• Title/Summary/Keyword: center frequency

Search Result 6,240, Processing Time 0.034 seconds

Stepwise Inertial Control of a Doubly-Fed Induction Generator to Prevent a Second Frequency Dip

  • Kang, Mose;Lee, Jinsik;Hur, Kyeon;Park, Sang Ho;Choy, Youngdo;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2221-2227
    • /
    • 2015
  • To arrest a frequency nadir, a stepwise inertial control (SIC) scheme generates a constant active power reference signal of a wind turbine generator (WTG) immediately after a disturbance and maintains it for the predetermined time. From that point, however, the reference of a WTG abruptly decreases to restore the rotor speed for the predefined period. The abrupt decrease of WTG output power will inevitably cause a second frequency dip. In this paper, we propose a modified SIC scheme of a doubly-fed induction generator (DFIG) that can prevent a second frequency dip. A reference value of the modified SIC scheme consists of a reference for the maximum power point tracking control and a constant value. The former is set to be proportional to the cube of the rotor speed; the latter is determined so that the rotor speed does not reach the minimum operating limit by considering the mechanical power curve of a DFIG. The performance of the modified SIC was investigated for a 100 MW aggregated DFIG-based wind power plant under various wind conditions using an EMTP-RV simulator. The results show that the proposed SIC scheme significantly increases the frequency nadir without causing a second frequency dip.

Estimation of System Damping Parameter Using Wavelet Transform (웨이블릿 변환에 의한 시스템 감쇠변수 평가)

  • Lee, Seok-Min;Jung, Beom-Seok;Hong, Seok-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.30-37
    • /
    • 2015
  • The estimation of system damping parameter of the response signal with lower natural frequency and higher damping parameter from free vibration is affected by the wavelet center frequency. This study discusses these considerations in the context of the wavelet's multi-resolution character and includes guidelines for selection of wavelet center frequency. The experiment with H-Beam and numerical examples with respect to three cases (i)single mode, (ii)separated modes and (iii)close modes demonstrate the validity of method to improve the accuracy of the estimated damping parameter. The localization of the corresponding scale for the total scales is determined by the natural frequency of the analysing mode and is affected by the wavelet center frequency. Thus, the reliability for the accuracy of the estimated damping parameter can be improved by the corresponding scale of the natural frequency for the analysing mode is localized at the half of the total scales.

Effect of Transcutaneous High Frequency Wave on the Change of Tissue Temperature and Histology in Sprague-Dawley Rat (백서에서 경피적 고주파 자극에 따른 온도 변화 및 조직 변화)

  • Kim, Kyung Ah;Moon, Chang Won;Song, Da-Hyun;Kim, Sang Jun
    • Clinical Pain
    • /
    • v.15 no.2
    • /
    • pp.92-96
    • /
    • 2016
  • Objective: High frequency wave has been used in cancer treatment and cosmetic area but not in musculoskeletal pain yet. The purpose of this study is to evaluate temperature distribution according to depth and confirm safety of high frequency wave through animal study. Method: High frequency wave was applied to the posterior limb of 9 Sprague-Dawley rats for 20 minutes (experimental group) and no wave was used in the same number of rats for control group. Tissue temperature was measured from skin surface to 1 cm depth (surface, 1 mm, 5 mm, and 1 cm) for 5 seconds. Results: In the experimental group, temperature was elevated 3.2℃ at skin surface, 2.87℃ at 1 mm, 2.25℃ in 5 mm, and 1.74℃ in 1 cm depth. These were significantly different from those in the control group (p<0.001). There was no bulla or redness in the skin after high frequency wave stimulation and neither change of myocytes nor collagen degeneration was found in the tissue histology. There was no apoptosis in the skin surface and muscle layer in TUNEL assay. Conclusion: High frequency wave elevated tissue temperature from the skin to muscle layer without both histologic change and apoptosis.

A frequency measurement based on modified zero-crossing method for anti-islanding detection of distributed generation (분산전원의 Anti-islanding용 수정된 zero-crossing 방식 주파수 검출기법)

  • Bae, Byung-Yeol;Baek, Seung-Taek;Lee, Jin-Hee;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.634-636
    • /
    • 2008
  • This paper proposes a frequency detection method based on an advanced zero-crossing technique. Zero-crossing method for detecting frequency is one of the most widely used methods today. Although it is simple to apply, it requires extra hardware in implementation due to its limitations in accuracy. The proposed method models the error generated during zero crossing linearization and compensated for it in real time which makes it simple and accurate. The validity of the method and its applicability in anti-islanding detection of distributed generators was confirmed through simulation.

