• Title/Summary/Keyword: ceiling materials

Search Result 150, Processing Time 0.026 seconds

Evaluation of Air Contaminants Concentrations and Ventilation Systems in Governmental Agency and University Laboratories (국내 정부출연연구기관 및 대학교 실험실 공기 오염물질 농도 및 환기시스템 평가)

  • Ha, Ju-Hyun;Shin, Yong-Chul;Lee, Hyun-Seok;Paik, Samuel Y.;Yi, Gwang-Yong;Lee, Byeong-Ku
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • This study was conducted to compare the concentration of various air contaminants in nine different laboratories during routine activities. Volatile organic compounds (VOC) were sampled and analyzed using NIOSH Method 1500 and asbestos fibers were sampled and analyzed using NIOSH Method 9002 and 7400. Detectable levels of acetone, toluene and ethanol were found in all the laboratories and xylene and n-hexane were detected in eight of the nine laboratories. All the VOC concentrations were well below the Korean Ministry of Labor's Exposure Limit and American Conference of Governmental Industrial Hygienists' (ACGIH) Threshold Limit Values (TLVs). Total VOC concentrations at the university laboratories were significantly higher than those at governmental agency laboratories. Airborne fiber concentrations were below 0.01 fibers/cc, while the concentration of chrysotile was 2% in insulation materials sprayed on the ceiling of one laboratory. While all the governmental agency laboratories (n=4) had fume hoods, two out of the five university laboratories did not have fume hoods. The capture velocity of half of the fume hoods were below the maintenance standard(0.4 m/sec). In conclusion, the study suggests that the current controls in place at both university and government agency laboratories are not sufficient in limiting exposure to harmful chemicals to non-detectable levels, though they appear to be adequate in protecting workers to levels below applicable occupational exposure limits. The study also suggests that researchers working in university laboratories may be exposed to greater levels of contaminant than those working in government agency laboratories.

An Experimental and Numerical Study on Fire Suppression Using a Mid-low Pressure Water Mist in a Carriage Fire (중저압 물분무를 이용한 객차내 화재진압에 관한 실험 및 수치해석적 연구)

  • Roh Jae-Seong;Yang Seung-Shin;Kim Dong-Hyun;Jung Woo-Sung;Jang Yong-Jun;Ryou Hong-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.3 s.34
    • /
    • pp.291-297
    • /
    • 2006
  • The present study investigated the effect of fire suppression using a mid-low pressure water mist in a carriage fire. The fire extinguishing time and temperature distributions below ceiling in the enclosed compartment of $2.9m{\times}2.8m{\times}5.0m$ were measured by stopwatch and k-type thermocouples for various fire positions. The numerical simulations were extensively performed using. Fire Dynamics Simulator(FDS, Ver. 4.0) code and the predictions were compared with experimental data. The prediction results showed good agreement with the measured maximum temperature in the all cases. Whereas the predicted temperature was about $40^{\circ}C$ higher than the measured one after operating of water mist. The predicted fire extinguishing times were compared with those of measured data. Fires are extinguished within 200 seconds at the experiment in Case 2 and Case 3. But in Case 1 fire was not extinguished in the numerical simulation. The reason of the discrepancy between predicted and measured data was that a simple suppression algorithm has been implemented in FDS. Also, various databases of fire properties for combustible materials and more elaborate model considering the water mist were required fur better predictions of the cooling and suffocation effect.

Reliability and Validity of an Iranian Version of the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire for Patients with Multiple Myeloma: the EORTC QLQ-MY20

  • Ahmadzadeh, Ahmad;Yekaninejad, Mir Saeed;Saffari, Mohsen;Pakpour, Amir H;Aaronson, Neil K
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.255-259
    • /
    • 2016
  • Background: Reliable and validated instruments are needed in order to study the quality of life in myeloma patients. This study aimed to translate and explore the psychometric properties of the European Organisation for Research and Treatment of Cancer (EORTC) myeloma module (QLQ-MY20) in Iranian patients. Materials and Methods: Two hundred and fifteen patients with multiple myeloma (MM) were recruited from Imam Khomeini Hospital, Tehran. A standard forward-backward translation procedure was implemented. Participating patients were asked to complete the EORTC QLQ-C30 and the QLQ-MY20 three times, at study entry, after two weeks, and again after three months. Data were tested for the range of measurement, internal consistency, test-retest reliability, known group comparison, responsiveness and factor structure. Results: Mean age of the patients was 60.7 years. No floor and ceiling effects were seen for the QLQ-MY20. Cronbach's ${\alpha}$ was greater than 0.80 for all three multi-item scales (ranging from 0.82 to 0.93). All four scales had test-retest reliability of 0.85 or greater. Results of the confirmatory factor analysis that the hypothesized 3-scale measurement model of the QLQ-MY20. Moreover, the Persian version for the QLQ-MY20 differentiated between subgroups of the patients in terms of beta-2 microglobulin, fracture and performance status. The responsiveness of the QLQ-MY20 to change over time was confirmed within 3 months. Conclusions: the results of our study indicate that our Iranian version of the QLQ-MY20 is a feasible, reliable and valid questionnaire for assessing the condition-specific quality of life of patients with MM.

