• 제목/요약/키워드: center symmetry

검색결과 255건 처리시간 0.025초

완고한 보행장애를 주소로 하는 만성기 뇌출혈 환자의 한의 치료 및 재활 운동 증례보고 1례 : GAITRite®를 이용하여 (A Case Report of a Chronic Intracerebral Hemorrhage Patient with Obstinate Gait Disturbance Treated with Korean Medicine and Rehabilitation Exercise)

  • 채인철;최인우;김찬영;박미소;박상수;정은선;차지윤;조현경;김윤식;설인찬;유호룡
    • 대한한방내과학회지
    • /
    • 제40권4호
    • /
    • pp.730-741
    • /
    • 2019
  • Objective: The aim of this study was to report the effectiveness of traditional Korean medicine treatment with rehabilitation exercise on a chronic intracerebral hemorrhage patient with a severe gait disturbance. Method: The patient was treated with Korean herbal medicine (Gami-sibjeondaebo-tang) along with acupuncture, moxibustion, and rehabilitation exercise. The treatment effect was evaluated through the Manual Muscle Test (MMT) and the Korean version of the Modified Barthel Index (K-MBI). The gait of the patient was evaluated by Functional Ambulatory Category (FAC) and the Timed Up and Go (TUG) test. The spatiotemporal parameters were evaluated by a walkway system (GAITRite(R) system) and gait symmetry was evaluated by Symmetry Criterion (SC). Results: After 111 days of traditional Korean medicine treatment, the spatiotemporal parameters and symmetry of the patient's gait improved. Conclusion: This study suggested that traditional Korean medicine treatment with rehabilitation exercise could be effective for gait disturbance in patients with chronic intracerebral hemorrhage.

Anodic Performances of Surface-Treated Natural Graphite for Lithium Ion Capacitors

  • Park, Chul Min;Jo, Yong Nam;Park, Jung Woo;Yu, Ji-Sang;Kim, Jeom-Soo;Choi, Jungkyu;Kim, Young-Jun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권9호
    • /
    • pp.2630-2634
    • /
    • 2014
  • The surface of natural graphite was modified by the use of hydrogen peroxide and evaluated as an anode material for lithium ion capacitors (LICs). The surface treatment was carried out under various ultrasonic conditions of 200, 300, and 400W, which were applied to a mixture of natural graphite and hydrogen peroxide solution for 1 h. While the bulk structure was maintained, the hexagonal symmetry and physical properties of natural graphite, such as BET surface area, tap density, and particle size, were affected by the surface treatment. FT-IR and XPS measurements confirmed the signature of C=O on the surface of graphite samples after treatment. Both the pristine and surface-treated graphites showed a similar reversible capacity of $370mAhg^{-1}$, and the coulombic efficiency of surface-treated graphite decreased with higher ultrasonic energies (89.1%, 89.0%, and 88.0% for 200, 300, and 400 W) comparing with pristine graphite (89.4%). The capacity retention of LICs was greatly improved with the treated natural graphite. The graphite treated under the ultrasonic energy of 300 W and pristine natural graphite showed capacity retention of 77.5% and 42.9%, implying that the surface treatment was an effective method for the improvement of natural graphite as an anode material for LICs.

연성기판위에 제작된 고효율 Red 인광 OLED의 특성평가 (Characterization of High Efficient Red Phosphorescent OLEDs Fabricated on Flexible Substrates)

