• Title/Summary/Keyword: ceiling system

Search Result 352, Processing Time 0.025 seconds

A Study on the Performance Experiments of Lightweight Wall of Long-life Housing by Ceiling Infill System (천장 인필시스템에 따른 장수명주택 경량벽체의 성능실험에 관한 연구)

  • Seo, Dong-Goo;Lee, Jong-Ho;Kim, Eun-Young;Hwang, Eun-Kyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.247-248
    • /
    • 2018
  • In order to secure the variability of long-life housing, dry walls are used. The composite gypsum board panel is the most frequently used infill system for the wall, and it is an excellent construction method in terms of constructability and economic feasibility. However, there are also problems such as the destruction of Ondol pipes at the bottom floor and being unable to fix the light weight steel frame (M-bar) when a variable composite gypsum board panel is used. To solve such problems, a wall with a method of fixing only the top part without fixing the bottom floor is developed, but it is difficult to identify the durability of ceiling frame according to the tensile force of stud and the safety according to the Stiffness and impact resistance (soft body) of ceiling frame. Therefore, this study verified the effectiveness of infill system for the wall by conducting experiment on the stiffness and impact resistance of composite gypsum board panel according to the reinforcement of ceiling frame (wooden frame, double saw-toothed bracket, Cross M-bar). As a result, it was possible to secure the safety of wooden frame while the impact resistance and the Stiffness of double saw-toothed bracket and cross M-bar were not secured.

  • PDF

Has the Copayment Ceiling Improved Financial Protection in the Korean National Health Insurance System? Evidence From the 2009 Policy Change

  • Lee, Tae-Jin;Cheong, Chelim
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.6
    • /
    • pp.393-400
    • /
    • 2017
  • Objectives: To relieve the financial burden faced by households, the Korean National Health Insurance (NHI) system introduced a "copayment ceiling," which evolved into a differential ceiling in 2009, with the copayment ceiling depending on patients' income. This study aimed to examine the effect of the differential copayment ceiling on financial protection and healthcare utilization, particularly focusing on whether its effects varied across different income groups. Methods: This study obtained data from the Korea Health Panel. The number of households included in the analysis was 6555 in 2008, 5859 in 2009, 5539 in 2010, and 5372 in 2011. To assess the effects of the differential copayment ceiling on utilization, out-of-pocket (OOP) payments, and catastrophic payments, various random-effects models were applied. Utilization was measured as treatment days, while catastrophic payments were defined as OOP payments exceeding 10% of household income. Among the right-hand side variables were the interaction terms of the new policy with income levels, as well as a set of household characteristics. Results: The differential copayment ceiling contributed to increased utilization regardless of income levels both in all patients and in cancer patients. However, the new policy did not seem to reduce significantly the incidence of catastrophic payments among cancer patients, and even increased the incidence among all patients. Conclusions: The limited effect of the differential ceiling can be attributed to a high proportion of direct payments for services not covered by the NHI, as well as the relatively small number of households benefiting from the differential ceilings; these considerations warrant a better policy design.

Investigation on the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (매단 천장의 실간 공기전달음 실험실 측정 방법 고찰)

  • 양관섭;이근희;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1126-1131
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO or ASTM have been used for evaluating sound performance in domestic so far. In this study, every regulation from ISO, ASTM, especially for airborne sound insulation against suspended ceiling system, is analyzed in order to apply to establishment of Korean Standards on test methods and test facility of suspended ceiling system and materials.

  • PDF

A Study on the Operational Ceiling Forecasting and its Improvement Using a Mesoscale Numerical Prediction Model over the Korean Peninsula (중규모 수치예측 모델을 이용한 한반도 시일링 예보 및 현업 운영 개선에 관한 연구)

  • Lee, Seung-Jae;Kim, Young-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.1
    • /
    • pp.24-28
    • /
    • 2011
  • This paper reviews a ceiling prediction method based on a mesoscale meteorological modeling system in South Korea. The study was motivated by the tendency of higher model ceiling height than the observed in daily operational forecasts. The goal of the paper is to report an effort to improve the operational ceiling prediction skill by conducting numerical experiments controlling a model parameter. In a case experiment, increasing constant values used in the relationship between extinction coefficients and concentration showed better performance, indicating a short-term strategy for operational local ceiling forecast improvement.

