• Title/Summary/Keyword: cavern

Search Result 229, Processing Time 0.021 seconds

Prediction of Leachate Migration from Waste Disposal Site to Underground LPG Storage Facility and Review of Contamination Control Method by Numerical Simulations (수치모의를 통한 지하 LPG 저장시설에 인접한 폐기물매립지에서의 침출수이동 예측 및 제어공법 검토)

  • 한일영;서일원;오경택
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.2
    • /
    • pp.51-59
    • /
    • 1996
  • In case waste disposal site is to be constructed close to the underground facilities such as LPG storage cavern which is completely maintained by groundwater pressure, it is generally requested that the possibility on leachate contamination of cavern area be reviewed and the countermeasure, if it is estimated cavern area is severely affected by leachate, be taken into consideration. Prediction was performed and leachate control plan was made using by analytical and the numerical analysis on the leachate migration which is likely to happen at the area between the proposed waste disposal site and the underground LPG storage cavern located at the U petrochemical complex. Analytical solutions were obtained by the conservative mass advection-diffusion equation and the effect of advection and dispersion factor on the leachate migration was reviewed through peclet number calculation and the functional relationship between the factors and leachate transport velocity was established, which leads to enable us to predict the leachate transport velocity without difficulties when different parameters (factors) are used for analytical solution. Numerical solutions were obtained by FEM using AQUA2D which is for the simulation of groundwater flow and contaminant transport. 3-D discrete fracture models were simulated and fracture flow analysis was performed and feasibility study on the water-curtain system was conducted through the fracture connectivity analysis in rock mass. As results of those analyses, it was interpreted that the leachate would trespass on the LPG storage cavern area in 30 years from the proposed wate disposal site and the vertical water-curtain system was effective mathod for the prevention of leachate's migration further into the cavern area.

  • PDF

Analysis of Groundwater Flow into Underground Storage Caverns by Using a Boundary Element Model (경계요소모형을 이용한 지하 저장공동의 지하수 유입량 분석)

  • Chung, Il-Moon;Lee, Jeong-Woo;Cho, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.537-544
    • /
    • 2005
  • For the proper management of high pressurized gas storage caverns, analysis of groundwater flow field and inflow quantity according to the groundwater head, gas storage pressure and water curtain head should be performed. The finite element method has been widely used for the groundwater flow analysis surrounding underground storage cavern because it can reflect the exact shape of cavern. But the various simulations according to the change of design factors such as the width of water curtain, shape of cavern etc. are not easy when elements were set up. To overcome these limitations, two dimensional groundwater flow model is established based on the boundary element method which compute the unknown variable by using only the boundary shape and condition. For the exact computation of drainage rate into cavern, the model test is performed by using the exact solution and pre-developed finite element model. The test result shows that the model could be used as an alternative to finite element model when various flow simulations are needed to determine the optimizing cavern shape and arrangement of water curtain holes and so forth.

Case histories on design alternatives during excavation of underground LPG storage cavern and traffic tunnel using TSP survey (TSP 탐사를 이용한 지하유류저장공동 및 도로터널의 시공 중 설계변경 사례 고찰)

  • Cha Sung-Soo;Kim Se-Hoon;Yun Sang-Pil;Bae Jung-Sik;Lee Jin-Moo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.117-136
    • /
    • 1999
  • The geophysical survey at pre-investigation stage can hardly provide the detailed information on geological structure of site which has difficulty in access and thick overburden. The TSP (VSP applied in tunnel) survey at post-investigation stage can show the detailed geology ahead of tunnel and around cavern. The TSP survey was carried out at the Pyongtaek LPG storage cavern site during the cavern excavation and provided the location and orientation of the fault inferred below Namyangho. In order to confirm the result of TSP survey four boreholes were drilled in access tunnel. The fault was also detected by borehole survey and the location was coincided with the result of TSP survey. Depend on the result of TSP survey and core logging, the design such as cavern layout and length could have been changed. As another case history the TSP survey was performed at the Mumeuje road tunnel which has poor geological information due to thick overburden. The support design was also changed on the base of TSP survey.

  • PDF

Characterization of a groundwater system by subsurface hydrogeological investigation data (지하공동굴착 시 수리지질조사 자료를 이용한 저장공동 심도의 지하수체계 특성 연구)

