• Title/Summary/Keyword: cavity volume

Search Result 329, Processing Time 0.027 seconds

Process Planning and Die Design for the Super Hot Forging Product, the Piston Crown Used in Marine Engine (선박엔진용 초대형 열간단조품, 피스톤크라운의 단조공정 및 금형 설계)

  • Hwang, B.C.;Lee, W.H.;Bae, W.B.;Kim, C.
    • Transactions of Materials Processing
    • /
    • v.17 no.8
    • /
    • pp.600-606
    • /
    • 2008
  • In closed-die hot forging, a billet is formed in dies such that the flow of metal from the die cavity is restricted. Some parts can be forged in a single set of dies, whilst others, due to shape complexity and material flow limitations, must be shaped in multi sets of dies. The purpose of a performing operation is to distribute the volume of the parts such that material flow in the finisher dies will be sound. This study focused on the design of preforms, flash thickness and land width by theoretical calculation and finite element analysis, to manufacture the super hot forging product, 70MC type piston crown used in marine engine. The optimal design of preforms by the finite element analysis and the design experiment achieves adequate metal distribution without any defects and guarantees the minimum forming load and fully filling of the cavity of the die for producing the large piston crown. The maximum loads obtained by finite element analysis are compared with the results of experiments. The loads of the analysis have good agreements with those of the experiment. Results obtained using DEFORM-2D enable the designer and manufacturer of super hot forging dies to be more efficient in this field.

A Theoretical Study for the Filling Balance of the Family Mold Using Variable-Runner System (가변 러너 시스템을 이용한 패밀리 금형의 충전밸런스에 관한 이론적 연구)

  • Choi, Kwon-Il;Park, Hyung-Pil;Cha, Baeg-Soon;Rhee, Byung-Ohk;Koo, Bon-Heung
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.275-278
    • /
    • 2007
  • In family mold, defects are frequently occurred by an excessive packing the smaller volume cavity during molding. Although runner size could be optimized by CAE analysis or experimental data, the filling imbalance is hardly avoided in the actual injection molding process by various means. Before this study, we developed a variable-runner system for balancing the cavity-filling for three resins (ABS, LDPE, and PA66) in the family-mold, and examined the effect of cross-sectional area reduction of a runner in the system. In this study, we examined the conditions of the pressure and temperature in the system with a CAE analysis. We also analyzed the influence of the rheological characteristic of resins to the balancing-capability of the system in order to help mold designers easily adopt the variable-runner system to their design.

  • PDF

Theoretical Review and Experiment on Applicability of Double Skin Facade Ventilated by Fans (팬을 부착한 이중외피의 이론적 검토 및 적용성에 대한 실험 연구)

  • Lim, Ji-Hye;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.605-613
    • /
    • 2010
  • Double skin facade(DSF) ventilated by fans consists of a normal external and an internal envelope. In this glass layer, the installed fan replaces an air inlet for the control of air flow through the cavity. The purpose of this paper is to investigate physical theory and to analyze the applicability of fans installed in a DSF. The experiment was conducted in 2 rooms. One room has a DSF with installed fans and the other one has a typical window. The room ventilated through a DSF which fans are installed was always kept warmer than the other room, ventilated directly from the outdoors. The average increase of the supplied air temperature through the DSF ventilated by fans was $6.54^{\circ}C$ at 78CMH, $6.2^{\circ}C$ at 95CMH, and $3.7^{\circ}C$ at 120CMH. As a result, the DSF with installed fans was appropriate for installation in rooms. It supplies outdoor fresh air heated through a cavity and ventilates a constant air volume.

