• Title/Summary/Keyword: ccd

Search Result 2,851, Processing Time 0.029 seconds

Real time MTF Measurement of Copy Lenses by two-dimensional CCDs (2차원 CCD를 이용한 복사기 렌즈의 실시간 MTF 측정)

  • 조현모;이윤우;이인원;김태희;최옥식;이환규
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • Charge-coupled device(CCD) array detectors are widely used in real time modulation transfer function(MTF) measurement systems. This paper presents the characteristics of two-dimensional CCDs used in a real time MTF measurement system for copy lenses. The MTF characteristics of a copy lens measured by this equipment show different results according to the direction of shift register, shutter speed and the amplifier gain of CCDs. An object generator is fabricated to reduce the variation of MTF values for the irradiance nonuniformity in on-axis and off-axis image plane and this MTF equipment is calibrated by using a standard lens.

  • PDF

The design and Manufacture of Laser Induced Fluorescence Spectroscope Using the High Resolution Charge Coupled Device (고정밀 전하결합장치를 이용한 레이저유도 형광분광기의 설계 및 제작)

  • Kim, Ki-Jun;Lee, Hoo-Seol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.129-133
    • /
    • 2005
  • It is very important to use the charge coupled devices (CCDs) in spectrometry because we can study the molecular energy level, molecular structure, absorption or emission, intermolecular reaction, weakly bound molecular energy, photochemistry, fluorescence and photodynamic therapy (PDT). CCD is very essential to study the molecular structure and medical engineering combining laser spectroscopy in the modem physicsal and chemistry. Therefore, this study has designed and manufactured the electromagnetic spectrometry with CCD and then analyzed the printed electronic circuit. In the yesterday, CCD was thought to be used in only broadcasting system. But nowadays, it is used by industrial demand in observations, instrumentations and robotics as the industry develop.

  • PDF

Detection of Address Region of Standard Postal Label Images Acquired from CCD Scanner System (CCD스캐너 시스템에서 획득된 표준 택배 라벨 영상의 주소 영역 검출)

  • 원철호;송병섭;박희준;이수형;임성운;구본후
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.8 no.2
    • /
    • pp.30-37
    • /
    • 2003
  • To effectively control a vast amount of postal packages, we need the automatic system for extracting the address region from CCD scanner images. In this paper, we propose a address region extraction algorithm in the standard postal label. We used geometric characteristics of the underlying address regions and defined several criteria for fast detection of address regions. As a result, we accomplished a successful detection and classification of the postal package labels in real time.

  • PDF

BVR Standardization of the CCD Photometric System of Chungbuk National University Observatory (충북대학교 천문대 CCD 측광계웨 BVR 표준화)

  • Jeong, Jang-Hae;Lee, Yong-Sam;Kim, Chun-Hwey;Yoon, Yo-Na
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.2
    • /
    • pp.157-170
    • /
    • 2009
  • BVR observations for 52 standard stars were performed using the 1-m reflecter with 2K CCD System of Chungbuk National University Observatory (CBNUO) in 2008. We obtained 1,322 CCD images to establish a correlation between our bvr system and the standard Johnson-Cousins BVR system. We derived the tentative equations of transformation between then as follows; V = v-0.0303(B - V) + 0.0466 B - V = 1.3475(b - v) - 0.0251 V - R = 1.0641(v - r) - 0.0125 Using these equations the magnitudes in V, B-V, and V-R for 197 stars were obtained.

Emulsification of O/W Emulsion Using Non-ionic Mixed Surfactant: Optimization Using CCD-RSM (비이온성 혼합계면활성제를 이용한 O/W 유화액의 제조 : CCD-RSM을 이용한 최적화)

  • Lee, Seung Bum;Li, Guangzong;Zuo, Chengliang;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.30 no.5
    • /
    • pp.606-614
    • /
    • 2019
  • A mixing ratio of the oil in water (O/W) emulsion of palm oil and the non-ionic surfactant (Tween-Span type) possessing different hydrophile-lipophilie balance (HLB) values was evaluated in this work. An optimum condition was determined through analysis of main and interaction effects of each quantitative factor using central composite design model-response surface methodology (CCD-RSM). Quantitative factors used by CCD-RSM were an emulsification time, emulsification speed, HLB value and amount of surfactant. On the other hand, the reaction parameters were the viscosity and mean droplet size of O/W emersion. Optimized conditions obtained from CCD-RSM were the emulsification time of 12.7 min, emulsification speed of 5,551 rpm, HLB value of 8.0 and amount of surfactant of 5.7 wt.%. Ideal experimental results under the optimized experimental condition were the viscosity of 1,551 cP and mean droplet size of 432 nm which satisfy the targeted values. The average error value from our actual experiment for verifying the conclusions was below to 2.5%. Therefore, a high favorable level could be obtained when the CCD-RSM was applied to the optimized palm oil to water emulsification.