  • 조성일;김천수;김경수;송무영;전한석
    • The Journal of Engineering Geology
    • /
    • v.14 no.1
    • /
    • pp.93-104
    • /
    • 2004
  • This paper intended to assess the hydro-structure characteristics of volcanic rocks based on the hydrogeological data obtained from the underground storage cavern during construction. The variation of groundwater levels was periodically measured from the 28 surface monitoring holes(NX size) and the hydraulic pressures and injection rates were daily monitored from the water curtain holes(95 horizontal holes and 63 vertical holes). The hydraulic interference tests were performed in whole water curtain holes. The distribution patterns of hydraulic pressure are closely related to the dip angles of fracture intersected to the water curtain holes. Three domains can be grouped by the distribution of hydraulic pressures in the horizontal water curtain holes. The initial hydraulic pressures measured immediately after drilling of water crutain holes are high in ascending order of the cavern C-2, C-1, and C-3. The priliminary hydrochemical data also indicate that the portions of the deep groundwater composition is relatively great in the cavern C-3 area. Some of the horizontal water curtain holes in the cavern C-3 show a steady higher groundwater pressure with the composition of shallow groundwater indicating the outer boundary as constant hydraulic boundary. The water curtain holes in the cavern C-2 is characterized as low initial hydraulic pressure and less injection rates, suggesting poor hydraulic connectivity to a shallow groundwater system. The results of the study can help to understand a hydraulic compartment concept in a fracture hydro-geology and be utilized during the surface investigation for a groundwater system.

Thermohydromechanical Behavior Study on the Joints in the Vicinity of an Underground Disposal Cavern (심부 처분공동 주변 절리에서의 열수리역학적 거동변화)

  • Jhin wung Kim;Dae-seok Bae
    • The Journal of Engineering Geology
    • /
    • v.13 no.2
    • /
    • pp.171-191
    • /
    • 2003
  • The objective of this present study is to understand long term(500 years) thermohydromechanical interaction behavior on joints adjacent to a repository cavern, when high level radioactive wastes are disposed of within discontinuous granitic rock masses, and then, to contribute this understanding to the development of a disposal concept. The model includes a saturated discontinuous granitic rock mass, PWR spent nuclear fuels in a disposal canister surrounded with compacted bentonite inside a deposition hole, and mixed bentonite backfilled in the rest of the space within a repository cavern. It is assumed that two joint sets exist within a model. Joint set 1 includes joints of $56^{\circ}$ dip angle, spaced 20m apart, and joint set 2 is in the perpendicular direction to joint set 1 and includes joints of $34^{\circ}$ dip angle, spaced 20m apart. The two dimensional distinct element code, UDEC is used for the analysis. To understand the joint behavior adjacent to the repository cavern, Barton-Bandis joint model is used. Effect of the decay heat from PWR spent fuels on the repository model has been analyzed, and a steady state flow algorithm is used for the hydraulic analysis.

Rock cavern stadium. A research program related to public use of Underground caverns

  • Meland, Oystein
    • Tunnel and Underground Space
    • /
    • v.2 no.1
    • /
    • pp.95-101
    • /
    • 1992
  • Norwegian technology related to preinvestigations, planning, design and construction of large underground caverns is wellknown worldwide. However, so far this technology is only slightly verified through scientiffic reports and documentation. The "Rock cavern stadium" research program is an interdisciplinary program related to the ongoing building and future use of Gjovik Olympic Subsite which is the largest cavern in the world for public purposes with a span of 61 meters and a height of 25 meters. The estimated budget for this program is about USD 4 million which is made possible through grants from The Royal Norwegian Council for Scientific and Industrial Research as well as through contributions from Norwegian and Swedish companies that are participating. The program is carried out in collaboration with The Foundation for Scientific and Industrial Research at the Norwegian Institute of Technology. The Norwegian Geotechnical Institute and The Eastern Norway Research Center. The research program will continue until the end of 1994 to ensure that input comes from a full period of use in this stadium with different activities like exhibitions, conferences, concerts etc being included as verification through full-scale measurements and observations. The research program has five subtasks. Three of these are related to subjects like Energy consumption. HVAC installations. Fire safety design, Engineering geology and Rock mechanics, Environmental aspects. The fourth subtask is concerned with the collection of basic data, results and experience from these three subtasks to provide a basis for national Norwegian guidelines related to this interdisciplinary subject area. The guidelines will first be presented as a manual for planning and engineering purposes. The realization of this research program is a unique opportunity to enhance the expertise that has been acquired from this cavern stadium. By involving research in this extraordinary project from the excavation and building phase to its subsequent use. this will give the participants know-how and expertise which is very much in demand internationally. The coordination of the international activities between the participants as well as preparation of participations and presentations in international conferences and symposium are included in the fifth task of this national research program.

