• 제목/요약/키워드: catheter ablation

검색결과 38건 처리시간 0.023초

Use of Cardiac Computed Tomography and Magnetic Resonance Imaging in Case Management of Atrial Fibrillation with Catheter Ablation

  • Hee-Gone Lee;Jaemin Shim;Jong-il Choi;Young-Hoon Kim;Yu-Whan Oh;Sung Ho Hwang
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.695-708
    • /
    • 2019
  • Atrial fibrillation (AF) is the most common arrhythmia associated with the risk of morbidity and mortality in clinical patients. AF is considered as an arrhythmia type that develops and progresses through close connection with cardiac structural arrhythmogenic substrates. Since the introduction of catheter ablation-mediated electrical isolation of arrhythmogenic substrates, cardiac imaging indicates improved treatment outcome and prognosis with appropriate candidate selection, ablation catheter guidance, and post-ablation follow-up. Currently, cardiac computed tomography (CCT) and cardiovascular magnetic resonance (CMR) imaging are essential in the case management of AF at both pre-and post-procedural stages of catheter ablation. In this review, we discuss the roles and technical considerations of CCT and CMR imaging in the management of patients with AF undergoing catheter ablation.

2018 심방세동 카테터 절제술 대한민국 진료지침: PART I

  • 박형섭;정동섭;유희태;박희남;심재민;김주연;김준;이정명;김기훈;노승영;조영진;김영훈;윤남식
    • International Journal of Arrhythmia
    • /
    • 제19권3호
    • /
    • pp.186-234
    • /
    • 2018
  • Catheter and surgical ablation of atrial fibrillation (AF) have evolved from investigational procedures to their current role as effective treatment options for patients with AF. Surgical ablation of AF is available in most major hospitals throughout the world. Catheter ablation of AF is even more widely available, and is now the most commonly performed catheter ablation procedure. Management of patients with AF has traditionally consisted of three main components: (1) anticoagulation for stroke prevention; (2) rate control; and (3) rhythm control. With the emergence of large amounts of data, which have both defined and called attention to the interaction between modifiable risk factors and the development of AF and outcomes of AF management, we believe it is time to include risk factor modification as the fourth pillar of AF management. Catheter and surgical ablation of AF are highly complex procedures, therefore a decision to perform catheter or surgical AF ablation should only be made after a patient carefully considers the risks, benefits, and alternatives to the procedure.

Successful Management of Atrio-Esophageal Fistula after Cardiac Radiofrequency Catheter Ablation

  • Shim, Hun Bo;Kim, Chilsung;Kim, Hong-Kwan;Sung, Kiick
    • Journal of Chest Surgery
    • /
    • 제46권2호
    • /
    • pp.142-145
    • /
    • 2013
  • An increase in cardiac radiofrequency catheter ablation for treating refractory atrial fibrillation has resulted in an increased prevalence of complications. Among numerous complications of radiofrequency catheter ablation, atrio-esophageal fistula, although rare, is known to have fatal results. We report a case of successful management of an atrio-esophageal fistula as a complication of cardiac radiofrequency catheter ablation.

Initial Experience with Total Thoracoscopic Ablation

  • Lee, Hee Moon;Chung, Su Ryeun;Jeong, Dong Seop
    • Journal of Chest Surgery
    • /
    • 제47권1호
    • /
    • pp.1-5
    • /
    • 2014
  • Background: Recently, a hybrid surgical-electrophysiological (EP) approach for confirming ablation lines in patients with atrial fibrillation (AF) was suggested. The aim of this approach was to overcome the limitations of current surgery- and catheter-based techniques to yield better outcomes. Methods: Ten consecutive patients with AF underwent total thoracoscopic ablation (TTA) following transvenous catheter EP ablation (residual gap and cavotricuspid isthmus [CTI] ablation). Holter monitoring was performed 6 months postoperatively. Results: Ten patients (90% with persistent AF) underwent successful hybrid procedures, and there was no in-hospital mortality. An EP study was performed in 8 patients and showed that successful antral ablation in all pulmonary veins was achieved in 7 of them. The median follow-up duration was 7.63 months (range, 6.7 to 11.6 months). Nine patients underwent Holter monitoring 6 months postoperatively, and the results indicated an underlying sinus rhythm without AF, atrial flutter, or atrial tachycardia lasting more than 30 seconds in all of the patients. There was no recurrence of AF during follow-up. Conclusion: A hybrid approach that consists of TTA followed by transvenous catheter EP ablation (residual gap and CTI ablation) yielded excellent outcomes in our patient population. A hybrid approach should be considered in patients with a high risk of AF recurrence.