Terahertz Transmission Images For Medical Applications (테라헤르쯔 전자파 의료 영상 기술)

  • Jaeyoung Ryu;Yuchul Jung;Seungyong Baek;Lee, Jongjoo;Kim, Joungho;Soontae Kwon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.118-120
    • /
    • 2000
  • Currently, x-ray is mostly used for the diagnosis of dental cavity and osteoporosis. The osteoporosis is broadly defined as a decrease in the amount of bone mass per unit volume of the bone. Clinically the manifestation of low bone mass presents a clinical problem to the general population as an increase in fracture risk and especially in aging population[1]. Although the amount of the irradiated x-ray to the human body for the clinical diagnosis is relatively small, the exposition of the x-ray to the human body should be minimized as much as possible, since the x-ray is an ionizing radiation. To investigate other possible systems replacing X-ray, ultrasonic imaging and MRI(Magneto-Resonance-Imaging) systems were studied. Unfortunately, an effective and safe diagnosis tool for detecting the dental cavity and the osteoporosis is currently lacking. (omitted)

  • PDF

Numerical Analysis of Non-Axisymmetric Supercavitating Flow Around a Three-Dimensional Cavitator with an Angle of Attack (받음각을 갖는 3차원 캐비테이터에서 발생하는 비축대칭 초공동 유동해석)

  • Dae-Gyu Hwang;Byoung-Kwon Ahn
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.4
    • /
    • pp.240-247
    • /
    • 2023
  • In this study, morphological and hydrodynamic characteristics of the non-axisymmetric supercavity generated behind a disk-shaped cavitator were examined. By extending the previous study on axisymmetric supercavitating flow based on a boundary element method, hydrodynamic forces acting under the angle of attack condition of 0 to 30 ° and shape characteristics of the supercavity were analyzed. The results revealed that increasing the angle of attack by 30 ° reduced the length and width of the cavity by about 15% and the volume by about 40 %. An empirical formula that can quantitatively estimate the geometrical characteristics and change of the cavity was derived. It is expected that this method can be used to evaluate the shape information and force characteristics of the supercavity for the control of the vehicle in a very short time compared to the viscous analysis in the initial design stage of the supercavity underwater vehicle.

Pleuroperitoneal communication-associated pleuritis as an uncommon cause of fever of unknown origin in a child on peritoneal dialysis: a case report

  • Juhee Park;Heeyon Yoon;Jiwon Jung;Jina Lee;Joo Hoon Lee
    • Childhood Kidney Diseases
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2023
  • Pleuroperitoneal communication (PPC) is a rare mechanical complication of peritoneal dialysis (PD), which causes dialysate to move from the peritoneal cavity to the pleural cavity, resulting in pleural effusion. Typically, PPC is discovered through pleural effusion in PD patients who are not in volume overload status. A unique characteristic of the pleural effusion caused by PPC is that it is not resolved by increasing ultrafiltration by dialysis. In this report, we present a 7-year-old girl with PD after birth with the history of various infectious PD-related complications, presenting with fever ongoing for 6 months. PPC-associated pleuritis was suspected as the cause of fever, which eventually developed after long-term PD and induced complicated pleural effusion, lung inflammation, and prolonged fever for 6 months.

The Efficacy of Coblator in Turbinoplasty

  • Lee, Keun-Cheol;Cho, Jeong-Min;Kim, Seok-Kwun;Lim, Kwang-Ryeol;Lee, Sang-Yun;Park, Su-Seong
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.2
    • /
    • pp.82-88
    • /
    • 2017
  • Background: Turbinate hypertrophy is one of the common causes of chronic nasal obstruction. In principle, therapeutic guidelines recommend medical treatment. Failure to treat turbinate thickening despite drug therapy may indicate the need for surgery. The main aim of this study was to determine the effect of radiofrequency surgery, among various other surgical procedures, on people with both nasal septal deviation and turbinate hypertrophy. Methods: Among people with nasal deviation who visited the subject hospital between July 2008 to July 2014, 21 people with nasal septal deviation and severe turbinate hypertrophy before their surgery had undergone septoplasty with turbinoplasty using radiofrequency combined with septoplasty. The degree of the turbinate's hypertrophy was appraised in all the patients before and after the surgery using the rhinoscopy, and acoustic rhinometry was objectively carried out. The subjective effect of the turbinoplasty using radiofrequency was explored through the visual analog scale (VAS) score. Results: The degree of contraction of the nasal mucosa after the rhinoscopy changed from Grades 3 and 4 (100%) to Grades 1 and 2 (95.2%) and Grades 3 (4.8%). The minimal cross-sectional area significantly increased from $0.44{\pm}0.07$ to $0.70{\pm}0.07cm^2$ (p<0.05). The nasal cavity volume increased from $4.79{\pm}0.49$ to $6.76{\pm}0.55cm^2$ (p<0.05). The subjective symptoms evaluated with VAS score a year after the surgery significantly improved (p<0.05). Conclusion: Turbinoplasty using Coblator with septoplasty is an effective treatment method because it expands nasal cavity, has a low incidence of complications, subjectively improves symptoms, and has short treatment duration.

