacuum cleaner, washer. TV video player, personal computer, mobile phone, and car. They thought that most of the goods were necessary for the desired level of living and has a strong aspiration to buy those goods. This implied a tendency of uniformity in need perceptions and consumption patterns among Korean households. However, level and standard of consumption measured in selected living area differed according to age. education family size, household income, occupation, and the size housing, which showed that different approach was needed for developing sustainable lifestyle according to these variables.

  • PDF

Ventilation and energy performance evaluation of the office building with variable air volume system (변풍량시스템이 적용된 사무소건물의 환기 및 에너지성능평가)

  • Kwon, Y.L.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.100-108
    • /
    • 1999
  • Variable air volume(VAV) system designed for improving interior environmental control has steadily evolved over the last 20 years. Major advantage of VAV system is that VAV technology allows a single system to provide simultaneous heating and cooling without a seasonal changeover. Research is carried out in order to study the influence on the energy consumption and ventilation performance of two kinds of office building with a mixing ventilation system. Data required for performance evaluation in these building is obtained from the central monitoring station and by measurement.

  • PDF

The Energy Consumption Characteristics of Building Accordance with Air-Conditioning and Heating System (건축물 냉.난방 시스템에 따른 에너지 소비 특성 -서울 소재 A 대학교 건축물을 중심으로-)

  • Park, Kang-Hyun;Cha, Jung-Hoon;Kim, Su-Min
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.333-337
    • /
    • 2011
  • Central control air-conditioning systems are being replaced with individually controlled air-conditioning system in the university. The amount of growth of electricity consumption is due to the increasing demand of electric heat pump. In winter and summer, the energy consumption showed a tendency to increase. On the other hand, showed less energy in spring and autumn. Increase the amount of electricity than the degree of decline in gas consumption was higher. Can be considered as transitional phenomena. Because electric heat pump, gas driven heat pump and the absorption chiller-heater are used at the same time in some of the buildings.

  • PDF

High-Resolution Simulations of the Nuclear Star-Forming Ring

  • Kim, Sungsoo S.;Saitoh, Takayuki R.;Baba, Junichi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.47.2-47.2
    • /
    • 2013
  • We have performed a set of high-resolution simulations of nuclear star-forming ring that results in an inward gas migration from the galactic disk. Our simulations consider gas heating/cooling, star formation, and supernova feedback. The galactic potential was obtained from a snapshot of a 6.3 million particle simulation of a galactic disk at 1 Gyr, which manifests spiral arms and pseudo-bulge. The potential was modeled with a combination of 3-dimensional spherical (for the pseudo-bulge) and 2-dimensional cylindrical (for the disk) multipole expansion technique. With such a potential model, one can easily set up various realistic 3-dimensional potential models by slightly changing the expansion coefficients. We have performed a set of simulations with a few million gas particles covering the central ~6 kpc of the disk for different pseudo-bulge sizes and non-axisymmetry, and we report the dependence of the gas inflow rate, size of the star-forming ring, and star-formation rate in the ring on the size and strength of the non-axisymmetry in the bulge.

  • PDF

On the Study of Intraseasonal and Interannual Oscillations Simulation by using Coupled Model (접합모형을 이용한 경년 및 계절안 진동 모사실험 연구)

  • Ahn Joong-Bae
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.645-652
    • /
    • 1999
  • In order to simulate and investigate the major characteristics of El Nino/Southern Oscillation(ENSO) and Madden Jullian Oscillation(MJO), an intermediate type atmosphere-ocean coupled model is developed and their results are examined. The atmosphere model is a time-dependent non-linear perturbation moist model which can determine the internal heating for itself. The counterpart of the atmosphere model is GCM-type tropical ocean model which has fine horizontal and vertical grid resolutions. In the coupled experiment, warm SST anomaly and increased precipitation and eastward wind and current anomalies associated with ENSO and MJO are properly simulated in Pacific and Indian Oceans. In spite of some discrepancies in simulation MJO, the observed atmospheric and oceanic low-frequency characteristics in the tropics are successfully identified. Among them, positive SST anomalies centered at the 100m-depth of tropical eastern-central Pacific due to the eastward advection of warm water and reduced equatorial upwelling, and negative anomalies in the Indian and western Pacific seem to be the fundamental features of tropical low-frequency oscillations.

  • PDF

A study on the Shrinkage Properties of precast concrete using Calcium hardening accelerator (칼슘계 경화촉진제를 사용한 프리캐스트 콘크리트의 수축특성에 관한 연구)

  • Min, Tae-Beom;Jo, In-Seong;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.44-45
    • /
    • 2014
  • On this study, initial crack index was evaluated by performing FEM analysis to crack propagation from hydration heat for development of precast concrete. On the result, as increased the usage of hardening accelerator, initial compressive strength were improved and setting time also was shortened. Additionally, central temperature of concrete was increased, the reaching time for the highest temperature could be shortened. By the result to assess crack index, there was no problem about crack despite of growth of initial high hydration heating. This result guessed because of small size element when analyzed trough FEM, realization for mass concrete's crack index should be performed.

  • PDF

공조 시스템용 DDC의 온라인 최적제어에 관한 연구

  • 안병천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1072-1078
    • /
    • 2001
  • The real time optimal control algorithm of the DDC controller for chilled water and supply air temperature set-point of heating, ventilating, air-conditioning and refrigeration systems has been researched for minimization of the total power which is consumed by the chiller, chilled water pump and air handing unit fan. The study has been done by using TRNSYS program in order to analyze the central cooling system in terms of the environmental variables such as indoor cooling lead and wet-bulb temperature. This optimal control alogorithm saves more energy and is suitable for real time on-line control in comparison with conventional method.

  • PDF

A case of myelopathy after electrical injury (전기 손상에 의한 척수병증 1례)

  • Min, Joo-Hong;Ko, Sang-Bae;Sung, Jung-Joon;Kwon, Ohyun;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.5 no.2
    • /
    • pp.214-216
    • /
    • 2003
  • High voltage electrical injury can cause considerable damage to the nervous system including spinal cord, but, the pathophysiology of myelopathy remains to be studied. A 44-year old man with paraparesis after electrical injury was diagnosed as electrical injury induced- myelopathy by normal spine MRI and somatosensory evoked potential showing central conduction abnormality. It implicates that the presumed mechanism of the myelopathy prefers the electroporation or electroconformational protein denaturation to the joule heating.

  • PDF