  • PDF

A Study on Spectral Characteristics of Ultrasonic Signal for Tissue Attennation Coefficient Measurement (생체내의 초음파 감쇄계수를 측정하기 위한 초음파 신호스펙트럼 특성에 관한 연구)

  • Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.29-36
    • /
    • 1983
  • In this paper, center frequency down slift of ultrasonic echo signals which for the measurements of frequency dependent attenuation in the biological tissue are estimated. Center frequency down shift of echo-signals are estimated after signal spectrum analysis of whole echo-signals. In case of signal spectrums are simple, estimation of down shift frequency is very simple and in case of complicate spectrum, estimation of down shift frequency is depend on spectral shape. In case of unable to estimate, frequency dependence of medium is nonlinear(n) 1), in which upper shift of spectrums are presented. In case of unable to estimate, spectrum analysis are performed at local position. At consquence, we know that spectral dispersions are caused complicately by biological tissue layer.

  • PDF

Microwave Photonics Frequency-Converted Link Using Electroabsorption Devices

  • Wu, Y.;Shin, D.S.;Chang, W.S.C.;Yu, P.K.L.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.1
    • /
    • pp.74-81
    • /
    • 2004
  • We propose a novel scheme to transmit high center frequency RF signals using electroabsorption devices (EADs) as frequency converters at the transmitter and the receiver. In this approach frequency heterodyning is employed for obtaining high center frequency. With the EAD as a detector/mixer at the receiver we demonstrated a smaller conversion loss than that of the conventional modulator/mixer. With EAD as a modulator/mixer at the transmitter and with two heterodyned lasers to generate an optical local oscillator (LO), we demonstrated a large reduction (${\sim}23dB$) in conversion loss, and the transmission is not limited by the optical saturation of the EAD. This transmission scheme has optical single-side-band transmission feature which greatly relieves the fiber dispersion effect.

Frequency Assignment Method using NFD and Graph Coloring for Backbone Wireless Links of Tactical Communications Network (통합 필터 변별도와 그래프 컬러링을 이용한 전술통신망 백본 무선 링크의 주파수 지정 방법)

  • Ham, Jae-Hyun;Park, Hwi-Sung;Lee, Eun-Hyoung;Choi, Jeung-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.441-450
    • /
    • 2015
  • The tactical communications network has to be deployed rapidly at military operation area and support the communications between the military command systems and the weapon systems. For that, the frequency assignment is required for backbone wireless links of tactical communications network without frequency interferences. In this paper, we propose a frequency assignment method using net filter discrimination (NFD) and graph coloring to avoid frequency interferences. The proposed method presents frequency assignment problem of tactical communications network as vertex graph coloring problem of a weighted graph. And it makes frequency assignment sequences and assigns center frequencies to communication links according to the priority of communication links and graph coloring. The evaluation shows that this method can assign center frequencies to backbone communication links without frequency interferences. It also shows that the method can improve the frequency utilization in comparison with HTZ-warfare that is currently used by Korean Army.

The First Multi-Frequency Synthesis Space-VLBI Observations of 0059+581 with Radioastron

  • Alexey Rudnitskiy;Mikhail Shchurov;Taehyun Jung;Marcello Giroletti
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.1
    • /
    • pp.91-96
    • /
    • 2023
  • In this paper, we describe the first multi-frequency synthesis observations of blazar 0059+581 made with the Radioastron space-ground interferometer in conjunction with the Korean VLBI Network (KVN), Medicina and Torun ground telescopes. We conducted these observations to assess the spaceground interferometer multi-frequency mode capability for the first time.

High Conversion Gain and Isolation Characteristic V-band Quadruple Sub-harmonic Mixer (고 변환이득 및 격리 특성의 V-band용 4체배 Sub-harmonic Mixer)

  • Uhm, Won-Young;Sul, Woo-Suk;Han, Hyo-Jong;Kim, Sung-Chan;Lee, Han-Shin;An, Dan;Kim, Sam-Dong;Park, Hyung-Moo;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.7
    • /
    • pp.293-299
    • /
    • 2003
  • In this paper, we have proposed a high conversion and isolation characteristic V-band quadruple sub-harmonic mixer monolithic circuit which is designed and fabricated for the millimeter wave down converter applications. While most of the sub-harmonic mixers use a half of fundamental frequency, we adopt a quarter of the fundamental frequency. The proposed circuit is based on a sub-harmonic mixer with APDP(anti-parallel diode pair) and the 0.1 ${\mu}{\textrm}{m}$ PHEMT's (pseudomorphic high electron mobility transistors). Lumped elements at IF port provide better selectivity of IF frequency and increase isolation. Maximum conversion gain of 0.8 ㏈ at a LO frequency of 14.5㎓ and at a RF frequency of 60.4 ㎓ is measured. Both LO-to-RF and LO-to-IF isolations are higher than 50 ㏈. The conversion gain and isolation characteristic are the best performances among the reported quadruple sub-harmonic mixer operating in the V-band millimeter wave frequency thus far.