A New Tuning Method of Dual-Mode Waveguide Filters for Satellite Transponder (위성 중계기용 이중모드 도파관 필터의 튜닝에 관한 연구)

  • 이주섭;엄만석;염인복;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.839-844
    • /
    • 2003
  • For mass and volume reduction, input demultiplxer and output multiplexer of satellite transponder widely adopt dual-mode waveguide filters fer channel filters. Generally, channel filters of the input demultiplexer are doubly terminated and channel filters of manifold output multiplexer should be singly terminated fur correct operation. This paper gives a tuning method using short-ended dummy cavity for dual-mode cavity filters. Tuning is based on the match of the computed and measured phase response of reflection coefficient. This proposed method is applied to 4-pole dual-mode doubly terminated elliptic response filter and 6-pole dual-mode singly terminated elliptic response filter for demonstration of this new tuning method. It is shown that this method shows good agreement between the experimental and computed results.

Changes in the Volume and Cortical Thickness of the Specific Regions of Cerebellum of Patients with Major Depressive Disorder (주요우울장애 환자에서 소뇌 국소 부위의 부피와 피질 두께의 차이)

  • Kang, Ji-Won;Han, Kyu-Man;Won, Eunsoo;Tae, Woo-Suk;Ham, Byung-Joo
    • Korean Journal of Biological Psychiatry
    • /
    • v.25 no.3
    • /
    • pp.60-71
    • /
    • 2018
  • Objectives A growing body of evidence has suggested that morphologic changes in cerebellum may be implicated with pathophysiology of major depressive disorder (MDD). The aim of this study is to investigate a difference in the volume and cortical thickness of the specific region of cerebellum between patients with MDD and healthy controls (HC). Methods A total of 127 patients with MDD and 105 HC participated in this study and underwent T1-weighted structural magnetic resonance imaging. We analyzed volume and cortical thickness of each twelve cerebellum regions divided by left and right and the volume and cortical thickness of the whole cerebellum from T1-weigted image of participants. One-way analysis of covariance was used to investigate the volume and cortical thickness difference of total and specific regions between two groups adjusting for age, gender, medication, and total intracranial cavity volume. Results We found that the patients with MDD had significantly greater volume in the left cerebellum lobule III region [false discovery rate (FDR)-corrected p = 0.034] compared to HC. Also, our findings indicate that cortical thickness of left lobule VIIB (FDR-corrected p = 0.032) and lobule VIIIB (FDR-corrected p = 0.032) are significantly thinner in the patients with MDD compared with the HC. No significant volume and cortical thickness differences were observed in other sub-regions of the cerebellum. The volumes and cortical thickness of whole cerebellum between patients with MDD and HC did not differ significantly. Conclusions We observed the region-specific volume and cortical thickness difference in cerebellum between the patients with MDD and HC. The results of our study implicate that the information about structural alterations in cerebellum with further replicative studies might provide a stepping stone toward a specific marker to diagnose MDD.

  • PDF

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.23-26
    • /
    • 2005
  • Introduction: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Methods and Materials: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator , an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was performed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS (192-Ir HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3000cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Result: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1cGy, 57.1cGy, 103.8cGy, 162.7cGy, 165.7cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1cGy, 57.1cGy Conclusion: Patients with locally recurrent tumor in uterine cervix cancer treated with modified MIUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry Provided by the template and cylinders, and improved dose distributions in irregular tumor volume without rectal complication

  • PDF