  • 김성현;이유진;변기남;정상윤;이범성;유한성
    • 반도체디스플레이기술학회지
    • /
    • 제4권2호
    • /
    • pp.15-19
    • /
    • 2005
  • The organic light-emitting devices(OLEDs) based on fluorescence have low efficiency due to the requirement of spin-symmetry conservation. By using the phosphorescent material, the internal quantum efficiency can reach 100$\%$, compared to 25$\%$ in case of the fluorescent material [1]. Thus recently phosphorescent OLEDs have been extensively studied and showed higher internal quantum efficiency than conventional OLEDs. In this study, we have applied a new Ir complex as a red dopant and fabricated a red phosphorescent OLED on a flexible PC(Polycarbonate) substrate. Also, we have investigated the electrical and optical properties of the devices with a structure of A1/LiF/Alq3/(RD05 doped)BAlq/NPB/2-TNAIA/ITO/PC substrate. Our device showed the lightening efficiency of > 30 cd/A at an initial brightness of 1000 cd/$m^{2}$. The CIE(Commission Internationale de L'Eclairage) coordinates for the device were (0.62,0.37) at a current density of 1 mA/$cm^{2}$. In addition, although the sheet resistance of ITO films on PC substrate is higher than that on glass substrate, the flexible OLED showed much better lightening efficiency without much increase in operating voltage.

  • PDF

Evaluation of Therapeutic Efficacy using [18F]FP-CIT in 6-OHDA-induced Parkinson's Animal Model

  • Jang Woo Park;Yi Seul Choi;Dong Hyun Kim;Eun Sang Lee;Chan Woo Park;Hye Kyung Chung;Ran Ji Yoo
    • 대한방사성의약품학회지
    • /
    • 제9권1호
    • /
    • pp.3-8
    • /
    • 2023
  • Parkinson's disease is a neurodegenerative disease caused by damage to brain neurons related to dopamine. Non-clinical animal models mainly used in Parkinson's disease research include drug-induced models of 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine and 6-hydroxydopamine, and genetically modified transgenic animal models. Parkinson's diagnosis can be made using brain imaging of the substantia nigra-striatal dopamine system and using a radiotracer that specifically binds to the dopamine transporter. In this study, 18F-N-(3-fluoropropyl)-2β-carboxymethoxy-3β-(4-iodophenyl) nortropane was used to confirm the image evaluation cutoff between normal and parkinson's disease models, and to confirm model persistence over time. In addition, the efficacy of single or combined administration of clinically used therapeutic drugs in parkinson's animal models was evaluated. Image analysis was performed using the PMOD software. Converted to standardized uptake value, and analyzed by standardized uptake value ratio by dividing the average value of left striatum by the average value of right striatum obtained by applying positron emission tomography images to the atlas magnetic resonance template. The image cutoff of the normal and the parkinson's disease model was calculated as SUVR=0.829, and it was confirmed that it was maintained during the test period. In the three-drug combination administration group, the right and left striatum showed a high symmetry of more than 0.942 on average and recovered significantly. Images using 18F-N-(3-fluoropropyl)-2β-carboxymethoxy-3β-(4-iodophenyl) nortropane are thought to be able to diagnose and evaluate treatment efficacy of non-clinical Parkinson's disease.

인하도선 주변에서 발생하는 자장의 억제 (The Control of the Magnetic Field around Down Conductors)

  • 이복회;강성만;이승칠;엄주흥;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.216-218
    • /
    • 2001
  • This paper deals with the control of magnetic field around the down conductor of lightning protection systems. The magnetic field strength in the vicinity of down conductor is shown to drop off rapidly with distance from the down conductor and is reversely proportional to the number of down conductor. Also the magnetic field strength is decreased in the structures as the down conductor is installed with the symmetrical arrangement, and it is zero at the center of symmetry. The magnetic field strengths for the symmetrical arrangement of two down conductors are less than one half compared with that for a down conductor. A proper arrangement of down conductor can reduce or cancel the magnetic field in a restricted place where information-oriented and computerized facilities are densely installed.

  • PDF

Crystallographic Orientation Dependence of Sputtering Rate in Sendust Targets

  • Kim, Myong-Ryeong;Hum Seo
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 춘계학술대회 논문집
    • /
    • pp.167-171
    • /
    • 1995
  • The orientation dependence of sputtering rate in the sendust polysrystalline targets was studied, It was fount from the present work that the erosion process is not uniform from one grain to another even within a target because of its polysrystalline nature showing many different orientation of grains. The grains oriented to promote efficient erosion were characterized by the close-packed planes which have large interplanar spacing and strong binding energy, The characteristic line patterns appeared on as-sputter target surface are discussed in terms of symmetry of crystllographic planes.