Evaluation of Left Atrial Appendage Isolation Using Cardiac MRI after Catheter Ablation of Atrial Fibrillation: Paradox of Appendage Reservoir

  • Hyungjoon Cho;Yongwon Cho;Jaemin Shim;Jong-il Choi;Young-Hoon Kim;Yu-Whan Oh;Sung Ho Hwang
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.525-534
    • /
    • 2021
  • Objective: To assess the effect of left atrial appendage (LAA) isolation on LAA emptying and left atrial (LA) function using cardiac MRI in patients who underwent successful catheter ablation of atrial fibrillation (AF). Materials and Methods: This retrospective study included 84 patients (mean age, 59 ± 10 years; 67 males) who underwent cardiac MRI after successful catheter ablation of AF. According to the electrical activity of LAA after catheter ablation, patients showed either LAA isolation or LAA normal activity. The LAA emptying phase (LAA-EP, in the systolic phase [SP] or diastolic phase), LAA emptying flux (LAA-EF, mL/s), and LA ejection fraction (LAEF, %) were evaluated by cardiac MRI. Results: Of the 84 patients, 61 (73%) and 23 (27%) patients showed LAA normal activity and LAA isolation, respectively. Incidence of LAA emptying in SP was significantly higher in LAA isolation (91% vs. 0%, p < 0.001) than in LAA normal activation. LAA-EF was significantly lower in LAA isolation (40.1 ± 16.2 mL/s vs. 80.2 ± 25.1 mL/s, p < 0.001) than in LAA normal activity. Furthermore, LAEF was significantly lower in LAA isolation (23.7% ± 11.2% vs. 31.1% ± 16.6%, p = 0.04) than in LAA normal activity. Multivariate analysis demonstrated that the LAA-EP was independent from LAEF (p = 0.01). Conclusion: LAA emptying in SP may be a critical characteristic of LAA isolation, and it may adversely affect the LAEF after catheter ablation of AF.

온도 조절형 고주파 시스템 및 식염수 분사를 고려한 전극도자절제술용 전극의 수치 모델 개발 (Development of Numerical Model of Electrode for Radiofrequency Catheter Ablation Considering Saline Irrigation and Temperature-controlled Radiofrequency System)

  • 안진우;김영진;이승아;정하철;김경아;차은종;문진희
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권6호
    • /
    • pp.285-290
    • /
    • 2017
  • Radiofrequency catheter ablation is the interventional therapy that be employed to eliminate cardiac tissue caused by arrhythmias. During radiofrequency catheter ablation, The thrombus can occur at electrode tip if the temperature of tissue and electrode is excess $100^{\circ}C$. To prevent this phenomenon, we investigated numerical model of electrode for radiofrequency catheter ablation considering saline irrigation and temperature-controlled radiofrequency system. The numerical model is based on coupled electric-thermal-flow problem and solved by COMSOL Multiphysics software. The results of the models show that the dimensions of the thermal lesion are increased if the flow rate of the saline irrigation and the set temperature are increased. The surface width characterized to determine the thermal lesion isn't need to measure in temperature-controlled radiofrequency system due to convective heat transfer by saline irrigation at tissue-electrode interface.

고주파 절제술을 위한 심장전극도자 원격 제어 로봇 플랫폼의 개발 (Development of a Cardiac Catheter Remote Control Robot Platform for Radiofrequency Ablation Intervention)

  • 박준우;송승준;이정찬;최혁;이정주;최재순
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1417-1426
    • /
    • 2011
  • Radiofrequency ablation through cardiac catheterization is one of minimally invasive intervention procedures used in drug resistant arrhythmia treatment. To facilitate more accurate and precise catheter navigation, systems for robotic cardiac catheter navigation have been developed and commercialized. The authors have been developing a novel robotic catheter navigation system. The system is a network-based master-slave configuration 3-DOF (Degree-Of-Freedom) robotic manipulator for operation with conventional cardiac ablation catheter. The catheter manipulation motion is composed of the translation (forward/backward) and the roll movements of the catheter and knob rotation for the catheter tip articulation. The master manipulator comprises an operator handle compartment for the knob and the roll movement input, and a base platform for the translation movement input. The slave manipulator implements a robotic catheter platform in which conventional cardiac catheter is mounted and the 3-DOF motions of the catheter are controlled. The system software that runs on a realtime OS based PC, implements the master-slave motion synchronization control in the robot system. The master-slave motion synchronization performance tested with step, sinusoidal and arbitrarily varying motion commands showed satisfactory results with acceptable level of steady state error. The developed system will be further improved through evaluation of safety and performance in in vitro and in vivo tests.