Experimental Study on the Thermal Properties of Materials for Fire Resistive Ceiling Structure at High Temperature (내화천장구조 재료의 고온 열특성 실험 연구)

  • Yeo, In-Hwan;Cho, Bum-Yean;Min, Byung-Yeol;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.334-339
    • /
    • 2011
  • 이 연구에서는 내화천장구조 재료의 고온 열특성을 파악하여, 건축물 화재시 천장구조에 대한 보다 정확한 화재성상예측을 위한 실험적 자료로 제시하고자 한다. 건축물의 화재성상 예측은 내화설계 시 반드시 필요하며, 화재성상예측을 위해서는 화재하중, 작용외력, 안전계수 및 설계용 정수의 합리적인 설정이 중요하다. 화재하중 및 작용외력 등은 건축물의 부재가 지니는 하중조건에 대한 화재시의 부재 안정성 예측에 관계되는 부분이며, 설계 시 필요한 데이터 중 내화천장구조 재료의 고온 열특성 값은 화재발생 구획의 화재온도가 주요 구조부재에 전달되는 정도를 예측할 수 있는 인자로 볼 수 있다. 따라서 내화천장구조 재료의 고온 열특성 값 설정은 화재발생 공간의 온도범위($20{\sim}1000^{\circ}C$)에 걸쳐 평가 및 분석되어야만 정확하고 신뢰성 있는 화재발생 예상 공간의 부재 온도 및 안전성 분석이 가능하다. 이에 국내 건축구조물에 사용되고 있는 대표적인 내화피복 재료인 방화석고보드, 텍스, 암면에 대해서 $20^{\circ}C{\sim}900^{\circ}C$까지의 열전도율을 측정하였다. 실험결과 방화석고보드와 텍스의 경우 약 0.15 W/m K까지 일정하게 증가하였다. 암면의 경우 약 $700^{\circ}C$까지는 방화석고보드나 텍스에 비해 열전도율이 낮게 나타났지만, $800^{\circ}C$ 지점부터 용융 및 탄화가 진행되면서 열전도율이 급격히 상승하는 것으로 나타났다.

  • PDF

Effect of Flame Resistant Treatment on The Sound Absorption Capability of Sawdust-mandarin Peel Composite Particleboard (방염처리가 톱밥-귤박 혼합파티클보드의 흡음성능에 미치는 영향)

  • Kang, Chunwon;Jin, Taiquan;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.4
    • /
    • pp.511-517
    • /
    • 2015
  • Sound absorption capability of the flame resistant treated sawdust-mandarin peel composite particleboard was were estimated by two microphone transfer function methods. The weight of flame resistant treated board slightly increased by the treatment. The treatment improved fire retardant performance by decreasing the charred area of flame resistant treated board. Sound absorption capabilities of flame resistant treated sawdust-mandarin peel composite particleboard, in the entire estimated frequency range of 500-6,400 Hz was slightly lower than those of the control specimen. Sound absorption capability of both the control and flame resistant treated sawdust-mandarin peel composite particleboards were higher than that of commercial gypsum boards, being widely used as a sound absorber for ceiling at the estimated frequency.

A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes - (필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 -)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.48-54
    • /
    • 2016
  • Pilotis are support columns that lift a building above the ground. Thus, they can elevate the lowest floor to the secondfloor level and, in Korea, are used to leav a parking area below multifamily housing. However, if there is a fire in the piloti area, the cars and main entrance door are wrapped in flames. Due to the inflammability of the materials, the combustion of the cars and insulation at the ceiling of the pilotis, having a high heat release rate, can quickly destroy the front entrance of the building and spread heat, flames and a poisonous gas to the stairs and elevator pit. Therefore, the fire can quickly spread to the whole building, putting the lives of the residents in danger. This study was an in-depth accidental case study of the "Uijeongbu Fire Accident" that killed 5 residents and injured 139 others. The study identified the relationships between the fire at the piloti structure of multifamily housing and the vulnerability of this structure and its inherent weaknesses.

