• 제목/요약/키워드: cationic polymers, optimum dosage

검색결과 6건 처리시간 0.023초

Comparison of Flocculati on-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Sang-Kyu Kam;Lee
    • 한국환경과학회지
    • /
    • 제1권2호
    • /
    • pp.137-144
    • /
    • 1992
  • Flocculation-spectrophotometry and streaming current detector( SCD ) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the formal. and was determined with the dosage required during charge neutralization of humic acid for the latter It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humid acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density, Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF

Comparison of Flocculation-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Kam Sang-Kyu;An Lee-Sun;Lee Min-Gyu
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제1권2호
    • /
    • pp.137-144
    • /
    • 1997
  • Flocculation-spectrophotometry and streaming current detector(SCD) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the former and was determined with the dosage required during charge neutralization of humic acid for the latter. It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humic acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density. Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF

Charge Determination of Humic Acid and Humic Extract by Spectrophotometry

  • Kam Sang Kyu;Cho Eun Il
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제2권2호
    • /
    • pp.139-148
    • /
    • 1998
  • The charge densities of humic acid and humic extract have been determined by back titration using spectrophotometry as the method of end point detection and several cationic polymers of different charge density(copolymers of acylamide and dimethylaminoethylacrylate and polydiallyidimethylammonium chloride, PDDA), and a cationic indicator o-toluidine blue(o-Tb). The charge densities of humic acid and humic extract obtained depend on the charge densities of cationic polymers used. When the polymers of lower charge density are used, lower apparent charge density values are obtained, but for polymers of high charge density(above 2.5 meq/g), the measured values are almost identical, but also are nearly the same as that obtained for PDDA which has a high charge density(about 6 meq/g). For polymers of lower charge density, it is considered that the optimum dosage does not correspond to 1 :1 charge neutralization between anionic and cationic groups. Polymers of high charge density should be used in order to achieve a complete charge neutralization. As humic acid and humic extract are dissociable acids, their ionization is heavily pH dependent and so higher charge density values are obtaines with increasing pH.

  • PDF

정수공정 개선을 위한 유기성 Polymer의 사용 (Utilization of Organic Polymers for Improvement of Drinking Water Treatment Process)

  • 이화자;김정숙;강임석
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.217-222
    • /
    • 1998
  • Organics matters including algae are the major contaminants of Nak-dong river and it's concentration Is more Increasing now. The use of coagulants has been Incresed for the effective treatment of drinking water, and aluminum coagulants have been the most widely used in raw water treatment. However, when inorganic metal coagulant is excessively used for long period, it would result in secondary problems, such as increasing sludge production, enhancing the cost of water treatment process, and increasing concentration of residual metal, especially aluminum. Therefore, recently. in order to reduce the use of metal coagulant and enhance the coagulation effectiveness, several alternative coagulants, such as polymeric Inorganic coagulants and organic polymers, have been used In water treatment plants. The objectives of thins research were (11 to determine optimum dosage concentration and compare the coajuiation efnciency at various pH ranees with alum alone, alum+cationic polymer, and alum+anlonlc polymer, (21 to evaluate the amount of alum reduced by using organic polymer, (31 to maximize removal officiency of organic matter and minimize the concentration of residual aluminum.

  • PDF

DETERMINATION OF THE CATIONIC DEMAND OF PAPERMAKING STOCK USING CHROMOPHORIC LABELED CATIONIC POLYMERS

  • Hiroo Tanaka;Hideaki Ichiura;Takuya Kitaoka
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 1999년도 Proceedings of Pre-symposium of the 10th ISWPC
    • /
    • pp.79-83
    • /
    • 1999
  • A cationic demand(CD) is a very useful indication for determining the optimum dosage rate of retention aids to the papermaking stock at the wet end. Polyelectrolyte titration has been most often used to determine a CD. Highly accurate results can be obtained by this method when the ionic strength of sample is low. But this is accompanied by the serious errors when the ionic strength is higher than that corresponding to 20 milli molar(mM) monovalent, 2 mM divalent or 0.2 mM trivalent ions because of no occurrence of the end point of titration. Therefore, it is very difficult or almost impossible for the conventional method to be applied to the industrial suspensions such as papermaking stock and industrial waste water. Then a novel method using chromophoric labeled cationic polymer which can be applicable to the sample with high ionic strength has been developed.

A SINGLE FLOCCULANT/DUAL FLOCCULATION SYSTEM FOR DEWATERING USING A BRANCHED SELF INVERSING EMULSION FLOCCULANT

  • Bae, Young-Han;Lee, Sung-Sik
    • Environmental Engineering Research
    • /
    • 제11권4호
    • /
    • pp.208-216
    • /
    • 2006
  • In order to create a single flocculant/dual flocculation system, polyacrylamide-co-trimethyl ammonium ethyl acrylate chloride (TAEAC) polymers with varying molecular weights and structures were prepared for use of flocculants. The higher the cationic density of the polymer is higher, the higher was the conversion rate and the ratio of monomer. An acrylamide as nonionic monomer was less reactive than a TAEAC as cationic monomer. The branched polymer which was polymerized with a cross-linking agent, N, N-methylene bis-acrylamide had a higher stability and higher viscosity than a linear polymer but its dewatering efficiency was poor in a single flocculation system. In the case of single flocculant/dual flocculation, the branched polymer has better flocculation efficiency and the water content of the dewatered cakes was lower than the others, as the result of a re-flocculation effect. The optimum conditions for dual flocculation are a sequence in which the $1^{st}$ and $2^{nd}$ dosage are 75% and 25%/total dosage of a single flocculation system. The dewatering efficiency of a dual flocculation system is improved considerably from 10 to 25% under the experimental conditions used herein.