  • PDF

A Study of Numerical Analysis on Hydrogeological Influence by Groundwater Development around Underground Oil Storage Cavern (지하 석유비축기지 주변의 지하수 개발에 의한 수리지질학적 영향의 수치해석 연구)

  • 정현영;송무영;이경주
    • The Journal of Engineering Geology
    • /
    • v.11 no.1
    • /
    • pp.37-50
    • /
    • 2001
  • Through the modeting study on the groundwater now system around the underground stockpile site of crude oil near Seoul, we carried out the research on the influence of the groundwater yield near the site, the effect of the water curtain construction in order to reduce the influence of water yield, and the realized case study by measuring the water level change after the construction of the water curtain. For the simu1ation of the water yield and the water curtain, the nwnerical analysis code, MODFLOW has been utilized. Groundwater levels of the observation wells which were established to observe the hydraulic head around underground oil storage cavern of the study area have been changed in the range of from EL.+30 to +60 meter, while the simulation study revealed that groundwater levels changed in the range of from EL.+20 to +5Om. The hydrogeological condition of the underground oil storage cavern becomes stable by injection water to maintain the groundwater level around the cavern. The result shows the proper input of the hydrogeological factors helps the management to be effective for the oil stockpile site.

  • PDF

Visualization and Optimization of Construction Schedule Considering the Geological Conditions in the Complicated Underground Cavern (지하비축기지 건설시 지질조건을 고려한 건설공정의 가시화와 최적화 사례)

  • Choi, Yong-Kun;Park, Joon-Young;Lee, Sung-Am;Kim, Ho-Yeong;Lee, Hee-Suk;Lee, Seung-Cheol
    • Tunnel and Underground Space
    • /
    • v.19 no.3
    • /
    • pp.167-173
    • /
    • 2009
  • Underground storage cavern is known as the most complicated underground project because of the complexity of construction schedule, tunnel size, and geological problems. In order to optimize the construction schedule of underground storage cavern, two up-to-date technologies were applied. The first technology was 3 dimensional visualization of complicated underground structures, and the second was 4 dimensional simulation considering construction resources, geological conditions and construction schedule. This application case shows that we can achieve optimized construction schedule in the ways to optimize the number of work teams, fleets, the sequence of tunnel excavation, the commencement time of excavation and the hauling route of materials and excavated rocks. 3 dimensional modeling can help designer being able to understand the status of complicated underground structures and to investigate the geological data in the exact 3 dimensional space. Moreover, using 4 dimensional simulation, designer is able to determine the bottle neck point which appear during hauling of excavated rocks and to investigate the daily fluctuation in cost.

Rock bridge fracture model and stability analysis of surrounding rock in underground cavern group

  • Yu, Song;Zhu, Wei-Shen;Yang, Wei-Min;Zhang, Dun-Fu;Ma, Qing-Song
    • Structural Engineering and Mechanics
    • /
    • v.53 no.3
    • /
    • pp.481-495
    • /
    • 2015
  • Many hydropower stations in southwest China are located in regions of brittle rock mass with high geo-stresses. Under these conditions deep fractured zones often occur in the sidewalls of the underground caverns of a power station. The theory and methods of fracture and damage mechanics are therefore adopted to study the phenomena. First a flexibility matrix is developed to describe initial geometric imperfections of a jointed rock mass. This model takes into account the area and orientation of the fractured surfaces of multiple joint sets, as well as spacing and density of joints. Using the assumption of the equivalent strain principle, a damage constitutive model is established based on the brittle fracture criterion. In addition the theory of fracture mechanics is applied to analyze the occurrence of secondary cracks during a cavern excavation. The failure criterion, for rock bridge coalescence and the damage evolution equation, has been derived and a new sub-program integrated into the FLAC-3D software. The model has then been applied to the stability analysis of an underground cavern group of a hydropower station in Sichuan province, China. The results of this method are compared with those obtained by using a conventional elasto-plastic model and splitting depth calculated by the splitting failure criterion proposed in a previous study. The results are also compared with the depth of the relaxation and fracture zone in the surrounding rock measured by field monitoring. The distribution of the splitting zone obtained both by the proposed model and by the field monitoring measurements are consistent to the validity of the theory developed herein.

Numerical Analysis of the Mechanical and Hydraulic behavior of Concrete Plug in Underground Storage Cavern (지하저장공동에서의 콘크리트 플러그의 역학적 및 수리적 거동에 관한 수치해석적 연구)

  • 박병기;이희근;전석원;박의섭
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2000.09a
    • /
    • pp.93-103
    • /
    • 2000
  • The concrete plug in an underground cavern prevents the stored product (oil, gas, etc) from leaking and the excessive show of underground water, so it plays an important role in construction and operation of the storage cavern. Additionally, it should maintain its stability under every possible loading condition. Once the plug is constructed, the cavern is isolated from the external access. Therefore, mechanical and hydraulic consideration should be made in construction to fulfill its function. Therefore, in this study, numerical analyses were conducted to study the optimal shape and thickness of the plug with respect to the various conditions of installation depth, the shape of the plug, in-situ stress ratio (K), the condition of rock-plug interface, and the effect of Excavation Damaged Zone (EDZ). This paper also presents the effect of slot depth on the hydraulic behavior of the plug. These analyses were carried out by using the 2-dimensional finite difference code, rm FLAC, and the 3D code, m FLA $C^{3D}$./.

  • PDF