A Study on the Design of Relocatable Wall System for Office Environment (사무환경을 위한 조립형 벽체 시스템 디자인에 관한 연구)

  • 류호창
    • Archives of design research
    • /
    • v.16 no.1
    • /
    • pp.251-260
    • /
    • 2003
  • The fact that office environment is a principal factor affecting work efficiency is widely accepted. Under such a circumstance, developing relocatable office wall systems is highly required. Psychological, physiological, and economical factors, along with physical factors, should be considered to develope a office wall system. More specifically, competitive price, relocatable efficiency, structural stability, fast installation, health and safety, and aesthetic satisfaction are typical determinants. The evaluation results of newly developed wall system are as below: 1) Panel structural system added with the merits of frame structural system can be studied to accomplish minimal disruption to workplace and better finish details. 2) To cover up the existing interior defects such as uneven floor and ceiling, flexible solutions must be studied especially when panel structural system is accepted. 3) More consideration must be given to finish materials, section details, sound blocking and absorbtion to enhance the satisfaction level.

  • PDF

A Study on the Stability of the Single-Layer Latticed Dome during Erection Using the Step-Up Method (Step-Up 공법에 의한 단층래티스돔의 시공시 안정성 연구)

  • Koo, Choong-Mo;Jung, Hwan-Mok;Kim, Cheol-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.4
    • /
    • pp.109-118
    • /
    • 2012
  • The large-space single-layer lattice dome is relatively simpler in terms of the arrangement of the various framework members and of the design of the junction than the multi-layered lattice dome, can reduce the numbers and quantity of the framework members, and has the merit of exposing the beauty of the framework as it stands. The single-layer lattice dome, however, requires a stability investigation of the whole structure itself, along with an analysis of the stress of the framework members, because an unstable phenomenon called "buckling" occurs when its weight reaches critical levels. Many researchers have systematically conducted researches on the stability evaluation of the single-layer lattice dome. No construction case of a single-layer lattice dome with a 300-m-long span, however, has yet been reported anywhere in the world. The large-space dome structure is difficult to erect due to the gigantic span and higher ceiling compared with other common buildings, and its construction cost is generally huge. The method of erecting a structure causes major differences in the construction cost and period. Therefore, many researchers have been conducting various researches on the method of erecting such structure. The step-up method developed by these authors can reduce the construction cost and period to a great extent compared with the other general methods, but the application of this method inevitably requires the development of system supports in the center section as well as pre-existing supports in the boundary sections. In this research, the safety during the construction of a single-layer lattice dome with 300-m-long span using pre-existing materials was examined in the aspect of structural strength, and the basic data required for manufacturing the supports in the application of the step-up method developed by these authors during the erection of the roof structure were obtained.

Basic Study of Space Design for Healing (힐링 공간디자인의 기초연구)

  • You, Hyun-Bea
    • Journal of Digital Contents Society
    • /
    • v.19 no.1
    • /
    • pp.123-131
    • /
    • 2018
  • The design of the healing space provides people with tranquility and relaxation. It restores the tired body and provides the resilience of life. We have established the importance and value of healing through the meaning of healing and foreign cases. that humans come from nature and return to nature I think it is extremely inevitable, and while living, They set their goal and finish it gradually. Then they reach the goal. You can enjoy the effect of healing by creating an atmosphere of nature that comes from nature and living in it. The use of wood inside the building is the most comfortable healing condition, and as you can see from the case of Japan, The building of Sunny Hills made of wood outside reminds me of a magpies house. Indoor desk or book case made of wood make, warmer at mosphere, and the effect of healing becomes even greater if you take the plants. In the ceiling, if you paint pictures of clouds, trees, sun, etc., and apply blue or pink color that makes you relax, then the effect of healing is doubled. Through this study, I could forming living space being in touch with nature and using natural materials which is basic of healing an bring the effect of healing.

A Study on Application of Distributor for Duct Design at House Ventilation System (주택용 환기시스템의 덕트설계를 위한 분배기 적용성 검토)

  • Yee, Jurng-Jae;Choi, Seok-Yong;Kim, Seok-Keun;Kim, Kwang-Hyun;Lee, Young-Woo;Kim, Hwan-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.770-775
    • /
    • 2007
  • Although these days application of heat recovery ventilation and improved kitchen ventilation system came into wide use in mixed-use residential buildings and exclusive residences, there are not enough ventilation systems except the local ventilation of kitchens and rest rooms. It is very important part to regulate and distribute correct air flow rate for controlling air change rate. The purpose of this study is to investigate the application of distributor at house ventilation system by comparing a duct system with out distributor and with distributor. The results of this study are as follows. (1) When using distributor though the size of duct diameter is reduced rapidly, the pressure loss doesn't rise largely. The pressure loss without distributor is 4.08 mmAq, the pressure loss with distributor 4.10 mmAq. (2) To use distributor can reduce materials of duct and secure enough ceiling space by reducing duct diameter. (3) Diameters and air flow paths of distributor on the design stage are important part for accurate air flow rate.