  • PDF

ROBUST $L_{p}$-NORM ESTIMATORS OF MULTIVARIATE LOCATION IN MODELS WITH A BOUNDED VARIANCE

  • Georgly L. Shevlyakov;Lee, Jae-Won
    • 한국수학교육학회지시리즈B:순수및응용수학
    • /
    • 제9권1호
    • /
    • pp.81-90
    • /
    • 2002
  • The least informative (favorable) distributions, minimizing Fisher information for a multivariate location parameter, are derived in the parametric class of the exponential-power spherically symmetric distributions under the following characterizing restrictions; (i) a bounded variance, (ii) a bounded value of a density at the center of symmetry, and (iii) the intersection of these restrictions. In the first two cases, (i) and (ii) respectively, the least informative distributions are the Gaussian and Laplace, respectively. In the latter case (iii) the optimal solution has three branches, with relatively small variances it is the Gaussian, them with intermediate variances. The corresponding robust minimax M-estimators of location are given by the $L_2$-norm, the $L_1$-norm and the $L_{p}$ -norm methods. The properties of the proposed estimators and their adaptive versions ar studied in asymptotics and on finite samples by Monte Carlo.

  • PDF

Comparison of interpretation methods for large amplitude oscillatory shear response

  • Kim Hyung-Sup;Hyun Kyu;Kim Dae-Jin;Cho Kwang-Soo
    • Korea-Australia Rheology Journal
    • /
    • 제18권2호
    • /
    • pp.91-98
    • /
    • 2006
  • We compare FT (Fourier Transform) and SD (Stress Decomposition), the interpretation methods for LAOS (Large Amplitude Oscillatory Shear). Although the two methods are equivalent in mathematics. they are significantly different in numerical procedures. Precision of FT greatly depends on sampling rate and length of data because FT of experimental data is the discrete version of Fourier integral theorem. FT inevitably involves unnecessary frequencies which must not appear in LAOS. On the other hand, SD is free from the problems from which FT suffers, because SD involves only odd harmonics of primary frequency. SD is based on two axioms on shear stress: [1] shear stress is a sufficiently smooth function of strain and its time derivatives; [2] shear stress satisfies macroscopic time-reversal symmetry. In this paper, we compared numerical aspects of the two interpretation methods for LAOS.

혈류역학을 이용한 촌구와 인영의 특성비교 (Comparative study of pulse point using hemodynamics)

  • 신상훈;박대훈;박영재;박영배
    • Journal of Acupuncture Research
    • /
    • 제21권5호
    • /
    • pp.241-248
    • /
    • 2004
  • Objectives : The purpose of this study is to examine the hemodynamic characteristics of pulse point. Methods : The computational analysis algorithms of arterial tree system was derived. In order to investigate the effect of internal organ on the pulse point, the diameter of celiac artery was reduced by half. Results : The sensitivity of flow change at the Inyoung(Renying) is better than that of the Chongu(Cunkou). but the Inyoung was worse than the Chongu in the point of the left and right symmetry. The pressure changes at the Inyoung and the Chongu were in the similar range. Conclusions : It was found from the result that the Chongu shows the more symmetrical hemodynamic characteristics than the Inyoung.

  • PDF

Design and Multiplier-Free Realization of FIR Nyquist Filters with Coefficients Taking Only Discrete Values

  • Boonyanant, Phakphoom;Tantaratana, Sawasd
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.852-855
    • /
    • 2002
  • This paper presents a design of FIR near-equiripple Nyquist filters having zero-intersymbol interference (ISI) and low sensitivity to timing jitter, with coefficients taking only discrete values. Using an affine scaling linear programming algorithm, an optimum discrete coefficient set can be obtained in a feasible computational time. Also presented is a pipelined multiplier-free FIR filter realization with periodically time-varying (PTV) coefficients based on a hybrid form suitable for Nyquist filter. The realization exploits the coefficient symmetry to reduce the hardware by about one half. High speed computation and low power consumption are achieved by its pipelined and low fan-out structure.

  • PDF