2018 심방세동 카테터 절제술 대한민국 진료지침: PART III

  • 이정명;정동섭;유희태;박형섭;심재민;김주연;김준;윤남식;오세일;노승영;조영진;김기훈
    • International Journal of Arrhythmia
    • /
    • 제19권3호
    • /
    • pp.285-339
    • /
    • 2018
  • Catheter ablation of atrial fibrillation (AF) is one of the most complex interventional electrophysiological procedures. The success of AF ablation is based in large part on freedom from AF recurrence based on electrocardiography (ECG) monitoring. Arrhythmia monitoring can be performed with the use of noncontinuous or continuous ECG monitoring tools. AF ablation is an invasive procedure that entails risks, most of which are present during the acute procedural period. However, complications can also occur in the weeks or months following ablation. Recognizing common symptoms after AF ablation and distinguishing those that require urgent evaluation and referral to an electrophysiologist is an important part of follow-up after AF ablation. This section reviews the complications associated with catheter ablation procedures performed to treat AF. The types and incidence of complications are presented, their mechanisms are explored, and the optimal approach to prevention and treatment is discussed. Finally, surgical and hybrid AF ablation technology and the indications for concomitant open or closed surgical ablation of AF, stand-alone and hybrid surgical ablation of AF are covered in this section.

Prognostic Value of Inferior Shift of P wave Axis after Catheter Ablation for Longstanding Persistent Atrial Fibrillation based on Dallas Lesion Set Including Anterior Line

  • Shin, Dong Geum;Kim, Tae-Hoon;Jeong, Hyunmin;Kim, Alexander;Uhm, Jae-Sun;Joung, Boyoung;Lee, Moon-Hyoung;Hwang, Chun;Pak, Hui-Nam
    • International Journal of Arrhythmia
    • /
    • 제18권2호
    • /
    • pp.66-76
    • /
    • 2017
  • Background and Objectives: Although an anterior linear ablation is an effective lesion set in radiofrequency catheter ablation (RFCA) for longstanding persistent atrial fibrillation (L-PeAF), its durability for bidirectional block (BDB) is only about 60% at repeat procedure. We hypothesized that changes in electrocardiogram (ECG) may predict an anterior line block state and the clinical outcome of L-PeAF ablation. Subjects and Methods: We studied 304 L-PeAF patients (77% male, $60{\pm}10yrs$), who consistently underwent RFCA Dallas lesion set (circumferential pulmonary vein isolation, posterior box lesion, and anterior line) protocol with subsequent comparison of pre-procedural and post-procedural P wave axes, and one year follow-up (n=205) sinus rhythm (SR) ECGs. Results: 1. P wave axis shifted inferiorly at immediate post-procedure (p<0.001), and was independently correlated with BDB of anterior line (${\ss}=10.4$, 95% confidence interval [CI] 2.79-17.94, p=0.008). 2. The degree of post-procedural inferior shift of P wave axis did not reflect clinical recurrence within one-year (n=205, p=0.923), potentially due to conduction recovery of an anterior line. However, among 160 patients without clinical recurrence within one-year, P wave axis at one-year ECG was independently associated with very late recurrence of AF after one-year (n=160, hazard ratio [HR] 0.98; 95% CI 0.97-0.99, p=0.001), during $45.6{\pm}16.7$ months of follow-up. 3. Among 22 patients who underwent repeat procedures, P wave axis shift was more significant in patients with maintained BDB of an anterior line than in those without (p=0.015). Conclusion: An inferior shift of P wave axis reflects the achievement and the maintenance of an anterior line BDB, and is associated with better long-term clinical outcome after catheter ablation for L-PeAF based on Dallas lesion set.

Mid-Term Results of Totally Thoracoscopic Ablation in Patients with Recurrent Atrial Fibrillation after Catheter Ablation

  • Lim, Suk Kyung;Kim, Joo Yeon;On, Young Keun;Jeong, Dong Seop
    • Journal of Chest Surgery
    • /
    • 제53권5호
    • /
    • pp.270-276
    • /
    • 2020
  • Background: We investigated the impact of previous catheter ablation (CA) on the midterm outcomes of totally thoracoscopic ablation in patients with lone atrial fibrillation (AF). Methods: Between February 2012 and July 2018, 332 patients underwent totally thoracoscopic ablation for the treatment of AF (persistent AF; n=264, 80%). The patients were stratified into CA (n=47, 14%) and non-CA (nCA; n=285, 86%) groups according to their CA history. Results: All the baseline clinical characteristics and risk factors were similar between the groups except for age, percentage of male patients, prevalence of paroxysmal AF, prior percutaneous coronary intervention, and left atrial volume index (LAVI). No significant intergroup differences were observed in the incidence of early and late complications. At late follow-up, normal sinus rhythm was observed in 92% (43 of 47) of the patients in the CA group and 85% (242 of 285) of the patients in the nCA group (p=0.268). The rate of freedom from AF recurrence at 5 years was 55.3%±11.0% in the CA group, which was similar to that in the nCA group (55.7%±5.1%, p=0.690). In Cox regression analysis, preoperative brain natriuretic peptide levels and LAVI were associated with AF recurrence, but CA history was not significant. Conclusion: Totally thoracoscopic ablation was safe and effective in treating AF irrespective of CA history. A history of CA did not appear to affect the procedural complexity.