Experiment Evaluation for the Heavy-weight Impact Sound of Dry Double-floor System - Effect of Rubber Hardness and Ceiling Structure - (건식이중바닥구조의 중량충격음에 대한 실험적 평가 - 지지구조 및 천장구조 구성에 따른 영향 -)

  • Yeon, Junoh;Kim, Kyoungwoo;Choi, Hyunjuong;Yang, Kwanseop;Kim, Kyungho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.34-40
    • /
    • 2013
  • The 1st assessment(performance test) was applied to assure the floor impact sound performance for developing the dry double-floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in sub-structure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5 dB. Based on this result, the 2nd assessment(performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry double-floor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPEII-3 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPEII-3 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

Triaxial Shake Table Test about Seismic Performance of Ceiling System with Gypsum Panels (석고 패널이 부착된 천장 시스템의 내진성능 평가를 위한 3축 진동실험)

  • Park, Hae-Yong;Jeon, Bub-Gyu;Kim, Jae-Bong;Gim, Min-Uk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.143-153
    • /
    • 2019
  • In this study, a full scale 3-axes shake table test for M-bar and T-bar type ceilings commonly used in the country was conducted. Through damage inspection during the test, seismic performance of ceilings according to variables, such as clearance between wall mold and ceiling as well as existence of facilities, was evaluated. A test frame consisted of square hollow section members was used for the shake table test. The experimental method was performed as a fragility test using required response spectrum described in ICC-ES AC156. In the case of architectural nonstructural component that contain ceilings, it mainly is evaluated the performance by post-test visual inspection. For the evaluation of seismic performance of ceilings, this study classified and defined damaged items for targeted ceiling system referring to illustrative damage according to nonstructural performance levels accordance with ASCE 41 and previous studies. And proposed illustrative damage items classification was utilized to compare the degree of the damage according to experimental variables. The experiment results confirmed that differences in boundary conditions due to the clearance at wall mold and the installation of facilities had a significant effect on the seismic performance of the ceiling.

The Evaluation of Ceiling Depth Impact on Lighting and Overall Energy Consumption of a Building with Top-lighting System

  • Amina, Irakoze;Kee, Han Ki;Lee, Young-A
    • Architectural research
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • The purpose of this study was to evaluate the variation in building energy predictions caused by simulation settings related to building envelop thickness. The study assessed the ceiling depth impact on skylight energy performance through OpenStudio integrated Radiance and EnergyPlus simulation programs. A ceiling as deep as 1.5 to 3m was analyzed for skylight to roof ratios from 1% to 25%. The results indicated that the building ceiling depth negatively affected the capability of skylights to significantly reduce building energy consumption. Through a parametric analysis, the study concluded that 8%, 9%, 10% and 11% skylight to roof ratio were optimal in terms of total building energy consumption for a ceiling depth of 1.5m, 2m, 2.5m and 3m, respectively. In addition, the results showed that the usually recommended 5% skylight to roof ratio was only efficient when no ceiling depth was included in the simulation model. Furthermore, the study indicated that the building energy saved by the optimal skylight of each ceiling depth decreased as the ceiling depth deepened. The highest total building energy reduction was 9%, 7%, 5% and 3% for a ceiling depth of 1.5m, 2m, 2.5m and 3m, respectively. This study induced that the solar heat gains and daylight visible transmittance by ceiling depth were crucial in the predictions of skylight energy performance and should not be neglected through building simulation simplifications as it is commonly done in most simulation programs' settings.

A Study on the Evaluation of Heating-Conditioned Environment with the Size of Classroom - Focused on Inlet Temperature of Ceiling Type Air-Conditioning System - (교실 규모에 따른 난방 공조환경 평가에 관한 연구 -천장형 냉난방기의 취출온도를 중심으로 -)

  • 최정민;김용이;박효석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1035-1042
    • /
    • 2003
  • As the desire for a better condition in classroom increases, the distribution rate of warming and cooling conditioners increases. But it is known that according to the way by which the equipments put and are operated the comfortableness felt by persons who are in classroom can make a difference. Therefore, proper equipments in accordance with the size of classroom should be considered as well as operational methods when ceiling warming and cooling conditioners put. This study makes conclusions as follows through a simulation to get improvements in accordance with the size of classroom and to improve the heating performance of ceiling warming and cooling conditioners in classroom.

Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안)

  • Yang, Kwan-seop;Lee, Keun-hee;Kim, Sun-woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.393.1-393
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so far. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

Evaluation for The Heavy-weight Impact Sound Reduction Performance of Dry Double-Floor System (건식 이중바닥구조의 중량충격음 저감성능 평가)

  • Yeon, Junoh;Kim, Kyoungwoo;Choi, Hyunjuong;Yang, Kwanseop;Kim, Kyungho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.280-285
    • /
    • 2012
  • The 1st assessment (performance test) was applied to assure the floor impact sound performance for developing the dry double- floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in substructure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5dB. Based on this result, the 2nd assessment (performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry doublefloor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPE-11 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPE-11 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

  • PDF