Optimization for Decolorization and UV-Absorbility of Refined Sea Buckthorn Oil Using CCD-RSM (CCD-RSM을 이용한 시벅턴 오일의 탈색공정 최적화 및 자외선 흡수능력 평가)

  • Hong, Seheum;Zheng, Yunfei;Lee, Seung Bum
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.61-67
    • /
    • 2021
  • In this study, the adsorption decolorization process of sea buckthorn oil was carried out to verify the possibility of the sea buckthorn oil as a natural UV absorber. The optimization was carried out by using the central composite design model-response surface methodology (CCD-RSM). The response values of CCD-RSM were selected as the decolorization effect through the process, acid value after decolorization, and UV absorbance of the decolored oil at 290nm. The amount of adsorbent, temperature and time were selected as the process variables for the experiments. According to the results of CCD-RSM, the results of optimization were all consistent. The optimal conditions, which satisfy CCD-RSM statically and mathematically, were 4.32 wt.%, 134.90 ℃, and 19.8 min for the amount of adsorbent, temperature and time, respectively. The estimated response values expected under these optimal conditions values were 94.78%, 2.08 mg/g KOH, and 2.91 for the decolorization effect, acid value and UV absorbance at 290 nm, respectively. Also the average error from actual experiment for verifying the conclusions was smaller than 2%. Therefore, it was confirmed that the application of CCD-RSM to the adsorption decolorization process of sea buckthorn oil showed a very high level of acceptable results and that the sea buckthorn oil has high possibility to be used as a natural UV absorber.

Tracking of Multi-targets in CCD/IR Multi-sensor system for ITS application (CCD/IR 영상에서의 다중 센서 다중 표적 추적)

  • 이일광;고한석
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.359-362
    • /
    • 2001
  • 본 논문에서는 광학센서와 적외선 센서를 사용하는 Multi-sensor 시스템에서 영상 정보를 통한 물체의 추적 및 인식에 필요한 영상을 분리하는데 필요한 전처리와 object 기반의 추적 방법을 제안하였다. 일반적인 추적 알고리즘의 목표는 consistency를 유지하는데 있다. 그러나 인식에 필요한 영상을 분리하기 위해서는 물체의 범위를 정확히 판단 할 수 있는 능력이 중요하다. 이를 위해 CCD와 IR영상에 동시에 적용 가능한 전처리 기법과 object 기반의 two-step 추적 알고리즘을 통해 consistency외에도, 물체의 범위를 estimation하여 인식에 필요한 범위를 분리해 낸다. 본 논문에서는 ITS 의 ETCS application을 위해 이종 센서인 CCD와 IR의 야간 차량 영상정보를 이용하여 알고리즘을 test 하였다.

  • PDF

PLATE-TO-CCD CONVERTOR. : II. SURFACE PHOTOMETRY OF EARLY TYPET GALAXIES (사진건판-CCD 화상변환장치. : II. 타원은하의 표면측광)

  • Kim, Dong-Woo
    • Publications of The Korean Astronomical Society
    • /
    • v.10 no.1
    • /
    • pp.31-55
    • /
    • 1995
  • We have developed a new device, Plate-to-CCD Convertor (PCC), to conveniently digitize photographic plates in a relatively short time without losing any plate information (Oh et al. 1995). Using this device we have performed surface photometry of 12 early type galaxies. We determined relative orientations and scales to analyze PCC images. We also determined an ellipticity, position angle of the major axis, and $a_4$ of each galaxy to quantify the distribution of surface brightness. We checked the performance and limitation of this device by comparing the PCC images with those digitized by the ST microdensitometer and those obtained with CCD observations.

  • PDF

In-process Measurement of Surface Profile using CCD (CCD를 이용한 인프로세스 표면형상의 계측)

  • 이기용;강명창;김정석;조인순
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.255-258
    • /
    • 1995
  • Surface profile is an important paramerer to evaluate accuracy of machined worpiece. It is necessary to acquire this data by in-process measurement. Recent researchers have introduced Machine Vision technique to achieve it. But it is difficult to apply it to industry field yet. In this study, in-process measuring system of surface profile is developed using CCD camera. The effect of illuminance according to incident angle is investigated and surface profile from surface tester and illuminance graph are compared experimentally.

  • PDF

A Study on the Minimization of Position error Using the DGPS and CCD in the Car Navigation (자동차 항법 시스템에서 DGPS와 CCD를 결합한 위치오차의 최소화에 관한 연구)

  • 권혁대;송석우;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.82-82
    • /
    • 2000
  • The way which estimates a position from Navigation is Dead-reckoning Navigation and Radio Navigation. Generally dead-reckoning navigation uses Gyro and odometer as sensor, but these have problems which are an integrating noise and a noise-sensitivity. Gps which is used by radio-navigation has a Troposthetic error and MultiPath ewer and so on. For minimizing a Troposthetic error and a Multipath error, this paper suggests to an algorithm which use vanishing point on CCD camera.

  • PDF